1.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.Biomarkers Screening and Mechanisms Analysis of the Restraint Stress-Induced Myocardial Injury in Hyperlipidemia ApoE-/-Mice
Shang-Heng CHEN ; Sheng-Zhong DONG ; Zhi-Min WANG ; Guang-Hui HONG ; Xing YE ; Zi-Jie LIN ; Jun-Yi LIN ; Jie-Qing JIANG ; Shou-Yu WANG ; Han-Cheng LIN ; Yi-Wen SHEN
Journal of Forensic Medicine 2024;40(2):172-178
Objective To explore the biomarkers and potential mechanisms of chronic restraint stress-induced myocardial injury in hyperlipidemia ApoE-/-mice.Methods The hyperlipidemia combined with the chronic stress model was established by restraining the ApoE-/-mice.Proteomics and bioinformatics techniques were used to describe the characteristic molecular changes and related regulatory mechanisms of chronic stress-induced myocardial injury in hyperlipidemia mice and to explore potential diagnostic biomarkers.Results Proteomic analysis showed that there were 43 significantly up-regulated and 58 sig-nificantly down-regulated differentially expressed proteins in hyperlipidemia combined with the restraint stress group compared with the hyperlipidemia group.Among them,GBP2,TAOK3,TFR1 and UCP1 were biomarkers with great diagnostic potential.KEGG pathway enrichment analysis indicated that fer-roptosis was a significant pathway that accelerated the myocardial injury in hyperlipidemia combined with restraint stress-induced model.The mmu_circ_0001567/miR-7a/Tfr-1 and mmu_circ_0001042/miR-7a/Tfr-1 might be important circRNA-miRNA-mRNA regulatory networks related to ferroptosis in this model.Conclusion Chronic restraint stress may aggravate myocardial injury in hyperlipidemia mice via ferrop-tosis.Four potential biomarkers are selected for myocardial injury diagnosis,providing a new direction for sudden cardiac death(SCD)caused by hyperlipidemia combined with the restraint stress.
6.Establishment and application of the ten-fold rehydration formula for emergency resuscitation of pediatric patients after extensive burns.
Zhuan An SHEN ; Xin Zhu LIU ; Xiao Ye XIE ; Bo Han ZHANG ; Da Wei LI ; Zhao Xing LIU ; Hua Geng YUAN
Chinese Journal of Burns 2023;39(1):59-64
Objective: To investigate the scientificity and feasibility of the ten-fold rehydration formula for emergency resuscitation of pediatric patients after extensive burns. Methods: A retrospective observational study was conducted. The total burn area of 30%-100% total body surface area (TBSA) and body weight of 6-50 kg in 433 pediatric patients (250 males and 183 females, aged 3 months to 14 years) with extensive burns who met the inclusion criteria and admitted to the burn departments of 72 Class A tertiary hospitals were collected. The 6 319 pairs of simulated data were constructed after pairing each body weight of 6-50 kg (programmed in steps of 0.5 kg) and each total burn area of 30%-100% TBSA (programmed in steps of 1%TBSA). They were put into three accepted pediatric rehydration formulae, namely the commonly used domestic pediatric rehydration formula for burn patients (hereinafter referred to as the domestic rehydration formula), the Galveston formula, and the Cincinnati formula, and the two rehydration formulae for pediatric emergency, namely the simplified resuscitation formula for emergency care of patients with extensive burns proposed by the World Health Organization's Technical Working Group on Burns (TWGB, hereinafter referred to as the TWGB formula) and the pediatric ten-fold rehydration formula proposed by the author of this article--rehydration rate (mL/h)=body weight (kg) × 10 (mL·kg-1·h-1) to calculate the rehydration rate within 8 h post injury (hereinafter referred to as the rehydration rate). The range of the results of the 3 accepted pediatric rehydration formulae ±20% were regarded as the reasonable rehydration rate, and the accuracy rates of rehydration rate calculated using the two pediatric emergency rehydration formulae were compared. Using the maximum burn areas (55% and 85% TBSA) corresponding to the reasonable rehydration rate calculated by the pediatric ten-fold rehydration formula at the body weight of 6 and 50 kg respectively, the total burn area of 30% to 100% TBSA was divided into 3 segments and the accuracy rates of the rehydration rate calculated using the 2 pediatric emergency rehydration formulae in each segment were compared. When neither of the rehydration rates calculated by the 2 pediatric emergency rehydration formulae was reasonable, the differences between the two rehydration rates were compared. The distribution of 433 pediatric patients in the 3 previous total burn area segments was counted and the accuracy rates of the rehydration rate calculated using the 2 pediatric emergency rehydration formulae were calculated and compared. Data were statistically analyzed with McNemar test. Results: Substitution of 6 319 pairs of simulated data showed that the accuracy rates of the rehydration rates calculated by the pediatric ten-fold rehydration formula was 73.92% (4 671/6 319), which was significantly higher than 4.02% (254/6 319) of the TWGB formula (χ2=6 490.88,P<0.05). When the total burn area was 30%-55% and 56%-85% TBSA, the accuracy rates of the rehydration rates calculated by the pediatric ten-fold rehydration formula were 100% (2 314/2 314) and 88.28% (2 357/2 670), respectively, which were significantly higher than 10.98% (254/2 314) and 0 (0/2 670) of the TWGB formula (with χ2 values of 3 712.49 and 4 227.97, respectively, P<0.05); when the total burn area was 86%-100% TBSA, the accuracy rates of the rehydration rates calculated by the pediatric ten-fold rehydration formula and the TWGB formula were 0 (0/1 335). When the rehydration rates calculated by the 2 pediatric emergency rehydration formulae were unreasonable, the rehydration rates calculated by the pediatric ten-fold rehydration formula were all higher than those of the TWGB formula. There were 93.07% (403/433), 5.77% (25/433), and 1.15% (5/433) patients in the 433 pediatric patients had total burn area of 30%-55%, 56%-85%, and 86%-100% TBSA, respectively, and the accuracy rate of the rehydration rate calculated using the pediatric ten-fold rehydration formula was 97.69% (423/433), which was significantly higher than 0 (0/433) of the TWGB formula (χ2=826.90, P<0.05). Conclusions: The application of the pediatric ten-fold rehydration formula to estimate the rehydration rate of pediatric patients after extensive burns is more accurate and convenient, superior to the TWGB formula, suitable for application by front-line healthcare workers that are not specialized in burns in pre-admission rescue of pediatric patients with extensive burns, and is worthy of promotion.
Male
;
Female
;
Humans
;
Child
;
Burns/therapy*
;
Hospitalization
;
Resuscitation
;
Fluid Therapy/methods*
;
Body Surface Area
;
Retrospective Studies
7.Predictive value of MRI radiologic extranodal extension for distant metastasis of prostate cancer
Fan SHEN ; Ye HAN ; Zunjian XIAO ; Bao CUI ; Jianhua JIAO ; Jingliang ZHANG ; Weijun QIN ; Yi HUAN ; Jing REN
Chinese Journal of Radiology 2023;57(11):1215-1221
Objective:To investigate the predictive value of MRI radiologic extranodal extension (rENE) for distant metastasis of prostate cancer (PCa).Methods:The data of 107 patients of initial visit with clinically diagnosed N1 PCa who underwent MRI and 68Ga-prostate specific membrane antigen (PSMA) PET/CT examinations were retrospectively analyzed at Xijing Hospital, Air Force Medical University from January 2017 to April 2022. The rENE was evaluated with MRI. According to the results of 68Ga-PSMA PET/CT, the patients were divided into the distant metastasis group (group M1, 87 cases) and the non-distant metastasis group (group M0, 20 cases). Independent sample t test, Mann-Whitney U test or χ 2 test were used to compare the differences in clinical indicators and rENE between the two groups. The multivariate logistic regression analysis was used to screen the independent risk factors affecting distant metastasis. The receiver operating characteristic (ROC) curve was used to evaluate the predictive efficacy of independent risk factors for PCa distant metastasis. Results:In group M1, 72 cases (82.8%) were rENE positive and 15 cases (17.2%) were rENE negative, and in group M0, 7 cases (35.0%) were rENE positive and 13 cases (65.0%) were rENE negative, and there was a statistically significant difference in rENE between the two groups (χ 2=19.20, P<0.001). There were significant differences in total prostate specific antigen level, International Society of Urological Pathology grade and T stage between the group M1 and the group M0 ( P<0.05). Multivariate logistic regression analysis showed that rENE (OR=6.248, 95%CI 1.807-21.600, P=0.004) was an independent risk factor for distant metastasis of PCa, and the area under the ROC curve of rENE in the diagnosis of distant metastasis of PCa was 0.739 (95%CI 0.607-0.871), the sensitivity was 82.8%, and the specificity was 65.0%. Conclusion:rENE is an independent predictor of distant metastasis of PCa, which has a high efficacy. Compared with patients with rENE negative, PCa patients with rENE positive have a higher degree of invasion and are more likely to have distant metastasis.
8.Cloning, induction pattern and prokaryotic expression of a small heat shock protein SmHSP21.8 gene from Salvia miltiorrhiza
Shi-wei WANG ; Ren-jun QU ; Jia-ming PENG ; Xin-xin WANG ; Chen-jing SHI ; Han ZHENG ; Ye SHEN ; Lu-qi HUANG
Acta Pharmaceutica Sinica 2022;57(6):1909-1917
In order to reveal the molecular mechanism of the small heat shock proteins (sHSPs) involved in stress resistance and active ingredients accumulation in
9.Clinical treatment outcomes and their changes in extremely preterm twins: a multicenter retrospective study in Guangdong Province, China.
Bi-Jun SHI ; Ying LI ; Fan WU ; Zhou-Shan FENG ; Qi-Liang CUI ; Chuan-Zhong YANG ; Xiao-Tong YE ; Yi-Heng DAI ; Wei-Yi LIANG ; Xiu-Zhen YE ; Jing MO ; Lu DING ; Ben-Qing WU ; Hong-Xiang CHEN ; Chi-Wang LI ; Zhe ZHANG ; Xiao RONG ; Wei SHEN ; Wei-Min HUANG ; Bing-Yan YANG ; Jun-Feng LYU ; Hui-Wen HUANG ; Le-Ying HUO ; Hong-Ping RAO ; Wen-Kang YAN ; Xue-Jun REN ; Yong YANG ; Fang-Fang WANG ; Dong LIU ; Shi-Guang DIAO ; Xiao-Yan LIU ; Qiong MENG ; Yu WANG ; Bin WANG ; Li-Juan ZHANG ; Yu-Ge HUANG ; Dang AO ; Wei-Zhong LI ; Jie-Ling CHEN ; Yan-Ling CHEN ; Wei LI ; Zhi-Feng CHEN ; Yue-Qin DING ; Xiao-Yu LI ; Yue-Fang HUANG ; Ni-Yang LIN ; Yang-Fan CAI ; Sha-Sha HAN ; Ya JIN ; Guo-Sheng LIU ; Zhong-He WAN ; Yi BAN ; Bo BAI ; Guang-Hong LI ; Yue-Xiu YAN
Chinese Journal of Contemporary Pediatrics 2022;24(1):33-40
OBJECTIVES:
To investigate the clinical treatment outcomes and the changes of the outcomes over time in extremely preterm twins in Guangdong Province, China.
METHODS:
A retrospective analysis was performed for 269 pairs of extremely preterm twins with a gestational age of <28 weeks who were admitted to the department of neonatology in 26 grade A tertiary hospitals in Guangdong Province from January 2008 to December 2017. According to the admission time, they were divided into two groups: 2008-2012 and 2013-2017. Besides, each pair of twins was divided into the heavier infant and the lighter infant subgroups according to birth weight. The perinatal data of mothers and hospitalization data of neonates were collected. The survival rate of twins and the incidence rate of complications were compared between the 2008-2012 and 2013-2017 groups.
RESULTS:
Compared with the 2008-2012 group, the 2013-2017 group (both the heavier infant and lighter infant subgroups) had lower incidence rates of severe asphyxia and smaller head circumference at birth (P<0.05). The mortality rates of both of the twins, the heavier infant of the twins, and the lighter infant of the twins were lower in the 2013-2017 group compared with the 2008-2012 group (P<0.05). Compared with the 2008-2012 group, the 2013-2017 group (both the heavier infant and lighter infant subgroups) had lower incidence rates of pulmonary hemorrhage, patent ductus arteriosus (PDA), periventricular-intraventricular hemorrhage (P-IVH), and neonatal respiratory distress syndrome (NRDS) and a higher incidence rate of bronchopulmonary dysplasia (P<0.05).
CONCLUSIONS
There is a significant increase in the survival rate over time in extremely preterm twins with a gestational age of <28 weeks in the 26 grade A tertiary hospitals in Guangdong Province. The incidences of severe asphyxia, pulmonary hemorrhage, PDA, P-IVH, and NRDS decrease in both the heavier and lighter infants of the twins, but the incidence of bronchopulmonary dysplasia increases. With the improvement of diagnosis and treatment, the multidisciplinary collaboration between different fields of fetal medicine including prenatal diagnosis, obstetrics, and neonatology is needed in the future to jointly develop management strategies for twin pregnancy.
Bronchopulmonary Dysplasia/epidemiology*
;
Female
;
Gestational Age
;
Humans
;
Infant
;
Infant, Extremely Premature
;
Infant, Newborn
;
Pregnancy
;
Respiratory Distress Syndrome, Newborn/epidemiology*
;
Retrospective Studies
;
Treatment Outcome
10.Preliminary analysis of the promotion effect of laparoscopic standardized surgical treatment for gastric cancer in regional medical centers in Shanghai.
Xiao Dong SHEN ; Ming XU ; Chang SU ; Min YE ; Wei LI ; Zhen Xi YANG ; Jiang HAN ; Zhi Qi ZHANG ; Hong Gang XIANG ; Lin Hai YU ; Peng SUN ; Wen Hai HUANG ; Bo Wen XIE ; Ying Xin GUAN ; Zeng Hao CAI ; Wenpeng ZHANG ; Lu ZANG
Chinese Journal of Gastrointestinal Surgery 2022;25(8):708-715
Objective: To explore the promotion effect of laparoscopic standardized surgery for gastric cancer observational in some regional medical centers in Shanghai. Methods: A retrospective cohort study was carried out. Eleven regional medical centers in Shanghai received the promotion program of laparoscopic standardized surgery for gastric cancer, which was led by Ruijin Hospital, Shanghai Jiaotong University School of Medicine (Shanghai Minimally Invasive Surgery Center) from January to December 2020. Clinicopathological data of gastric cancer patients treated at these 11 regional medical centers before and after the promotion program were collected. Inclusion criteria were as follows: patients undergoing laparoscopic distal gastrectomy or total gastrectomy; gastric cancer confirmed by pathology; without distant metastasis or peritoneal metastasis. Patients who did not undergo laparoscopic D2 radical resection, or received neoadjuvant chemotherapy before surgery, or without complete clinical data were excluded. Patients undergoing laparoscopic surgery from January to December 2019 were included in the pre-promotion group (46 cases). Patients undergoing laparoscopic surgery from January to December 2021 were included in the post-promotion group (102 cases). In addition, patients undergoing laparoscopic surgery at Ruijin Hospital from January 2021 to December were included in the control group (138 cases). The baseline data, perioperative measurements postoperative complications, and pathological results of the three groups were analyzed and compared. Results: There were no significant differences in baseline characteristics among the three groups (all P>0.05). Compared with the pre-promotion group, the operation time in post-promotion group was significantly shorter [(207.3±36.0) minutes vs. (254.2±47.1) minutes, t=7.038,P<0.001], and the number of harvested lymph node was significantly more (24.4±12.2 vs. 18.9±5.5, t=2.900, P=0.004). However, there were no significant differences in the extent of resection, time to fluid intake, and postoperative hospital stay between the two groups (all P>0.05). Compared with the control group, the operation time [(207.3±36.0) minutes vs (172.6±26.0) minutes, t=8.281, P<0.001], time to fluid intake [(6.3±3.2) days than (5.5±3.0) days, t=2.029, P=0.044], and the postoperative hospital stay [(14.3±5.6) days vs. (10.1±4.8) days, t=6.036, P<0.001] in the post- promotion group were still longer. Total gastrectomy was less common in the post-promotion group compared with the control group [18 cases (17.6%) vs. 41 cases (29.7%), χ2=7.380, P=0.007]. However, there was no significant difference in the number of harvested lymph node between the two groups (P>0.05). The morbidity of postoperative complication in the post-promotion group (9.8%, 10/102) was significantly lower than that in the pre-promotion group (23.9%, 11/46) (χ2=5.183, P=0.023), while above morbidity was not significantly different between the post-promotion group and the control group [9.8% vs. 6.5% (9/138), χ2=0.867, P=0.352]. Conclusion: After the promotion of laparoscopic standardized surgery for gastric cancer in regional medical centers, the standardization degree of surgery has been improved, and the morbidity of postoperative complication decreases. Laparoscopic standardized surgery for gastric cancer can be promoted to more regional medical centers.
China
;
Gastrectomy/methods*
;
Hospitals
;
Humans
;
Laparoscopy
;
Lymph Node Excision/methods*
;
Postoperative Complications/etiology*
;
Retrospective Studies
;
Stomach Neoplasms/pathology*
;
Treatment Outcome

Result Analysis
Print
Save
E-mail