3.Long-term outcome of transcatheter repair of paravalvular leak post surgical mitral valve replacement.
Chao Fan XING ; Xin PAN ; Cheng WANG ; Lan MA ; Xiao Lei WANG ; Yan Jie LI ; Ben HE
Chinese Journal of Cardiology 2023;51(7):742-749
Objective: To explore the long-term clinical efficacy of transcatheter repair of mitral paravalvular leak (PVL) post surgical mitral valve replacement. Methods: This study is a retrospective study. Patients who completed transcatheter repair of paravalvular leak after surgical mitral valve replacement at Shanghai Chest Hospital, Shanghai Jiaotong University School of Medicine from March 2010 to December 2018 were included. Technical success was defined as the occluder being stably implanted in the paravalvular leak site without affecting the function of the mitral valve and surrounding tissues; and there were no intervention-related complications, such as new hemolysis or aggravated hemolysis, and echocardiography confirmed mitral paravalvular regurgitation reduced by more than 1 grade. Patients were followed up at 30 days, 1, and 3 years after the intervention. The main endpoints were all-cause death and re-surgery due to interventional failure or serious complications. The occurrence of occluder-mediated hemolysis and chronic renal insufficiency was recorded, and patients were monitored with echocardiography during follow up. Results: A total of 75 patients were included, aged (54.3±22.9) years old, and 38 patients were males. All patients had decreased cardiac function and/or hemolysis before intervention. Procedural success was achieved in 54 patients (72.0%). Incidence of device-mediated hemolysis was 18.7% (14/75). During the follow-up period, all-cause death occurred in 7 patients (9.3%), and 3 were cardiac deaths.The 3-year event-free survival rate was 81.3% (61/75). The need for cardiac surgery was 9.3% (7/75): 3 cases due to severe device-mediated hemolysis, 2 cases due to prosthetic valve failure and 2 cases due to moderate to severe residual regurgitation. The echocardiography follow-up results showed that the position of the occluder was stable, there was no impact on the artificial valve function and surrounding structures, and the residual regurgitation was stable without progressive increase in event-free patients. Compared with pre-intervention, the left ventricular end systolic diameter ((33.9±7.4)mm vs. (38.3±8.9) mm, P=0.036), end diastolic diameter ((53.7±8.3) mm vs. (58.4±9.1) mm, P=0.045) and left atrial diameter (59.3 (44.5, 90.7) mm vs. 64.3 (44.8, 96.6) mm, P=0.049) were significantly reduced, pulmonary artery systolic pressure was also significantly decreased ((36.5±15.8) mmHg vs. (46.3±14.9) mmHg, P=0.022, 1 mmHg=0.133 kPa). There was no significant difference between 3 years and 1 year after transcatheter repair of mitral paravalvular leak post surgical mitral valve replacement (all P>0.05). Conclusion: Transcatheter repair of mitral paravalvular leak post surgical mitral valve replacement is an effective treatment option in selective patients.
Male
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Female
;
Mitral Valve/surgery*
;
Heart Valve Prosthesis Implantation
;
Heart Valve Prosthesis
;
Retrospective Studies
;
Hemolysis
;
China
;
Mitral Valve Insufficiency/surgery*
;
Treatment Outcome
;
Cardiac Catheterization
;
Prosthesis Failure
4.Preliminary experience of transcatheter pulmonary valve replacement using domestic balloon-expandable valve.
Zhen Gang ZHAO ; Rui Tao LI ; Xin WEI ; Yong PENG ; Jia Fu WEI ; Sen HE ; Qiao LI ; Xiao LI ; Yi Jian LI ; Xiang LI ; Xuan ZHOU ; Ming Xia ZHENG ; Guo CHEN ; Qi AN ; Mao CHEN ; Yuan FENG
Chinese Journal of Cardiology 2023;51(8):825-831
Objectives: To evaluate the feasibility and preliminary clinical results of transcatheter pulmonary valve replacement (TPVR) with the domestically-produced balloon-expandable Prizvalve system. Methods: This is a prospective single-center observational study. Patients with postoperative right ventricular outflow tract (RVOT) dysfunction, who were admitted to West China Hospital of Sichuan University from September 2021 to March 2023 and deemed anatomically suitable for TPVR with balloon-expandable valve, were included. Clinical, imaging, procedural and follow-up data were analyzed. The immediate procedural results were evaluated by clinical implant success rate, which is defined as successful valve implantation with echocardiography-assessed pulmonary regurgitation
Male
;
Humans
;
Pulmonary Valve/surgery*
;
Heart Valve Prosthesis/adverse effects*
;
Heart Valve Prosthesis Implantation
;
Constriction, Pathologic/surgery*
;
Prospective Studies
;
Ventricular Outflow Obstruction/surgery*
;
Treatment Outcome
;
Cardiac Catheterization/methods*
;
Transcatheter Aortic Valve Replacement
5.Comparison on the efficacy of Chinese-made novel-designed mechanical-locked and elastic self-locked transcatheter edge-to-edge repair system in the treatment of patients with functional mitral regurgitation.
Da ZHU ; Shou Zheng WANG ; Zhi Ling LUO ; Jia Hua PAN ; Ke YANG ; Chun Mei XIE ; Yong Yan TANG ; Hong Bo YANG ; Mi Er MA ; Jian Bin GAO ; Xiang Bin PAN
Chinese Journal of Cardiology 2023;51(8):832-837
Objective: To evaluate and compare the short-term efficacy of domestic mechanical-locked (Clip2Edge) and elastic self-locked (ValveClip) transcranial mitral valve edge-to-edge interventional repair (TEER) devices in the treatment of functional mitral regurgitant valves. Methods: In this retrospective non-randomized comparative study, patients underwent TEER procedure in Fuwai Yunnan Cardiovascular Disease Hospital from May 2022 to April 2023 for heart failure combined with moderate to severe or severe functional mitral valve were divided into Clip2Edge and ValveClip groups based on the TEER system used. Baseline, perioperative, and postoperative 30 d follow-up data were collected and compared between the two groups. The primary outcome was the success rate on the 30 d post operation, while secondary outcomes included immediate postoperative technical success rate and the incidence of all-cause mortality on the 30 d post operation, readmission rate of acute heart failure, cerebral infarction, severe bleeding, and other serious adverse events rates. Results: A total of 60 patients were enrolled, 34 patients were in the Clip2Edge group and 26 in the ValveClip group, mean age was (63.8±9.3) years, and 24 patients (40%) were female. There were no significant differences in baseline data of age, cardiac function, comorbidities, mitral regurgitation 4+(19(73%) vs. 29(85%)), the end-diastolic volume of left ventricle ((220.8±91.2) ml vs. (210.8±71.7) ml) between the two groups (all P>0.05). The technical success rate immediately after the procedure was 100%. There were no readmission of acute heart failure, death, cerebral infarction, severe bleeding, and other serious adverse events up to the 30 d follow-up. Device success rate was similar between the ValveClip group (24 cases (100%)) and the Clip2Edge group (27 cases (96%)) (P>0.05). Conclusion: Both types of novel domestic TEER devices are safe and feasible in treating patients with functional mitral regurgitation.
Humans
;
Female
;
Middle Aged
;
Aged
;
Male
;
Mitral Valve Insufficiency/etiology*
;
Retrospective Studies
;
East Asian People
;
Heart Valve Prosthesis Implantation
;
Treatment Outcome
;
China
;
Heart Failure/etiology*
;
Cardiac Catheterization
8.Simultaneous transcatheter aortic valve replacement and mitral balloon dilatation in patients with severe aortic stenosis and mitral stenosis: two case reports.
Hao Jian DONG ; Rui WANG ; Xia WANG ; Jian LIU ; Bu Zha Xi PU ; Jie LI ; Yu Jing MO ; Ming FU ; Guang LI ; Jian Fang LUO
Chinese Journal of Cardiology 2023;51(10):1082-1086
9.Preliminary experience of transcatheter pulmonary valve replacement using domestic balloon-expandable valve.
Zhen Gang ZHAO ; Rui Tao LI ; Xin WEI ; Yong PENG ; Jia Fu WEI ; Sen HE ; Qiao LI ; Xiao LI ; Yi Jian LI ; Xiang LI ; Xuan ZHOU ; Ming Xia ZHENG ; Guo CHEN ; Qi AN ; Mao CHEN ; Yuan FENG
Chinese Journal of Cardiology 2023;51(8):825-831
Objectives: To evaluate the feasibility and preliminary clinical results of transcatheter pulmonary valve replacement (TPVR) with the domestically-produced balloon-expandable Prizvalve system. Methods: This is a prospective single-center observational study. Patients with postoperative right ventricular outflow tract (RVOT) dysfunction, who were admitted to West China Hospital of Sichuan University from September 2021 to March 2023 and deemed anatomically suitable for TPVR with balloon-expandable valve, were included. Clinical, imaging, procedural and follow-up data were analyzed. The immediate procedural results were evaluated by clinical implant success rate, which is defined as successful valve implantation with echocardiography-assessed pulmonary regurgitation
Male
;
Humans
;
Pulmonary Valve/surgery*
;
Heart Valve Prosthesis/adverse effects*
;
Heart Valve Prosthesis Implantation
;
Constriction, Pathologic/surgery*
;
Prospective Studies
;
Ventricular Outflow Obstruction/surgery*
;
Treatment Outcome
;
Cardiac Catheterization/methods*
;
Transcatheter Aortic Valve Replacement
10.Comparison on the efficacy of Chinese-made novel-designed mechanical-locked and elastic self-locked transcatheter edge-to-edge repair system in the treatment of patients with functional mitral regurgitation.
Da ZHU ; Shou Zheng WANG ; Zhi Ling LUO ; Jia Hua PAN ; Ke YANG ; Chun Mei XIE ; Yong Yan TANG ; Hong Bo YANG ; Mi Er MA ; Jian Bin GAO ; Xiang Bin PAN
Chinese Journal of Cardiology 2023;51(8):832-837
Objective: To evaluate and compare the short-term efficacy of domestic mechanical-locked (Clip2Edge) and elastic self-locked (ValveClip) transcranial mitral valve edge-to-edge interventional repair (TEER) devices in the treatment of functional mitral regurgitant valves. Methods: In this retrospective non-randomized comparative study, patients underwent TEER procedure in Fuwai Yunnan Cardiovascular Disease Hospital from May 2022 to April 2023 for heart failure combined with moderate to severe or severe functional mitral valve were divided into Clip2Edge and ValveClip groups based on the TEER system used. Baseline, perioperative, and postoperative 30 d follow-up data were collected and compared between the two groups. The primary outcome was the success rate on the 30 d post operation, while secondary outcomes included immediate postoperative technical success rate and the incidence of all-cause mortality on the 30 d post operation, readmission rate of acute heart failure, cerebral infarction, severe bleeding, and other serious adverse events rates. Results: A total of 60 patients were enrolled, 34 patients were in the Clip2Edge group and 26 in the ValveClip group, mean age was (63.8±9.3) years, and 24 patients (40%) were female. There were no significant differences in baseline data of age, cardiac function, comorbidities, mitral regurgitation 4+(19(73%) vs. 29(85%)), the end-diastolic volume of left ventricle ((220.8±91.2) ml vs. (210.8±71.7) ml) between the two groups (all P>0.05). The technical success rate immediately after the procedure was 100%. There were no readmission of acute heart failure, death, cerebral infarction, severe bleeding, and other serious adverse events up to the 30 d follow-up. Device success rate was similar between the ValveClip group (24 cases (100%)) and the Clip2Edge group (27 cases (96%)) (P>0.05). Conclusion: Both types of novel domestic TEER devices are safe and feasible in treating patients with functional mitral regurgitation.
Humans
;
Female
;
Middle Aged
;
Aged
;
Male
;
Mitral Valve Insufficiency/etiology*
;
Retrospective Studies
;
East Asian People
;
Heart Valve Prosthesis Implantation
;
Treatment Outcome
;
China
;
Heart Failure/etiology*
;
Cardiac Catheterization

Result Analysis
Print
Save
E-mail