1.Newly designed flared-end covered versus uncovered self-expandable metallic stents for palliation of malignant colorectal obstruction: a randomized, prospective study
Soo Jung PARK ; Yehyun PARK ; Hyun Jung LEE ; Jae Jun PARK ; Jae Hee CHEON ; Won Ho KIM ; Tae Il KIM
Intestinal Research 2025;23(2):202-212
Background/Aims:
Self-expandable metallic stents (SEMSs) are widely used as palliative or bridge to surgery treatments in patients with malignant colorectal obstruction (MCO). Stent occlusion is more common with uncovered stents, but stent migration is more common with covered stents. Our purpose was to compare the efficacy and safety of a newly designed covered SEMS with an uncovered proximal flared end (CSEMS-UPF) with that of the conventional uncovered SEMS (UCSEMS) in the treatment of MCO.
Methods:
This prospective randomized trial was conducted at a tertiary-care academic hospital. We enrolled 87 patients with stage 4 cancer and MCO: colorectal cancer in 60 patients and extracolonic cancer in 27 patients. Insertion of UCSEMS was randomly assigned to 43 patients, and 44 patients received the CSEMS-UPF. The primary outcome was the duration of stent patency after successful placement. The secondary outcomes were the number of patients with technical and clinical success and early and late complications from the stent insertion.
Results:
The median patency of the stent did not differ between the UCSEMS and CSEMS-UPF groups (484 [231–737] days vs. 216 [66–366] days, P= 0.242). The technical and clinical success rates did not differ significantly between the groups, either (100.0% vs. 93.2%, respectively, P= 0.241; 100.0% vs. 92.7%, respectively, P= 0.112), nor did the early (n = 2 [4.7%] vs. n = 4 [9.8%], P> 0.999) or late (n = 12 [27.9%] vs. n = 15 [36.6%], P> 0.999) stent complication rates differ between the groups.
Conclusions
The UCSEMS and newly developed CSEMS-UPF are similarly effective treatments for MCO, with no differences in the stent migration or occlusion rates (Clinical trial registration number: NCT02640781).
2.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.
3.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.
4.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.
5.Newly designed flared-end covered versus uncovered self-expandable metallic stents for palliation of malignant colorectal obstruction: a randomized, prospective study
Soo Jung PARK ; Yehyun PARK ; Hyun Jung LEE ; Jae Jun PARK ; Jae Hee CHEON ; Won Ho KIM ; Tae Il KIM
Intestinal Research 2025;23(2):202-212
Background/Aims:
Self-expandable metallic stents (SEMSs) are widely used as palliative or bridge to surgery treatments in patients with malignant colorectal obstruction (MCO). Stent occlusion is more common with uncovered stents, but stent migration is more common with covered stents. Our purpose was to compare the efficacy and safety of a newly designed covered SEMS with an uncovered proximal flared end (CSEMS-UPF) with that of the conventional uncovered SEMS (UCSEMS) in the treatment of MCO.
Methods:
This prospective randomized trial was conducted at a tertiary-care academic hospital. We enrolled 87 patients with stage 4 cancer and MCO: colorectal cancer in 60 patients and extracolonic cancer in 27 patients. Insertion of UCSEMS was randomly assigned to 43 patients, and 44 patients received the CSEMS-UPF. The primary outcome was the duration of stent patency after successful placement. The secondary outcomes were the number of patients with technical and clinical success and early and late complications from the stent insertion.
Results:
The median patency of the stent did not differ between the UCSEMS and CSEMS-UPF groups (484 [231–737] days vs. 216 [66–366] days, P= 0.242). The technical and clinical success rates did not differ significantly between the groups, either (100.0% vs. 93.2%, respectively, P= 0.241; 100.0% vs. 92.7%, respectively, P= 0.112), nor did the early (n = 2 [4.7%] vs. n = 4 [9.8%], P> 0.999) or late (n = 12 [27.9%] vs. n = 15 [36.6%], P> 0.999) stent complication rates differ between the groups.
Conclusions
The UCSEMS and newly developed CSEMS-UPF are similarly effective treatments for MCO, with no differences in the stent migration or occlusion rates (Clinical trial registration number: NCT02640781).
6.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.
7.Newly designed flared-end covered versus uncovered self-expandable metallic stents for palliation of malignant colorectal obstruction: a randomized, prospective study
Soo Jung PARK ; Yehyun PARK ; Hyun Jung LEE ; Jae Jun PARK ; Jae Hee CHEON ; Won Ho KIM ; Tae Il KIM
Intestinal Research 2025;23(2):202-212
Background/Aims:
Self-expandable metallic stents (SEMSs) are widely used as palliative or bridge to surgery treatments in patients with malignant colorectal obstruction (MCO). Stent occlusion is more common with uncovered stents, but stent migration is more common with covered stents. Our purpose was to compare the efficacy and safety of a newly designed covered SEMS with an uncovered proximal flared end (CSEMS-UPF) with that of the conventional uncovered SEMS (UCSEMS) in the treatment of MCO.
Methods:
This prospective randomized trial was conducted at a tertiary-care academic hospital. We enrolled 87 patients with stage 4 cancer and MCO: colorectal cancer in 60 patients and extracolonic cancer in 27 patients. Insertion of UCSEMS was randomly assigned to 43 patients, and 44 patients received the CSEMS-UPF. The primary outcome was the duration of stent patency after successful placement. The secondary outcomes were the number of patients with technical and clinical success and early and late complications from the stent insertion.
Results:
The median patency of the stent did not differ between the UCSEMS and CSEMS-UPF groups (484 [231–737] days vs. 216 [66–366] days, P= 0.242). The technical and clinical success rates did not differ significantly between the groups, either (100.0% vs. 93.2%, respectively, P= 0.241; 100.0% vs. 92.7%, respectively, P= 0.112), nor did the early (n = 2 [4.7%] vs. n = 4 [9.8%], P> 0.999) or late (n = 12 [27.9%] vs. n = 15 [36.6%], P> 0.999) stent complication rates differ between the groups.
Conclusions
The UCSEMS and newly developed CSEMS-UPF are similarly effective treatments for MCO, with no differences in the stent migration or occlusion rates (Clinical trial registration number: NCT02640781).
8.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.
9.Evidence-based management guidelines for noncystic fibrosis bronchiectasis in children and adolescents
Eun LEE ; Kyunghoon KIM ; You Hoon JEON ; In Suk SOL ; Jong Deok KIM ; Taek Ki MIN ; Yoon Ha HWANG ; Hyun-Ju CHO ; Dong In SUH ; Hwan Soo KIM ; Yoon Hee KIM ; Sung-Il WOO ; Yong Ju LEE ; Sungsu JUNG ; Hyeon-Jong YANG ; Gwang Cheon JANG
Clinical and Experimental Pediatrics 2024;67(9):418-426
Noncystic fibrosis bronchiectasis is a chronic respiratory disease that carries high socioeconomic and medical burdens and is caused by diverse respiratory illnesses. To improve clinical outcomes, early recognition, active treatment of exacerbations, and prevention of further exacerbations are essential. However, evidence for the treatment and prevention of acute exacerbation of noncystic fibrosis bronchiectasis, especially in children, is lacking. Therefore, the evidence- and consensus-based guidelines for medical and nonmedical treatment strategies for noncystic fibrosis bronchiectasis in children and adolescents were developed by the Korean Academy of Pediatric Allergy and Respiratory Disease using the methods recommended by the Grading of Recommendations Assessment, Development, and Evaluation working group with evidence published through July 2, 2020. This guideline encompasses evidence-based treatment recommendations as well as expert opinions, addressing crucial aspects of the treatment and management of non-cystic fibrosis bronchiectasis in children. This includes considerations for antibiotics and airway clearance strategies, particularly in areas where evidence may be limited. Large, well-designed, and controlled studies are required to accumulate further evidence of management strategies for noncystic fibrosis bronchiectasis in children and adolescents.
10.Evidence-based management guidelines for noncystic fibrosis bronchiectasis in children and adolescents
Eun LEE ; Kyunghoon KIM ; You Hoon JEON ; In Suk SOL ; Jong Deok KIM ; Taek Ki MIN ; Yoon Ha HWANG ; Hyun-Ju CHO ; Dong In SUH ; Hwan Soo KIM ; Yoon Hee KIM ; Sung-Il WOO ; Yong Ju LEE ; Sungsu JUNG ; Hyeon-Jong YANG ; Gwang Cheon JANG
Clinical and Experimental Pediatrics 2024;67(9):418-426
Noncystic fibrosis bronchiectasis is a chronic respiratory disease that carries high socioeconomic and medical burdens and is caused by diverse respiratory illnesses. To improve clinical outcomes, early recognition, active treatment of exacerbations, and prevention of further exacerbations are essential. However, evidence for the treatment and prevention of acute exacerbation of noncystic fibrosis bronchiectasis, especially in children, is lacking. Therefore, the evidence- and consensus-based guidelines for medical and nonmedical treatment strategies for noncystic fibrosis bronchiectasis in children and adolescents were developed by the Korean Academy of Pediatric Allergy and Respiratory Disease using the methods recommended by the Grading of Recommendations Assessment, Development, and Evaluation working group with evidence published through July 2, 2020. This guideline encompasses evidence-based treatment recommendations as well as expert opinions, addressing crucial aspects of the treatment and management of non-cystic fibrosis bronchiectasis in children. This includes considerations for antibiotics and airway clearance strategies, particularly in areas where evidence may be limited. Large, well-designed, and controlled studies are required to accumulate further evidence of management strategies for noncystic fibrosis bronchiectasis in children and adolescents.

Result Analysis
Print
Save
E-mail