1.Clinical practice guidelines for intraoperative cell salvage in patients with malignant tumors
Changtai ZHU ; Ling LI ; Zhiqiang LI ; Xinjian WAN ; Shiyao CHEN ; Jian PAN ; Yi ZHANG ; Xiang REN ; Kun HAN ; Feng ZOU ; Aiqing WEN ; Ruiming RONG ; Rong XIA ; Baohua QIAN ; Xin MA
Chinese Journal of Blood Transfusion 2025;38(2):149-167
Intraoperative cell salvage (IOCS) has been widely applied as an important blood conservation measure in surgical operations. However, there is currently a lack of clinical practice guidelines for the implementation of IOCS in patients with malignant tumors. This report aims to provide clinicians with recommendations on the use of IOCS in patients with malignant tumors based on the review and assessment of the existed evidence. Data were derived from databases such as PubMed, Embase, the Cochrane Library and Wanfang. The guideline development team formulated recommendations based on the quality of evidence, balance of benefits and harms, patient preferences, and health economic assessments. This study constructed seven major clinical questions. The main conclusions of this guideline are as follows: 1) Compared with no perioperative allogeneic blood transfusion (NPABT), perioperative allogeneic blood transfusion (PABT) leads to a more unfavorable prognosis in cancer patients (Recommended); 2) Compared with the transfusion of allogeneic blood or no transfusion, IOCS does not lead to a more unfavorable prognosis in cancer patients (Recommended); 3) The implementation of IOCS in cancer patients is economically feasible (Recommended); 4) Leukocyte depletion filters (LDF) should be used when implementing IOCS in cancer patients (Strongly Recommended); 5) Irradiation treatment of autologous blood to be reinfused can be used when implementing IOCS in cancer patients (Recommended); 6) A careful assessment of the condition of cancer patients (meeting indications and excluding contraindications) should be conducted before implementing IOCS (Strongly Recommended); 7) Informed consent from cancer patients should be obtained when implementing IOCS, with a thorough pre-assessment of the patient's condition and the likelihood of blood loss, adherence to standardized internally audited management procedures, meeting corresponding conditions, and obtaining corresponding qualifications (Recommended). In brief, current evidence indicates that IOCS can be implemented for some malignant tumor patients who need allogeneic blood transfusion after physician full evaluation, and LDF or irradiation should be used during the implementation process.
2.Effect of The Hydrophilic Amino Acids on Self-assembly Behavior of Short Bola-like Peptides
Xin-Xin GAO ; Yu HAN ; Yi-Lin ZHOU ; Xi-Ya CHEN ; Yu-Rong ZHAO
Progress in Biochemistry and Biophysics 2025;52(5):1290-1301
ObjectiveBola-like short peptides exhibit novel self-assembly properties due to the formation of peptide dimers via hydrogen bonding interactions between their C-terminals. In this configuration, hydrophilic amino acids are distributed at both terminals, making these peptides behave similarly to Bola peptides. The electrostatic repulsive interactions arising from the hydrophilic amino acids at each terminal can be neutralized, thereby greatly promoting the lateral association of β-sheets. Consequently, assemblies with significantly larger widths are typically the dominant nanostructures for Bola-like peptides. To investigate the effect of hydrophilic amino acids on the self-assembly behavior of Bola-like peptides, the peptides Ac-RI3-CONH2 and Ac-HI3-CONH2 were designed and synthesized using the Bola-like peptide Ac-KI3-CONH2 as a template. Their self-assembly behavior was systematically examined. MethodsAtomic force microscopy (AFM) and transmission electron microscopy (TEM) were employed to characterize the morphology and size of the assemblies. The secondary structures of the assemblies were analyzed using circular dichroism (CD) and Fourier transform infrared (FTIR) spectroscopy. Small-angle neutron scattering (SANS) was used to obtain detailed structural information at a short-length scale. Based on these experimental results, the effects of hydrophilic amino acids on the self-assembly behavior of Bola-like short peptides were systematically analyzed, and the underlying formation mechanism was explored. ResultsThe aggregation process primarily involved three steps. First, peptide dimers were formed through hydrogen bonding interactions between their C-terminals. Within these dimers, the hydrophilic amino acids K, R, and H were positioned at both terminals, enabling the peptides to self-assemble in a manner similar to Bola peptides. Next, β-sheets were formed via hydrogen bonding interactions along the peptide backbone. Finally, self-assemblies were generated through the lateral association of β-sheets. The results demonstrated that both Ac-KI3-CONH2 and Ac-RI3-CONH2 could self-assemble into double-layer nanotubes with diameters of approximately 200 nm. These nanotubes were formed by the edge fusion of helical ribbons, which initially emerged from twisted ribbons. Notably, the primary assemblies of these peptides exhibited opposite chirality: nanofibers formed by Ac-KI3-CONH2 displayed left-handed chirality, whereas those formed by Ac-RI3-CONH2 exhibited right-handed chirality. This reversal in torsional direction was primarily attributed to the different abilities of K and R to form hydrogen bonds with water. In contrast, Ac-HI3-CONH2 formed narrower twisted ribbons with a significantly reduced width of approximately 30 nm, which was attributed to the strong steric hindrance caused by the imidazole rings. The multilayer height of these ribbons was mainly due to the unique structure of the imidazole rings, which can function as both hydrogen bond donors and acceptors, thereby promoting aggregate growth in the vertical direction. ConclusionThe final morphology of the self-assemblies resulted from a delicate balance of various non-covalent interactions. By altering the types of hydrophilic amino acid residues in Bola-like short peptides, the relative strength of non-covalent interactions that drive assembly formation can be effectively regulated, allowing precise control over the morphology and chirality of the assemblies. This study provides a simple and effective approach for constructing diverse self-assemblies and lays a theoretical foundation for the development of functional biomaterials.
3.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
4.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
5.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
6.Expert consensus on clinical application of 177Lu-prostate specific membrane antigen radio-ligand therapy in prostate cancer
Guobing LIU ; Weihai ZHUO ; Yushen GU ; Zhi YANG ; Yue CHEN ; Wei FAN ; Jianming GUO ; Jian TAN ; Xiaohua ZHU ; Li HUO ; Xiaoli LAN ; Biao LI ; Weibing MIAO ; Shaoli SONG ; Hao XU ; Rong TIAN ; Quanyong LUO ; Feng WANG ; Xuemei WANG ; Aimin YANG ; Dong DAI ; Zhiyong DENG ; Jinhua ZHAO ; Xiaoliang CHEN ; Yan FAN ; Zairong GAO ; Xingmin HAN ; Ningyi JIANG ; Anren KUANG ; Yansong LIN ; Fugeng LIU ; Cen LOU ; Xinhui SU ; Lijun TANG ; Hui WANG ; Xinlu WANG ; Fuzhou YANG ; Hui YANG ; Xinming ZHAO ; Bo YANG ; Xiaodong HUANG ; Jiliang CHEN ; Sijin LI ; Jing WANG ; Yaming LI ; Hongcheng SHI
Chinese Journal of Clinical Medicine 2024;31(5):844-850,封3
177Lu-prostate specific membrane antigen(PSMA)radio-ligand therapy has been approved abroad for advanced prostate cancer and has been in several clinical trials in China.Based on domestic clinical practice and experimental data and referred to international experience and viewpoints,the expert group forms a consensus on the clinical application of 177Lu-PSMA radio-ligand therapy in prostate cancer to guide clinical practice.
7.Clinical and genetic characteristics of a child with Developmental and Epileptic Encephalopathy 104 due to variant of ATP6V0A1 gene
Chengyan LI ; You WANG ; Siqi CHEN ; Shiwen RONG ; Binglong HUANG ; Ling LIU ; Han LUO
Chinese Journal of Medical Genetics 2024;41(3):345-350
Objective:To explore the clinical phenotype and genetic etiology of a child with Developmental epileptic encephalopathy type 104 (DEE 104).Methods:A child who had presented at the Children′s Medical Center of the Affiliated Hospital of Guangdong Medical University in February 2021 for recurrent seizures over 1 month was selected as the study subject. Clinical data of the child was collected. Peripheral blood samples of the child and his parents were collected and subjected to whole exome sequencing (WES). Candidate variant was verified by Sanger sequencing.Results:The child, a five-month-old male, had presented with frequent focal seizures with severe developmental retardation from infancy. Physical examination showed emaciation, microcephaly, oblique palpebral fissures, Stahl′s ears, and hypotonia in the limbs. Electroencephalogram revealed multi-focal sharp waves, slow waves and slow spinal waves. Cranial magnetic resonance imaging revealed enlargement of bilateral lateral ventricles and the third ventricle, along with widening of brain sulci, fissure and cisterna. WES revealed that he had harbored a heterozygous c. 2401C>T (p.His801Tyr) missense variant of the ATP6V0A1 gene. Sanger sequencing showed that both of his parents were of the wild type. Based on the guidelines from the American College of Medical Genetics and Genomics (ACMG), the variant was predicted to be likely pathogenic (PS2+ PM2_Supporting+ PP3). The proband was diagnosed with DEE 104. Early treatment with sodium valproate has failed, but the child had become seizure free after the addition of levetiracetam and topiramate. He still had abnormal EEG discharges and severe psychomotor retardation. Combining our case and a review of literature, DEE104 is mainly caused by de novo heterozygous variants of the ATP6V0A1 gene with an autosomal dominant inheritance. The patients may show refractory epilepsy and severe global developmental delay from infancy. Conclusion:The c. 2401C>T (p.His801Tyr) variant probably underlay the DEE104 in this child.
8.Clinical analysis of contrast-enhanced ultrasound combined with serum SMURF1 detection in the diagnosis of thyroid cancer
Jin WANG ; Xin CHANG ; Chun-Rong HAN ; Ke WAN ; Hui CHEN ; Jing ZHAO ; Juan XIONG
Journal of Regional Anatomy and Operative Surgery 2024;33(2):153-157
Objective To investigate the diagnostic value of contrast-enhanced ultrasound(CEUS)combined with serum Smad ubiquitin regulatory factor 1(SMURF1)detection for thyroid cancer.Methods A total of 144 suspected thyroid cancer patients admitted to Lishui branch of Zhongda Hospital Affiliated to Southeast University from February 2019 to February 2020 were selected as the study subjects.Based on the histopathological results,they were divided into the thyroid cancer group(76 cases)and the benign group(68 cases).All patients underwent contrast-enhanced ultrasound examination and serum SMURF1 level detection;the diagnostic value of contrast-enhanced ultrasound parameters,serum SMURF1 detection alone,and the combination of the two methods for thyroid cancer were analyzed.Results Contrast-enhanced ultrasound parameters peak intensity(PI),mean perfusion intensity(SImean)and maximum perfusion intensity(SImax)in the thyroid cancer group were lower than those in the benign group,and the level of SMURF1 mRNA was higher than that in the benign group(P<0.05).The sensitivity of contrast-enhanced ultrasound parameter SImax in the diagnosis of thyroid cancer was 82.89%,the specificity was 72.06%,the accuracy was 77.78%,and the Kappa value was 0.552.The sensitivity of serum SMURF1 in the diagnosis of thyroid cancer was 65.79%,the specificity was 94.12%,the accuracy was 79.17%,and the Kappa value was 0.589.The sensitivity,specificity,accuracy and Kappa value of SImax combined with serum SMURF1 in the diagnosis of thyroid cancer were 97.37%,85.29%,91.67%and 0.832,respectively,which were higher than those of SImax and SMURF1 alone(P<0.05),the AUC of the combination of the two methods was 0.927,which was significantly higher than that of the two methods alone(Zcombined vs.SImax=3.999,P<0.001;Zcombined vs.SMURF1=3.270,P=0.001).Conclusion Contrast-enhanced ultrasound combined with serum SMURF1 detection can improve the diagnostic efficiency of thyroid cancer,which may avoid the over-diagnosis on the premise of ensuring the effective diagnosis of thyroid cancer patients.
9.Expert opinions on operation rules of Morita therapy outpatient service
Jiangbo LI ; Zucheng WANG ; Yuhua CUI ; Yingzhi LU ; Weijie QU ; Haiyin ZHANG ; Fuqiang MAO ; Fengqing QIE ; Wanghong SHI ; Qinfeng ZHANG ; Lingyi PAN ; Ling ZHANG ; Jianzhong LI ; Guangcheng CUI ; Tongxian CHEN ; Xiuqing MA ; Wei RONG ; Jianjun ZHANG ; Qingfang ZHONG ; Yanchi ZHANG ; Boquan ZHANG ; Xinrui WANG ; Wenyou MA ; Qingtao REN ; Yongfa JING ; Huanzhong LIU ; Zhenjian YU ; Laitian ZHAO ; Tianming HAN ; Xue HAN
Chinese Mental Health Journal 2024;38(1):68-72
Morita therapy has been bom for more than 100 years.Inpatient Morita therapy is highly oper-able and easy to master.It can improve many refractory neuroses through four-stage treatment.But more neuroses are treated in outpatient clinics,and Morita therapy cannot be used in hospitalized patients.Therefore,the formula-tion of expert opinions on outpatient operations is particularly important.This paper is based on domestic and for-eign references,and after many discussions by domestic Morita therapy experts,and then drew up the first version of the expert opinions on operation of outpatient Morita therapy.Meanwhile the operation rule of Morita therapy in three stages of outpatient treatment was formulated:in the etiological analysis stage,under the theoretical guidance of Morita therapy,analyze the pathogenic factors,to improve treatment compliance and reduce resistance;during the operating stage,guide patients to engage in constructive and meaningful actions,realizing the achievement of letting nature take its course principle;in the cultivating character and enriching life stage,pay attention to positive infor-mation,expanding the scope and content of actions,improving the ability to adapt to complex life,and preventing recurrence caused by insufficient abilities.It will lay a foundation for the promotion of Morita therapy in domestic outpatient clinics,so that more patients with neurosis and other psychological diseases could receive characteristic Morita therapy treatment in outpatient clinics.
10.Treatment status of tyrosine kinase inhibitor for newly-diagnosed chronic myeloid leukemia: a domestic multi-centre retrospective real-world study
Xiaoshuai ZHANG ; Bingcheng LIU ; Xin DU ; Yanli ZHANG ; Na XU ; Xiaoli LIU ; Weiming LI ; Hai LIN ; Rong LIANG ; Chunyan CHEN ; Jian HUANG ; Yunfan YANG ; Huanling ZHU ; Ling PAN ; Xiaodong WANG ; Guohui LI ; Zhuogang LIU ; Yanqing ZHANG ; Zhenfang LIU ; Jianda HU ; Chunshui LIU ; Fei LI ; Wei YANG ; Li MENG ; Yanqiu HAN ; Li'e LIN ; Zhenyu ZHAO ; Chuanqing TU ; Caifeng ZHENG ; Yanliang BAI ; Zeping ZHOU ; Suning CHEN ; Huiying QIU ; Lijie YANG ; Xiuli SUN ; Hui SUN ; Li ZHOU ; Zelin LIU ; Danyu WANG ; Jianxin GUO ; Liping PANG ; Qingshu ZENG ; Xiaohui SUO ; Weihua ZHANG ; Yuanjun ZHENG ; Qian JIANG
Chinese Journal of Hematology 2024;45(3):215-224
Objective:To retrospectively analyze the treatment status of tyrosine kinase inhibitors (TKI) in newly diagnosed patients with chronic myeloid leukemia (CML) in China.Methods:Data of chronic phase (CP) and accelerated phase (AP) CML patients diagnosed from January 2006 to December 2022 from 77 centers, ≥18 years old, and receiving initial imatinib, nilotinib, dasatinib or flumatinib-therapy within 6 months after diagnosis in China with complete data were retrospectively interrogated. The choice of initial TKI, current TKI medications, treatment switch and reasons, treatment responses and outcomes as well as the variables associated with them were analyzed.Results:6 893 patients in CP ( n=6 453, 93.6%) or AP ( n=440, 6.4%) receiving initial imatinib ( n=4 906, 71.2%), nilotinib ( n=1 157, 16.8%), dasatinib ( n=298, 4.3%) or flumatinib ( n=532, 7.2%) -therapy. With the median follow-up of 43 ( IQR 22-75) months, 1 581 (22.9%) patients switched TKI due to resistance ( n=1 055, 15.3%), intolerance ( n=248, 3.6%), pursuit of better efficacy ( n=168, 2.4%), economic or other reasons ( n=110, 1.6%). The frequency of switching TKI in AP patients was significantly-higher than that in CP patients (44.1% vs 21.5%, P<0.001), and more AP patients switched TKI due to resistance than CP patients (75.3% vs 66.1%, P=0.011). Multi-variable analyses showed that male, lower HGB concentration and ELTS intermediate/high-risk cohort were associated with lower cytogenetic and molecular responses rate and poor outcomes in CP patients; higher WBC count and initial the second-generation TKI treatment, the higher response rates; Ph + ACA at diagnosis, poor PFS. However, Sokal intermediate/high-risk cohort was only significantly-associated with lower CCyR and MMR rates and the poor PFS. Lower HGB concentration and larger spleen size were significantly-associated with the lower cytogenetic and molecular response rates in AP patients; initial the second-generation TKI treatment, the higher treatment response rates; lower PLT count, higher blasts and Ph + ACA, poorer TFS; Ph + ACA, poorer OS. Conclusion:At present, the vast majority of newly-diagnosed CML-CP or AP patients could benefit from TKI treatment in the long term with the good treatment responses and survival outcomes.

Result Analysis
Print
Save
E-mail