1.Effect of The Hydrophilic Amino Acids on Self-assembly Behavior of Short Bola-like Peptides
Xin-Xin GAO ; Yu HAN ; Yi-Lin ZHOU ; Xi-Ya CHEN ; Yu-Rong ZHAO
Progress in Biochemistry and Biophysics 2025;52(5):1290-1301
ObjectiveBola-like short peptides exhibit novel self-assembly properties due to the formation of peptide dimers via hydrogen bonding interactions between their C-terminals. In this configuration, hydrophilic amino acids are distributed at both terminals, making these peptides behave similarly to Bola peptides. The electrostatic repulsive interactions arising from the hydrophilic amino acids at each terminal can be neutralized, thereby greatly promoting the lateral association of β-sheets. Consequently, assemblies with significantly larger widths are typically the dominant nanostructures for Bola-like peptides. To investigate the effect of hydrophilic amino acids on the self-assembly behavior of Bola-like peptides, the peptides Ac-RI3-CONH2 and Ac-HI3-CONH2 were designed and synthesized using the Bola-like peptide Ac-KI3-CONH2 as a template. Their self-assembly behavior was systematically examined. MethodsAtomic force microscopy (AFM) and transmission electron microscopy (TEM) were employed to characterize the morphology and size of the assemblies. The secondary structures of the assemblies were analyzed using circular dichroism (CD) and Fourier transform infrared (FTIR) spectroscopy. Small-angle neutron scattering (SANS) was used to obtain detailed structural information at a short-length scale. Based on these experimental results, the effects of hydrophilic amino acids on the self-assembly behavior of Bola-like short peptides were systematically analyzed, and the underlying formation mechanism was explored. ResultsThe aggregation process primarily involved three steps. First, peptide dimers were formed through hydrogen bonding interactions between their C-terminals. Within these dimers, the hydrophilic amino acids K, R, and H were positioned at both terminals, enabling the peptides to self-assemble in a manner similar to Bola peptides. Next, β-sheets were formed via hydrogen bonding interactions along the peptide backbone. Finally, self-assemblies were generated through the lateral association of β-sheets. The results demonstrated that both Ac-KI3-CONH2 and Ac-RI3-CONH2 could self-assemble into double-layer nanotubes with diameters of approximately 200 nm. These nanotubes were formed by the edge fusion of helical ribbons, which initially emerged from twisted ribbons. Notably, the primary assemblies of these peptides exhibited opposite chirality: nanofibers formed by Ac-KI3-CONH2 displayed left-handed chirality, whereas those formed by Ac-RI3-CONH2 exhibited right-handed chirality. This reversal in torsional direction was primarily attributed to the different abilities of K and R to form hydrogen bonds with water. In contrast, Ac-HI3-CONH2 formed narrower twisted ribbons with a significantly reduced width of approximately 30 nm, which was attributed to the strong steric hindrance caused by the imidazole rings. The multilayer height of these ribbons was mainly due to the unique structure of the imidazole rings, which can function as both hydrogen bond donors and acceptors, thereby promoting aggregate growth in the vertical direction. ConclusionThe final morphology of the self-assemblies resulted from a delicate balance of various non-covalent interactions. By altering the types of hydrophilic amino acid residues in Bola-like short peptides, the relative strength of non-covalent interactions that drive assembly formation can be effectively regulated, allowing precise control over the morphology and chirality of the assemblies. This study provides a simple and effective approach for constructing diverse self-assemblies and lays a theoretical foundation for the development of functional biomaterials.
2.Clinical guidelines for indications, techniques, and complications of autogenous bone grafting.
Jianzheng ZHANG ; Shaoguang LI ; Hongying HE ; Li HAN ; Simeng ZHANG ; Lin YANG ; Wenxing HAN ; Xiaowei WANG ; Jie GAO ; Jianwen ZHAO ; Weidong SHI ; Zhuo WU ; Hao WANG ; Zhicheng ZHANG ; Licheng ZHANG ; Wei CHEN ; Qingtang ZHU ; Tiansheng SUN ; Peifu TANG ; Yingze ZHANG
Chinese Medical Journal 2024;137(1):5-7
3.Current status of cognition and skin care behavior in adolescent patients with acne: A survey in China.
Jing TIAN ; Hong SHU ; Qiufang QIAN ; Zhong SHEN ; Chunyu ZHAO ; Li SONG ; Ping LI ; Xiuping HAN ; Hua QIAN ; Jinping CHEN ; Hua WANG ; Lin MA ; Yuan LIANG
Chinese Medical Journal 2024;137(4):476-477
4.A comparative analysis of vaccine immunity induced by heterologous booster with Ad5-nCoV via different routes of administration
Wenxuan MA ; Yuhong HAN ; Ang LIN ; Weijun ZHAO
Journal of China Pharmaceutical University 2024;55(1):137-146
Abstract: Heterologous boost COVID-19 vaccination can solved the problem of decreased efficacy caused by single dose of vaccine. Heterologous booster with adenoviral-vectored COVID-19 vaccine (Ad5-nCoV) following primary immunization with inactivated COVID-19 vaccines is a widely-used vaccination strategy in clinic, while different routes of Ad5-nCoV administration exist and pose a question which route could be more optimal. In this study, we comprehensively evaluated and compared the vaccine immunity induced in mice immunized according to three different vaccination regimens: “3×phosphate buffered solution(3× PBS)”, “2×inactivated vaccine + 1×inactivated vaccine (3×INA)”, “2×inactivated vaccine + 1×Ad5-nCoV (intramuscular)[2×INA+Ad5(im)]”and“2×inactivated vaccine + 1×Ad5-nCoV (intranasal)[2×INA+Ad5(in)]”. We found that heterologous booster with Ad5-nCoV, irrespective of the route of administration, induced significantly higher levels of anti-Spike IgG and subclasses (IgG1and IgG2c), Spike-specific T cells, class-switched Spike+ memory B cells (MBCs) than homologous booster with 3rd dose of inactivated COVID-19 vaccine. Of note, compared with the intramuscular given, intranasal given of Ad5-nCoV as a booster dose clearly induced higher levels of serum and bronchoalveolar bavage fluid anti-spike immunoglobulin A, and moreover, induced stronger infiltration of major innate effector cells like neutrophils, natural killer cells and dendritic cells into the lung tissue, which suggested that mucosal vaccine responses are generated upon intranasal booster with Ad5-nCoV. Altogether, our study analyzed the vaccine immunity induced by different COVID-19 vaccines administered using different regimens, which may guide the clinical use of other types of prophylactic vaccines aiming to mount improved vaccine responses.
5.Preparation and Recognition Features of Molecularly Imprinted Polymer Membrane for Lamotrigine in Plasma
Dong-Yu LU ; Yu-Xin YOU ; Yan-Lin ZHAO ; Han JIANG ; Ying ZHANG ; Yan DU ; Dao-Quan TANG
Chinese Journal of Analytical Chemistry 2024;52(1):80-92
The molecularly imprinted polymers membranes(MIPMs)were prepared for selective adsorption of lamotrigine(LTG)in plasma by surface molecular imprinting technology with polyvinylidenefluoride(PVDF)membranes as supporter,lamotrigine as template molecule,methyl methacrylate as functional monomer,ethylene glycol dimethacrylate as cross-linking agent,azodiisobutyronitrile as initiator and acetonitrile-dimethylformamide(1∶1.5,V/V)as pore-forming agent.The prepared MIPMs were characterized by scanning electron microscope,Fourier transform infrared spectroscopy,Brunaner-emmet-teller measurements,X-ray photoelectron spectroscopy,and thermogravimetric analysis.The adsorption properties of the materials were investigated by kinetic adsorption,isothermal adsorption,selective adsorption,adsorption-desorption and reusability experiments.The results showed that the imprinted layer of LTG was successfully coated on the surface of PVDF,and the materials had uniform particle size.The adsorption capacity and imprinting factor of the MIPMs towards LTG were 3.77 mg/g and 8.97,respectively.The nanomaterials showed fast mass transfer rate(30 min)and good reusability(the adsorption efficiency was 86.66%after 6 cycles),and could be used for the adsorption of LTG in plasma with low matrix interference,recoveries of 86.54%-90.48%and RSD of 1.51%-3.15%(n=5).The proposed LTG MIPMs were demonstrated to be simple and environment friendly,and had high selectivity in rapid separation and extraction of LTG in plasma.
6.Identification of Phenolic Acid Derivatives in Danshen Using MS3 and MS2 Spectra Matching Strategy
Han LI ; Ke ZHANG ; Ting LI ; Wei CHEN ; Jun LI ; Peng-Fei TU ; Yun-Fang ZHAO ; Yue-Lin SONG
Chinese Journal of Analytical Chemistry 2024;52(2):267-276,中插19-中插27
"MS/MS spectrum to structure"plays a critical role in the confirmative identification of complicated matrices and is currently regarded as an extremely challenging endeavor.MS/MS information provides vital clues to structural identification.In this study,a strategy was proposed to facilitate unambiguous identification through matching MS3 with MS2 spectra.Initially,MS3 spectra of the featured ions(c-and y-type ions)generated by the decomposition of ester functional group in esters and the MS2 spectrum of the structural unit([M-H]-)were all captured on the Qtrap-MS platform equipped with two tandem-in-space collision cells,including the second quadrupole cell(q2)and linear ion trap(LIT)chambers(actually the third quadrupole unit).Subsequently,the MS/MS spectrum matching between MS3 spectra of the ester compound and MS2 spectra of the structural unit(s)were achieved.As a result,the findings corresponding to MS3 and MS2 spectra matching were summarized.Finally,based on HR-MS/MS information of total salvianolic acid derivatives(TSA),36 kinds of compounds were preliminarily identified through matching with literature information and database retrieval.The applicability of MS3 and MS2 spectra matching strategy was further justified by the confirmative identification of phenolic acid compounds(Rosmarinic acid and salvianolic acid B)in TSA.Above all,MS3 and MS2 spectra matching strategy was quite meaningful towards advancing"MS/MS spectrum to structure"analysis through recognizing and identifying featured fragment ions,and also provided inspiration and new insights for the structural characterization.
7.Study on Rapid Detection Methods of Acid Yellow 36 in Moxibustion
Peijing ZHAO ; Lin CHEN ; Ying SONG ; Zhong' ; e LI ; Han HUANG
Chinese Journal of Modern Applied Pharmacy 2024;41(11):1524-1528
OBJECTIVE
To establish a rapid method for determining of acid yellow 36 in moxibustion.
METHODS
Based on the principle of acid yellow 36 as an acid-base indicator and discoloration in the pH range of 1.2(red) to 2.3(yellow), 15% sulfuric acid solution was used as the color developing agent to screen the ethanol extract of the sample, and then HPLC method was used to verify the suspicious positive samples in the initial screening, and finally LC-MS method was used to confirm the accuracy of the established rapid physicochemical detection method.
RESULTS
The established method was applied to 67 batches of samples, and 3 positive samples were detected. The results were consistent with those of HPLC and LC-MS.
CONCLUSION
The method is accurate and sensitive, which can be used for rapid detection of acid yellow 36 in moxibustion.
8.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
9.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
10.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.


Result Analysis
Print
Save
E-mail