1.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
2.Influence of template design on the accuracy of static computer-assisted implant surgery
Jinmook CHUNG ; Junghyun PARK ; Hyeonseong SON ; Seoung-Jin HONG ; Ahran PAE
The Journal of Advanced Prosthodontics 2025;17(1):22-35
PURPOSE:
This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs.
MATERIALS AND METHODS:
Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1–4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5–6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models.
RESULTS:
While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation.
CONCLUSION
Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.
3.Key factors for successful eruption of the mandibular third molar after extraction of the mandibular second molar
Jung Jin PARK ; Yoonjeong NOH ; Yoon Jeong CHOI ; Jae Hyun PARK ; Ji Hyun LEE ; Chooryung Judi CHUNG ; Kyung-Ho KIM
The Korean Journal of Orthodontics 2025;55(2):154-163
Objective:
Extraction of the mandibular second molar (L7) and substitution by the mandibular third molar (L8) is an effective treatment option. This study aimed to evaluate spontaneously erupted L8 occlusion after L7 extraction, and identify the influencing factors.
Methods:
This study assessed 46 L8 from 28 patients using dental study models, panoramic radiographs, and lateral cephalograms obtained during L7 extraction (T1) and completion of L8 eruption (T2). At T2, samples were categorized as acceptable (A-group) or unacceptable (U-group) based on the American Board of Orthodontics index.L8 angulation and position, retromolar space, distance between the Xi point and mandibular first molar (L6), and Nolla stage were compared between the groups to identify the predictive factors for successful eruption.
Results:
At T2, 58.7% of L8 exhibited acceptable occlusion. Age at T1 was significantly higher in the U-group than that in the A-group. Angles ∠6-MnP and ∠8-MnP differed significantly between the groups at T2. Xi-L6 distance was considerably longer in the A-group than that in the U-group at T1 and T2. Younger age at extraction and Xi-L6 distance at T1 affected the acceptable occlusion.
Conclusions
Younger age at L7 extraction and adequate eruption space (Xi-L6 distance) appear to be the key factors for achieving acceptable L8 occlusion.
4.Vitamin D Attenuates Non-Alcoholic Fatty Liver Disease in High-Fat Diet-Induced Obesity Murine Model
Sook In CHUNG ; Lin LIANG ; Heejae HAN ; Kyung Hee PARK ; Jae-Hyun LEE ; Jung-Won PARK
Yonsei Medical Journal 2025;66(2):75-86
Purpose:
Obesity and metabolic syndrome are acknowledged as key factors contributing to the development of non-alcoholic fatty liver disease (NAFLD). Vitamin D (VitD) is a multifaceted secosteroid hormone known for its anti-fibrotic and anti-inflammatory properties, with its deficiency often linked to obesity. Our study aimed to investigate whether VitD supplementation could mitigate the liver pathology associated with NAFLD.
Materials and Methods:
The NAFLD model was developed by subjecting male C57BL/6 mice to a high-fat diet (HFD) for 14 weeks.These mice were supplemented with VitD through intraperitoneal injection at a dosage of 7 μg/kg, administered three times per week for 7 weeks.
Results:
HFD resulted in VitD deficiency, insulin resistance, and increased liver weight. It elevated serum levels of liver aminotransferases and triglyceride, ultimately leading to steatohepatitis with fibrosis. This model exhibited increased levels of transforming growth factor (TGF)-β1, pro-inflammatory cytokines, HNF4α transcription factors, reactive oxygen species (ROS), renin-angiotensin system activity, and epithelial-mesenchymal transitions (EMT) within the liver. Supplementation with VitD resulted in the recovery of liver weight, improvement in histologic features associated with steatohepatitis, and reduction in alanine aminotransferases and triglyceride levels induced by the HFD. Additionally, it mitigated the HFD-induced over-expressions of TGF-β1 and fibrosis-related genes, along with pro-inflammatory cytokines and ROS. Notably, no adverse effect was found due to VitD supplementation in this model.
Conclusion
VitD ameliorates steatohepatitis within obesity-induced NAFLD through its multifaceted pathways. VitD supplementation emerges as a potentially safe, cost-effective, and direct treatment approach for NAFLD patients dealing with obesity or metabolic dysfunction.
5.Comparison of tissue-based and plasma-based testing for EGFR mutation in non–small cell lung cancer patients
Yoon Kyung KANG ; Dong Hoon SHIN ; Joon Young PARK ; Chung Su HWANG ; Hyun Jung LEE ; Jung Hee LEE ; Jee Yeon KIM ; JooYoung NA
Journal of Pathology and Translational Medicine 2025;59(1):60-67
Background:
Epidermal growth factor receptor (EGFR) gene mutation testing is crucial for the administration of tyrosine kinase inhibitors to treat non–small cell lung cancer. In addition to traditional tissue-based tests, liquid biopsies using plasma are increasingly utilized, particularly for detecting T790M mutations. This study compared tissue- and plasma-based EGFR testing methods.
Methods:
A total of 248 patients were tested for EGFR mutations using tissue and plasma samples from 2018 to 2023 at Pusan National University Yangsan Hospital. Tissue tests were performed using PANAmutyper, and plasma tests were performed using the Cobas EGFR Mutation Test v2.
Results:
All 248 patients underwent tissue-based EGFR testing, and 245 (98.8%) showed positive results. Of the 408 plasma tests, 237 (58.1%) were positive. For the T790M mutation, tissue biopsies were performed 87 times in 69 patients, and 30 positive cases (38.6%) were detected. Plasma testing for the T790M mutation was conducted 333 times in 207 patients, yielding 62 positive results (18.6%). Of these, 57 (27.5%) were confirmed to have the mutation via plasma testing. Combined tissue and plasma tests for the T790M mutation were positive in nine patients (13.4%), while 17 (25.4%) were positive in tissue only and 12 (17.9%) in plasma only. This mutation was not detected in 28 patients (43.3%).
Conclusions
Although the tissue- and plasma-based tests showed a sensitivity of 37.3% and 32.8%, respectively, combined testing increased the detection rate to 56.7%. Thus, neither test demonstrated superiority, rather, they were complementary.
6.Study Protocol of Expanded Multicenter Prospective Cohort Study of Active Surveillance on Papillary Thyroid Microcarcinoma (MAeSTro-EXP)
Jae Hoon MOON ; Eun Kyung LEE ; Wonjae CHA ; Young Jun CHAI ; Sun Wook CHO ; June Young CHOI ; Sung Yong CHOI ; A Jung CHU ; Eun-Jae CHUNG ; Yul HWANGBO ; Woo-Jin JEONG ; Yuh-Seog JUNG ; Kyungsik KIM ; Min Joo KIM ; Su-jin KIM ; Woochul KIM ; Yoo Hyung KIM ; Chang Yoon LEE ; Ji Ye LEE ; Kyu Eun LEE ; Young Ki LEE ; Hunjong LIM ; Do Joon PARK ; Sue K. PARK ; Chang Hwan RYU ; Junsun RYU ; Jungirl SEOK ; Young Shin SONG ; Ka Hee YI ; Hyeong Won YU ; Eleanor WHITE ; Katerina MASTROCOSTAS ; Roderick J. CLIFTON-BLIGH ; Anthony GLOVER ; Matti L. GILD ; Ji-hoon KIM ; Young Joo PARK
Endocrinology and Metabolism 2025;40(2):236-246
Background:
Active surveillance (AS) has emerged as a viable management strategy for low-risk papillary thyroid microcarcinoma (PTMC), following pioneering trials at Kuma Hospital and the Cancer Institute Hospital in Japan. Numerous prospective cohort studies have since validated AS as a management option for low-risk PTMC, leading to its inclusion in thyroid cancer guidelines across various countries. From 2016 to 2020, the Multicenter Prospective Cohort Study of Active Surveillance on Papillary Thyroid Microcarcinoma (MAeSTro) enrolled 1,177 patients, providing comprehensive data on PTMC progression, sonographic predictors of progression, quality of life, surgical outcomes, and cost-effectiveness when comparing AS to immediate surgery. The second phase of MAeSTro (MAeSTro-EXP) expands AS to low-risk papillary thyroid carcinoma (PTC) tumors larger than 1 cm, driven by the hypothesis that overall risk assessment outweighs absolute tumor size in surgical decision-making.
Methods:
This protocol aims to address whether limiting AS to tumors smaller than 1 cm may result in unnecessary surgeries for low-risk PTCs detected during their rapid initial growth phase. By expanding the AS criteria to include tumors up to 1.5 cm, while simultaneously refining and standardizing the criteria for risk assessment and disease progression, we aim to minimize overtreatment and maintain rigorous monitoring to improve patient outcomes.
Conclusion
This study will contribute to optimizing AS guidelines and enhance our understanding of the natural course and appropriate management of low-risk PTCs. Additionally, MAeSTro-EXP involves a multinational collaboration between South Korea and Australia. This cross-country study aims to identify cultural and racial differences in the management of low-risk PTC, thereby enriching the global understanding of AS practices and their applicability across diverse populations.
7.Safety and efficacy of HK-660S in patients with primary sclerosing cholangitis: A randomized double-blind phase 2a trial
Woo Hyun PAIK ; Joo Kyung PARK ; Moon Jae CHUNG ; Gunn HUH ; Ce Hwan PARK ; Sang Hyub LEE ; Heon Se JEONG ; Hee Jin KIM ; Do Hyun PARK
Clinical and Molecular Hepatology 2025;31(1):119-130
Background/Aims:
A clinical unmet need persists for medications capable of modulating the progression of primary sclerosing cholangitis (PSC). This study aimed to assess the clinical feasibility of HK-660S (beta-lapachone) in PSC.
Methods:
In this multicenter, randomized, double-blind, placebo-controlled, parallel-group phase 2 trial, participants were assigned in a 2:1 ratio to receive either 100 mg of HK-660S or a placebo twice daily for 12 weeks. The primary outcomes were the reduction in serum alkaline phosphatase (ALP) levels and the percentage of participants showing improvements in PSC severity, as determined by magnetic resonance cholangiopancreatography with the Anali score. Secondary endpoints included changes in liver stiffness and adverse events.
Results:
The analysis included 21 patients, 15 receiving HK-660S, and six receiving a placebo. Improvements in the Anali score were observed in 13.3% of the HK-660S group, with no improvements in the placebo group. HK-660S treatment resulted in a 15.2% reduction in mean ALP levels, compared to a 6.6% reduction in the placebo group. A stratified ad-hoc analysis based on baseline ALP levels showed a statistically significant response in the HK-660S group among those with ALP levels greater than twice the upper limit of normal, with a 50% responder rate (p=0.05). Additionally, 26.7% of the HK-660S group showed improvements in the enhanced liver fibrosis score, with no improvements in the placebo group. HK-660S was generally well tolerated.
Conclusions
HK-660S is well tolerated among patients with PSC and may improve bile duct strictures, decrease serum ALP levels, and reduce liver fibrosis (cris.nih.go.kr, Number KCT0006590).
8.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
9.Influence of template design on the accuracy of static computer-assisted implant surgery
Jinmook CHUNG ; Junghyun PARK ; Hyeonseong SON ; Seoung-Jin HONG ; Ahran PAE
The Journal of Advanced Prosthodontics 2025;17(1):22-35
PURPOSE:
This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs.
MATERIALS AND METHODS:
Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1–4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5–6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models.
RESULTS:
While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation.
CONCLUSION
Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.
10.Key factors for successful eruption of the mandibular third molar after extraction of the mandibular second molar
Jung Jin PARK ; Yoonjeong NOH ; Yoon Jeong CHOI ; Jae Hyun PARK ; Ji Hyun LEE ; Chooryung Judi CHUNG ; Kyung-Ho KIM
The Korean Journal of Orthodontics 2025;55(2):154-163
Objective:
Extraction of the mandibular second molar (L7) and substitution by the mandibular third molar (L8) is an effective treatment option. This study aimed to evaluate spontaneously erupted L8 occlusion after L7 extraction, and identify the influencing factors.
Methods:
This study assessed 46 L8 from 28 patients using dental study models, panoramic radiographs, and lateral cephalograms obtained during L7 extraction (T1) and completion of L8 eruption (T2). At T2, samples were categorized as acceptable (A-group) or unacceptable (U-group) based on the American Board of Orthodontics index.L8 angulation and position, retromolar space, distance between the Xi point and mandibular first molar (L6), and Nolla stage were compared between the groups to identify the predictive factors for successful eruption.
Results:
At T2, 58.7% of L8 exhibited acceptable occlusion. Age at T1 was significantly higher in the U-group than that in the A-group. Angles ∠6-MnP and ∠8-MnP differed significantly between the groups at T2. Xi-L6 distance was considerably longer in the A-group than that in the U-group at T1 and T2. Younger age at extraction and Xi-L6 distance at T1 affected the acceptable occlusion.
Conclusions
Younger age at L7 extraction and adequate eruption space (Xi-L6 distance) appear to be the key factors for achieving acceptable L8 occlusion.

Result Analysis
Print
Save
E-mail