1.Post‑transplant cyclophosphamide plus anti‑thymocyte globulin decreased serum IL‑6 levels when compared with post‑transplant cyclophosphamide alone after haploidentical hematopoietic stem cell transplantation
Jeong Suk KOH ; Myung‑Won LEE ; Thi Thuy Duong PHAM ; Bu Yeon HEO ; Suyoung CHOI ; Sang‑Woo LEE ; Wonhyoung SEO ; Sora KANG ; Seul Bi LEE ; Chul Hee KIM ; Hyewon RYU ; Hyuk Soo EUN ; Hyo‑Jin LEE ; Hwan‑Jung YUN ; Deog‑Yeon JO ; Ik‑Chan SONG
Blood Research 2025;60():5-
Background:
Post-transplantation cyclophosphamide (PTCy) and anti-thymocyte globulin (ATG) are common pro‑ phylactic strategies for graft-versus-host disease (GVHD) after haploidentical hematopoietic stem cell transplantation (haplo-HSCT). Interleukin (IL)-6 is a surrogate marker for cytokine release syndrome (CRS) and acute GVHD.Method The clinical outcomes and complications of haplo-HSCT with PTCy plus ATG versus PTCy monotherapy were compared according to serum IL-6 levels at Chungnam National University Hospital (Daejeon, South Korea) from Jan‑ uary 2019 to February 2023.
Results:
Forty patients who underwent haplo-HSCT were analyzed. A significant difference in IL-6 levels was observed between the PTCy plus ATG and PTCy alone groups (7.47 ± 10.55 vs. 117.65 ± 127.67; p = 0.003). More patients in the PTCy plus ATG group had a CRS grade of 0 than in the PTCy alone group (p < 0.001). Serum IL-6 levels were associated with grades II–IV acute GVHD (r = 0.547, p < 0.001). The cumulative incidence (CI) of grades II–IV acute GVHD was significantly higher in the PTCy alone group (67.9% vs. 4.8%; p < 0.001). No significant difference in the CI for chronic GVHD was detected between the PTCy plus ATG and PTCy alone groups (72.1% vs. 82.0%; p = 0.730). The CI of 1-year non-relapse mortality was significantly higher in the PTCy alone group than in the PTCy plus ATG group (42.2% vs. 15.9%; p = 0.022). The 1-year overall survival (OS) was significantly better in the PTCy plus ATG group (75.9% vs. 35.3%; p = 0.011). The 1-year GVHD-free, relapse-free survival rate was 29.4% in the PTCy alone group and 54.0% in the PTCy plus ATG group (p = 0.038).
Conclusion
Serum IL-6 levels were higher in the PTCy alone group than in the PTCy plus ATG group. The addition of ATG before stem cell infusion affected IL-6 levels and reduced the incidences of CRS and grade II–IV acute GVHD in haplo-HSCT patients. This study suggests that PTCy plus ATG as GVHD prophylaxis in haplo-HSCT is beneficial in terms of clinical outcomes and complications of HSCT.
2.Post‑transplant cyclophosphamide plus anti‑thymocyte globulin decreased serum IL‑6 levels when compared with post‑transplant cyclophosphamide alone after haploidentical hematopoietic stem cell transplantation
Jeong Suk KOH ; Myung‑Won LEE ; Thi Thuy Duong PHAM ; Bu Yeon HEO ; Suyoung CHOI ; Sang‑Woo LEE ; Wonhyoung SEO ; Sora KANG ; Seul Bi LEE ; Chul Hee KIM ; Hyewon RYU ; Hyuk Soo EUN ; Hyo‑Jin LEE ; Hwan‑Jung YUN ; Deog‑Yeon JO ; Ik‑Chan SONG
Blood Research 2025;60():5-
Background:
Post-transplantation cyclophosphamide (PTCy) and anti-thymocyte globulin (ATG) are common pro‑ phylactic strategies for graft-versus-host disease (GVHD) after haploidentical hematopoietic stem cell transplantation (haplo-HSCT). Interleukin (IL)-6 is a surrogate marker for cytokine release syndrome (CRS) and acute GVHD.Method The clinical outcomes and complications of haplo-HSCT with PTCy plus ATG versus PTCy monotherapy were compared according to serum IL-6 levels at Chungnam National University Hospital (Daejeon, South Korea) from Jan‑ uary 2019 to February 2023.
Results:
Forty patients who underwent haplo-HSCT were analyzed. A significant difference in IL-6 levels was observed between the PTCy plus ATG and PTCy alone groups (7.47 ± 10.55 vs. 117.65 ± 127.67; p = 0.003). More patients in the PTCy plus ATG group had a CRS grade of 0 than in the PTCy alone group (p < 0.001). Serum IL-6 levels were associated with grades II–IV acute GVHD (r = 0.547, p < 0.001). The cumulative incidence (CI) of grades II–IV acute GVHD was significantly higher in the PTCy alone group (67.9% vs. 4.8%; p < 0.001). No significant difference in the CI for chronic GVHD was detected between the PTCy plus ATG and PTCy alone groups (72.1% vs. 82.0%; p = 0.730). The CI of 1-year non-relapse mortality was significantly higher in the PTCy alone group than in the PTCy plus ATG group (42.2% vs. 15.9%; p = 0.022). The 1-year overall survival (OS) was significantly better in the PTCy plus ATG group (75.9% vs. 35.3%; p = 0.011). The 1-year GVHD-free, relapse-free survival rate was 29.4% in the PTCy alone group and 54.0% in the PTCy plus ATG group (p = 0.038).
Conclusion
Serum IL-6 levels were higher in the PTCy alone group than in the PTCy plus ATG group. The addition of ATG before stem cell infusion affected IL-6 levels and reduced the incidences of CRS and grade II–IV acute GVHD in haplo-HSCT patients. This study suggests that PTCy plus ATG as GVHD prophylaxis in haplo-HSCT is beneficial in terms of clinical outcomes and complications of HSCT.
3.Post‑transplant cyclophosphamide plus anti‑thymocyte globulin decreased serum IL‑6 levels when compared with post‑transplant cyclophosphamide alone after haploidentical hematopoietic stem cell transplantation
Jeong Suk KOH ; Myung‑Won LEE ; Thi Thuy Duong PHAM ; Bu Yeon HEO ; Suyoung CHOI ; Sang‑Woo LEE ; Wonhyoung SEO ; Sora KANG ; Seul Bi LEE ; Chul Hee KIM ; Hyewon RYU ; Hyuk Soo EUN ; Hyo‑Jin LEE ; Hwan‑Jung YUN ; Deog‑Yeon JO ; Ik‑Chan SONG
Blood Research 2025;60():5-
Background:
Post-transplantation cyclophosphamide (PTCy) and anti-thymocyte globulin (ATG) are common pro‑ phylactic strategies for graft-versus-host disease (GVHD) after haploidentical hematopoietic stem cell transplantation (haplo-HSCT). Interleukin (IL)-6 is a surrogate marker for cytokine release syndrome (CRS) and acute GVHD.Method The clinical outcomes and complications of haplo-HSCT with PTCy plus ATG versus PTCy monotherapy were compared according to serum IL-6 levels at Chungnam National University Hospital (Daejeon, South Korea) from Jan‑ uary 2019 to February 2023.
Results:
Forty patients who underwent haplo-HSCT were analyzed. A significant difference in IL-6 levels was observed between the PTCy plus ATG and PTCy alone groups (7.47 ± 10.55 vs. 117.65 ± 127.67; p = 0.003). More patients in the PTCy plus ATG group had a CRS grade of 0 than in the PTCy alone group (p < 0.001). Serum IL-6 levels were associated with grades II–IV acute GVHD (r = 0.547, p < 0.001). The cumulative incidence (CI) of grades II–IV acute GVHD was significantly higher in the PTCy alone group (67.9% vs. 4.8%; p < 0.001). No significant difference in the CI for chronic GVHD was detected between the PTCy plus ATG and PTCy alone groups (72.1% vs. 82.0%; p = 0.730). The CI of 1-year non-relapse mortality was significantly higher in the PTCy alone group than in the PTCy plus ATG group (42.2% vs. 15.9%; p = 0.022). The 1-year overall survival (OS) was significantly better in the PTCy plus ATG group (75.9% vs. 35.3%; p = 0.011). The 1-year GVHD-free, relapse-free survival rate was 29.4% in the PTCy alone group and 54.0% in the PTCy plus ATG group (p = 0.038).
Conclusion
Serum IL-6 levels were higher in the PTCy alone group than in the PTCy plus ATG group. The addition of ATG before stem cell infusion affected IL-6 levels and reduced the incidences of CRS and grade II–IV acute GVHD in haplo-HSCT patients. This study suggests that PTCy plus ATG as GVHD prophylaxis in haplo-HSCT is beneficial in terms of clinical outcomes and complications of HSCT.
4.The Accuracy of Implant Placement According to the Height of the Surgical Guide Hole
Kyu Won PARK ; Jihun CHA ; Seunggon JUNG ; Min‑Suk KOOK ; Hong-Ju PARK ; Hee-Kyun OH ; Jaeyoung RYU
Journal of Korean Dental Science 2024;17(4):201-209
Purpose:
This study investigated the impact of the guide hole height on the accuracy of implant placement using CAD/ CAM-fabricated surgical guides in resin models. The hypothesis is that decreasing the height of the guide hole reduces placement accuracy.
Materials and Methods:
Ten identical partially edentulous maxillary models were each fitted with surgical guides featuring guide hole heights of 1 mm, 3 mm, and/or 5 mm. Using a surgical guide and drill kit, implants were placed in six predetermined sites per model. Placement accuracy was evaluated by comparing the actual implant positions with the planned positions using digital scanning and computer software analysis. Statistical analyses were performed using ANOVA and Kruskal-Wallis tests to determine the significance of deviations at both the coronal and apical positions.
Results:
The average deviations were 0.75±0.33 mm at the coronal position and 1.10±0.51 mm at the apical position. Placement accuracy didnot differ with different guide hole heights. Additionally, errors were consistent regardless of the guide hole height and were not influenced by the type of support or the implant placement site.
Conclusion
In this rotro study, varying the height of the guide hole did not significantly affect the accuracy of implant placement. The results suggest that guide hole height within the tested range does not have a substantial impact on placement errors. Our findings indicate that factors other than the guide holeheight may play a more critical role in implant placement accuracy.
5.The Accuracy of Implant Placement According to the Height of the Surgical Guide Hole
Kyu Won PARK ; Jihun CHA ; Seunggon JUNG ; Min‑Suk KOOK ; Hong-Ju PARK ; Hee-Kyun OH ; Jaeyoung RYU
Journal of Korean Dental Science 2024;17(4):201-209
Purpose:
This study investigated the impact of the guide hole height on the accuracy of implant placement using CAD/ CAM-fabricated surgical guides in resin models. The hypothesis is that decreasing the height of the guide hole reduces placement accuracy.
Materials and Methods:
Ten identical partially edentulous maxillary models were each fitted with surgical guides featuring guide hole heights of 1 mm, 3 mm, and/or 5 mm. Using a surgical guide and drill kit, implants were placed in six predetermined sites per model. Placement accuracy was evaluated by comparing the actual implant positions with the planned positions using digital scanning and computer software analysis. Statistical analyses were performed using ANOVA and Kruskal-Wallis tests to determine the significance of deviations at both the coronal and apical positions.
Results:
The average deviations were 0.75±0.33 mm at the coronal position and 1.10±0.51 mm at the apical position. Placement accuracy didnot differ with different guide hole heights. Additionally, errors were consistent regardless of the guide hole height and were not influenced by the type of support or the implant placement site.
Conclusion
In this rotro study, varying the height of the guide hole did not significantly affect the accuracy of implant placement. The results suggest that guide hole height within the tested range does not have a substantial impact on placement errors. Our findings indicate that factors other than the guide holeheight may play a more critical role in implant placement accuracy.
6.Evaluation of Factors Influencing Maxillary Sinus Floor Augmentation for Implant Placement: A Retrospective Study
Jihun CHA ; Jaeyoung RYU ; Seunggon JUNG ; Hong-Ju PARK ; Hee-Kyun OH ; Min-Suk KOOK
Journal of implantology and applied sciences 2024;28(2):77-87
Purpose:
This retrospective study compared the maxillary sinus floor augmentation techniques (lateral and transcrestal approaches) to assess the impact of bone grafting, graft materials, and initial residual bone height (RBH). Materials and Methods: Fifty patients who underwent maxillary sinus floor augmentation for posterior maxillary implant placement were included. Panoramic radiographs were obtained before surgery (T0), immediately after surgery (T1), and 6-10 months post-surgery (T2). Length measurements on panoramic radiographs were performed using a digital caliper at T1 and T2. Statistical validation included one-way ANOVA, t-tests, Mann-Whitney U tests, and correlation analyses. Multivariate linear regression was used to assess associations after adjusting for confounding factors.
Results:
Of the 50 patients, 35 underwent a transcrestal approach and 15 underwent a lateral approach. The results showed significant endosinus bone gain (ESBG) differences between allogeneic and xenogeneic grafts and no grafts (p < .001). Osteotomy sinus floor elevation without grafting yielded 3.24 ± 1.42 of ESBG. When divided into three groups based on initial RBH, RBH 1 had 27 patients, RBH 2 had 12 patients, and RBH 3 had 11 patients. Within the RBH group 1 (RBH under 4), the lateral approach had significantly greater ESBG than the transcrestal approach (p < .001). Multivariate linear regression analysis confirmed statistically significant associations between the studied variables after adjusting for confounding factors.
Conclusion
When the RBH is < 4 mm, lateral-approach sinus augmentation and bone grafting should be performed to attain significant ESBG. The RBH, bone graft materials, and sinus elevation techniques vary considerably in ESBG.
7.Evaluation of Factors Influencing Maxillary Sinus Floor Augmentation for Implant Placement: A Retrospective Study
Jihun CHA ; Jaeyoung RYU ; Seunggon JUNG ; Hong-Ju PARK ; Hee-Kyun OH ; Min-Suk KOOK
Journal of implantology and applied sciences 2024;28(2):77-87
Purpose:
This retrospective study compared the maxillary sinus floor augmentation techniques (lateral and transcrestal approaches) to assess the impact of bone grafting, graft materials, and initial residual bone height (RBH). Materials and Methods: Fifty patients who underwent maxillary sinus floor augmentation for posterior maxillary implant placement were included. Panoramic radiographs were obtained before surgery (T0), immediately after surgery (T1), and 6-10 months post-surgery (T2). Length measurements on panoramic radiographs were performed using a digital caliper at T1 and T2. Statistical validation included one-way ANOVA, t-tests, Mann-Whitney U tests, and correlation analyses. Multivariate linear regression was used to assess associations after adjusting for confounding factors.
Results:
Of the 50 patients, 35 underwent a transcrestal approach and 15 underwent a lateral approach. The results showed significant endosinus bone gain (ESBG) differences between allogeneic and xenogeneic grafts and no grafts (p < .001). Osteotomy sinus floor elevation without grafting yielded 3.24 ± 1.42 of ESBG. When divided into three groups based on initial RBH, RBH 1 had 27 patients, RBH 2 had 12 patients, and RBH 3 had 11 patients. Within the RBH group 1 (RBH under 4), the lateral approach had significantly greater ESBG than the transcrestal approach (p < .001). Multivariate linear regression analysis confirmed statistically significant associations between the studied variables after adjusting for confounding factors.
Conclusion
When the RBH is < 4 mm, lateral-approach sinus augmentation and bone grafting should be performed to attain significant ESBG. The RBH, bone graft materials, and sinus elevation techniques vary considerably in ESBG.
8.The Accuracy of Implant Placement According to the Height of the Surgical Guide Hole
Kyu Won PARK ; Jihun CHA ; Seunggon JUNG ; Min‑Suk KOOK ; Hong-Ju PARK ; Hee-Kyun OH ; Jaeyoung RYU
Journal of Korean Dental Science 2024;17(4):201-209
Purpose:
This study investigated the impact of the guide hole height on the accuracy of implant placement using CAD/ CAM-fabricated surgical guides in resin models. The hypothesis is that decreasing the height of the guide hole reduces placement accuracy.
Materials and Methods:
Ten identical partially edentulous maxillary models were each fitted with surgical guides featuring guide hole heights of 1 mm, 3 mm, and/or 5 mm. Using a surgical guide and drill kit, implants were placed in six predetermined sites per model. Placement accuracy was evaluated by comparing the actual implant positions with the planned positions using digital scanning and computer software analysis. Statistical analyses were performed using ANOVA and Kruskal-Wallis tests to determine the significance of deviations at both the coronal and apical positions.
Results:
The average deviations were 0.75±0.33 mm at the coronal position and 1.10±0.51 mm at the apical position. Placement accuracy didnot differ with different guide hole heights. Additionally, errors were consistent regardless of the guide hole height and were not influenced by the type of support or the implant placement site.
Conclusion
In this rotro study, varying the height of the guide hole did not significantly affect the accuracy of implant placement. The results suggest that guide hole height within the tested range does not have a substantial impact on placement errors. Our findings indicate that factors other than the guide holeheight may play a more critical role in implant placement accuracy.
9.Evaluation of Factors Influencing Maxillary Sinus Floor Augmentation for Implant Placement: A Retrospective Study
Jihun CHA ; Jaeyoung RYU ; Seunggon JUNG ; Hong-Ju PARK ; Hee-Kyun OH ; Min-Suk KOOK
Journal of implantology and applied sciences 2024;28(2):77-87
Purpose:
This retrospective study compared the maxillary sinus floor augmentation techniques (lateral and transcrestal approaches) to assess the impact of bone grafting, graft materials, and initial residual bone height (RBH). Materials and Methods: Fifty patients who underwent maxillary sinus floor augmentation for posterior maxillary implant placement were included. Panoramic radiographs were obtained before surgery (T0), immediately after surgery (T1), and 6-10 months post-surgery (T2). Length measurements on panoramic radiographs were performed using a digital caliper at T1 and T2. Statistical validation included one-way ANOVA, t-tests, Mann-Whitney U tests, and correlation analyses. Multivariate linear regression was used to assess associations after adjusting for confounding factors.
Results:
Of the 50 patients, 35 underwent a transcrestal approach and 15 underwent a lateral approach. The results showed significant endosinus bone gain (ESBG) differences between allogeneic and xenogeneic grafts and no grafts (p < .001). Osteotomy sinus floor elevation without grafting yielded 3.24 ± 1.42 of ESBG. When divided into three groups based on initial RBH, RBH 1 had 27 patients, RBH 2 had 12 patients, and RBH 3 had 11 patients. Within the RBH group 1 (RBH under 4), the lateral approach had significantly greater ESBG than the transcrestal approach (p < .001). Multivariate linear regression analysis confirmed statistically significant associations between the studied variables after adjusting for confounding factors.
Conclusion
When the RBH is < 4 mm, lateral-approach sinus augmentation and bone grafting should be performed to attain significant ESBG. The RBH, bone graft materials, and sinus elevation techniques vary considerably in ESBG.
10.The Accuracy of Implant Placement According to the Height of the Surgical Guide Hole
Kyu Won PARK ; Jihun CHA ; Seunggon JUNG ; Min‑Suk KOOK ; Hong-Ju PARK ; Hee-Kyun OH ; Jaeyoung RYU
Journal of Korean Dental Science 2024;17(4):201-209
Purpose:
This study investigated the impact of the guide hole height on the accuracy of implant placement using CAD/ CAM-fabricated surgical guides in resin models. The hypothesis is that decreasing the height of the guide hole reduces placement accuracy.
Materials and Methods:
Ten identical partially edentulous maxillary models were each fitted with surgical guides featuring guide hole heights of 1 mm, 3 mm, and/or 5 mm. Using a surgical guide and drill kit, implants were placed in six predetermined sites per model. Placement accuracy was evaluated by comparing the actual implant positions with the planned positions using digital scanning and computer software analysis. Statistical analyses were performed using ANOVA and Kruskal-Wallis tests to determine the significance of deviations at both the coronal and apical positions.
Results:
The average deviations were 0.75±0.33 mm at the coronal position and 1.10±0.51 mm at the apical position. Placement accuracy didnot differ with different guide hole heights. Additionally, errors were consistent regardless of the guide hole height and were not influenced by the type of support or the implant placement site.
Conclusion
In this rotro study, varying the height of the guide hole did not significantly affect the accuracy of implant placement. The results suggest that guide hole height within the tested range does not have a substantial impact on placement errors. Our findings indicate that factors other than the guide holeheight may play a more critical role in implant placement accuracy.

Result Analysis
Print
Save
E-mail