1.Preoperative MR T2WI signal characteristics of adenomyosis are closely related with the outcome of high-intensity focused ultrasound ablation: a propensity score-matched cohort study.
Jingwen YU ; Meijie YANG ; Li JIANG ; Zhibo XIAO ; Shuang LI ; Jinyun CHEN
Journal of Southern Medical University 2023;43(4):597-603
OBJECTIVE:
To evaluate the correlation of magnetic resonance (MR) T2-weighted image (T2WI) signal characteristics of adenomyosis and the efficacy of high-intensity focused ultrasound (HIFU) ablation.
METHODS:
Based on the presence or absence of patchy hyperintense foci on preoperative MR T2WI, the patients with adenomyosis undergoing HIFU treatment were divided into homogeneous signal group and heterogeneous signal group, and the heterogeneous group was further divided into heterogeneous hypointense group and heterogeneous isointense group according to signal intensity of the lesions. The patients in heterogeneous signal group were matched with the patients in the homogeneous group at a 1:1 ratio using the propensity score matching, and similarly, the patients in the heterogeneous hypointense group were matched with those in the heterogeneous isointense group at a 1:1 ratio. The non-perfused volume ratio (NPVR) and relief of dysmenorrhea were used to assess the therapeutic efficacy in the 4 groups.
RESULTS:
A total of 299 patients were enrolled, who had a median preoperative dysmenorrhea score of 7.0 (6.0, 8.0) and a median NPVR of 53.5% (35.4, 70.1)%. After propensity score matching, the NPVR in homogeneous signal group was significantly higher than that in heterogeneous signal group [(60.3 ± 21.8)% vs (44.6±21.6)%, P < 0.05]. At 3, 6 and 12 months after HIFU, dysmenorrhea relief rates were higher in homogeneous signal group than in heterogeneous signal group, and the difference was statistically significant at 12 months (91.1% vs 76.8%, P < 0.05). The NPVR of heterogeneous hypointense group was higher than that of heterogeneous isointense group [(54.0±22.0) % vs (47.3± 22.9) %, P < 0.05]. At 6 months after HIFU, dysmenorrhea relief rate was significantly higher in heterogeneous hypointense group than in heterogeneous isointense group (91.5% vs 80.9%, P < 0.05).
CONCLUSION
The signal characteristics of adenomyosis on T2WI are closely related with the outcome of HIFU ablation, and its efficacy is better for homogeneous than for heterogeneous adenomyosis, and better for heterogeneous hypointense adenomyosis than for heterogeneous isointense adenomyosis.
Female
;
Humans
;
Adenomyosis/pathology*
;
Dysmenorrhea
;
Cohort Studies
;
Propensity Score
;
High-Intensity Focused Ultrasound Ablation/methods*
;
Treatment Outcome
2.Efficacy, Efficiency, and Safety of Magnetic Resonance-Guided High-Intensity Focused Ultrasound for Ablation of Uterine Fibroids: Comparison with Ultrasound-Guided Method.
Yi WANG ; Zhi Biao WANG ; Yong Hua XU
Korean Journal of Radiology 2018;19(4):724-732
OBJECTIVE: The purpose of this study was to compare efficacy, sonication energy efficiency, treatment time and safety of magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU) and those of ultrasound-guided high-intensity focused ultrasound (USgHIFU) for ablation of uterine fibroids. MATERIALS AND METHODS: This study included 43 patients with 44 symptomatic uterine fibroids treated with MRgHIFU and 51 patients with 68 symptomatic uterine fibroids treated with USgHIFU. After therapy, contrast-enhanced MRI was conducted and complete ablation was defined as 100% non-perfused volume (NPV) of fibroids. Patients with completely ablated fibroids were selected for the comparison of the treatment data and sonication parameters between MRgHIFU and USgHIFU treated groups. RESULTS: Thirteen completely ablated fibroids in 10 patients (23.3%, 10/43) were achieved with MRgHIFU and 28 completely ablated fibroids in 22 patients (43.1%, 22/51) were achieved with USgHIFU. In completely ablated fibroids, the energy-efficiency factor (EEF) was 5.1 ± 3.0 J/mm3 and 4.7 ± 2.5 J/mm3 in the MRgHIFU and USgHIFU, respectively (p = 0.165). There was a negative linear correlation between EEF and the NPV of fibroids for MRgHIFU (p = 0.016) and USgHIFU (p = 0.001). The mean treatment time was 174.5 ± 42.2 minutes and 114.4 ± 39.2 minutes in the MRgHIFU and USgHIFU procedures, respectively (p = 0.021). There were no severe adverse events and major complications after treatment. CONCLUSION: MRgHIFU and USgHIFU are safe and effective with the equivalent energy efficiency for complete ablation of fibroids. USgHIFU has shorter treatment time than MRgHIFU.
High-Intensity Focused Ultrasound Ablation
;
Humans
;
Leiomyoma*
;
Magnetic Resonance Imaging
;
Methods*
;
Sonication
;
Ultrasonography*
3.The key points of prevention for special surgical complications after radical operation of gastric cancer.
Hao XU ; Weizhi WANG ; Panyuan LI ; Diancai ZHANG ; Li YANG ; Zekuan XU
Chinese Journal of Gastrointestinal Surgery 2017;20(2):152-155
Incidence of gastric cancer is high in China and standard radical operation is currently the main treatment for gastric cancer. Postoperative complications, especially some special complications, can directly affect the prognosis of patients, even result in the increase of mortality. But the incidences of these special complications are low, so these complications are often misdiagnosed and delayed in treatment owing to insufficient recognition of medical staff. These special complications include (1) Peterson hernia: It is an abdominal hernia developed in the space between Roux loop and transverse colon mesentery after Roux-Y reconstruction of digestive tract. Peterson hernia is rare and can quickly result in gangrenous ileus. Because of low incidence and without specific clinical symptoms, this hernia does not attract enough attention in clinical practice, so the outcome will be very serious. Once the diagnosis is made, an emergent operation must be performed immediately. Peterson space should be closed routinely in order to avoid the development of hernia. (2) Lymphatic leakage: It is also called chyle leakage. Cisterna chylus is formed by gradual concentration of extensive lymphatic net to diaphragm angle within abdominal cavity. Lymphadenectomy during operation may easily damage lymphatic net and result in leakage. The use of ultrasonic scalpel can decrease the risk of lymphatic leakage in certain degree. If lymphatic leakage is found during operation, transfixion should be performed in time. Treatment includes total parenteral nutrition, maintenance of internal environment, supplement of protein, and observation by clamp as an attempt. (3)Duodenal stump leakage: It is one of serious complications affecting the recovery and leading to death after subtotal gastrectomy. Correct management of duodenal stump during operation is one of key points of the prevention of duodenal stump leakage. Routine purse embedding of duodenal stump is recommend during operation. The key treatment of this complication is to promt diagnosis and effective hemostasis.(4) Blood supply disorder of Roux-Y intestinal loop: Main preventive principle of this complication is to pay attention to the blood supply of vascular arch in intestinal edge. (5) Anastomotic obstruction by big purse of jejunal stump: When Roux-en-Y anastomosis is performed after distal radical operation for gastric cancer, anvil is placed in the remnant stomach and anastomat from distal jejunal stump is placed to make gastrojejunal anastomosis, and the stump is closed with big purse embedding. The embedding jejunal stump may enter gastric cavity leading to internal hernia and anastomotic obstruction. We suggest that application of interruptable and interlocking suture and fixation of stump on the gastric wall can avoid the development of this complication.
Anastomosis, Roux-en-Y
;
adverse effects
;
China
;
Chylous Ascites
;
etiology
;
prevention & control
;
therapy
;
Duodenum
;
blood supply
;
surgery
;
Gastrectomy
;
adverse effects
;
methods
;
mortality
;
Gastric Outlet Obstruction
;
etiology
;
prevention & control
;
Gastric Stump
;
surgery
;
Hemostatic Techniques
;
Hernia
;
etiology
;
prevention & control
;
therapy
;
High-Intensity Focused Ultrasound Ablation
;
instrumentation
;
Humans
;
Jejunum
;
blood supply
;
surgery
;
Lymph Node Excision
;
adverse effects
;
instrumentation
;
Lymphatic System
;
injuries
;
Postoperative Complications
;
classification
;
diagnosis
;
mortality
;
prevention & control
;
Prognosis
;
Stomach
;
surgery
;
Stomach Neoplasms
;
complications
;
surgery
;
Suture Techniques
;
standards
;
Thoracic Duct
;
injuries
;
Wound Closure Techniques
;
standards
4.Prevention of surgery-related complications of D2+ lymphadenectomy for gastric cancer.
Chinese Journal of Gastrointestinal Surgery 2017;20(2):140-143
D2 lymphadenectomy is currently the worldwide standard operation for locally advanced gastric cancer and D2+ is an option for some selected patients. The D2 plus lymphadenectomy includes No.8p, No.10, No.11d, No.12b, No.12p, No.13, No.14v, No.16a2 and No.16b1. Dissection of these groups of lymph nodes may cause related complications. Postoperative complications that can cause prolonged inflammation have significant impact not only on mortality but also on overall survival of patients with gastric cancer even if the tumor is resected curatively. D2 plus lymphadenectomy is recommended only in high volume medical center by experienced surgeon. The adequate exposure of the operative field, right anatomical space, use of ultrasound scalpel and operator with enough patience are proved to be pivotal to prevent the complications.
High-Intensity Focused Ultrasound Ablation
;
instrumentation
;
Humans
;
Inflammation
;
prevention & control
;
Long Term Adverse Effects
;
prevention & control
;
Lymph Node Excision
;
adverse effects
;
instrumentation
;
methods
;
mortality
;
Lymph Nodes
;
Postoperative Complications
;
prevention & control
;
Stomach Neoplasms
;
mortality
;
surgery
;
Surgical Instruments
5.High-intensity focused ultrasound combined with hysteroscopic resection to treat retained placenta accreta.
Jae Seong LEE ; Gi Youn HONG ; Byung Joon PARK ; Hyejin HWANG ; Rayon KIM ; Tae Eung KIM
Obstetrics & Gynecology Science 2016;59(5):421-425
We present a case of retained placenta accreta treated by high-intensity focused ultrasound (HIFU) ablation followed by hysteroscopic resection. The patient was diagnosed as submucosal myoma based on ultrasonography in local clinic. Pathologic examination of several pieces of tumor mass from the hysteroscopic procedure revealed necrotic chorionic villi with calcification. HIFU was performed using an ultrasound-guided HIFU tumor therapeutic system. The ultrasound machine had been used for real-time monitoring of the HIFU procedure. After HIFU treatment, no additional vaginal bleeding or complications were observed. A hysteroscopic resection was performed to remove ablated placental tissue 7 days later. No abnormal vaginal bleeding or discharge was seen after the procedure. The patient was stable postoperatively. We proposed HIFU and applied additional hysteroscopic resection for a safe and effective method for treating retained placenta accreta to prevent complications from the remaining placental tissue and to improve fertility options.
Chorionic Villi
;
Fertility
;
High-Intensity Focused Ultrasound Ablation
;
Humans
;
Methods
;
Myoma
;
Placenta, Retained*
;
Ultrasonography*
;
Uterine Hemorrhage
6.High-intensity focused ultrasound combined with hysteroscopic resection to treat retained placenta accreta.
Jae Seong LEE ; Gi Youn HONG ; Byung Joon PARK ; Hyejin HWANG ; Rayon KIM ; Tae Eung KIM
Obstetrics & Gynecology Science 2016;59(5):421-425
We present a case of retained placenta accreta treated by high-intensity focused ultrasound (HIFU) ablation followed by hysteroscopic resection. The patient was diagnosed as submucosal myoma based on ultrasonography in local clinic. Pathologic examination of several pieces of tumor mass from the hysteroscopic procedure revealed necrotic chorionic villi with calcification. HIFU was performed using an ultrasound-guided HIFU tumor therapeutic system. The ultrasound machine had been used for real-time monitoring of the HIFU procedure. After HIFU treatment, no additional vaginal bleeding or complications were observed. A hysteroscopic resection was performed to remove ablated placental tissue 7 days later. No abnormal vaginal bleeding or discharge was seen after the procedure. The patient was stable postoperatively. We proposed HIFU and applied additional hysteroscopic resection for a safe and effective method for treating retained placenta accreta to prevent complications from the remaining placental tissue and to improve fertility options.
Chorionic Villi
;
Fertility
;
High-Intensity Focused Ultrasound Ablation
;
Humans
;
Methods
;
Myoma
;
Placenta, Retained*
;
Ultrasonography*
;
Uterine Hemorrhage
7.Pain Palliation in Patients with Bone Metastases Using Magnetic Resonance-Guided Focused Ultrasound with Conformal Bone System: A Preliminary Report.
Bio JOO ; Mi Suk PARK ; Soo Hyeon LEE ; Hye Jin CHOI ; Seung Tack LIM ; Sun Young RHA ; Itay RACHMILEVITCH ; Young Han LEE ; Jin Suck SUH
Yonsei Medical Journal 2015;56(2):503-509
PURPOSE: We evaluated the safety and effectiveness of the Magnetic Resonance-guided Focused Ultrasound (MRgFUS) with the ExAblate Conformal Bone System for the palliation of painful bone metastases. MATERIALS AND METHODS: Our Institutional Review Board approved this study, and all patients gave informed consent prior to enrollment. A total of six painful metastatic bone lesions in five patients were treated using MRgFUS with the ExAblate Conformal Bone System for pain palliation. The follow-up sessions were at 3 days, 2 weeks, 1, 2, and 3 months, and 1 year after treatment. Efficacy was evaluated by the changes in visual analog scale (VAS) scores. At 3-months and 1-year follow-ups, unenhanced computed tomography and contrast-enhanced MR imaging examinations were performed. All adverse events were assessed to evaluate treatment safety. RESULTS: All patients showed significant pain relief within 2 weeks. Two patients experienced complete pain reduction that lasted for 1 year. Two other patients showed pain relief measured as VAS scores of 2 and 4 on their last follow-up. Although the remaining patient had experienced significant pain relief in two lesions, the VAS score re-increased on his last follow-up. The size of the enhancing soft tissue mass in metastatic lesions decreased, and new bone formation was seen on follow-up images. Although adverse events were not serious, non-specific leg pain and second degree skin burn were noted. CONCLUSION: MRgFUS was demonstrated to be effective palliative treatment within 2 weeks in selected patients with painful bone metastases.
Adult
;
Aged
;
Bone Neoplasms/secondary/*therapy
;
Contrast Media
;
Female
;
High-Intensity Focused Ultrasound Ablation/adverse effects/*methods
;
Humans
;
Magnetic Resonance Imaging, Interventional/*methods
;
Magnetic Resonance Spectroscopy
;
Male
;
Middle Aged
;
Pain
;
*Pain Management
;
*Palliative Care
;
Prospective Studies
;
Tomography, X-Ray Computed
;
Treatment Outcome
;
Young Adult
8.Pain Palliation in Patients with Bone Metastases Using Magnetic Resonance-Guided Focused Ultrasound with Conformal Bone System: A Preliminary Report.
Bio JOO ; Mi Suk PARK ; Soo Hyeon LEE ; Hye Jin CHOI ; Seung Tack LIM ; Sun Young RHA ; Itay RACHMILEVITCH ; Young Han LEE ; Jin Suck SUH
Yonsei Medical Journal 2015;56(2):503-509
PURPOSE: We evaluated the safety and effectiveness of the Magnetic Resonance-guided Focused Ultrasound (MRgFUS) with the ExAblate Conformal Bone System for the palliation of painful bone metastases. MATERIALS AND METHODS: Our Institutional Review Board approved this study, and all patients gave informed consent prior to enrollment. A total of six painful metastatic bone lesions in five patients were treated using MRgFUS with the ExAblate Conformal Bone System for pain palliation. The follow-up sessions were at 3 days, 2 weeks, 1, 2, and 3 months, and 1 year after treatment. Efficacy was evaluated by the changes in visual analog scale (VAS) scores. At 3-months and 1-year follow-ups, unenhanced computed tomography and contrast-enhanced MR imaging examinations were performed. All adverse events were assessed to evaluate treatment safety. RESULTS: All patients showed significant pain relief within 2 weeks. Two patients experienced complete pain reduction that lasted for 1 year. Two other patients showed pain relief measured as VAS scores of 2 and 4 on their last follow-up. Although the remaining patient had experienced significant pain relief in two lesions, the VAS score re-increased on his last follow-up. The size of the enhancing soft tissue mass in metastatic lesions decreased, and new bone formation was seen on follow-up images. Although adverse events were not serious, non-specific leg pain and second degree skin burn were noted. CONCLUSION: MRgFUS was demonstrated to be effective palliative treatment within 2 weeks in selected patients with painful bone metastases.
Adult
;
Aged
;
Bone Neoplasms/secondary/*therapy
;
Contrast Media
;
Female
;
High-Intensity Focused Ultrasound Ablation/adverse effects/*methods
;
Humans
;
Magnetic Resonance Imaging, Interventional/*methods
;
Magnetic Resonance Spectroscopy
;
Male
;
Middle Aged
;
Pain
;
*Pain Management
;
*Palliative Care
;
Prospective Studies
;
Tomography, X-Ray Computed
;
Treatment Outcome
;
Young Adult
9.Factors Affecting Tumor Ablation during High Intensity Focused Ultrasound Treatment.
Aizan HASSANUDDIN ; Jun Ho CHOI ; Dong Wan SEO ; Choong Heon RYU ; Su Hui KIM ; Do Hyun PARK ; Sang Soo LEE ; Sung Koo LEE ; Myung Hwan KIM
Gut and Liver 2014;8(4):433-437
BACKGROUND/AIMS: High intensity focused ultrasound (HIFU) utilizes a targeted extracorporeal focused ultrasound beam to ablate neoplastic pancreatic tissue. We used an in vitro model to examine the effects of bone, metallic stents, plastic stents, metal plates, and cyst-like lesions on HIFU treatment. METHODS: HIFU was delivered to the phantom models implanted with foreign bodies, and the location, shape, and size of the ablated zones were evaluated. RESULTS: Bone and metallic plates reflected the ultrasound beam, shifting the ablation zone from the focal zone to the prefocal area. In the phantoms containing metal stent, plastic stent, and cyst, most of the ablative energy was reflected to the prefocal area by the surface, with the remainder penetrating through the phantom. The area of the ablated margins was significantly larger in size and volume than the intended focal ablation zone. CONCLUSIONS: During HIFU therapy, artificial or anatomical barriers could affect the direction of the ultrasound beams, shifting the ablation zone from the focal area to a prefocal site with a larger than expected ablation zone. These factors should be considered prior to HIFU treatment for pancreatic tumors because they could limit ablation success, in addition to causing complications.
Adenocarcinoma/*therapy
;
High-Intensity Focused Ultrasound Ablation/*methods
;
Humans
;
Models, Anatomic
;
Pancreatic Neoplasms/*therapy
;
Phantoms, Imaging
;
Stents
10.Effect of ablations by pulsed versus continuous high-intensity focused ultrasound on isolated perfused porcine liver.
Jiao JIAO ; Feng WU ; Jianzhong ZOU ; Faqi LI ; Fang LIU ; Xin ZHAO ; Qi WANG
Journal of Southern Medical University 2013;33(2):230-234
OBJECTIVETo compare the effect of ablations with pulsed and continuous high-intensity focused ultrasound (HIFU) on the target area containing large blood vessels in isolated perfused porcine liver.
METHODSAn isolated perfused liver model was established by perfusing the isolated porcine liver with autologous blood through the portal vein and hepatic artery using an cardiopulmonary bypass machine. With B-mode ultrasound guidance, a blood vessel about 4 mm in diameter was selected, and pulsed and continuous HIFU ablation at the same dose was delivered along the blood vessel at 3 mm to the vascular wall. After the ablation, the damages of the blood vessels as the acoustic channel and the target area were inspected, and the tissues at the interface of target volume and blood vessels were sampled for pathological examination.
RESULTSNeither pulsed nor continuous HIFU caused noticeable injuries of the acoustic channel vessels, but the volume of necrotic tissues in the target area differed significantly between the two groups (P<0.05). HE staining and vessel staining did not show any injuries of the blood vessels in the pathway of ultrasound ablation in neither of the groups (P>0.05).
CONCLUSIONWhen the target area contains large blood vessels in the pathway of ultrasound ablation, pulsed HIFU can have better therapeutic efficiency to effectively induce tissue damages without affecting the blood vessels.
Animals ; Disease Models, Animal ; Extracorporeal Circulation ; Hepatic Artery ; pathology ; Hepatic Veins ; pathology ; High-Intensity Focused Ultrasound Ablation ; adverse effects ; methods ; Liver ; pathology ; Swine

Result Analysis
Print
Save
E-mail