1.Challenges and prospects of early intervention of elderly urinary incontinence in the context of China's aging population
Journal of Modern Urology 2025;30(4):275-278
		                        		
		                        			
		                        			In the context of China's aging population, the issue of urinary incontinence among the elderly is becoming increasingly severe.Urinary incontinence not only significantly impacts patients' quality of life, but also imposes a substantial economic burden and psychological stress.This article explores the challenges and prospects of the early intervention of elderly urinary incontinence in China, including improving early diagnosis rates, enhancing patients' self-management abilities, and early screening and prevention for high-risk groups.With the advancement of technology and medical innovations, digital self-management tools offer new possibilities for managing urinary incontinence, helping patients to better control their condition, especially when medical resources are limited.Furthermore, this article calls for greater attention from all sectors of the society to address elderly urinary incontinence and promote the implementation of more systematic research and management strategies to improve the quality of life for China's elderly population.
		                        		
		                        		
		                        		
		                        	
		                				2.Construction and characterization of lpxC  deletion strain based on CRISPR/Cas9 in Acinetobacter baumannii 
		                			
		                			Zong-ti SUN ; You-wen ZHANG ; Hai-bin LI ; Xiu-kun WANG ; Jie YU ; Jin-ru XIE ; Peng-bo PANG ; Xin-xin HU ; Tong-ying NIE ; Xi LU ; Jing PANG ; Lei HOU ; Xin-yi YANG ; Cong-ran LI ; Lang SUN ; Xue-fu YOU
Acta Pharmaceutica Sinica 2024;59(5):1286-1294
		                        		
		                        			
		                        			 Lipopolysaccharides (LPS) are major outer membrane components of Gram-negative bacteria. Unlike most Gram-negative bacteria,
		                        		
		                        	
3.Biomechanical Analysis of Hybrid Artificial Discs or Zero-Profile Devices for Treating 1-Level Adjacent Segment Degeneration in ACDF Revision Surgery
Weishi LIANG ; Yihan YANG ; Bo HAN ; Duan SUN ; Peng YIN ; Yong HAI
Neurospine 2024;21(2):606-619
		                        		
		                        			 Objective:
		                        			Cervical hybrid surgery optimizes the use of cervical disc arthroplasty (CDA) and zero-profile (ZOP) devices in anterior cervical discectomy and fusion (ACDF) but lacks uniform combination and biomechanical standards, especially in revision surgery (RS). This study aimed to investigate the biomechanical characteristics of adjacent segments of the different hybrid RS constructs in ACDF RS. 
		                        		
		                        			Methods:
		                        			An intact 3-dimensional finite element model generated a normal cervical spine (C2–T1). This model was modified to the primary C5–6 ACDF model. Three RS models were created to treat C4–5 adjacent segment degeneration through implanting cages plus plates (Cage-Cage), ZOP devices (ZOP-Cage), or Bryan discs (CDA-Cage). A 1.0-Nm moment was applied to the primary C5–6 ACDF model to generate total C2–T1 range of motions (ROMs). Subsequently, a displacement load was applied to all RS models to match the total C2–T1 ROMs of the primary ACDF model. 
		                        		
		                        			Results:
		                        			The ZOP-Cage model showed lower biomechanical responses including ROM, intradiscal pressure, maximum von Mises stress in discs, and facet joint force in adjacent segments compared to the Cage-Cage model. The CDA-Cage model exhibited the lowest biomechanical responses and ROM ratio at adjacent segments among all RS models, closely approached or lower than those in the primary ACDF model in most motion directions. Additionally, the maximum von Mises stress on the C3–4 and C6–7 discs increased in the Cage-Cage and ZOP-Cage models but decreased in the CDA-Cage model when compared to the primary ACDF model. 
		                        		
		                        			Conclusion
		                        			The CDA-Cage construct had the lowest biomechanical responses with minimal kinematic change of adjacent segments. ZOP-Cage is the next best choice, especially if CDA is not suitable. This study provides a biomechanical reference for clinical hybrid RS decision-making to reduce the risk of ASD recurrence. 
		                        		
		                        		
		                        		
		                        	
4.Biomechanical Analysis of Hybrid Artificial Discs or Zero-Profile Devices for Treating 1-Level Adjacent Segment Degeneration in ACDF Revision Surgery
Weishi LIANG ; Yihan YANG ; Bo HAN ; Duan SUN ; Peng YIN ; Yong HAI
Neurospine 2024;21(2):606-619
		                        		
		                        			 Objective:
		                        			Cervical hybrid surgery optimizes the use of cervical disc arthroplasty (CDA) and zero-profile (ZOP) devices in anterior cervical discectomy and fusion (ACDF) but lacks uniform combination and biomechanical standards, especially in revision surgery (RS). This study aimed to investigate the biomechanical characteristics of adjacent segments of the different hybrid RS constructs in ACDF RS. 
		                        		
		                        			Methods:
		                        			An intact 3-dimensional finite element model generated a normal cervical spine (C2–T1). This model was modified to the primary C5–6 ACDF model. Three RS models were created to treat C4–5 adjacent segment degeneration through implanting cages plus plates (Cage-Cage), ZOP devices (ZOP-Cage), or Bryan discs (CDA-Cage). A 1.0-Nm moment was applied to the primary C5–6 ACDF model to generate total C2–T1 range of motions (ROMs). Subsequently, a displacement load was applied to all RS models to match the total C2–T1 ROMs of the primary ACDF model. 
		                        		
		                        			Results:
		                        			The ZOP-Cage model showed lower biomechanical responses including ROM, intradiscal pressure, maximum von Mises stress in discs, and facet joint force in adjacent segments compared to the Cage-Cage model. The CDA-Cage model exhibited the lowest biomechanical responses and ROM ratio at adjacent segments among all RS models, closely approached or lower than those in the primary ACDF model in most motion directions. Additionally, the maximum von Mises stress on the C3–4 and C6–7 discs increased in the Cage-Cage and ZOP-Cage models but decreased in the CDA-Cage model when compared to the primary ACDF model. 
		                        		
		                        			Conclusion
		                        			The CDA-Cage construct had the lowest biomechanical responses with minimal kinematic change of adjacent segments. ZOP-Cage is the next best choice, especially if CDA is not suitable. This study provides a biomechanical reference for clinical hybrid RS decision-making to reduce the risk of ASD recurrence. 
		                        		
		                        		
		                        		
		                        	
5.Development of biological safety protection third-level laboratory based on folding-modular shelters
Si-Qing ZHAO ; Jian-Qiao XIA ; Zhong-Jie SUN ; Kang OUYANG ; Xiao-Jun JIN ; Kang-Li ZHOU ; Wei XIE ; Hai-Yang LI ; Da-Peng JIANG ; Yan-Yan GAO ; Bei SUN
Chinese Medical Equipment Journal 2024;45(3):41-46
		                        		
		                        			
		                        			Objective To develop a biological safety protection third-level(BSL-3)laboratory based on folding-modular shelters to solve the problems of the existing laboratories in space and function expansion,large-scale deployment and low-cost transportation.Methods The BSL-3 laboratory was composed of a folding combined shelter module,a ventilation and purification module,a power supply and distribution module,a monitoring and communication module,a control system module and an equipment module.The folding combined shelter module used a leveling base frame as the foundation and a lightweight panel as the enclosure mechanism,and was divided into an auxiliary area and a protection protected area;the ventilation and purification module was made up of an air supply unit and an air exhaust unit,the air supply unit was integrated with a fresh-air air conditioner and the exhaust unit was equipped with a main fan,a standby fan and a bag in/bag out filter;the control system module adopted a supervision mode of decentralized control and centralized management,which executed communication with the data server as the center and Profinet protocol and MODBUS-TCP.Results The BSL-3 laboratory proved to meet the requirements of relevant standards in internal microenvironment,airflow direction,airtightness,working condition and disinfection effect.Conclusion The BSL-3 laboratory is compatible with large-scale transport and deployment and facilitates reliable and safe experiments for epidemic prevention and control and cross-regional support.[Chinese Medical Equipment Journal,2024,45(3):41-46]
		                        		
		                        		
		                        		
		                        	
6.Research status of Wnt5a-Frizzled-2 pathway and ischemia-reperfusion injury
Zhi-Peng SUN ; Shu-Su DONG ; Chuan-Cheng MA ; Chen-Ying WANG ; Fei CHEN ; Hai-Ying WANG
The Chinese Journal of Clinical Pharmacology 2024;40(13):1972-1976
		                        		
		                        			
		                        			The Wnt signaling pathway includes both classical and non classical pathways,Wnt5a-Frizzled-2 pathway participates in the Wnt/Ca2+signaling pathway in the non-classical pathway,which is activated by the Wnt-related protein Wnt5a and its ligand Frizzled-2.It can regulate some key sites in cells to affect cell signal transduction,and is closely related to cell growth process.Activation of Wnt5a-Fizzled-2 pathway occurs in some tissues with abundant blood supply,such as heart and brain tissues,during ischemia-reperfusion.Activation of the Wnt5a-Frizzled-2 pathway causes these intracellular calcium overload,ultimately promoting apoptosis.This article reviews the abnormal activation of Wnt5a-Frizzled-2 signaling pathway in ischemia-reperfusion injury diseases and the induced calcium overload leading to apoptosis,in order to provide reference for the study of physiological mechanisms of ischemia-reperfusion injury.
		                        		
		                        		
		                        		
		                        	
7.Mechanisms of hypertension inducing erectile dysfunction via the cGMP/PKG signaling pathway:An investigation using transcriptomics and network pharmacology
Jun-Long FENG ; Hai-Song LI ; Song SUN ; Bin WANG ; Hua-Nan ZHANG ; Zi-Xiang GAO ; Peng-Ming MAO ; Long-Ji SUN ; Nian-Wen HUANG ; Ji-Sheng WANG
National Journal of Andrology 2024;30(9):771-781
		                        		
		                        			
		                        			Objective:To explore the mechanism of hypertension inducing erectile dysfunction(ED)using transcriptomics and network pharmacology.Methods:We randomly divided 12 male rats with spontaneous hypertension(SHT)into an L-arginine(LA)group(n=6)and an SHT model control(MC)group(n=6),took another 6 Wistar Kyoto male rats as normal controls(NC),and treated the animals in the LA group by intraperitoneal injection of LA at 400 mg/kg and those in the latter two groups with physio-logical saline,once a day,all for 7 days.Then we observed the blood pressure and penile erection of the rats,and determined the ex-pressions of the cGMP/PKG signaling pathway-related proteins and mRNAs in different groups using ELISA,Western blot and RT-qPCR.Results:Transcriptomics combined with network pharmacology showed that the cGMP/PKG signaling pathway played a key role in hypertension-induced ED.In vivo animal experiments revealed a significantly lower frequency of penile erections in the MC than in the NC group(1.33±0.52 vs 2.67±0.51,P<0.05).The protein expressions of eNOS,PKG and sGC were markedly de-creased in the model controls compared with those the normal controls(P<0.05),but remarkably upregulated in the LA group com-pared with those in the MC group(P<0.05).Conclusion:Hypertension decreases the expressions of eNOS,NO,sGC,cGMP and PKG proteins and the level of testosterone by inhibiting the cGMP/PKG signaling pathway,which consequently suppresses the relaxa-tion of the penile vascular smooth muscle and reduces erectile function.
		                        		
		                        		
		                        		
		                        	
8.Biomechanical Analysis of Hybrid Artificial Discs or Zero-Profile Devices for Treating 1-Level Adjacent Segment Degeneration in ACDF Revision Surgery
Weishi LIANG ; Yihan YANG ; Bo HAN ; Duan SUN ; Peng YIN ; Yong HAI
Neurospine 2024;21(2):606-619
		                        		
		                        			 Objective:
		                        			Cervical hybrid surgery optimizes the use of cervical disc arthroplasty (CDA) and zero-profile (ZOP) devices in anterior cervical discectomy and fusion (ACDF) but lacks uniform combination and biomechanical standards, especially in revision surgery (RS). This study aimed to investigate the biomechanical characteristics of adjacent segments of the different hybrid RS constructs in ACDF RS. 
		                        		
		                        			Methods:
		                        			An intact 3-dimensional finite element model generated a normal cervical spine (C2–T1). This model was modified to the primary C5–6 ACDF model. Three RS models were created to treat C4–5 adjacent segment degeneration through implanting cages plus plates (Cage-Cage), ZOP devices (ZOP-Cage), or Bryan discs (CDA-Cage). A 1.0-Nm moment was applied to the primary C5–6 ACDF model to generate total C2–T1 range of motions (ROMs). Subsequently, a displacement load was applied to all RS models to match the total C2–T1 ROMs of the primary ACDF model. 
		                        		
		                        			Results:
		                        			The ZOP-Cage model showed lower biomechanical responses including ROM, intradiscal pressure, maximum von Mises stress in discs, and facet joint force in adjacent segments compared to the Cage-Cage model. The CDA-Cage model exhibited the lowest biomechanical responses and ROM ratio at adjacent segments among all RS models, closely approached or lower than those in the primary ACDF model in most motion directions. Additionally, the maximum von Mises stress on the C3–4 and C6–7 discs increased in the Cage-Cage and ZOP-Cage models but decreased in the CDA-Cage model when compared to the primary ACDF model. 
		                        		
		                        			Conclusion
		                        			The CDA-Cage construct had the lowest biomechanical responses with minimal kinematic change of adjacent segments. ZOP-Cage is the next best choice, especially if CDA is not suitable. This study provides a biomechanical reference for clinical hybrid RS decision-making to reduce the risk of ASD recurrence. 
		                        		
		                        		
		                        		
		                        	
9.Biomechanical Analysis of Hybrid Artificial Discs or Zero-Profile Devices for Treating 1-Level Adjacent Segment Degeneration in ACDF Revision Surgery
Weishi LIANG ; Yihan YANG ; Bo HAN ; Duan SUN ; Peng YIN ; Yong HAI
Neurospine 2024;21(2):606-619
		                        		
		                        			 Objective:
		                        			Cervical hybrid surgery optimizes the use of cervical disc arthroplasty (CDA) and zero-profile (ZOP) devices in anterior cervical discectomy and fusion (ACDF) but lacks uniform combination and biomechanical standards, especially in revision surgery (RS). This study aimed to investigate the biomechanical characteristics of adjacent segments of the different hybrid RS constructs in ACDF RS. 
		                        		
		                        			Methods:
		                        			An intact 3-dimensional finite element model generated a normal cervical spine (C2–T1). This model was modified to the primary C5–6 ACDF model. Three RS models were created to treat C4–5 adjacent segment degeneration through implanting cages plus plates (Cage-Cage), ZOP devices (ZOP-Cage), or Bryan discs (CDA-Cage). A 1.0-Nm moment was applied to the primary C5–6 ACDF model to generate total C2–T1 range of motions (ROMs). Subsequently, a displacement load was applied to all RS models to match the total C2–T1 ROMs of the primary ACDF model. 
		                        		
		                        			Results:
		                        			The ZOP-Cage model showed lower biomechanical responses including ROM, intradiscal pressure, maximum von Mises stress in discs, and facet joint force in adjacent segments compared to the Cage-Cage model. The CDA-Cage model exhibited the lowest biomechanical responses and ROM ratio at adjacent segments among all RS models, closely approached or lower than those in the primary ACDF model in most motion directions. Additionally, the maximum von Mises stress on the C3–4 and C6–7 discs increased in the Cage-Cage and ZOP-Cage models but decreased in the CDA-Cage model when compared to the primary ACDF model. 
		                        		
		                        			Conclusion
		                        			The CDA-Cage construct had the lowest biomechanical responses with minimal kinematic change of adjacent segments. ZOP-Cage is the next best choice, especially if CDA is not suitable. This study provides a biomechanical reference for clinical hybrid RS decision-making to reduce the risk of ASD recurrence. 
		                        		
		                        		
		                        		
		                        	
10.Biomechanical Analysis of Hybrid Artificial Discs or Zero-Profile Devices for Treating 1-Level Adjacent Segment Degeneration in ACDF Revision Surgery
Weishi LIANG ; Yihan YANG ; Bo HAN ; Duan SUN ; Peng YIN ; Yong HAI
Neurospine 2024;21(2):606-619
		                        		
		                        			 Objective:
		                        			Cervical hybrid surgery optimizes the use of cervical disc arthroplasty (CDA) and zero-profile (ZOP) devices in anterior cervical discectomy and fusion (ACDF) but lacks uniform combination and biomechanical standards, especially in revision surgery (RS). This study aimed to investigate the biomechanical characteristics of adjacent segments of the different hybrid RS constructs in ACDF RS. 
		                        		
		                        			Methods:
		                        			An intact 3-dimensional finite element model generated a normal cervical spine (C2–T1). This model was modified to the primary C5–6 ACDF model. Three RS models were created to treat C4–5 adjacent segment degeneration through implanting cages plus plates (Cage-Cage), ZOP devices (ZOP-Cage), or Bryan discs (CDA-Cage). A 1.0-Nm moment was applied to the primary C5–6 ACDF model to generate total C2–T1 range of motions (ROMs). Subsequently, a displacement load was applied to all RS models to match the total C2–T1 ROMs of the primary ACDF model. 
		                        		
		                        			Results:
		                        			The ZOP-Cage model showed lower biomechanical responses including ROM, intradiscal pressure, maximum von Mises stress in discs, and facet joint force in adjacent segments compared to the Cage-Cage model. The CDA-Cage model exhibited the lowest biomechanical responses and ROM ratio at adjacent segments among all RS models, closely approached or lower than those in the primary ACDF model in most motion directions. Additionally, the maximum von Mises stress on the C3–4 and C6–7 discs increased in the Cage-Cage and ZOP-Cage models but decreased in the CDA-Cage model when compared to the primary ACDF model. 
		                        		
		                        			Conclusion
		                        			The CDA-Cage construct had the lowest biomechanical responses with minimal kinematic change of adjacent segments. ZOP-Cage is the next best choice, especially if CDA is not suitable. This study provides a biomechanical reference for clinical hybrid RS decision-making to reduce the risk of ASD recurrence. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail