1.Prevalence of hypertension, blood pressure control and influencing factors in residents aged 35-75 years in Jiangsu Province
Haitao BI ; Jian SU ; Lulu CHEN ; Lan CUI ; Ran TAO ; Jinyi ZHOU ; Yu QIN
Chinese Journal of Epidemiology 2024;45(7):947-954
Objective:To understand the prevalence, blood pressure control, and influencing factors of hypertension in residents aged 35-75 years in Jiangsu Province, and provide data support and basis for hypertension prevention and treatment.Methods:A stratified cluster sampling method was adopted to conduct community population surveys in 22 districts and counties in 12 prefectures in Jiangsu from 2021 to 2022. A total of 123 531 permanent residents aged 35-75 years were included in the study. The questionnaire survey collected the information about the demographic characteristics, disease history, lifestyle, and control of hypertension of study subjects. Statistical software SPSS 23.0 was used for χ2 test and multivariate logistic regression analysis, and Joinpoint 4.9.1.0 software was used to evaluate the trend of age change. Results:The standardized prevalence of hypertension in study subjects was 46.60%, the prevalence was higher in men than in women, and in rural residents than in urban residents, and the standardized blood pressure control rate was 11.24%, and it was lower in men than in women and in rural residents than in urban residents. The hypertension prevalence and control rates showed increasing trends with age (both P<0.001). The multivariate analysis results showed that being man, older age, being rural resident, higher frequency of alcohol consumption, marital status of being separated and widowed, overweight and obese, abdominal obesity and stroke, diabetes mellitus and dyslipidaemic diseases histories, and family history of hypertension were risk factors for hypertension, and being man, being rural resident, living north area, higher frequency of alcohol consumption, and obesity were risk factors for blood pressure control. Conclusions:The prevalence of hypertension in residents aged 35-75 years in Jiangsu was high, and the rate of blood pressure control was low. It is suggested to take integrated intervention measures, especially in in rural residents and people with low levels of education to reduce the disease burden of the patients.
2.Research Progress in Cardiac Imaging Evaluation of Left Ventricular Structure and Function in Atrial Fibrillation
Xia LINGHU ; Haitao RAN ; Danni LIU
Chinese Journal of Medical Imaging 2024;32(11):1195-1200
Atrial fibrillation is one of the most common arrhythmias and is associated with multiple adverse cardiovascular events.Imaging techniques such as echocardiography,MRI and CT can evaluate the structure and function of the left ventricle,which is of great significance for the selection of clinical treatment and the prediction of postoperative recurrence risk.This article reviews the progress of the above cardiac imaging techniques in left ventricular structure and function in atrial fibrillation.
3.Design and evaluation of a novel arcuate multi-channel rectal endoluminal applicator based on pelvic MRI images
Tian CHENG ; Qingjie LIAN ; Ran PENG ; Haitao SUN ; Ang QU ; Hao WANG
Chinese Journal of Radiation Oncology 2024;33(11):1042-1048
Objective:To design and evaluate a novel arcuate multi-channel rectal endoluminal applicator to enhance dose coverage of tumors in the upper and middle rectum and reduce pressure on the rectal wall.Methods:Pelvic MRI images of 200 Chinese cases without rectal lesions in the Peking University Third Hospital from July 2022 to August 2022 were retrospectively analyzed. Based on the image data, a rectal model with general characteristics of the population and two novel hard and soft rectal endoluminal applicators were designed and fabricated. The following properties of the conventional applicators and two new applicators were compared: deformation to the model rectal wall, maximum pressure, stable pressure, D 90%, D 100%, V 100%, V 150% and V 200% of the GTV, and D 2 cm3, D 1 cm3, and D 0.1 cm3 of the organs at risk (OAR). ANOVA or Kruskal-Wallis H-test was used to compare the differences among three applicators, and Dunnett's multiple comparison test was used for pairwise comparisons. Results:The novel hard and soft rectal endoluminal applicators caused less deformation of the model rectal wall. The maximum pressure on the rectal wall was (0.606 ± 0.182) kPa and (0.481 ± 0.229) kPa for the hard arcuate applicator and soft arcuate applicator, respectively, and the stable pressure was (0.207 ± 0.137) kPa and (0.055 ± 0.097) kPa, respectively, which were significantly smaller than those of the conventional applicator ( P <0.001, <0.001; P =0.024, <0.001), and the degree of reduction was at or near 50%. Under the premise of ensuring target dose, the D 2 cm3, D 1 cm3, and D 0.1 cm3 of OAR in the treatment plan designed with the novel applicator were significantly reduced compared to the cylindrical applicator (all P<0.001). Conclusion:The novel arcuate multi-channel rectal endoluminal applicator can significantly reduce rectal wall pressure and deformation, while also reducing the dose to OAR without compromising target dose coverage, offering certain therapeutic advantages.
4.Cryo-EM structures for the Mycobacterium tuberculosis iron-loaded siderophore transporter IrtAB.
Shan SUN ; Yan GAO ; Xiaolin YANG ; Xiuna YANG ; Tianyu HU ; Jingxi LIANG ; Zhiqi XIONG ; Yuting RAN ; Pengxuan REN ; Fang BAI ; Luke W GUDDAT ; Haitao YANG ; Zihe RAO ; Bing ZHANG
Protein & Cell 2023;14(6):448-458
The adenosine 5'-triphosphate (ATP)-binding cassette (ABC) transporter, IrtAB, plays a vital role in the replication and viability of Mycobacterium tuberculosis (Mtb), where its function is to import iron-loaded siderophores. Unusually, it adopts the canonical type IV exporter fold. Herein, we report the structure of unliganded Mtb IrtAB and its structure in complex with ATP, ADP, or ATP analogue (AMP-PNP) at resolutions ranging from 2.8 to 3.5 Å. The structure of IrtAB bound ATP-Mg2+ shows a "head-to-tail" dimer of nucleotide-binding domains (NBDs), a closed amphipathic cavity within the transmembrane domains (TMDs), and a metal ion liganded to three histidine residues of IrtA in the cavity. Cryo-electron microscopy (Cryo-EM) structures and ATP hydrolysis assays show that the NBD of IrtA has a higher affinity for nucleotides and increased ATPase activity compared with IrtB. Moreover, the metal ion located in the TM region of IrtA is critical for the stabilization of the conformation of IrtAB during the transport cycle. This study provides a structural basis to explain the ATP-driven conformational changes that occur in IrtAB.
Siderophores/metabolism*
;
Iron/metabolism*
;
Mycobacterium tuberculosis/metabolism*
;
Cryoelectron Microscopy
;
Adenosine Triphosphate/metabolism*
;
ATP-Binding Cassette Transporters
5. Dosimetric analysis of 3D-printing non-coplanar template combined with CT-guided125I seed implantation for the treatment of spinal metastasis
Jianing CUI ; Yuliang JIANG ; Zhe JI ; Fuxin GUO ; Ran PENG ; Haitao SUN ; Jinghong FAN ; Weiyan LI ; Junjie WANG
Chinese Journal of Radiation Oncology 2020;29(2):122-125
Objective:
To compare the preoperative and postoperative dosimetric parameters in the treatment of spinal metastasis, and to verify the accuracy of 3D-printing non-coplanar template (3D-PNCT) combined with CT-guided 125I seed implantation for the treatment of spinal metastasis.
Methods:
The treatment plans of 7 patients with spinal metastasis (9 lesions) from 2016 to 2018 receiving 3D-PNCT in combination with CT-guided 125I seed implantation were retrospectively analyzed. The dosimetric parameters including homogeneity index (HI), conformal index (CI), external index (EI), dose of 90% target volume(D90), mPD, volume percent of 100%, 150%, and 200% prescribed dose V100、V150、V200 and D2cm3 of spinal cord were compared before and after operation. The british columbia cancer ageny particle implantation quality evaluation standard was applied to evaluate the quality of implantation.
Results:
The HI, EI and CI, D90, mPD, V100, V150, V200 and D2cm3 of spinal cord did not significantly differ before and after the plan (all
6.Assessment of right ventricular function by two-dimensional speckle tracking echocardiography in heart failure patients with different left ventricular diastolic dysfunction grade
Xiuying LIU ; Yang SUN ; Haitao RAN ; Zhigang WANG
Chinese Journal of Ultrasonography 2020;29(7):564-570
Objective:To evaluate the right ventricular(RV) function by two-dimensional speckle tracking echocardiography(2D-STE) in heart failure patients with different left ventricle diastolic dysfunction grade.Methods:Twenty-nine healthy volunteers(control group), sixteen heart failure patients with reduced ejection fraction(HFrEF group) and eighty-six heart failure patients with preserved ejection fraction(HFpEF group) were enrolled in the Second Affiliated Hospital of Chongqing Medical University from October 2018 to September 2019. HFpEF patients were further divided into four subgroups according to recommendations of the American Society of Echocardiography in 2016: normal left ventricular diastolic function group and left ventricular diastolic dysfunction groups with grade 1, 2, 3 (LVDD1, LVDD2, LVDD3). Conventional ultrasonic parameters were obtained in apical four-chamber images, including RV basal diameter(RVD1), RV middle diameter(RVD2) and RV longitudinal diameter(RVD3), RV end diastolic area(EDA), end systolic area(ESA) and fractional area change(FAC), peak systolic velocity(S′), myocardial performance index(MPI), tricuspid annular plane systolic excursion(TAPSE). 2D-STE was performed to observe strain parameters, including basal, middle, apical and the whole longitudinal peak systolic strain of RV free wall respectively (RVLSbas, RVLSmid, RVLSapi and RVLSfw). Then 2D strain parameters were compared among these groups, and the correlation between 2D strain parameters and conventional ultrasonic parameters were analyzed.Results:①TAPSE and S′ gradually decreased in normal group, HFpEF group and HFrEF group(all P<0.05). For the four subgroups of HFpEF, compared to LVDD3, TAPSE、S′ increased significantly in normal group, LVDD1 and LVDD2(all P<0.05). ②RVLSbas, RVLSmid, RVLSfw gradually increased in control group, HFpEF group and HFrEF group(all P<0.05). The same trend appeared in group LVDD1, LVDD2 and LVDD3(all P<0.05). ③In control group, HFpEF group and HFrEF group, RVLSfw showed strong correlation with LVEF( r=0.77, P<0.01) and middle correlation with age, TAPSE, and S′( r=0.41, -0.48, -0.40, P<0.01). In the subgroups of HFpEF, RVLSfw had middle correlation with LV diastolic function( r=0.59, P<0.01), and weak correlation with age( r=0.21, P<0.01), and the same correlations with B-type natriuretic peptide(BNP), FAC, TAPSE( r=0.28, -0.29, -0.29; all P<0.01). Conclusions:2D-STE can detect the early subtle impairment of RV systolic function in HFpEF patients.
7.The application value of three‐dimensional echocardiographic automated quantification technique for assessing left heart chamber volumes and function
Hua TENG ; Jianli REN ; Haitao RAN ; Zheng FANG
Chinese Journal of Ultrasonography 2019;28(3):192-199
ObjectiveTo evaluate the accuracy and reproducibility of three‐dimensional echocardiographic( 3DE) automated quantification technique for assessment of left heart chamber volumes and function in consecutive patients . Methods One hundred and fifty consecutive patients underwent 3DE were enrolled in the cross‐sectional study . According to image quality , the patients were divided into satisfactory group ( n = 102 ) and unsatisfactory group ( n = 33 ) . T he accuracy and reproducibility of automated 3DE for measuring left ventricular end‐diastolic volume ( LVEDV ) , left ventricular end‐systolicvolume ( LVESV ) ,left atrial volume ( LAV ) and left ventricular ejection fraction ( LVEF ) were evaluated by the traditional manual 3DE as the relative standard . Among those with satisfactory image quality ,the effects of cardiac cycle selection on automatic 3DE were analyzed . In addition ,according to LVEDV index and LAV index ,the patients were grouped as enlargement group and normal group ,and the significance of editing the endocardial boundaries for both groups were analyzed . Results ① One hundred and thirty‐five patients were successfully analyzed by the automated 3DE . T he inter‐technique comparisons showed good correlations ( r‐values :LVEDV 0 .90 ,LVESV 0 .87 ,LAV 0 .86 ,LVEF 0 .67 ;all P < 0 .01 ) and small biases( LVEDV 11 .9 ml ,LVESV 6 .4 ml ,LAV 9 .0 ml ,LVEF -0 .4% ) for all measurements in all patients . ② T he various parameters in satisfactory group had better correlations and consistency than those in the unsatisfactory group( all P <0 .05) . ③Between the two different cardiac cycles ,the automated 3DE measurements showed good correlations( r‐values :EDV 0 .96 ,ESV 0 .96 ,LAV 0 .95 ,LVEF 0 .80 ;all P< 0 .01 ) . ④ After optimized boundary of the automated 3DE ,LVEDV ,LVESV increased and LVEF decreased in the left chamber enlargement group( all P <0 .05) . ⑤All automated measurements were more reproducible than conventional manual measurements in both intra‐/inter‐observer studies . Conclusions Since automated 3DE is accurate and reproducible for the assessment of left heart chamber volumes and function ,it can be widely used in clinical practice as a feasible and objective ultrasound technique .
8.Dosimetric analysis of 3D-printing template assisted and CT-guided 125I seed implantation for treatment of soft tissue sarcoma
Xuemin LI ; Ran PENG ; Yuliang JIANG ; Zhe JI ; Fuxin GUO ; Haitao SUN ; Jinghong FAN ; Xu LI ; Weiyan LI ; Junjie WANG
Chinese Journal of Radiological Medicine and Protection 2018;38(5):350-354
Objective To compare the dose distribution of postoperative plans with preoperative plans of 3D-printing template (coplanar and non-coplanar) assisted and CT-guided 125I seed implantation for the treatment of soft tissue sarcoma,and to explore the accuracy of treatment at dosimetry level.Methods From December 2015 to July 2017,19 patients with soft tissue sarcoma (a total of 25 lesions)were treated with 3D printing template assisted and CT-guided 125I seed implantation in Peking University Third Hospital.All patients underwent preoperative assessment,CT simulation orientation,preoperative planning,3D-template printing,3D-template reduction,needle and seed implantation,postoperative dosimetry assessment,postoperative care and follow-up.The preoperative and postoperative dosimetric parameters were conpared.Ten cases of soft tissue sarcoma in superficial trunk or limbs were screened.Preoperative planning of coplanar template and non-coplanar template were designed respectively.The dosimetric parameters of preoperative planning guided of two templates were compared.Results Twentyfive 3D-printing templates were designed and constructed,and 25 lesions were totalled.There was no statistical difference between preoperative and postoperative dosimetric parameters.There was no statistical difference of the preoperative plan's dosimetric parameters between coplanar and non-coplanar in soft tissue sarcoma of superficial trunk/limbs.Conclusions The validation of actual dose distribution in postoperative plans assisted by 3D-printing template in 125I seed implantation showed that most of parameters could meet the expectation of preoperative plans,which indicated the improvement in accuracy for this new modality.For soft tissue sarcoma located in the superficial trunk/limbs,it was recommended to select the 3D-printing coplanar template firstly.
9.Dosimetric study of 125I seed implantation by 3D-printing coplanar template for pelvic wall recurrent cervical cancer after radiotherapy
Ang QU ; Ran PENG ; Yuliang JIANG ; Ping JIANG ; Zhe JI ; Fuxin GUO ; Haitao SUN ; Jinghong FAN ; Weiyan LI ; Junjie WANG
Chinese Journal of Radiological Medicine and Protection 2018;38(10):756-760
Objective To investigate the feasibility of 3D-printing coplanar coordinate template (3D-PCT) for guiding 125I radioactive seed implantation in the treatment of pelvic wall recurrence of cervical cancer on ensuring the accuracy of dose.Methods From Oct 2016 to Dec 2017 in Peking University Third Hospital,totally 10 patients with pelvic wall recurrent cervical cancer after radiotherapy were treated with 125I radioactive seed implantation assisted by 3D-PCT.The median age was 53.5 years old (37-71 years old).KPS score of the cohort were more than 70.All patients had received pelvic radiation therapy previously.The median volume of the lesion was 31.9 cm3 (3.5-58.0 cm3).The prescription dose was 120-180 Gy.The activity of seeds was 0.55-0.67 mCi(1 Ci =3.7 × 1010Bq),while the number of seeds was 12-81 (median 50) on preoperative plan.Radioactive seeds implantation was performed under 3D-PCT guidance according to the preoperative plan.The actual number of implanted seeds was 53 (10-82).Dosimetry parameters of preoperative plan and postoperative plan including D90,D100,V100,V150,V200,external index (EI),conformal index (CI),heterogeneity index (HI),and organat-risk doses of D2 cm3,D1 cm3 and D0.1 cm3 were compared using the nonparametric test.Results The seed number of postoperative plan was more than that of preoperative plan (Z =-2.255,P < 0.05),but all of the dosimetric parameters showed no significant difference (P > 0.05).D2 cm3 and D1 cm3 of rectum for postoperative plan were lower than that of preoperative plan (Z =-2.100,-2.240,P < 0.05),while other dose parameters of normal tisssues showed no statistically significant difference (P > 0.05).Conclusions Assisted by 3D-PCT for 125I radioactive seed implantation in pelvic wall recurrence of cervical cancer,the actual postoperative dose could meet the requirement of the preoperatie plan through the intraoperative optimization of dose.3D-PCT could ensure the precise of delivered dose of 125I radioactive seed implantation.
10.Utilization rate of gold fiducial markers and reasons for abandonment in CyberKnife stereotactic body radiation therapy
Fei XU ; Fuxin GUO ; Ran PENG ; Xile ZHANG ; Hongqing ZHUANG ; Ping JIANG ; Jinghong FAN ; Weiyan LI ; Yuliang JIANG ; Zhe JI ; Haitao SUN ; Cheng CHENG ; Junjie WANG
Chinese Journal of Radiation Oncology 2018;27(3):295-298
Objective To investigate the utilization rate of gold fiducial markers and reasons for abandonment of gold fiducial markers in the CyberKnife VSI System, and to provide reference data for implantation of gold fiducial markers and radiotherapy planning. Methods From March to August,2017,a total of 47 patients had gold fiducial markers implanted or pasted. In those patients, 42 patients had gold fiducial markers implanted,including 32 receiving computed tomography(CT)-guided 3D-printing coplanar template assisted implantation, 1 receiving CT-guided 3D-printing non-coplanar template assisted implantation,1 receiving CT-guided implantation,and 8 receiving ultrasound-guided implantation. A total of 44 patients received the CyberKnife treatment, including 2 patients who failed to use gold fiducial markers and were treated with spine tracking instead and 3 patients missing the treatment for other reasons. The numbers of utilized and abandoned gold fiducial markers were recorded for calculation of the utilization and abandonment rates. The reasons for abandonment of gold fiducial markers were analyzed and classified. Results A total of 134 gold fiducial markers were implanted into or pasted to the 44 patients.In all the gold fiducial markers, 111 were utilized and 23 abandoned, yielding a utilization rate of 82.8% and an abandonment rate of 17.2%.The reasons for abandonment of gold fiducial markers included large rigidity error(26.1%), unqualified implanted fold fiducial markers(17.4%), displacement of gold fiducial markers(26.1%), and others(30.4%). Conclusions Compared with the CT-guided or ultrasound-guided implantation of gold fiducial markers, the CT-guided 3D-printing coplanar or non-coplanar template assisted implantation of gold fiducial markers requires only two puncture needles for each implantation and implants two gold fiducial markers by a single needle,which reduces the number of puncture needles,risk of puncture-induced injury,and incidence of complications after implantation. Not all the gold fiducial markers implanted by a variety of ways will be utilized. Some gold fiducial markers will be abandoned for different reasons,which should be taken into account during implantation of gold fiducial markers.

Result Analysis
Print
Save
E-mail