1.Effectiveness of combined anteversion angle technique in total hip arthroplasty for treatment of ankylosing spondylitis affecting hip joint.
Yuan WANG ; Fang PEI ; Feng WAN ; Zexuan WANG ; Xiaolei LIU ; Kaijin GUO
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):15-21
OBJECTIVE:
To explore the effectiveness of the combined anteversion angle technique in total hip arthroplasty (THA) for treating ankylosing spondylitis (AS) affecting the hip joint.
METHODS:
A retrospective analysis was conducted on the clinical data of 73 patients with AS affecting the hip joint who underwent THA between August 2018 and August 2021. According to whether the combined anteversion angle technique was used in THA, the patients were divided into study group (37 cases, combined anteversion angle technique was used in THA) and control group (36 cases, traditional THA). There was no significant difference in baseline data such as gender, age, body mass index, disease duration, preoperative Harris score, range of motion (ROM), acetabular anteversion angle, acetabular abduction angle, femoral anteversion angle, and combined anteversion angle between the two groups ( P>0.05). The operation time, hospital stay, and complications of the two groups were recorded and compared. The Harris score and hip ROM were compared between the two groups before operation, at 1, 3, 6, 12 months after operation, and at last follow-up. The acetabular component anteversion angle, femoral component anteversion angle, acetabular component abduction angle, and component combined anteversion angle were measured postoperatively.
RESULTS:
The operation time in the study group was significantly shorter than that in the control group ( P<0.05), and there was no significant difference in hospital stay between the two groups ( P>0.05). There was no intraoperative complication such as acetabular and proximal femoral fractures, neurovascular injuries in both groups, and the incisions healed by first intention. All patients were followed up 2-3 years, with an average of 2.4 years; there was no significant difference in the follow-up time between the two groups ( P>0.05). During the follow-up period, there was no complication such as hip dislocation, wound infection, delayed wound healing, deep venous thrombosis, and hip dislocation in both groups. The hip Harris score and ROM of the two groups gradually increased with time after operation, and the differences were significant when compared with those before operation ( P<0.05); the above two indicators of the study group were significantly better than those of the control group at each time point after operation ( P<0.05). Extensive bone ingrowth on the surface of the components could be observed in the anteroposterior X-ray films of the hip joint of the two groups at 12 months after operation, and the acetabular components was stable without femoral stem subsidence, osteolysis around the components, and heterotopic ossification. At last follow-up, the acetabular component anteversion angle, femoral component anteversion angle, and component combined anteversion angle in the study group were significantly superior to those in the control group ( P<0.05), except that there was no significant difference in the acetabular component abduction angle between the two groups ( P>0.05).
CONCLUSION
For patients with AS affecting the hip joint, the use of the combined anteversion angle technique during THA effectively promotes the recovery of hip joint function and enhances the postoperative quality of life of patients when compared to traditional THA.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Hip Dislocation/surgery*
;
Spondylitis, Ankylosing/surgery*
;
Retrospective Studies
;
Quality of Life
;
Treatment Outcome
;
Hip Joint/surgery*
;
Hip Prosthesis
3.Three-dimensional-printed hemi-pelvic prosthesis for revision of aseptic loosening or screw fracture of modular hemi-pelvic prosthesis.
Xin LIU ; Yi LUO ; Xuanhong HE ; Jie WANG ; Zhuangzhuang LI ; Yuqi ZHANG ; Xin HU ; Minxun LU ; Fan TANG ; Yong ZHOU ; Li MIN ; Chongqi TU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1183-1189
OBJECTIVE:
To investigate the effectiveness of three-dimensional (3D)-printed hemi-pelvic prosthesis for revision of aseptic loosening or screw fracture of modular hemi-pelvic prosthesis.
METHODS:
Between February 2017 and January 2020, 11 patients with aseptic loosening or screw fracture of modular hemi-pelvic prosthesis were revised using 3D-printed hemi-pelvic prostheses. There were 7 males and 4 females with an average age of 44 years (range, 25-60 years). In the first operation, all patients underwent total tumor resection, modular hemi-pelvic prosthesis reconstruction, and autologous femoral head transplantation. According to the Enneking pelvic partition system, 8 cases were resected in zones Ⅰ+Ⅱ and 3 cases in zones Ⅰ+Ⅱ+Ⅲ. The interval from the initial operation to this revision ranged from 14.3-66.2 months, with an average of 35.8 months. The operation time, the amount of intraoperative bleeding, and the occurrence of complications were recorded. At 6 months after the first operation, before revision, and at last follow-up, the American Musculoskeletal Tumor Society (MSTS) score and Harris score were used to evaluate the recovery of lower limb function. The pain-free walking distance of patients without brace assistance was recorded at last follow-up. X-ray films were taken at 1 month after the first operation, before revision, and at 1 month after revision, the acetabulum position was assessed by the differences in weight arm and cup height between bilateral hip joints. At last follow-up, the digital X-ray tomography was taken to evaluate the prosthesis-bone integration and the occurrence of aseptic loosening.
RESULTS:
The operation time was 182.6-238.0 minutes (mean, 197.4 minutes). The amount of intraoperative bleeding was 400-860 mL (mean, 550.0 mL). All incisions healed by first intention with no infection, hip dislocation, nerve damage, or vascular-related adverse events. The MSTS score and Harris score at last follow-up were significantly higher than those at 6 months after the first operation and before revision ( P<0.05), while the score before revision was significantly lower than that at 6 months after the first operation ( P<0.05). At last follow-up, the patients were able to walk more than 1 000 meters painlessly without brace assistance. Imaging review showed that the difference of cup height at 1 month after revision was significantly lower than that at 1 month after the first operation and before revision, and at 1 month after the first operation than before revision operation, and the differences were significant ( P<0.05). There was no significant difference in the difference of weight arm among three time points ( P>0.05). All prostheses were well integrated, and no aseptic loosening of the prosthesis or screw fracture occurred.
CONCLUSION
Revision with 3D-printed hemi-pelvic prostheses benefited in reconstructing stable pelvic ring and natural bodyweight transmission for patients encountering the aseptic loosening or screw fracture of modular hemi-pelvic prosthesis. Early postoperative rehabilitation training can maximize the recovery of patient limb function, reduce pain during walking, and reduce the incidence of complications.
Male
;
Female
;
Humans
;
Adult
;
Arthroplasty, Replacement, Hip/methods*
;
Hip Prosthesis
;
Treatment Outcome
;
Prosthesis Failure
;
Fractures, Bone/surgery*
;
Retrospective Studies
;
Neoplasms
4.Advances in revision surgery after primary total hip arthroplasty for Crowe type Ⅳ developmental dysplasia of the hip.
Yi LIU ; Shuqiang LI ; Qisheng CHENG ; Jie MU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(12):1548-1555
OBJECTIVE:
To review research advances of revision surgery after primary total hip arthroplasty (THA) for patients with Crowe type Ⅳ developmental dysplasia of the hip (DDH).
METHODS:
The recent literature on revision surgery after primary THA in patients with Crowe type Ⅳ DDH was reviewed. The reasons for revision surgery were analyzed and the difficulties of revision surgery, the management methods, and the related prosthesis choices were summarized.
RESULTS:
Patients with Crowe type Ⅳ DDH have small anteroposterior diameter of the acetabulum, large variation in acetabular and femoral anteversion angles, severe soft tissue contractures, which make both THA and revision surgery more difficult. There are many reasons for patients undergoing revision surgery after primary THA, mainly due to aseptic loosening of the prosthesis. Therefore, it is necessary to restore anatomical structures in primary THA, as much as possible and reduce the generation of wear particles to avoid postoperative loosening of the prosthesis. Due to the anatomical characteristics of Crowe type Ⅳ DDH, the patients have acetabular and femoral bone defects, and the repair and reconstruction of bone defects become the key to revision surgery. The acetabular side is usually reconstructed with the appropriate acetabular cup or combined metal block, Cage, or custom component depending on the extent of the bone defect, while the femoral side is preferred to the S-ROM prosthesis. In addition, the prosthetic interface should be ceramic-ceramic or ceramic-highly cross-linked polyethylene wherever possible.
CONCLUSION
The reasons leading to revision surgery after primary THA in patients with Crowe type Ⅳ DDH and the surgical difficulties have been clarified, and a large number of clinical studies have proposed corresponding revision modalities based on which good early- and mid-term outcomes have been obtained, but further follow-up is needed to clarify the long-term outcomes. With technological advances and the development of new materials, personalized prostheses for these patients are expected to become a reality.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Hip Prosthesis
;
Hip Dislocation, Congenital/surgery*
;
Reoperation
;
Developmental Dysplasia of the Hip/surgery*
;
Acetabulum/surgery*
;
Retrospective Studies
;
Treatment Outcome
5.Construction and evaluation of a nomogram prediction model for periprosthetic fractures after total hip arthroplasty.
Xin LI ; Xiao-Yong LEI ; Da-Wei KANG
China Journal of Orthopaedics and Traumatology 2023;36(11):1036-1040
OBJECTIVE:
To construct and evaluate nomogram prediction model for periprosthetic fractures in patients undergoing total hip arthroplasty (THA).
METHODS:
A total of 538 patients who underwent THA from April 2013 to February 2019 were selected as the research subjects, including 318 males and 220 females, aged 40 to 60 years old with an average age of (50.79±6.37) years old. All patients with THA were divided into non-fracture group (506 patients) and fracture group (32 pathents) according to the 3-year follow-up results. Univariate and multivariate Logistic regression analyses were performed to analyze the influencing factors of postoperative periprosthetic fractures in patients with THA. A nomogram prediction model for periprosthetic fractures in patients undergoing THA was constructed, and the validity and discrimination of the prediction model were evaluated.
RESULTS:
The proportion of patients with osteoporosis, trauma history, and hip revision in the fracture group were higher than those in the non-fracture group(P<0.05), and the proportion of bone cement prosthesis was lower than that in the non-fracture group(P<0.05). The osteoporosis status[OR=4.177, 95%CI(1.815, 9.617), P<0.05], trauma history[OR=7.481, 95%CI(3.104, 18.031), P<0.05], and hip revision[OR=11.371, 95%CI(3.220, 40.153, P<0.05] were independent risk factors for postoperative periprosthetic fractures in patients undergoing THA, cemented prosthesis [OR=0.067, 95%CI(0.019, 0.236), P<0.05] was an independent protective factor for postoperative periprosthetic fractures in patients undergoing THA(P<0.05). Hosmer-Lemeshow goodness of fit test showed that χ2=7.864, P=0.325;the area under the curve (AUC) for periprosthetic fractures in patients undergoing THA was 0.892 with a sensitivity of 87.5% and a specificity of 77.7% by receiver operating characteristic(ROC) curve.
CONCLUSION
The nomogram prediction model for periprosthetic fractures after THA constructed in this study has good discrimination, which is beneficial to clinical prediction of periprosthetic fractures in patients undergoing THA, and facilitates individualized fracture prevention.
Male
;
Female
;
Humans
;
Adult
;
Middle Aged
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Periprosthetic Fractures/surgery*
;
Nomograms
;
Reoperation/adverse effects*
;
Risk Factors
;
Osteoporosis/surgery*
;
Retrospective Studies
;
Hip Prosthesis
6.Effects of denosumab on bone mineral density around proximal femoral prosthesis after total hip replacement in postmenopausal osteoporotic patients.
Wei-Hong NING ; Guo-Zhu XU ; Jian-Wei WANG
China Journal of Orthopaedics and Traumatology 2023;36(11):1041-1045
OBJECTIVE:
To evaluate the effect of denosumab on bone mineral density around proximal femoral prosthesis after total hip arthroplasty(THA) in the postmenopausal osteoporotic patients.
METHODS:
Fifty-four consecutive patients underwent unilateral primary THA were included in this retrospective study. Twenty-five patients received denosumab for osteoporosis as the treatment group, and the twenty-nine without denosumab were the control group. At 1 week, 3month, 6 months, and 12 months after THA, bone turnover markers and proximal femoral periprosthetic bone mineral density (BMD) were measured.
RESULTS:
At 3, 6 and 12 months after operation, the level of TRACP-5b in the control group was significantly higher than that in the treatment group (P<0.05);the level of bone-specific alkaline phosphatase (BALP) between two groups showed significant difference in 12 months after operation (control group was higher than treatment group, P<0.05). The BMD of Gruen 1 and Gruen 7 decreased at 3, 6 and 12 months after operation compared with 1 week after operation. Comparing the treatment group and the control group, the differences of the the decrease of BMD in Gruen 1 and Gruen 7 were no significant at 3 months after surgery. In Gruen 1, Gruen 7 at 6 months after operation and Gruen 1, Gruen 7 at 12 months after operation, the decrease of BMD in the control group was significantly higher than that in the treatment group(P<0.05). It is suggested that desudumab could inhibit the loss of BMD after 6 months, and continuously show a protective effect on bone mass at 12 months after operation.
CONCLUSION
After THA in postmenopausal patients with osteoporotic femoral neck fracture, Desuzumab can reduce the loss of BMD around the proximal femoral prosthesis and effectively inhibit bone resorption.
Humans
;
Arthroplasty, Replacement, Hip
;
Bone Density
;
Denosumab/therapeutic use*
;
Retrospective Studies
;
Postmenopause
;
Absorptiometry, Photon
;
Bone Remodeling
;
Follow-Up Studies
;
Hip Prosthesis
7.Total hip arthroplasty for post-firearm hip arthritis complicated by coloarticular fistula: A case report.
Ahmed M ABDELAAL ; Mohammad Kamal ABDELNASSER ; Mohamed Ma MOUSTAFA ; Ahmed Mohamed ALI ; Haisam ATTA ; Ahmed A KHALIFA
Chinese Journal of Traumatology 2023;26(6):369-374
Hip firearm injuries are rare injuries that could lead to serious complications, such as posttraumatic hip arthritis and coloarticular fistula. We report a case of a 25-year-old male who sustained a pelvic injury caused by a single bullet which led to a bilateral acetabular fracture, concomitant with a colon injury treated on an emergency basis by a diverting colostomy; acetabular fractures were treated conservatively by traction. After the patient recovered from the abdominal injury, he was presented with bilateral hip pain and limited motion; plain radiographs showed bilateral hip arthritis with proximal migration of the femoral head and bilateral acetabular defect classified as Paprosky type ⅢA. Reconstruction of the hips was performed using the same technique: impaction bone grafting for acetabular defect reconstruction and a reversed hybrid total hip arthroplasty (THA) 6 months apart. The patient presented with loosening of the left THA acetabular cup 3 years later, which was revised; then he presented with a discharging sinus from the left THA with suspicion of coloarticular fistula, which was confirmed using CT with contrast material. A temporary colostomy and fistula excision were performed, and a cement spacer was applied to the hip. After clearing the infection, a final revision THA for the left hip was performed. Treating post-firearm hip arthritis by THA is challenging, especially in the situation of neglected cases with the presence of an acetabular defect. Concomitant intestinal injury increases the risk of infection with the possibility of coloarticular fistula formation, which could present later. Working with a multidisciplinary team is paramount.
Male
;
Humans
;
Adult
;
Arthroplasty, Replacement, Hip
;
Firearms
;
Wounds, Gunshot/surgery*
;
Acetabulum/injuries*
;
Hip Fractures/surgery*
;
Arthritis/surgery*
;
Spinal Fractures/surgery*
;
Reoperation
;
Fistula/surgery*
;
Treatment Outcome
;
Follow-Up Studies
;
Prosthesis Failure
;
Retrospective Studies
8.Meta-analysis of different joint interfaces in total hip arthroplasty under long-term follow-up.
Gai-Ge WU ; Ling-An HUANG ; Li GUO ; Peng-Cui LI ; Xiao-Chun WEI
China Journal of Orthopaedics and Traumatology 2023;36(2):165-171
OBJECTIVE:
To compare the long-term follow-up effect and complications of ceramic on ceramic (CoC) interface and ceramic on polyethyleneon ceramic (CoP) interface in primary total hip arthroplasty, and provide clinical evidence.
METHODS:
Search PubMed, EMBase, the CoChrane Library databases, Web of science, Wanfang database, and CNKI from January 2000 to September 2021, screening and inclusion of randomized controlled trials (RCTs) comparing the long-term efficacy and complications of CoC interface and CoP interface in total hip arthroplasty. Literature screening, quality evaluation and data extraction were carried out according to the inclusion and exclusion criteria, using Review Manager 5.3 statistical software. The software was used to perform statistical analysis on joint function, revision, prosthesis fracture, abnormal joint noise, and prosthesis wear rate after CoC or CoP.
RESULTS:
Seven RCTs studies were included, including 390 cases of hips with CoC artificial joints and 384 cases of hips with CoP artificial joints. The long-term joint function improvement of CoC and CoP artificial joints was similar and there was no significant differences, with an average difference was MD=0.63, 95%CI=(-1.81, 3.07), P=0.61. About the postoperative complications, CoC artificial joints have higher incidence rate of abnormal joint noise, with odds ratio (OR)=11.05, 95%CI=(2.04, 59.84), P=0.005. CoP artificial joints wear faster, with an average MD=-87.11, 95%CI=(-114.40, -59.82), P<0.000 1. There was no significant difference between the two groups in the replacement-related complications such as joint dislocation, prosthesis loosening, osteolysis, and the rate of prosthesis revision caused by various reasons.
CONCLUSION
The clinical function results and complications of CoC artificial joints are comparable to those of CoP artificial joints. Although CoP artificial joint prosthesis has a faster wear rate, it does not affect joint function and increase complications, and there is no abnormal joint noise. CoC is expensive and the long-term efficacy is equivalent to CoP. Clinicians should consider cost performance when choosing CoC.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Hip Prosthesis
;
Follow-Up Studies
;
Prosthesis Design
;
Polyethylene
;
Prosthesis Failure
;
Reoperation
;
Ceramics
;
Treatment Outcome
9.Imaging measurement and analysis of related indexes of variation of femoral head rotation center.
Yan-Shan SUN ; Ji-Cheng WANG ; Chang-Kun WU ; Yong-Zhi GAO ; Jiang XIN ; Yang-Yang ZHANG
China Journal of Orthopaedics and Traumatology 2023;36(3):284-288
OBJECTIVE:
To provide guidance for hip replacement by analyzing the variation of femoral head rotation center in different hip diseases.
METHODS:
A total of 5 459 patients were collected from March 2016 to June 2021, who took positive and proportional plain films of both hips for various reasons. The relative position between the rotation center of the femoral head and the apex of the greater trochanter was measured. The positive variation is more than 2 mm above the top of the great trochanter, and the negative variation is more than 2 mm below the top of the great trochanter. A total of 831 patients with variation of femoral head rotation center were collected and were divided into 4 groups according to different diseases, and the variation was counted respectively. There were 15 cases in the normal group involving 10 cases of positive variation and 5 cases of negative variation. There were 145 cases of avascular necrosis of femoral head involving 25 cases of positive variation and 120 cases of negative variation. There were 346 cases of congenital hip dysplasia involving 225 cases of positive variation(including 25 cases of typeⅠ, 70 cases of type Ⅱ, 115 cases of type Ⅲ and 15 cases of type Ⅳ), and 121 cases of negative variation(including 50 cases of crowe typeⅠ, 60 cases of typeⅡ, 10 cases of type Ⅲ and 1 case of type Ⅳ). There were 325 cases of hip osteoarthritis group involving 45 cases of positive variation and 280 cases of negative variation.
RESULTS:
There was significant difference in variation of femoral head rotation center among the four groups(P<0.05). There was significant difference in variation of femoral head rotation center among different types of congenital hip dysplasia(P<0.05). There were significant differences in cervical trunk angle and eccentricity among different variations of femoral head rotation center(P<0.05).
CONCLUSION
The variation of femoral head rotation center is related to cervical trunk angle and eccentricity. The variation of femoral head rotation center is an important factor in hip diseases. The variation of femoral head rotation center is different in different hip diseases. Avascular necrosis of the femoral head and osteoarthritis of the hip were mostly negative variations. With the aggravation of congenital hip dysplasia, the variation of femoral head rotation center gradually changed from negative variation to positive variation.The variation of femoral head rotation center should be paid attention to in the preoperative planning of hip arthroplasty. It is of great significance to select the appropriate prosthesis and place the prosthesis accurately.
Humans
;
Femur Head/surgery*
;
Hip Dislocation, Congenital/surgery*
;
Hip Prosthesis
;
Arthroplasty, Replacement, Hip/methods*
;
Femur/surgery*
;
Retrospective Studies
;
Treatment Outcome
10.Comparison of filling ratio, alignment, and stability between ABG Ⅱ short-stem and Corail long-stem in total hip arthroplasty for Dorr type C femur.
Xianchao BAO ; Mingyang LI ; Limin WU ; Shenghu JIANG ; Bin SHEN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(6):641-646
OBJECTIVE:
Using the mono-energy reconstruction images and X-ray films to investigate whether the ABG Ⅱ short-stem could improve the filling ratio, stability, and alignment in the Dorr type C femur, compared with the Corail long-stem.
METHODS:
Among patients who were with Dorr type C femurs and treated with total hip arthroplasty between January 2006 and March 2012, 20 patients with a Corail long-stem (Corail group) and 20 patients with an ABG Ⅱ short-stem (ABG Ⅱ group) were randomly selected. The differences in gender, age, body mass index, and preoperative diagnoses between the two groups were not significant ( P>0.05). The ABG Ⅱ group was with a mean follow-up of 142 months (range, 102-156 months), and the Corail group was with a mean follow-up of 107 months (range, 91-127 months). There was no significant difference in the Harris score and subjective satisfaction score between the two groups at last follow-up ( P>0.05). At last follow-up, dual-energy CT scans with mono-energy image reconstruction were used to calculate the prosthetic filling ratio and to measure the alignment of the prosthesis in the coronal and sagittal positions. Stability assessment was performed based on X-ray films, and the subsidence distance was measured using EBRA-FCA software.
RESULTS:
X-ray film observation showed that the prostheses in the two groups were stable and no signs of loosening was found. The incidence of pedestal sign was significantly lower in the ABGⅡ group than in the Corail group ( P<0.05), and the incidence of heterotopic ossification was significantly higher in the ABGⅡ group than in the Corail group ( P<0.05). The subsidence distance of femoral stem in ABG Ⅱ group was significantly greater than that in Corail group ( P<0.05), and the subsidence speed of femoral stem in ABG Ⅱ group was also greater than that in Corail group, but the difference was not significant ( P>0.05). The overall prosthesis filling ratio was significantly higher in the ABG Ⅱ group than in the Corail group ( P<0.05), while the coronal filling ratio at the lesser trochanter, 2 cm below the lesser trochanter, and 7 cm below the lesser trochanter were not significant ( P>0.05). The results of prosthesis alignment showed that there was no significant difference in the sagittal alignment error value and the incidence of coronal and sagittal alignment error >3° between the two groups ( P>0.05), while the coronal alignment error value in the ABG Ⅱ group was significantly greater than that in the Corail group ( P<0.05).
CONCLUSION
Although the ABG Ⅱ short-stem avoids the distal-proximal mismatch of the Corail long-stem in the Dorr type C femur and thus achieves a higher filling ratio, it does not appear to achieve better alignment or stability.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Femur/surgery*
;
Hip Prosthesis
;
Lower Extremity/surgery*
;
Prosthesis Design
;
Retrospective Studies

Result Analysis
Print
Save
E-mail