1.Biennial Mammography Performance in the Korean National Cancer Screening Program From 2009 to 2020
Dong Jun KIM ; Nan-He YOON ; Jae Kwan JUN ; Mina SUH ; Sunhwa LEE ; Seongju KIM ; Horim A. HWANG ; Seung Eun JUNG ; Hooyeon LEE
Korean Journal of Radiology 2025;26(4):313-323
Objective:
Mammography is essential for reducing breast cancer mortality; however, its performance varies globally. This study aimed to evaluate mammography screening outcomes in Korea over 12 years and investigate regional variations.
Materials and Methods:
We analyzed mammography data from 42 million Korean women, aged 40 years and older, who participated in the Korean National Cancer Screening Program (KNCSP) from 2009 to 2020. Performance metrics—including recall rate (RR), positive predictive value (PPV), sensitivity, specificity, false positive rate (FPR), cancer detection rate (CDR), interval cancer rate (ICR), and dense breast rate (DBR), were computed. Twelve-year trends in these metrics were analyzed using Joinpoint regression. Regional variations were also examined across Korea’s 237 districts, stratified by age groups.
Results:
From 2009 to 2020, 42165405 mammography screenings were conducted through the KNCSP, increasing from 2821132 screenings in 2009 to 3596204 in 2020. The RR decreased from 17.2% in 2009 to 11.2% in 2020 (average annual percent change [AAPC] = -3.7%), while the PPV increased from 0.8% to 2.8%; AAPC = 10.7%), the CDR increased from 1.5 to 3.1 per 1000; AAPC = 7.3%), and the ICR rose from 0.9 to 1.6 per 1000; (AAPC = 5.2%). Regional variations were noted; however, differences in the RR, sensitivity, specificity, and FPR decreased over time.
Conclusion
While mammography performance improved from 2009 to 2020, the PPV and sensitivity remain suboptimal, underscoring the need for continuous monitoring. Regional disparities in performance, although reduced, persist. These findings provide essential baseline data for improving mammography quality and addressing inequities in breast cancer screening.
2.Biennial Mammography Performance in the Korean National Cancer Screening Program From 2009 to 2020
Dong Jun KIM ; Nan-He YOON ; Jae Kwan JUN ; Mina SUH ; Sunhwa LEE ; Seongju KIM ; Horim A. HWANG ; Seung Eun JUNG ; Hooyeon LEE
Korean Journal of Radiology 2025;26(4):313-323
Objective:
Mammography is essential for reducing breast cancer mortality; however, its performance varies globally. This study aimed to evaluate mammography screening outcomes in Korea over 12 years and investigate regional variations.
Materials and Methods:
We analyzed mammography data from 42 million Korean women, aged 40 years and older, who participated in the Korean National Cancer Screening Program (KNCSP) from 2009 to 2020. Performance metrics—including recall rate (RR), positive predictive value (PPV), sensitivity, specificity, false positive rate (FPR), cancer detection rate (CDR), interval cancer rate (ICR), and dense breast rate (DBR), were computed. Twelve-year trends in these metrics were analyzed using Joinpoint regression. Regional variations were also examined across Korea’s 237 districts, stratified by age groups.
Results:
From 2009 to 2020, 42165405 mammography screenings were conducted through the KNCSP, increasing from 2821132 screenings in 2009 to 3596204 in 2020. The RR decreased from 17.2% in 2009 to 11.2% in 2020 (average annual percent change [AAPC] = -3.7%), while the PPV increased from 0.8% to 2.8%; AAPC = 10.7%), the CDR increased from 1.5 to 3.1 per 1000; AAPC = 7.3%), and the ICR rose from 0.9 to 1.6 per 1000; (AAPC = 5.2%). Regional variations were noted; however, differences in the RR, sensitivity, specificity, and FPR decreased over time.
Conclusion
While mammography performance improved from 2009 to 2020, the PPV and sensitivity remain suboptimal, underscoring the need for continuous monitoring. Regional disparities in performance, although reduced, persist. These findings provide essential baseline data for improving mammography quality and addressing inequities in breast cancer screening.
3.Biennial Mammography Performance in the Korean National Cancer Screening Program From 2009 to 2020
Dong Jun KIM ; Nan-He YOON ; Jae Kwan JUN ; Mina SUH ; Sunhwa LEE ; Seongju KIM ; Horim A. HWANG ; Seung Eun JUNG ; Hooyeon LEE
Korean Journal of Radiology 2025;26(4):313-323
Objective:
Mammography is essential for reducing breast cancer mortality; however, its performance varies globally. This study aimed to evaluate mammography screening outcomes in Korea over 12 years and investigate regional variations.
Materials and Methods:
We analyzed mammography data from 42 million Korean women, aged 40 years and older, who participated in the Korean National Cancer Screening Program (KNCSP) from 2009 to 2020. Performance metrics—including recall rate (RR), positive predictive value (PPV), sensitivity, specificity, false positive rate (FPR), cancer detection rate (CDR), interval cancer rate (ICR), and dense breast rate (DBR), were computed. Twelve-year trends in these metrics were analyzed using Joinpoint regression. Regional variations were also examined across Korea’s 237 districts, stratified by age groups.
Results:
From 2009 to 2020, 42165405 mammography screenings were conducted through the KNCSP, increasing from 2821132 screenings in 2009 to 3596204 in 2020. The RR decreased from 17.2% in 2009 to 11.2% in 2020 (average annual percent change [AAPC] = -3.7%), while the PPV increased from 0.8% to 2.8%; AAPC = 10.7%), the CDR increased from 1.5 to 3.1 per 1000; AAPC = 7.3%), and the ICR rose from 0.9 to 1.6 per 1000; (AAPC = 5.2%). Regional variations were noted; however, differences in the RR, sensitivity, specificity, and FPR decreased over time.
Conclusion
While mammography performance improved from 2009 to 2020, the PPV and sensitivity remain suboptimal, underscoring the need for continuous monitoring. Regional disparities in performance, although reduced, persist. These findings provide essential baseline data for improving mammography quality and addressing inequities in breast cancer screening.
4.Biennial Mammography Performance in the Korean National Cancer Screening Program From 2009 to 2020
Dong Jun KIM ; Nan-He YOON ; Jae Kwan JUN ; Mina SUH ; Sunhwa LEE ; Seongju KIM ; Horim A. HWANG ; Seung Eun JUNG ; Hooyeon LEE
Korean Journal of Radiology 2025;26(4):313-323
Objective:
Mammography is essential for reducing breast cancer mortality; however, its performance varies globally. This study aimed to evaluate mammography screening outcomes in Korea over 12 years and investigate regional variations.
Materials and Methods:
We analyzed mammography data from 42 million Korean women, aged 40 years and older, who participated in the Korean National Cancer Screening Program (KNCSP) from 2009 to 2020. Performance metrics—including recall rate (RR), positive predictive value (PPV), sensitivity, specificity, false positive rate (FPR), cancer detection rate (CDR), interval cancer rate (ICR), and dense breast rate (DBR), were computed. Twelve-year trends in these metrics were analyzed using Joinpoint regression. Regional variations were also examined across Korea’s 237 districts, stratified by age groups.
Results:
From 2009 to 2020, 42165405 mammography screenings were conducted through the KNCSP, increasing from 2821132 screenings in 2009 to 3596204 in 2020. The RR decreased from 17.2% in 2009 to 11.2% in 2020 (average annual percent change [AAPC] = -3.7%), while the PPV increased from 0.8% to 2.8%; AAPC = 10.7%), the CDR increased from 1.5 to 3.1 per 1000; AAPC = 7.3%), and the ICR rose from 0.9 to 1.6 per 1000; (AAPC = 5.2%). Regional variations were noted; however, differences in the RR, sensitivity, specificity, and FPR decreased over time.
Conclusion
While mammography performance improved from 2009 to 2020, the PPV and sensitivity remain suboptimal, underscoring the need for continuous monitoring. Regional disparities in performance, although reduced, persist. These findings provide essential baseline data for improving mammography quality and addressing inequities in breast cancer screening.
5.Biennial Mammography Performance in the Korean National Cancer Screening Program From 2009 to 2020
Dong Jun KIM ; Nan-He YOON ; Jae Kwan JUN ; Mina SUH ; Sunhwa LEE ; Seongju KIM ; Horim A. HWANG ; Seung Eun JUNG ; Hooyeon LEE
Korean Journal of Radiology 2025;26(4):313-323
Objective:
Mammography is essential for reducing breast cancer mortality; however, its performance varies globally. This study aimed to evaluate mammography screening outcomes in Korea over 12 years and investigate regional variations.
Materials and Methods:
We analyzed mammography data from 42 million Korean women, aged 40 years and older, who participated in the Korean National Cancer Screening Program (KNCSP) from 2009 to 2020. Performance metrics—including recall rate (RR), positive predictive value (PPV), sensitivity, specificity, false positive rate (FPR), cancer detection rate (CDR), interval cancer rate (ICR), and dense breast rate (DBR), were computed. Twelve-year trends in these metrics were analyzed using Joinpoint regression. Regional variations were also examined across Korea’s 237 districts, stratified by age groups.
Results:
From 2009 to 2020, 42165405 mammography screenings were conducted through the KNCSP, increasing from 2821132 screenings in 2009 to 3596204 in 2020. The RR decreased from 17.2% in 2009 to 11.2% in 2020 (average annual percent change [AAPC] = -3.7%), while the PPV increased from 0.8% to 2.8%; AAPC = 10.7%), the CDR increased from 1.5 to 3.1 per 1000; AAPC = 7.3%), and the ICR rose from 0.9 to 1.6 per 1000; (AAPC = 5.2%). Regional variations were noted; however, differences in the RR, sensitivity, specificity, and FPR decreased over time.
Conclusion
While mammography performance improved from 2009 to 2020, the PPV and sensitivity remain suboptimal, underscoring the need for continuous monitoring. Regional disparities in performance, although reduced, persist. These findings provide essential baseline data for improving mammography quality and addressing inequities in breast cancer screening.
6.Discordance Between Angiographic Assessment and Fractional Flow Reserve or Intravascular Ultrasound in Intermediate Coronary Lesions: A Post-hoc Analysis of the FLAVOUR Trial
Jung-Hee LEE ; Sung Gyun AHN ; Ho Sung JEON ; Jun-Won LEE ; Young Jin YOUN ; Jinlong ZHANG ; Xinyang HU ; Jian’an WANG ; Joo Myung LEE ; Joo-Yong HAHN ; Chang-Wook NAM ; Joon-Hyung DOH ; Bong-Ki LEE ; Weon KIM ; Jinyu HUANG ; Fan JIANG ; Hao ZHOU ; Peng CHEN ; Lijiang TANG ; Wenbing JIANG ; Xiaomin CHEN ; Wenming HE ; Myeong-Ho YOON ; Seung-Jea TAHK ; Ung KIM ; You-Jeong KI ; Eun-Seok SHIN ; Doyeon HWANG ; Jeehoon KANG ; Hyo-Soo KIM ; Bon-Kwon KOO
Korean Circulation Journal 2024;54(8):485-496
Background and Objectives:
Angiographic assessment of coronary stenosis severity using quantitative coronary angiography (QCA) is often inconsistent with that based on fractional flow reserve (FFR) or intravascular ultrasound (IVUS). We investigated the incidence of discrepancies between QCA and FFR or IVUS, and the outcomes of FFR- and IVUS-guided strategies in discordant coronary lesions.
Methods:
This study was a post-hoc analysis of the FLAVOUR study. We used a QCA-derived diameter stenosis (DS) of 60% or greater, the highest tertile, to classify coronary lesions as concordant or discordant with FFR or IVUS criteria for percutaneous coronary intervention (PCI). The patient-oriented composite outcome (POCO) was defined as a composite of death, myocardial infarction, or revascularization at 24 months.
Results:
The discordance rate between QCA and FFR or IVUS was 30.2% (n=551). The QCAFFR discordance rate was numerically lower than the QCA-IVUS discordance rate (28.2% vs. 32.4%, p=0.050). In 200 patients with ≥60% DS, PCI was deferred according to negative FFR (n=141) and negative IVUS (n=59) (15.3% vs. 6.5%, p<0.001). The POCO incidence was comparable between the FFR- and IVUS-guided deferral strategies (5.9% vs. 3.4%, p=0.479).Conversely, 351 patients with DS <60% underwent PCI according to positive FFR (n=118) and positive IVUS (n=233) (12.8% vs. 25.9%, p<0.001). FFR- and IVUS-guided PCI did not differ in the incidence of POCO (9.5% vs. 6.5%, p=0.294).
Conclusions
The proportion of QCA-FFR or IVUS discordance was approximately one third for intermediate coronary lesions. FFR- or IVUS-guided strategies for these lesions were comparable with respect to POCO at 24 months.
7.Discordance Between Angiographic Assessment and Fractional Flow Reserve or Intravascular Ultrasound in Intermediate Coronary Lesions: A Post-hoc Analysis of the FLAVOUR Trial
Jung-Hee LEE ; Sung Gyun AHN ; Ho Sung JEON ; Jun-Won LEE ; Young Jin YOUN ; Jinlong ZHANG ; Xinyang HU ; Jian’an WANG ; Joo Myung LEE ; Joo-Yong HAHN ; Chang-Wook NAM ; Joon-Hyung DOH ; Bong-Ki LEE ; Weon KIM ; Jinyu HUANG ; Fan JIANG ; Hao ZHOU ; Peng CHEN ; Lijiang TANG ; Wenbing JIANG ; Xiaomin CHEN ; Wenming HE ; Myeong-Ho YOON ; Seung-Jea TAHK ; Ung KIM ; You-Jeong KI ; Eun-Seok SHIN ; Doyeon HWANG ; Jeehoon KANG ; Hyo-Soo KIM ; Bon-Kwon KOO
Korean Circulation Journal 2024;54(8):485-496
Background and Objectives:
Angiographic assessment of coronary stenosis severity using quantitative coronary angiography (QCA) is often inconsistent with that based on fractional flow reserve (FFR) or intravascular ultrasound (IVUS). We investigated the incidence of discrepancies between QCA and FFR or IVUS, and the outcomes of FFR- and IVUS-guided strategies in discordant coronary lesions.
Methods:
This study was a post-hoc analysis of the FLAVOUR study. We used a QCA-derived diameter stenosis (DS) of 60% or greater, the highest tertile, to classify coronary lesions as concordant or discordant with FFR or IVUS criteria for percutaneous coronary intervention (PCI). The patient-oriented composite outcome (POCO) was defined as a composite of death, myocardial infarction, or revascularization at 24 months.
Results:
The discordance rate between QCA and FFR or IVUS was 30.2% (n=551). The QCAFFR discordance rate was numerically lower than the QCA-IVUS discordance rate (28.2% vs. 32.4%, p=0.050). In 200 patients with ≥60% DS, PCI was deferred according to negative FFR (n=141) and negative IVUS (n=59) (15.3% vs. 6.5%, p<0.001). The POCO incidence was comparable between the FFR- and IVUS-guided deferral strategies (5.9% vs. 3.4%, p=0.479).Conversely, 351 patients with DS <60% underwent PCI according to positive FFR (n=118) and positive IVUS (n=233) (12.8% vs. 25.9%, p<0.001). FFR- and IVUS-guided PCI did not differ in the incidence of POCO (9.5% vs. 6.5%, p=0.294).
Conclusions
The proportion of QCA-FFR or IVUS discordance was approximately one third for intermediate coronary lesions. FFR- or IVUS-guided strategies for these lesions were comparable with respect to POCO at 24 months.
8.Discordance Between Angiographic Assessment and Fractional Flow Reserve or Intravascular Ultrasound in Intermediate Coronary Lesions: A Post-hoc Analysis of the FLAVOUR Trial
Jung-Hee LEE ; Sung Gyun AHN ; Ho Sung JEON ; Jun-Won LEE ; Young Jin YOUN ; Jinlong ZHANG ; Xinyang HU ; Jian’an WANG ; Joo Myung LEE ; Joo-Yong HAHN ; Chang-Wook NAM ; Joon-Hyung DOH ; Bong-Ki LEE ; Weon KIM ; Jinyu HUANG ; Fan JIANG ; Hao ZHOU ; Peng CHEN ; Lijiang TANG ; Wenbing JIANG ; Xiaomin CHEN ; Wenming HE ; Myeong-Ho YOON ; Seung-Jea TAHK ; Ung KIM ; You-Jeong KI ; Eun-Seok SHIN ; Doyeon HWANG ; Jeehoon KANG ; Hyo-Soo KIM ; Bon-Kwon KOO
Korean Circulation Journal 2024;54(8):485-496
Background and Objectives:
Angiographic assessment of coronary stenosis severity using quantitative coronary angiography (QCA) is often inconsistent with that based on fractional flow reserve (FFR) or intravascular ultrasound (IVUS). We investigated the incidence of discrepancies between QCA and FFR or IVUS, and the outcomes of FFR- and IVUS-guided strategies in discordant coronary lesions.
Methods:
This study was a post-hoc analysis of the FLAVOUR study. We used a QCA-derived diameter stenosis (DS) of 60% or greater, the highest tertile, to classify coronary lesions as concordant or discordant with FFR or IVUS criteria for percutaneous coronary intervention (PCI). The patient-oriented composite outcome (POCO) was defined as a composite of death, myocardial infarction, or revascularization at 24 months.
Results:
The discordance rate between QCA and FFR or IVUS was 30.2% (n=551). The QCAFFR discordance rate was numerically lower than the QCA-IVUS discordance rate (28.2% vs. 32.4%, p=0.050). In 200 patients with ≥60% DS, PCI was deferred according to negative FFR (n=141) and negative IVUS (n=59) (15.3% vs. 6.5%, p<0.001). The POCO incidence was comparable between the FFR- and IVUS-guided deferral strategies (5.9% vs. 3.4%, p=0.479).Conversely, 351 patients with DS <60% underwent PCI according to positive FFR (n=118) and positive IVUS (n=233) (12.8% vs. 25.9%, p<0.001). FFR- and IVUS-guided PCI did not differ in the incidence of POCO (9.5% vs. 6.5%, p=0.294).
Conclusions
The proportion of QCA-FFR or IVUS discordance was approximately one third for intermediate coronary lesions. FFR- or IVUS-guided strategies for these lesions were comparable with respect to POCO at 24 months.
9.Discordance Between Angiographic Assessment and Fractional Flow Reserve or Intravascular Ultrasound in Intermediate Coronary Lesions: A Post-hoc Analysis of the FLAVOUR Trial
Jung-Hee LEE ; Sung Gyun AHN ; Ho Sung JEON ; Jun-Won LEE ; Young Jin YOUN ; Jinlong ZHANG ; Xinyang HU ; Jian’an WANG ; Joo Myung LEE ; Joo-Yong HAHN ; Chang-Wook NAM ; Joon-Hyung DOH ; Bong-Ki LEE ; Weon KIM ; Jinyu HUANG ; Fan JIANG ; Hao ZHOU ; Peng CHEN ; Lijiang TANG ; Wenbing JIANG ; Xiaomin CHEN ; Wenming HE ; Myeong-Ho YOON ; Seung-Jea TAHK ; Ung KIM ; You-Jeong KI ; Eun-Seok SHIN ; Doyeon HWANG ; Jeehoon KANG ; Hyo-Soo KIM ; Bon-Kwon KOO
Korean Circulation Journal 2024;54(8):485-496
Background and Objectives:
Angiographic assessment of coronary stenosis severity using quantitative coronary angiography (QCA) is often inconsistent with that based on fractional flow reserve (FFR) or intravascular ultrasound (IVUS). We investigated the incidence of discrepancies between QCA and FFR or IVUS, and the outcomes of FFR- and IVUS-guided strategies in discordant coronary lesions.
Methods:
This study was a post-hoc analysis of the FLAVOUR study. We used a QCA-derived diameter stenosis (DS) of 60% or greater, the highest tertile, to classify coronary lesions as concordant or discordant with FFR or IVUS criteria for percutaneous coronary intervention (PCI). The patient-oriented composite outcome (POCO) was defined as a composite of death, myocardial infarction, or revascularization at 24 months.
Results:
The discordance rate between QCA and FFR or IVUS was 30.2% (n=551). The QCAFFR discordance rate was numerically lower than the QCA-IVUS discordance rate (28.2% vs. 32.4%, p=0.050). In 200 patients with ≥60% DS, PCI was deferred according to negative FFR (n=141) and negative IVUS (n=59) (15.3% vs. 6.5%, p<0.001). The POCO incidence was comparable between the FFR- and IVUS-guided deferral strategies (5.9% vs. 3.4%, p=0.479).Conversely, 351 patients with DS <60% underwent PCI according to positive FFR (n=118) and positive IVUS (n=233) (12.8% vs. 25.9%, p<0.001). FFR- and IVUS-guided PCI did not differ in the incidence of POCO (9.5% vs. 6.5%, p=0.294).
Conclusions
The proportion of QCA-FFR or IVUS discordance was approximately one third for intermediate coronary lesions. FFR- or IVUS-guided strategies for these lesions were comparable with respect to POCO at 24 months.
10.Amplification of distinct α-synuclein fibril conformers through protein misfolding cyclic amplification.
Byung Chul JUNG ; Yoon Ju LIM ; Eun Jin BAE ; Jun Sung LEE ; Min Sun CHOI ; Michael K LEE ; He Jin LEE ; Yoon Suk KIM ; Seung Jae LEE
Experimental & Molecular Medicine 2017;49(4):e314-
Amyloid fibril formation has been implicated in the pathogenesis of neurodegenerative diseases. Fibrillation generates numerous conformers. Presumably, the conformers may possess specific biological properties, thus providing a biochemical framework for strains of prions. However, the precise relationship between various fibril conformers and their pathogenic functions has not been determined because of limited accessibility to adequate amounts of fibrils from tissue samples. α-Synuclein is one such protein, and it has been implicated in Parkinson disease. Using a technique known as protein misfolding cyclic amplification, originally developed for amplifying prions, we established a procedure through which the amplification of α-synuclein fibrils is possible. With a trace amount of seeds, we succeeded in amplifying α-synuclein fibrils. The replication of the seeds was faithful in terms of conformation even after multiple rounds of cyclic amplification. Moreover, two transgenic mouse strains each representing a distinct synucleinopathy were used to investigate different conformers by using this technique. The amplified α-synuclein fibrils derived from the tissue extracts of these two strains led to the production of two different fibril conformers with distinct proteinase K digestion profiles. Together, our results demonstrated that a trace amount of α-synuclein fibrils in tissue extracts could be amplified with their conformations conserved. This procedure should be useful in amplifying α-synuclein fibrils from the brains and body fluids of patients afflicted with synucleinopathies and may serve as a potential diagnostic tool for Parkinson disease and other synucleinopathies.
Amyloid
;
Animals
;
Body Fluids
;
Brain
;
Digestion
;
Endopeptidase K
;
Humans
;
Mice
;
Mice, Transgenic
;
Neurodegenerative Diseases
;
Parkinson Disease
;
Prions
;
Tissue Extracts

Result Analysis
Print
Save
E-mail