1.Characteristics of T cell immune responses in adults inoculated with 2 doses of SARS-CoV-2 inactivated vaccine for 12 months
Jing WANG ; Ya-Qun LI ; Hai-Yan WANG ; Yao-Ru SONG ; Jing LI ; Wen-Xin WANG ; Lin-Yu WAN ; Chun-Bao ZHOU ; Xing FAN ; Fu-Sheng WANG
Medical Journal of Chinese People's Liberation Army 2024;49(2):165-170
Objective To evaluate the characteristics of different antigen-specific T cell immune responses to severe acute respiratory syndrome coronavirus 2(SARS-CoV-2)after inoculation with 2 doses of SARS-CoV-2 inactivated vaccine for 12 months.Methods Fifteen healthy adults were enrolled in this study and blood samples collected at 12 months after receiving two doses of SARS-CoV-2 inactivated vaccine.The level and phenotypic characteristics of SARS-CoV-2 antigen-specific T lymphocytes were detected by activation-induced markers(AIM)based on polychromatic flow cytometry.Results After 12 months of inoculation with 2 doses of SARS-CoV-2 inactivated vaccine,more than 90%of adults had detectable Spike and Non-spike antigen-specific CD4+ T cells immune responses(Spike:14/15,P=0.0001;Non-spike:15/15,P<0.0001).80%of adults had detectable Spike and Non-spike antigen-specific CD8+ T cells immune responses(Spike:12/15,P=0.0463;Non-spike:12/15,P=0.0806).Antigen-specific CD4+ T cells induced by SARS-CoV-2 inactivated vaccination after 12 months were composed of predominantly central memory(CM)and effector memory 1(EM1)cells.On the other hand,in terms of helper subsets,antigen-specific CD4+ T cells mainly showed T helper 1/17(Th1/17)and T helper 2(Th2)phenotypes.Conclusions SARS-CoV-2 inactivated vaccination generates durable and extensive antigen-specific CD4+ T cell memory responses,which may be the key factor for the low proportion of severe coronavirus disease 2019(COVID-19)infection in China.
2.Reasons and strategies of reoperation after oblique lateral interbody fusion
Zhong-You ZENG ; Deng-Wei HE ; Wen-Fei NI ; Ping-Quan CHEN ; Wei YU ; Yong-Xing SONG ; Hong-Fei WU ; Shi-Yang FAN ; Guo-Hao SONG ; Hai-Feng WANG ; Fei PEI
China Journal of Orthopaedics and Traumatology 2024;37(8):756-764
Objective To summarize the reasons and management strategies of reoperation after oblique lateral interbody fusion(OLIF),and put forward preventive measures.Methods From October 2015 to December 2019,23 patients who under-went reoperation after OLIF in four spine surgery centers were retrospectively analyzed.There were 9 males and 14 females with an average age of(61.89±8.80)years old ranging from 44 to 81 years old.The index diagnosis was degenerative lumbar intervertebral dics diseases in 3 cases,discogenie low back pain in 1 case,degenerative lumbar spondylolisthesis in 6 cases,lumbar spinal stenosis in 9 cases and degenerative lumbar spinal kyphoscoliosis in 4 cases.Sixteen patients were primarily treated with Stand-alone OLIF procedures and 7 cases were primarily treated with OLIF combined with posterior pedicle screw fixation.There were 17 cases of single fusion segment,2 of 2 fusion segments,4 of 3 fusion segments.All the cases underwent reoperation within 3 months after the initial surgery.The strategies of reoperation included supplementary posterior pedicle screw instrumentation in 16 cases;posterior laminectomy,cage adjustment and neurolysis in 2 cases,arthroplasty and neuroly-sis under endoscope in 1 case,posterior laminectomy and neurolysis in 1 case,pedicle screw adjustment in 1 case,exploration and decompression under percutaneous endoscopic in 1 case,interbody fusion cage and pedicle screw revision in 1 case.Visu-al analogue scale(VAS)and Oswestry disability index(ODI)index were used to evaluate and compare the recovery of low back pain and lumbar function before reoperation and at the last follow-up.During the follow-up process,the phenomenon of fusion cage settlement or re-displacement,as well as the condition of intervertebral fusion,were observed.The changes in in-tervertebral space height before the first operation,after the first operation,before the second operation,3 to 5 days after the second operation,6 months after the second operation,and at the latest follow-up were measured and compared.Results There was no skin necrosis and infection.All patients were followed up from 12 to 48 months with an average of(28.1±7.3)months.Nerve root injury symptoms were relieved within 3 to 6 months.No cage transverse shifting and no dislodgement,loosening or breakage of the instrumentation was observed in any patient during the follow-up period.Though the intervertebral disc height was obviously increased at the first postoperative,there was a rapid loss in the early stage,and still partially lost after reopera-tion.The VAS for back pain recovered from(6.20±1.69)points preoperatively to(1.60±0.71)points postoperatively(P<0.05).The ODI recovered from(40.60±7.01)%preoperatively to(9.14±2.66)%postoperatively(P<0.05).Conclusion There is a risk of reoperation due to failure after OLIF surgery.The reasons for reoperation include preoperative bone loss or osteoporosis the initial surgery was performed by Stand-alone,intraoperative endplate injury,significant subsidence of the fusion cage after surgery,postoperative fusion cage displacement,nerve damage,etc.As long as it is discovered in a timely manner and handled properly,further surgery after OLIF surgery can achieve better clinical results,but prevention still needs to be strengthened.
3.Hyperoside nanoparticles loaded with bone marrow mesenchymal stem cells synergistically repair endometrial injury
Rui-Fang HAN ; Hai-Yi ZHOU ; Xing-Shan LIANG ; Si-Yi HE ; Yong-Ge GUAN ; Yang SONG
Chinese Pharmacological Bulletin 2024;40(7):1302-1311
Aim To evaluate the effect of hyperoside/chitosan-nanoparticles(Hyp-NPs)on bone marrow mesenchymal stem cells(BMSCs)in vitro cell experi-ments and the underlying mechanism,and to conduct in vivo animal experiments to investigate the synergistic effect of Hyp-NPs and BMSCs on repairing endometrial damage in rats.Methods BMSCs were identified by flow cytometry.Hyp-NPs were prepared by ion crosslinking method,characterized and evaluated by laser particle size analyzer and transmission electron microscopy.The effects of different concentrations of Hyp-NPs on the migration of BMSCs were evaluated by scratch assay and immunofluorescence.NRF2 lentivir-us vector was constructed to explore the mechanism of Hyp-NPs on BMSCs.In animal experiments,Hyp-NPs loaded with BMSCs were co-transplanted into the uter-ine cavity of a rat model of endometrial injury.HE,Masson,IHC,TUNEL,and ELISA experiments were used to systematically evaluate the repair effect and pregnancy function of the composite formulation on rat endometrial injury from multiple aspects and angles,including general pathology,fibrosis,receptivity,cell proliferation,angiogenesis,stem cell recruitment,and inflammation of the endometrium.Results BMSCs were successfully isolated and cultured.Hyp-NPs with high stability and small particle size were successfully prepared.Scratch experiments indicated that Hyp-NPs could promote the migration of BMSCs.By successfully constructing a lentiviral NRF2 vector and oxidative damage model for BMSCs,immunofluorescence experi-ments showed that Hyp-NPs could regulate the biologi-cal axis of BMSCs by activating NRF2.Animal experi-ments showed that the synergistic administration of Hyp-NPs and BMSCs could increase endometrial thick-ness and glandular quantity,promote stem cell homing through anti-fibrotic,anti-apoptotic,and anti-inflam-matory effects,and restore pregnancy function in rats with endometrial injury.Conclusion The synergistic administration of Hyp-NPs and BMSCs could repair en-dometrial injury.
4.Bilateral coronary artery-right ventricular fistula with rare huge tortuosity entering the same site:case report
Wei-Song TANG ; Rong-Li XU ; Xing-Jiu CAI ; Xiao-Li FANG ; Guan-Liang CHEN ; Hai-Rong LI
Chinese Journal of Interventional Cardiology 2024;32(4):236-240
Coronary artery fistula(CAF)is defined as the direct connection between coronary artery and cardiac cavity,great vessel or other vascular structures.Most CAF are congenital and often present as persistent murmur in asymptomatic children.Although abnormal shunt of most coronary fistulas has little effect on hemodynamics,some larger fistulas can also lead to a series of complications,such as congestive heart failure.Therefore,closed CAF has been recommended to treat or prevent myocardial ischemia,congestive heart failure,endarteritis,arrhythmia,thromboembolism,aneurysm dilatation and rupture and other complications.CAF is a rare congenital heart disease,and bilateral CAF originating from two coronary arteries is even rarer.At present,there are rare systematic reports on bilateral CAF.Therefore,a case of huge bilateral CAF at the same site was reported,and systematically,this kind of case was summarized,so as to improve the clinical attention of diagnosis and treatment of this kind of CAF.Nowadays,some new interventional devices and technologies are emerging with the continuous progress of cardiovascular interventional technology,making the treatment more accurate,safe and effective.At the same time,there is also a clearer understanding of the indications and operating standards for interventional treatment,which is more operable and predictable during the treatment process.Therefore,interventional treatment of CAF may partially replace surgical treatment as the preferred treatment method.
5.Sodium alginate coating simultaneously increases the biosafety and immunotherapeutic activity of the cationic mRNA nanovaccine.
Xing DUAN ; Yi ZHANG ; Mengran GUO ; Na FAN ; Kepan CHEN ; Shugang QIN ; Wen XIAO ; Qian ZHENG ; Hai HUANG ; Xiawei WEI ; Yuquan WEI ; Xiangrong SONG
Acta Pharmaceutica Sinica B 2023;13(3):942-954
The extraordinary advantages associated with mRNA vaccines, including their high efficiency, relatively low severity of side effects, and ease of manufacture, have enabled them to be a promising immunotherapy approach against various infectious diseases and cancers. Nevertheless, most mRNA delivery carriers have many disadvantages, such as high toxicity, poor biocompatibility, and low efficiency in vivo, which have hindered the widespread use of mRNA vaccines. To further characterize and solve these problems and develop a new type of safe and efficient mRNA delivery carrier, a negatively charged SA@DOTAP-mRNA nanovaccine was prepared in this study by coating DOTAP-mRNA with the natural anionic polymer sodium alginate (SA). Intriguingly, the transfection efficiency of SA@DOTAP-mRNA was significantly higher than that of DOTAP-mRNA, which was not due to the increase in cellular uptake but was associated with changes in the endocytosis pathway and the strong lysosome escape ability of SA@DOTAP-mRNA. In addition, we found that SA significantly increased the expression of LUC-mRNA in mice and achieved certain spleen targeting. Finally, we confirmed that SA@DOTAP-mRNA had a stronger antigen-presenting ability in E. G7-OVA tumor-bearing mice, dramatically inducing the proliferation of OVA-specific CLTs and ameliorating the antitumor effect. Therefore, we firmly believe that the coating strategy applied to cationic liposome/mRNA complexes is of potential research value in the field of mRNA delivery and has promising clinical application prospects.
6.Analysis of the causes and clinical results of vertebral fracture during oblique lateral lumbar interbody fusion.
Zhong-You ZENG ; Xing ZHAO ; Yu ZHANG ; Ping-Quan CHEN ; Wei YU ; Yong-Xing SONG ; Shun-Wu FAN ; Fei PEI ; Shi-Yang FAN ; Guo-Hao SONG ; Hai-Feng WANG
China Journal of Orthopaedics and Traumatology 2023;36(5):406-413
OBJECTIVE:
To analyze the causes of vertebral fracture during oblique lateral interbody fusion in the treatment of lumbar spondylopathy, summarize the clinical results, and propose preventive measures.
METHODS:
Retrospective analysis was made on the data of 8 cases of lumbar spondylopathy and vertebral fracture treated by oblique lateral interbody fusion in three medical centers from October 2014 to December 2018. All were female, aged from 50 to 81 years with an average of 66.4 years. Disease types included 1 case of lumbar degenerative disease, 3 cases of lumbar spinal stenosis, 2 cases of lumbar degenerative spondylolisthesis and 2 cases of lumbar degenerative scoliosis. Preoperative dual energy X-ray bone mineral density test showed that 2 cases had T-value >-1 SD, 2 cases had T-value -1 to -2.5 SD, and 4 cases had T-value <-2.5 SD. Single segment fusion was in 5 cases, two segment fusion in 1 case and three segment fusion in 2 cases. Four cases were treated with OLIF Stand-alone and 4 cases were treated with OLIF combined with posterior pedicle screw fixation. Postoperative imaging examination showed vertebral fracture, and all of them were single vertebral fracture. There were 2 cases of right lower edge fracture of upper vertebral body at fusion segment, 6 cases of lower vertebral body fracture at fusion segment, and 6 cases with endplate injury and fusion cage partially embedded in vertebral body. Three cases of OLIF Stand-alone were treated with pedicle screw fixation via posterior intermuscular approach, while one case of OLIF Stand-alone and four cases of OLIF combined with posterior pedicle screw fixation were not treated specially.
RESULTS:
The 5 cases of initial operation and 3 cases of reoperation did not show wound skin necrosis or wound infection. The follow-up time was from 12 to 48 months with an average of 22.8 months. Visual analogue scale (VAS) of low back pain was preoperative decreased from 4 to 8 points (averagely 6.3 points) and postoperative 1 to 3 points (averagely 1.7 points) at the final follow-up. Oswestry disability index (ODI) was preoperative 39.7% to 52.4% (averagely 40.2%), and postoperative 7.9% to 11.2% (averagely 9.5%) at the final follow-up. During the follow-up, there was no loosening or fracture of the pedicle screw system, and no lateral displacement of the fusion cage;however, the fusion cage at the vertebral fracture segment had obvious subsidence. The intervertebral space height of vertebral fracture segment was preoperaive 6.7 to 9.2 mm (averagely 8.1 mm), and postoperative 10.5 to 12.8 mm (averagely 11.2 mm). The improvement rate after operation was 37.98% compared to preoperative. The intervertebral space height at final follow-up was 8.4 to 10.9 mm (averagely 9.3 mm), and the loss rate was 16.71% compared with that after operation. At the final follow-up, interbody fusion was achieved in all cases except for one that could not be identified.
CONCLUSION
The incidence of vertebral fracture during oblique lateral interbody fusion in the treatment of lumbar spondylopathy is lower, and there are many reasons for fracture, including preoperative bone loss or osteoporosis, endplate injury, irregular shape of endplate, excessive selection of fusion cage, and osteophyte hyperplasia at the affected segment. As long as vertebral fracture is found in time and handled properly, the prognosis is well. However, it still needs to strengthen prevention.
Humans
;
Female
;
Male
;
Spinal Fractures/surgery*
;
Retrospective Studies
;
Treatment Outcome
;
Lumbar Vertebrae/surgery*
;
Spondylolisthesis/surgery*
;
Scoliosis
;
Spinal Fusion/methods*
7.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
8.Application value of CT examination of lymph node short diameter in evaluating cardia-left gastric lymph node metastasis in thoracic esophageal squamous cell carcinoma.
Zhen Xuan LI ; Xian Ben LIU ; Yin LI ; Guang Hui LIANG ; Zong Fei WANG ; Yan ZHENG ; Hai Bo SUN ; Wei WANG ; Tao SONG ; Wen Qun XING
Chinese Journal of Oncology 2023;45(11):962-966
Objective: To investigate the application value of computed tomography (CT) examination of lymph node short diameter in evaluating cardia-left gastric lymph node metastasis in thoracic esophageal squamous cell carcinoma (ESCC). Methods: A total of 477 patients with primary thoracic ESCC who underwent surgical treatment in the Affiliated Cancer Hospital of Zhengzhou University from January 2013 to December 2017 were collected. All of them underwent McKeown esophagectomy plus complete two-field or three-field lymph node dissection. Picture archiving and communication system were used to measure the largest cardia-left gastric lymph node short diameter in preoperative CT images. The postoperative pathological diagnosis results of cardia-left gastric lymph node were used as the gold standard. Receiver operating characteristic (ROC) curve was used to evaluate the efficacy of CT lymph node short diameter in detecting the metastasis of cardia-left gastric lymph node in thoracic ESCC, and determine the optimal cut-off value. Results: The median short diameter of the largest cardia-left gastric lymph node was 4.1 mm in 477 patients, and the largest cardia-left gastric lymph node short diameter was less than 3 mm in 155 cases (32.5%). Sixty-eight patients had cardia-left gastric lymph node metastases, of which 38 had paracardial node metastases and 41 had left gastric node metastases. The lymph node ratios of paracardial node and left gastric node were 4.0% (60/1 511) and 3.3% (62/1 887), respectively. ROC curve analysis showed that the area under the curve of CT lymph node short diameter for evaluating cardia-left gastric lymph node metastasis was 0.941 (95% CI: 0.904-0.977; P<0.05). The optimal cut-off value of CT examination of the cardia-left gastric lymph node short diameter was 6 mm, and the corresponding sensitivity, specificity and accuracy were 85.3%, 91.7%, and 90.8%, respectively. Conclusion: CT examination of lymph node short diameter can be a good evaluation of cardia-left gastric lymph node metastasis in thoracic ESCC, and the optimal cut-off value is 6 mm.
Humans
;
Esophageal Squamous Cell Carcinoma/pathology*
;
Cardia/surgery*
;
Esophageal Neoplasms/pathology*
;
Lymphatic Metastasis/pathology*
;
Lymph Nodes/pathology*
;
Lymph Node Excision
;
Tomography, X-Ray Computed/methods*
;
Esophagectomy/methods*
;
Retrospective Studies
9.Application value of CT examination of lymph node short diameter in evaluating cardia-left gastric lymph node metastasis in thoracic esophageal squamous cell carcinoma.
Zhen Xuan LI ; Xian Ben LIU ; Yin LI ; Guang Hui LIANG ; Zong Fei WANG ; Yan ZHENG ; Hai Bo SUN ; Wei WANG ; Tao SONG ; Wen Qun XING
Chinese Journal of Oncology 2023;45(11):962-966
Objective: To investigate the application value of computed tomography (CT) examination of lymph node short diameter in evaluating cardia-left gastric lymph node metastasis in thoracic esophageal squamous cell carcinoma (ESCC). Methods: A total of 477 patients with primary thoracic ESCC who underwent surgical treatment in the Affiliated Cancer Hospital of Zhengzhou University from January 2013 to December 2017 were collected. All of them underwent McKeown esophagectomy plus complete two-field or three-field lymph node dissection. Picture archiving and communication system were used to measure the largest cardia-left gastric lymph node short diameter in preoperative CT images. The postoperative pathological diagnosis results of cardia-left gastric lymph node were used as the gold standard. Receiver operating characteristic (ROC) curve was used to evaluate the efficacy of CT lymph node short diameter in detecting the metastasis of cardia-left gastric lymph node in thoracic ESCC, and determine the optimal cut-off value. Results: The median short diameter of the largest cardia-left gastric lymph node was 4.1 mm in 477 patients, and the largest cardia-left gastric lymph node short diameter was less than 3 mm in 155 cases (32.5%). Sixty-eight patients had cardia-left gastric lymph node metastases, of which 38 had paracardial node metastases and 41 had left gastric node metastases. The lymph node ratios of paracardial node and left gastric node were 4.0% (60/1 511) and 3.3% (62/1 887), respectively. ROC curve analysis showed that the area under the curve of CT lymph node short diameter for evaluating cardia-left gastric lymph node metastasis was 0.941 (95% CI: 0.904-0.977; P<0.05). The optimal cut-off value of CT examination of the cardia-left gastric lymph node short diameter was 6 mm, and the corresponding sensitivity, specificity and accuracy were 85.3%, 91.7%, and 90.8%, respectively. Conclusion: CT examination of lymph node short diameter can be a good evaluation of cardia-left gastric lymph node metastasis in thoracic ESCC, and the optimal cut-off value is 6 mm.
Humans
;
Esophageal Squamous Cell Carcinoma/pathology*
;
Cardia/surgery*
;
Esophageal Neoplasms/pathology*
;
Lymphatic Metastasis/pathology*
;
Lymph Nodes/pathology*
;
Lymph Node Excision
;
Tomography, X-Ray Computed/methods*
;
Esophagectomy/methods*
;
Retrospective Studies
10.CIC-rearranged sarcoma with rhabdoid features: a clinicopathological analysis.
Bei Jing PAN ; Qi Xing GONG ; Hai LI ; Shu Ying MA ; Guo Xin SONG ; Xiao LI ; Ying DING ; Qin He FAN ; Zhi Hong ZHANG
Chinese Journal of Pathology 2022;51(11):1141-1146
Objective: To investigate the histopathologic, immunohistochemical, molecular genetic characteristics of CIC-rearranged sarcoma (CRS) with rhabdoid features. Methods: The clinical and pathologic data of two cases of CRS diagnosed between 2019 and 2021 at the Department of Pathology, Jiangsu Province Hospital were analyzed. Immunohistochemical study and fluorescence in situ hybridization (FISH) were performed. The relevant literature was reviewed. Results: Both patients were female, one was 58 years old, with tumor located in left thigh; the other was 43 years old, with tumor located in left pelvic cavity. Microscopically, both tumors were composed of small to medium-sized round, oval cells, arranged in nodules or sheets. The tumor cells showed irregular nuclear outline, coarse chromatin with prominent nucleoli and brisk mitotic activity. Both cases showed rhabdoid phenotype with myxoid stromal changes. Immunohistochemically, both cases were positive for CD99 and c-myc. High WT1 reactivity was seen in classic area, with low reactivity in rhabdoid area. There was no INI1 lost in both cases. Both were negative for NKX2.2 and NKX3.1. By FISH both cases demonstrated convincing break-apart signals of CIC gene. One patient died of disease after 1 month, and the other died of disease after 3 months. Conclusions: CRS is a small round cell undifferentiated sarcoma of the bone and soft tissue defined by molecular genetic characteristics, and may show atypical morphologic and immunophenotypic characteristics such as rhabdoid features. A correct understanding of its rare morphologic and immunophenotypic characteristics, combined with molecular pathologic detection, is conducive to correct diagnosis.
Female
;
Humans
;
Male
;
Biomarkers, Tumor/analysis*
;
In Situ Hybridization, Fluorescence
;
Sarcoma/pathology*
;
Sarcoma, Small Cell/pathology*
;
Transcription Factors/genetics*
;
Rhabdoid Tumor/pathology*

Result Analysis
Print
Save
E-mail