1.Construction of key nursing technology system for hospital treatment of patients with nuclear radiation exposure
Xianjing HU ; Yan YAN ; Jing WANG ; Heli ZHANG ; Yamei CHEN ; Li MA ; Rongmei GENG ; Baohua LI
Chinese Journal of Nursing 2024;59(1):57-63
Objective To construct a key nursing technology system for the treatment of patients exposed to nuclear radiation in hospitals,and provide technical guidance and support for emergency nursing rescue in hospitals of nuclear radiation accidents.Methods A research group was composed of a team with rich experience in nuclear radiation accidents.Based on 4 scenarios of nuclear radiation accidents(including external irradiation,internal irradiation,external contamination,internal contamination),the literature search was conducted to form the first draft of the system.Delphi method was used to complete 2 rounds of expert letter consultation,and the final draft of the key nursing technology system for hospital treatment of patients with nuclear radiation exposure was constructed according to the revised opinions of experts.Results A total of 16 experts completed 2 rounds of correspondence.The effective recovery rates were 100%and 80%;the recommendation rates were 65%and 50%;the authority coefficients(Cr)were 0.778 and 0.797;the coefficient of variation(CV)of the 2 rounds of expert letter consultation was ≤0.25.Finally,a key nursing technology system for in-hospital treatment of patients with nuclear radiation exposure was formed,including 5 first-level indicators,26 second-level indicators and 74 third-level indicators.Conclusion The constructed key nursing technology system for hospital treatment of patients with nuclear radiation exposure is highly practical and scientific,and it is conducive to the formation of standardized nuclear radiation exposure treatment procedures,and provides a theoretical basis for the training and evaluation of nursing staff related to nuclear radiation exposure.
2.Determination of 16 bisphenols in drinking water by online solid-phase extraction-ultra high-performance liquid chromatography tandem mass spectrometry
Chaoye SHEN ; Saifeng PEI ; Yuhang CHEN ; Heli CHENG ; Yun ZHANG
Journal of Environmental and Occupational Medicine 2024;41(10):1173-1179
Background Bisphenol compounds are non-persistent environmental endocrine disruptors and frequently detected in drinking water systems, indicating potential human health risks through drinking water. Objective To establish and optimize a simultaneous determination method for 16 BPs in drinking water by online solid-phase extraction-ultra high-performance liquid chromatography-triple quadrupole mass spectrometry, in order to efficiently monitoring BPs in drinking water. Methods Candidate online solid-phase extraction conditions, chromatographic columns, mobile phase systems, mass spectrometry parameters, and other conditions were compared by chromatographic peaks of BPs, and processing conditions such as water sample preservation and pretreatment were optimized. The pH level of drinking water samples was adjusted and solid particles were removed. After extraction and purification by an online solid-phase extraction system, samples were detected by ultra-high performance liquid chromatography tandem mass spectrometry and quantified by isotope internal standard method. The proposed method was verified by pure water and terminal tap water, and evaluated by spiked recovery rate and relative standard deviation. Eighty-eight tap water samples from different regions of local pipeline network were collected for method application. Results For the 16 BPs, the calibration curves showed good linearity between 1.0 and 75 ng·L−1 and the correlation coefficients were greater than 0.995. The detection limit of the method was less than 0.30 ng·L−1, and the quantification limit of the method was less than 1.0 ng·L−1. When the spiked concentrations for the 16 BPs were 5.0, 15, and 40 ng·L−1, the average spiked recovery rates of the test substances were between (100 ± 10)%, and the relative standard deviations were all below 10%. In the method application to the local terminal water samples, the positive rates of bisphenol S (BPS), bisphenol A (BPA), and bisphenol AF (BPAF) were as high as 93.2%, 77.3%, and 29.5%, respectively. The concentrations of BPS were from not detected (N.D.) to 37.8 ng·L−1, and the concentrations of BPA were from N.D. to 52.0 ng·L−1. Conclusion The method using an online solid-phase extraction system is established, featuring simple pre-treatment, small sample volume, high degree of automation, low detection limit, and good accuracy and precision. This method can be applied to the quantitative monitoring of 16 BPs at ng·L−1 level in drinking water.
3.Interaction analysis of mismatch repair protein and adverse clinicopathological features on prognosis of colon cancer
Kexuan LI ; Fuqiang ZHAO ; Qingbin WU ; Junling ZHANG ; Shuangling LUO ; Shidong HU ; Bin WU ; Heli LI ; Guole LIN ; Huizhong QIU ; Junyang LU ; Lai XU ; Zheng WANG ; Xiaohui DU ; Liang KANG ; Xin WANG ; Ziqiang WANG ; Qian LIU ; Yi XIAO
Chinese Journal of Digestive Surgery 2024;23(6):826-835
Objective:To investigate the interactive effect of mismatch repair (MMR) protein status and adverse clinicopathological features on prognosis of stage Ⅰ-Ⅲ colon cancer.Methods:The retrospective cohort study was conducted. The clinicopathological data of 1 650 patients with colon cancer of stage Ⅰ-Ⅲ who were admitted to 7 hospitals in China from January 2016 to December 2017 were collected. There were 963 males and 687 females, aged 62(53,71)years. Patients were classified as 230 cases of MMR deficiency (dMMR) and 1 420 cases of MMR proficiency (pMMR) based on their MMR protein status. Observation indicators: (1) comparison of clinicopathological characteristics between patients of different MMR protein status; (2) analysis of factors affecting the survival outcomes of patients of dMMR; (3) analysis of factors affecting the survival outcomes of patients of pMMR; (4) interaction analysis of MMR and adverse clinicopathological features on survival outcomes. Measurement data with normal distribution were represented as Mean± SD, and comparison between groups was conducted using the independent t test. Measurement data with skewed distribution were represented as M( Q1, Q3), and comparison between groups was conducted using the Mann-Whitney U test. Count data were described as absolute numbers, and comparison between groups was conducted using the chi-square test or Fisher exact probability. Comparison of ordinal data was conducted using the Mann-Whitney U test. The random forest interpolation method was used for missing values in data interpolation. Univariate analysis was conducted using the COX proportional risk regression model, and multivariate analysis was conducted using the COX stepwise regression with forward method. The coefficient of multiplication interaction effect was obtained using the interaction term coefficient of COX proportional risk regression model. Evaluation of additive interaction effects was conducted using the relative excess risk due to interaction ( RERI). Results:(1) Comparison of clinicopathological characteristics between patients of different MMR protein status. There were significant differences in age, T staging, the number of lymph node harvest, the number of lymph node harvest <12, high grade tumor between patients of dMMR and pMMR ( P<0.05). (2) Analysis of factors affecting the survival outcomes of patients of dMMR. Results of multivariate analysis showed that T staging, N staging, the number of lymph node harvest <12 were independent factors affecting the disease-free survival (DFS) of colon cancer patients of dMMR ( hazard ratio=3.548, 2.589, 6.702, 95% confidence interval as 1.460-8.620, 1.064-6.301, 1.886-23.813, P<0.05). Age and N staging were independent factors affecting the overall survival (OS) of colon cancer patients of dMMR ( hazard ratio=1.073, 10.684, 95% confidence interval as 1.021-1.126, 2.311-49.404, P<0.05). (3) Analysis of factors affecting the survival outcomes of patients of pMMR. Results of multivariate analysis showed that age, T staging, N staging, vascular tumor thrombus were independent factors affecting the DFS of colon cancer patients of pMMR ( hazard ratio=1.018, 2.214, 2.598, 1.549, 95% confidence interval as 1.006-1.030, 1.618-3.030, 1.921-3.513, 1.118-2.147, P<0.05). Age, T staging, N staging, high grade tumor were independent factors affecting the OS of colon cancer patients of pMMR ( hazard ratio=1.036, 2.080, 2.591, 1.615, 95% confidence interval as 1.020-1.052, 1.407-3.075, 1.791-3.748, 1.114-2.341, P<0.05). (4) Interaction analysis of MMR and adverse clinicopathological features on survival outcomes. Results of interaction analysis showed that the multiplication interaction effect between the number of lymph node harvest <12 and MMR protein status was significant on DFS of colon cancer patients ( hazard ratio=3.923, 95% confidence interval as 1.057-14.555, P<0.05). The additive interaction effects between age and MMR protein status, between high grade tumor and MMR protein status were significant on OS of colon cancer patients ( RERI=-0.033, -1.304, 95% confidence interval as -0.049 to -0.018, -2.462 to -0.146). Conclusions:There is an interaction between the MMR protein status and the adverse clinicopathological features (the number of lymph node harvest <12, high grade tumor) on prognosis of colon cancer patients of stage Ⅰ-Ⅲ. In patients of dMMR, the number of lymph node harvest <12 has a stronger predictive effect on poor prognosis. In patients of pMMR, the high grade tumor has a stronger predictive effect on poor prognosis.
4.Construction of structured education course for patients with neurogenic bladder during rehabilitation period
Heli ZHANG ; Xianjing HU ; Hongle DAI ; Shuyu HAN ; Yongmei LUO ; Rongmei GENG ; Baohua LI
Chinese Journal of Modern Nursing 2024;30(25):3416-3423
Objective:To construct a structured education course for patients with neurogenic bladder during the rehabilitation period.Methods:This study consisted three stages of current situation survey, literature search, and expert consultation. From February 2022 to February 2023, a current survey was conducted on the self-management needs of 62 patients with neurogenic bladder. In April 2023, a literature search was conducted to summarize the best evidence on nursing and management of neurogenic bladder, and form the initial version of course indicators and content. From April to May 2023, 14 experts were selected for consultation, and the Delphi method was used to demonstrate the course indicators and content, and to construct the final draft of the course.Results:A total of 62 patients with neurogenic bladder were included, they have requirements for water management, bladder function training, and dietary requirements, etc. A total of 2 053 articles were retrieved, and 14 articles were ultimately included, including eight guidelines, four evidence summaries, one expert consensus, and one systematic review. The expert authority coefficients for the two rounds of expert consultation were 0.93 and 0.92, respectively. The Kendall coordination coefficient of various indicators in the second round of expert consultation was 0.227 to 0.288 ( P<0.01). After two rounds of expert consultation, a structured education course for patients with neurogenic bladder during the rehabilitation period was finally developed, including six primary indicators, 21 secondary indicators, and 30 tertiary indicators. Conclusions:The structured education course for patients with neurogenic bladder during the rehabilitation period, based on current situation survey, high-quality evidence, and expert consultation, is comprehensive in content and reasonably designed, which can provide supportive assistance for future nursing health education and management for patients with neurogenic bladder.
5.Application of optical surface monitoring system guided volumetric modulated arc therapy in total body irradiation
Zhuangling LI ; Heli ZHONG ; Yan GAO ; Longxing LI ; Yabin SHI ; Xiaonian DENG ; Xin FU ; Ding ZHANG ; Fang ZHENG ; Hongtao CHEN ; Weisi CHEN
Chinese Journal of Medical Physics 2024;41(9):1070-1077
Objective To establish a novel clinical application process of the optical surface monitoring system(OSMS)guided volumetric modulated arc therapy(VMAT)for total body irradiation(TBI),and to assess the accuracy and effectiveness of OSMS in inter-fractional auxiliary positioning before radiotherapy and real-time monitoring of intra-fractional motion during radiotherapy.Methods A retrospective analysis was conducted on 15 leukemia patients who underwent OSMS-guided VMAT-TBI before hematopoietic stem cell transplantation.CT simulation positioning was performed,and the whole-body image data which were collected in head-first supine position(HFS)and feet-first supine position(FFS)were transmitted to the treatment planning system for image registration,multicenter VMAT planning and dose verification.The prescription dose was 800 cGy in 4 fractions twice daily.OSMS was used to assist positioning before delivery,and CBCT was used for position verification.During treatment,OSMS was used for monitoring.The intra-fractional error monitored by OSMS in real time was obtained by analyzing the offline log files.Results The mean dose and coverage of the target area in HFS plan were(905.4±19.0)cGy and 93.0%±2.8%.The mean doses to lung and kidney were(603.7±55.7)cGy and(600.4±49.6)cGy,respectively,and the maximum dose to the lens was(393.9±58.9)cGy.The mean dose and coverage of the target area in FFS plan were(888.5±58.9)cGy and 94.0%±3.2%;and the maximum dose at the junction was(1148.9±72.9)cGy.Fractional treatment delivery time was(75.1±15.1)min.OSMS-assisted positioning was carried out before delivery,and the total deviations of CBCT three-dimensional vector in translational and rotation directions were(2.71±1.96)mm and 0.91°±0.90°,respectively.The three-dimensional vector deviation of the intra-fractional motion amplitude in translational direction monitored by OSMS during the treatment was(1.95±1.88)mm,of which the deviation within 1 mm accounted for 57.5%,79.7%and 62.1%in longitudinal,lateral and vertical directions,respectively.The three-dimensional vector deviation in rotation direction was 0.76°±0.72°,of which the deviation within 1°accounted for 93.1%,85.7%and 94.3%in rotation,pitch and roll directions,respectively.Conclusion VMAT simplifies TBI process,while improving target coverage and organs-at-risk sparing.The use of OSMS can reduce positioning errors,especially rotation errors.In order to ensure the accurate implementation of TBI and the safety of patients,it is necessary to use OSMS for auxiliary positioning and intra-fractional position monitoring.
6.Effect of Different Noise Index and Adaptive Statistical Interactive Reconstruction-Veo Selection on Double Energy CT
Han ZHANG ; Tiantian YIN ; Qiushi YANG ; Zeguo WANG ; Heli HAN ; Wanjiang YU
Chinese Journal of Medical Imaging 2024;32(10):1069-1074
Purpose Based on European lumbar spine phantom,to investigate the effect of different noise index(NI)combined with adaptive statistical interactive reconstruction-veo(ASiR-V)weights on the measurement of lumbar spine bone density,and to explore the optimal combination of the two parameters.Materials and Methods Using GE Revolution CT spectral imaging scanning,54 groups of scanning parameters with NI values of 4-20(interval 2)combined with ASiR-V weights of 0-100%(interval 20%)were selected for spectral scanning of European lumbar spine phantom.Regions of interest were placed in the middle of L1,L2 and L3,respectively.hydroxyapatite(HAP)-H2O based substances were selected to measure the HAP content of each vertebral body.The differences between the measured bone density value and the true value under different NI combined with different ASiR-V were compared to evaluate its accuracy.Results There were statistically significant differences in HAP measurements of L1,L2 and L3 vertebra in 54 groups of scanning conditions(all P<0.001).When NI=14,ASiR-V80%;NI=16,ASiR-V100%;NI=18,ASiR-V60%;NI=18,ASiR-V80%;NI=20,ASiR-V60%;NI=20,ASiR-V80%;NI=20,ASiR-V100%,there was no statistically significant difference between HAP measured value and true body model value(P>0.05).Conclusion With NI=18,ASiR-V60%,spectral CT can accurately measure lumbar spine bone density and significantly reduce the radiation dose.In clinical application,bone density can be measured by low dose scanning by increasing the weight of NI and ASiR-V.
7.A qualitative study on the suggestion of key nursing techniques and procedure optimization by medical staffs for patients with nuclear exposed in hospital
Heli ZHANG ; Yan YAN ; Xianjing HU ; Yamei CHEN ; Jing WANG ; Baohua LI
Chinese Journal of Practical Nursing 2023;39(6):458-462
Objective:To understand the views and suggestions of medical staff on the key nursing techniques and norms of in-hospital treatment of patients with nuclear exposure, so as to provide reference for the continuous optimization of follow-up processes.Methods:From September to October 2021,purpose sampling was adopted to select doctors and nurses who engaged in medical emergency rescue of nuclear exposure-related work in two divisions of the Nuclear Accident Medical Emergency Center of the National Health Commission as the research subjects, using a combination of online and offline methods to carry out semi-structured interviews with 6 research subjects,using content analysis methods in descriptive research for data analysis.Results:A total of four themes were refined including the need for the establishment of nursing technology and process specification for nuclear accident emergency rescue specialty; the need for specialized training of nursing technology in nuclear accident emergency rescue; the need for the construction of specialized nursing team for nuclear accident emergency rescue; the need to strengthen the closeness of multi-team cooperation.Conclusions:The current in-hospital care technology and processes for nuclear exposed patients need to be further refined and standardized, and in the future, we need to establish a perfect in-hospital care technology and processes for nuclear exposed patients, and according to the corresponding technology and processes, strengthen nursing staff professional training and simulation training in nuclear accident emergency rescue, and establish a nuclear emergency rescue professional nursing team to promote the development of nuclear accident emergency rescue nursing specialists.
8.What Frequency of Ankle Pump Exercise is Optimal to Improve Lower Limb Hemodynamics? A Systematic Review and Network Metaanalysis
Xin WANG ; Rongsong TANG ; Heli ZHANG ; Fan LI ; Jing WANG ; Baohua LI
Asian Nursing Research 2023;17(2):53-60
Purpose:
Ankle pump exercises (APE) have been widely used in clinical practice. However, best practices for APE have not been established. Recognize the most effective frequency of APE for improving lower extremity hemodynamics and establish recommendations in clinical practice.
Methods:
Therefore, a systematic review and network meta-analysis (NMA) was performed according to PRISMA-NMA. Six English databases (Pubmed, Medline, CINAHL, Embase, the Cochrane library and ProQuest) and four Chinese databases (CNKI, Wanfang, VIP and Sinomed) were searched. Randomized controlled trials (RCTs) and quasi-experimental studies investigating the effects of different frequencies of APE on lower limb hemodynamics published before July 2022 were included. The reference list was also searched. Seven studies (one RCTs and six quasi-experimental studies) were included in the systematic review and five studies (one RCTs and four quasi-experimental studies) were included in the NMA. The risk of bias was assessed using the Cochrane and Joanna Briggs Institute tools. The NMA was performed using the R software (version 4.2.1) and OpenBUGS (version 3.2.3).
Results:
The results of the NMA showed that a frequency of every 3–4 s the most effective in improving lower extremity hemodynamics (P =.85), followed by every 1–2 s (P = .81), every 5–6 s (P=.32) and less than every 10 s (P =.02). Subgroup analysis failed to find a difference between healthy participants and those with unilateral total hip arthroplasty or fracture (MD = −0.23, 95% CI-5.92 to 4.61).
Conclusions
Consequencely, for adult patients, with or without lower extremity disease, a frequency of every 3–4 s can be recommended as the optimal frequency of APE in clinical care practice.Registered number on PROSPEROCRD42022349365. https://www.crd.york.ac.uk/PROSPERO/display_record.php?RecordID=349365.
9.Construction of competency assessment system for nutrition support specialist nurses
Xin WANG ; Heli ZHANG ; Rongsong TANG ; Xiaoyan GUO ; Rongmei GENG ; Baohua LI
Chinese Journal of Modern Nursing 2023;29(15):1991-1996
Objective:To establish a competency assessment system for nutritional support specialist nurses, so as to provide reference basis for training reform, functional performance, and improvement of nursing service quality for nutritional support specialist nurses.Methods:Based on the practice standards of nutrition support specialist nurses published by American Society for Parenteral and Enteral Nutrition, the draft of the competency assessment system for nutrition support specialist nurses was developed through literature search and group discussion. From November 2021 to February 2022, two rounds of expert letter consultation were conducted with 15 experts by Delphi method, indicators were screened and modified according to expert suggestions, and the final competency assessment system for nutrition support specialist nurses was formed.Results:The effective response rates of the two rounds of expert inquiry questionnaires were 93.3% (14/15) and 100.0% (15/15) , with expert authority coefficients of 0.922 and 0.917, respectively. In the first round of expert consultation, 50.0% (3/6) of the first-level indicators agreed with a percentage≥80.0%, and 64.9% (24/37) of the second-level indicators agreed with a percentage≥80.0%. In the second round of expert letter consultation, the agreement percentage of the first and second indicators were≥80.0%. The final competency assessment system for nutrition support specialist nurses included 6 first-level indicators (practical ability, communication and coordination ability, education and consultation ability, legal and ethical decision-making ability, scientific research ability, leadership) and 29 second-level indicators.Conclusions:The competency assessment system for nutritional support specialist nurses constructed in this study is scientific, reasonable, and highly reliable, which can be used to standardize the training process of nutritional support specialist nurses, promote personal development.
10.Application of optical surface monitoring system in intra-fraction motion monitoring in frameless cranial stereotactic radiotherapy
Yan GAO ; Xiaomin LIANG ; Ding ZHANG ; Hegou WU ; Zhuangling LI ; Xiongbo XU ; Yanwan ZHANG ; Heli ZHONG
Chinese Journal of Radiological Medicine and Protection 2022;42(4):283-290
Objective:To establish a novel clinical application process of the optical surface monitoring system (OSMS) in the cranial frameless stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT), and to assess the accuracy and effectiveness of the OSMS in the intra-fraction motion monitoring of both cranial phantoms and cranial SRT patients fixed using the Q-Fix encompass immobilization system.Methods:The deviations of OSMS in the real-time motion monitoring were assessed by determining the deviations between the displacement of the cranial SRS phantoms detected by the OSMS and the predefined displacement of the Varian Edge six degrees of freedom (6DoF) couch. The ability of the OSMS to conduct real-time monitoring of the head movement was also analyzed when one camera was blocked by the rotary gantry of the accelerator and when the couch was at non-zero angles. Moreover, ten patients who received 50 fractions of cranial frameless SRT were enrolled in this study. All the patients were fixed using the Q-Fix Encompass system, and their intra-fraction motion was monitored using the OSMS. The intra-fraction errors of OSMS real-time monitoring throughout the treatment were obtained from the OSMS logs. The patients received cone-beam computed tomography (CBCT) after the beam delivery, and the six-dimensional errors were obtained as intra-fraction motion errors of the CBCT.Results:For the cranial phantoms, there was a close correlation between the OSMS monitoring deviations and the predefined displacement in six dimensions. The OSMS-detected 3D vector deviations in the translational and rotational directions were (0.28±0.10) mm and (0.15±0.09)°, respectively when the angel both the gantry and couch was 0° and were (0.35±0.13) mm and(0.17±0.09)°, respectively, when one camera was blocked. The OSMS monitoring deviations with the couch at a non-zero degree were greater than those at zero degree. The maximum deviations occurred when the couch was at 270° and were (0.69±0.19) mm and (0.32±0.12)°, respectively, in the translational and rotational directions. For the cranial SRT patients fixed using the Q-Fix Encompass system, the OSMS and CBCT showed comparable intra-fractional motion deviations, which were (0.40±0.26) and (0.29±0.10) mm, respectively in the translational direction and were (0.33±0.20)°and (0.26±0.08)° in the rotational direction.Conclusions:The OSMS is an effective tool for optically guided radiotherapy, which allows for intra-fraction real-time motion monitoring with sub-millimeter accuracy. Therefore, to ensure the accurate preformation of cranial SRS/SRT, it is necessary to conduct the intra-fractional position monitoring using OSMS.

Result Analysis
Print
Save
E-mail