1.Research Status and Trend of Devices for Treating Advanced Heart Failure.
Guo-Hui JIAO ; Shao-Peng XU ; Jing-Jing MIAO ; Yu-Ji WANG ; Kun WU
Acta Academiae Medicinae Sinicae 2023;45(5):840-852
Heart failure (HF),a chronic progressive disease,is a global health problem and the leading cause of deaths in the global population.The pathophysiological abnormalities of HF mainly include abnormal cardiac structure (myocardium and valves),disturbance of electrophysiological activities,and weakened myocardial contractility.In addition to drug therapy and heart transplantation,interventional therapies can be employed for advanced-stage HF,including transcatheter interventions and mechanical circulatory assist devices.This article introduces the devices used for advanced HF that have been marketed or certified as innovative or breakthrough devices around the world and summarizes the research status and prospects the trend in this field.As diversified combinations of HF devices are used for the treatment of advanced HF,considerations regarding individualized HF therapy,risk-benefit evaluation on device design,medical insurance payment,post-market supervision system,and protection of intellectual property rights of high-end technology are needed,which will boost the development of the technology and industry and benefit the patients.
Humans
;
Heart-Assist Devices
;
Heart Failure/therapy*
;
Heart Transplantation
;
Myocardium
;
Chronic Disease
2.Surgical treatment of heart failure in China: towards the era of artificial heart.
Chinese Journal of Surgery 2023;61(3):177-180
The number of patients with heart failure in China is large, and the proportion of patients with end-stage heart failure continues to increase. The clinical effect of guideline-directed medications therapy for end-stage heart failure is poor. Heart transplantation is the most effective treatment for end-stage heart failure. But it is faced with many limitations such as the shortage of donors. In recent years, the research and development of artificial heart in China has made great progress. Three devices have been approved by the National Medical Products Administration for marketing, and another one is undergoing pre-marketing clinical trial. Since 2017, more than 200 cases of ventricular assist device implantation have been carried out in more than 34 hospitals in China. Among them, 70 patients in Fuwai Hospital, Chinese Academy of Medical Sciences had a 2-year survival rate of 90%. The first patient has survived more than 5 years with the device. More efforts should be put into the training of standardized technical team and quality control. Further research should be carried out in the aspects of pulsatile blood flow pump, fully implanted cable-free device, and improved biomaterial with better blood compatibility.
Humans
;
Heart-Assist Devices
;
Heart Failure/surgery*
;
Heart, Artificial
;
Heart Transplantation
;
Pulsatile Flow
3.Long-term outcome of EVAHEART I implantable ventricular assist device for the treatment of end stage heart failure: clinical 3-year follow-up results of 15 cases.
Hai Bo CHEN ; Xian Qiang WANG ; Juan DU ; Jia SHI ; Bing Yang JI ; Li SHI ; Yi Sheng SHI ; Xing Tong ZHOU ; Xiao Han YANG ; Sheng Shou HU
Chinese Journal of Cardiology 2023;51(4):393-399
Objective: To evaluate the long-term efficacy and safety of the implantable ventricular assist system EVAHEART I in clinical use. Methods: Fifteen consecutive patients with end-stage heart failure who received left ventricular assist device therapy in Fuwai Hospital from January 2018 to December 2021 were enrolled in this study, their clinical data were retrospectively analyzed. Cardiac function, liver and kidney function, New York Heart Association (NYHA) classification, 6-minute walk distance and quality of life were evaluated before implantation and at 1, 6, 12, 24 and 36 months after device implantation. Drive cable infection, hemolysis, cerebrovascular events, mechanical failure, abnormally high-power consumption and abnormal pump flow were recorded during follow up. Results: All 15 patients were male, mean average age was (43.0±7.5) years, including 11 cases of dilated cardiomyopathy, 2 cases of ischemic cardiomyopathy, and 2 cases of valvular heart disease. All patients were hemodynamically stable on more than one intravenous vasoactive drugs, and 3 patients were supported by preoperative intra aortic balloon pump (IABP). Compared with before device implantation, left ventricular end-diastolic dimension (LVEDD) was significantly decreased ((80.93±6.69) mm vs. (63.73±6.31) mm, P<0.05), brain natriuretic peptide (BNP), total bilirubin and creatinine were also significantly decreased ((3 544.85±1 723.77) ng/L vs. (770.80±406.39) ng/L; (21.28±10.51) μmol/L vs. (17.39±7.68) μmol/L; (95.82±34.88) μmol/L vs. (77.32±43.81) μmol/L; P<0.05) at 1 week after device implantation. All patients in this group were in NYHA class Ⅳ before implantation, and 9 patients could recover to NYHA class Ⅲ, 3 to class Ⅱ, and 3 to class Ⅰ at 1 month after operation. All patients recovered to class Ⅰ-Ⅱ at 6 months after operation. The 6-minute walk distance, total quality of life and visual analogue scale were significantly increased and improved at 1 month after implantation compared with those before operation (P<0.05). All patients were implanted with EVAHEART I at speeds between 1 700-1 950 rpm, flow rates between 3.2-4.5 L/min, power consumption of 3-9 W. The 1-year, 2-year, and 3-year survival rates were 100%, 87%, and 80%, respectively. Three patients died of multiple organ failure at 412, 610, and 872 d after surgery, respectively. During long-term device carrying, 3 patients developed drive cable infection on 170, 220, and 475 d after surgery, respectively, and were cured by dressing change. One patient underwent heart transplantation at 155 d after surgery due to bacteremia. Three patients developed transient ischemic attack and 1 patient developed hemorrhagic stroke events, all cured without sequelae. Conclusion: EVAHEART I implantable left heart assist system can effectively treat critically ill patients with end-stage heart failure, can be carried for long-term life and significantly improve the survival rate, with clear clinical efficacy.
Humans
;
Male
;
Adult
;
Middle Aged
;
Female
;
Heart Failure/complications*
;
Follow-Up Studies
;
Retrospective Studies
;
Heart-Assist Devices
;
Quality of Life
4.Mechanical circulatory support combined with immunomodulation treatment for patients with fulminant myocarditis: a single-center real-world study.
Ying Chun JIE ; Yi Wei JIANG ; Ke Ji LIANG ; Xiao Ou ZHOU ; Chen Tao ZHANG ; Zhun FU ; Yu Hua ZHAO
Chinese Journal of Cardiology 2022;50(3):277-281
Objective: To investigate the relationship between the mechanical circulatory support (MCS) combined with immunomodulation and the prognosis of patients with fulminant myocarditis. Methods: This is a retrospective study. A total of 88 patients with fulminant myocarditis admitted to Dongguan Kanghua hospital from Aug. 2008 to Dec. 2020 were included. Medical histories, results of laboratory tests, treatment regimens and clinical outcomes of these patients during their hospitalization were collected from the medical record system. According to the treatment methods, the patients were divided into MCS+immunomodulation group (38 cases), MCS group (20 cases) and traditional treatment group (30 cases). Patients in the MCS+immunomodulation group received intra-aortic balloon pump (IABP) or IABP combined with extracorporeal membrane oxygenation (ECMO) and immunoglobulin or glucocorticoid. Patients in the MCS group only received mechanical circulatory support. Patients in the traditional treatment group received neither mechanical circulatory support nor immunomodulatory therapy, and only used vasoactive drugs and cardiotonic drugs. The in-hospital mortality and length of stay were compared among the three groups. Results: A total of 88 patients with fulminant myocarditis aged (35.0±10.8) years were included, and there were 46 males (52.3%). The mortality of MCS+immunomodulation group (7.9% (3/38) vs. 56.7% (17/30), P=0.001 2) and MCS group (30.0% (6/20) vs. 56.7% (17/30), P=0.002 8) were lower than that of traditional treatment group. Compared with the MCS group, the in-hospital mortality in the MCS+immunomodulation group was lower (P=0.005 4). The most common cause of death was multiple organ dysfunction syndrome (MODS). The constituent ratios of death in MCS+immunomodulation group, MCS group and traditional treatment group were 3/3, 4/6 and 12/17, respectively. The incidence of MODS in the MCS group (20% (4/20)) and the traditional treatment group (40% (12/30)) was significantly higher than that in the MCS+immunomodulation group (7.9% (3/38)) (both P<0.01). In discharged patients, the hospitalization time of MCS+immunomodulation group was shorter than that of traditional treatment group ((13.4±5.5)d vs. (18.5±7.4)d, P<0.05) and MCS group ((13.4±5.5)d vs. (16.9±8.5)d, P<0.05). Conclusion: MCS combined with immunomodulatory therapy is associated with lower in-hospital mortality and shorter hospital stay in patients with fulminant myocarditis.
Adult
;
Heart-Assist Devices
;
Humans
;
Immunomodulation
;
Male
;
Middle Aged
;
Myocarditis/therapy*
;
Retrospective Studies
;
Treatment Outcome
;
Young Adult
5.Effect of a delay mode of a ventricular assist device on hemodynamics of the cardiovascular system.
Yiliang REN ; Shaojun WANG ; Yu GAO ; Zijian LI ; Yao ZHANG ; Fangqun WANG
Journal of Biomedical Engineering 2022;39(2):329-338
The implantation of biventricular assist device (BiVAD) is more challenging than that of left ventricular assist device for the interaction in the process of multiple input and output. Besides, ventricular assist device (VAD) often runs in constant speed (CS) mode in clinical use and thus BiVAD also faces the problems of low pulsation and imbalance of blood volume between systemic circulation and pulmonary circulation. In this paper, a delay assist mode for a VAD by shortening the support time of VAD was put forward. Then, the effect of the delay mode on cardiac output, pulsation and the function of the aortic valve was observed by numerical method and the rules of hemodynamics were revealed. The research showed that compared with VAD supported in CS mode, the VAD using delay mode in systolic and diastolic period proposed in this paper could meet the demand of cardiac output perfusion and restore the function of the arterial valves. The open ratio of aortic valve (AV) and pulmonary valve (PV) increased with the time set in delay mode, and the blood through the AV/PV helped to balance the left and the right cardiac volume. Besides, delay mode also improved the pulsation index of arterial blood flow, which is conducive to the recovery of the ventricular pulse function of patients.
Cardiovascular System
;
Diastole
;
Heart Failure
;
Heart Rate
;
Heart-Assist Devices
;
Hemodynamics
;
Humans
;
Models, Cardiovascular
6.Study on the synchronization of biventricular beats with the control mode of left ventricular assist device.
Fangqun WANG ; Yao ZHANG ; Wanqian HE ; Si CHEN ; Teng JING ; Zhihao ZHANG
Journal of Biomedical Engineering 2021;38(1):72-79
Right ventricular (RV) failure has become a deadly complication of left ventricular assist device (LVAD) implantation, for which desynchrony in bi-ventricular pulse resulting from a LVAD is among the important factor. This paper investigated how different control modes affect the synchronization of pulse between LV (left ventricular) and RV by numerical method. The numerical results showed that the systolic duration between LV and RV did not significantly differ at baseline (LVAD off and cannula clamped) (48.52%
Heart Failure/therapy*
;
Heart-Assist Devices
;
Humans
;
Systole
;
Ventricular Dysfunction, Right
;
Ventricular Function, Right
7.Study on modeling, simulation, and sensorless feedback control algorithm of the cavopulmonary assist device based on the subpulmonary ventricular exclusion.
Jing PENG ; Zhehuan TAN ; Yong LUAN ; Kairong QIN ; Yu WANG
Journal of Biomedical Engineering 2021;38(3):539-548
The subpulmonary ventricular exclusion (Fontan) could effectively improve the living quality for the children patients with a functional single ventricle in clinical. However, postoperative Fontan circulation failure can easily occur, causing obvious limitations while clinically implementing Fontan. The cavopulmonary assist devices (CPAD) is currently an effective means to solve such limitations. Therefore, in this paper the
Algorithms
;
Child
;
Feedback
;
Heart-Assist Devices
;
Hemodynamics
;
Humans
;
Models, Cardiovascular
8.Clinical application value of transthoracic echocardiography during perioperative period in patients undergoing left ventricular assist device implantation.
Yi Sheng SHI ; Li Li NIU ; Zhen Hui ZHU ; Yu LIANG ; Hao WANG ; Juan DU ; Xian Qiang WANG ; Hai Bo CHEN ; Sheng Shao HU
Chinese Journal of Cardiology 2021;49(6):610-614
Objective: To observe the changes of parameters derived from transthoracic echocardiography (TTE) before and after left ventricular assist device (LVAD) implantation, and to evaluate the clinical value of TTE in the perioperative period of LVAD implantation. Methods: This is a retrospective study. The data of patients who underwent LVAD implantation in Fuwai Hospital from January 2018 to December 2020 were analyzed retrospectively. The TTE parameters, N-terminal pro-B-type natriuretic peptide (NT-proBNP) and total bilirubin (TBil) before and 1 month after LVAD implantation were collected and analyzed. Results: A total of 12 male patients undergoing LVAD implantation were included in this study. The mean age was (43.3±8.6) years. The left atrial volume index ((41.4±12.8)ml/m2 vs. (74.9±30.7)ml/m2, P<0.001), left ventricular end-diastolic volume index ((152.1±35.3)ml/m2 vs. (205.5±35.7)ml/m2, P<0.001), left ventricular end-systolic volume index ((112.5±27.9)ml/m2 vs. (155.1±29.1)ml/m2, P<0.001), right atrial diameter index ((23.7±3.5)mm/m2 vs. (27.2±5.8)mm/m2, P=0.023), right ventricular internal diameter at end-diastole ((24.6±2.7)mm vs. (30.0±4.8)mm, P<0.001), tricuspid annular plane systolic excursion ((11.5±2.9)mm vs. (14.6±2.8)mm, P=0.007), systolic pulmonary arterial pressure ((29.2±4.8) mmHg vs. (55.1±19.3) mmHg, P<0.001, 1 mmHg=0.133 kPa) were significantly reduced at 1 month post LVAD implantation as compared to before LVAD implantation. The aortic sinus diameter ((33.8±4.7)mm vs. (31.6±5.1)mm, P=0.007), left ventricular ejection fraction ((26.3±3.0)% vs. (23.8±4.4)%, P=0.016), right ventricular fractional area change ((31.0±8.6)% vs. (23.8±5.5)%, P=0.004) at 1 month post LVAD implantation were significantly higher than before LVAD implantation. The degree of mitral and tricuspid regurgitation decreased, and the inspiratory collapse rate of inferior vena cava increased (all P<0.05). NT-proBNP ((1 418.4±812.6)ng/L vs. (5 097.5±3 940.4)ng/L, P=0.004) and TBil ((12.4±5.4)μmol/L vs. (27.5±14.0)μmol/L, P=0.001) decreased significantly at 1 month post LVAD implantation. Conclusions: TTE results show that LVAD could effectively relieve left ventricular load and improve right ventricular function. TTE can monitor the cardiac structural and functional changes during the perioperative period of LVAD implantation, and provide the imaging evidence for clinical evaluation of the therapeutic effect of LVAD.
Adult
;
Echocardiography
;
Heart Failure/surgery*
;
Heart-Assist Devices
;
Humans
;
Male
;
Middle Aged
;
Perioperative Period
;
Retrospective Studies
;
Stroke Volume
;
Ventricular Function, Left
9.Numerical simulation and performance analysis of mixed flow blood pump.
Jiping LUO ; Diangui HUANG ; Bin XU
Journal of Biomedical Engineering 2020;37(2):296-303
The high rotational speed of the axial flow blood pump and flow separation of the centrifugal blood pump are the main causes for blood damage in blood pump. The mixed flow blood pump can effectively alleviate the high rotational speed and the flow separation. Based on this, the purpose of this study is to explore the performance of the mixed blood pump with a closed impeller. A mixed flow blood pump with closed impeller was studied by numerical simulation in this paper. The flow field characteristics and the pressure distribution of this type of blood pump were analyzed. The hydraulic performance of the blood pump and the possible damages to red blood cells were also discussed. At last, pump performance was compared with the mixed flow blood pump with semi-open impeller. The results show that the mixed flow blood pump with close impeller studied in this paper can operate safely and efficiently with a good performance. The pump can reach the pressure head of 100 mmHg at 5 L/min mass flow rate. Flow in the blood pump is uniform and no obvious separation or vortex occurs. Pressure distribution in and on the impeller is uniform and reasonable, which can effectively avoid the thrombosis of blood. The average mean value of hemolysis index is 4.99 × 10 . The pump has a good biocompatibility. Compared with the mixed flow blood pump with semi-open impeller, the mixed flow blood pump with closed impeller has higher head and efficiency, a smaller mean value of hemolysis index prediction, a better hydraulic performance and the ability to avoid blood damage. The results of this study may provide a basis for the performance evaluation of the closed impeller mixed flow blood pump.
Computer Simulation
;
Equipment Design
;
Heart-Assist Devices
;
Hemolysis
;
Humans
;
Thrombosis
;
prevention & control
10.Application of hemodynamic optimization in the design of artificial heart.
Minrui FU ; Bin GAO ; Yu CHANG ; Youjun LIU
Journal of Biomedical Engineering 2020;37(6):1000-1011
Heart failure is one kind of cardiovascular disease with high risk and high incidence. As an effective treatment of heart failure, artificial heart is gradually used in clinical treatment. Blood compatibility is an important parameter or index of artificial heart, and how to evaluate it through hemodynamic design and
Heart Failure
;
Heart, Artificial
;
Heart-Assist Devices
;
Hemodynamics
;
Hemolysis
;
Humans

Result Analysis