1.Severity Assessment Parameters and Diagnostic Technologies of Obstructive Sleep Apnea
Zhuo-Zhi FU ; Ya-Cen WU ; Mei-Xi LI ; Ping-Ping YIN ; Hai-Jun LIN ; Fu ZHANG ; Yu-Xiang YANG
Progress in Biochemistry and Biophysics 2025;52(1):147-161
		                        		
		                        			
		                        			Obstructive sleep apnea (OSA) is an increasingly widespread sleep-breathing disordered disease, and is an independent risk factor for many high-risk chronic diseases such as hypertension, coronary heart disease, stroke, arrhythmias and diabetes, which is potentially fatal. The key to the prevention and treatment of OSA is early diagnosis and treatment, so the assessment and diagnostic technologies of OSA have become a research hotspot. This paper reviews the research progresses of severity assessment parameters and diagnostic technologies of OSA, and discusses their future development trends. In terms of severity assessment parameters of OSA, apnea hypopnea index (AHI), as the gold standard, together with the percentage of duration of apnea hypopnea (AH%), lowest oxygen saturation (LSpO2), heart rate variability (HRV), oxygen desaturation index (ODI) and the emerging biomarkers, constitute a multi-dimensional evaluation system. Specifically, the AHI, which measures the frequency of sleep respiratory events per hour, does not fully reflect the patients’ overall sleep quality or the extent of their daytime functional impairments. To address this limitation, the AH%, which measures the proportion of the entire sleep cycle affected by apneas and hypopneas, deepens our understanding of the impact on sleep quality. The LSpO2 plays a critical role in highlighting the potential severe hypoxic episodes during sleep, while the HRV offers a different perspective by analyzing the fluctuations in heart rate thereby revealing the activity of the autonomic nervous system. The ODI provides a direct and objective measure of patients’ nocturnal oxygenation stability by calculating the number of desaturation events per hour, and the biomarkers offers novel insights into the diagnosis and management of OSA, and fosters the development of more precise and tailored OSA therapeutic strategies. In terms of diagnostic techniques of OSA, the standardized questionnaire and Epworth sleepiness scale (ESS) is a simple and effective method for preliminary screening of OSA, and the polysomnography (PSG) which is based on recording multiple physiological signals stands for gold standard, but it has limitations of complex operations, high costs and inconvenience. As a convenient alternative, the home sleep apnea testing (HSAT) allows patients to monitor their sleep with simplified equipment in the comfort of their own homes, and the cardiopulmonary coupling (CPC) offers a minimal version that simply analyzes the electrocardiogram (ECG) signals. As an emerging diagnostic technology of OSA, machine learning (ML) and artificial intelligence (AI) adeptly pinpoint respiratory incidents and expose delicate physiological changes, thus casting new light on the diagnostic approach to OSA. In addition, imaging examination utilizes detailed visual representations of the airway’s structure and assists in recognizing structural abnormalities that may result in obstructed airways, while sound monitoring technology records and analyzes snoring and breathing sounds to detect the condition subtly, and thus further expands our medical diagnostic toolkit. As for the future development directions, it can be predicted that interdisciplinary integrated researches, the construction of personalized diagnosis and treatment models, and the popularization of high-tech in clinical applications will become the development trends in the field of OSA evaluation and diagnosis. 
		                        		
		                        		
		                        		
		                        	
2.Diagnostic Techniques and Risk Prediction for Cardiovascular-kidney-metabolic (CKM) Syndrome
Song HOU ; Lin-Shan ZHANG ; Xiu-Qin HONG ; Chi ZHANG ; Ying LIU ; Cai-Li ZHANG ; Yan ZHU ; Hai-Jun LIN ; Fu ZHANG ; Yu-Xiang YANG
Progress in Biochemistry and Biophysics 2025;52(10):2585-2601
		                        		
		                        			
		                        			Cardiovascular disease (CVD), chronic kidney disease (CKD), and metabolic disorders are the 3 major chronic diseases threatening human health, which are closely related and often coexist, significantly increasing the difficulty of disease management. In response, the American Heart Association (AHA) proposed a novel disease concept of “cardiovascular-kidney-metabolic (CKM) syndrome” in October 2023, which has triggered widespread concern about the co-treatment of heart and kidney diseases and the prevention and treatment of metabolic disorders around the world. This review posits that effectively managing CKM syndrome requires a new and multidimensional paradigm for diagnosis and risk prediction that integrates biological insights, advanced technology and social determinants of health (SDoH). We argue that the core pathological driver is a “metabolic toxic environment”, fueled by adipose tissue dysfunction and characterized by a vicious cycle of systemic inflammation and oxidative stress, which forms a common pathway to multi-organ injury. The at-risk population is defined not only by biological characteristics but also significantly impacted by adverse SDoH, which can elevate the risk of advanced CKM by a factor of 1.18 to 3.50, underscoring the critical need for equity in screening and care strategies. This review systematically charts the progression of diagnostic technologies. In diagnostics, we highlight a crucial shift from single-marker assessments to comprehensive multi-marker panels. The synergistic application of traditional biomarkers like NT-proBNP (reflecting cardiac stress) and UACR (indicating kidney damage) with emerging indicators such as systemic immune-inflammation index (SII) and Klotho protein facilitates a holistic evaluation of multi-organ health. Furthermore, this paper explores the pivotal role of non-invasive monitoring technologies in detecting subclinical disease. Techniques like multi-wavelength photoplethysmography (PPG) and impedance cardiography (ICG) provide a real-time window into microcirculatory and hemodynamic status, enabling the identification of early, often asymptomatic, functional abnormalities that precede overt organ failure. In imaging, progress is marked by a move towards precise, quantitative evaluation, exemplified by artificial intelligence-powered quantitative computed tomography (AI-QCT). By integrating AI-QCT with clinical risk factors, the predictive accuracy for cardiovascular events within 6 months significantly improves, with the area under the curve (AUC) increasing from 0.637 to 0.688, demonstrating its potential for reclassifying risk in CKM stage 3. In the domain of risk prediction, we trace the evolution from traditional statistical tools to next-generation models. The new PREVENT equation represents a major advancement by incorporating key kidney function markers (eGFR, UACR), which can enhance the detection rate of CKD in primary care by 20%-30%. However, we contend that the future lies in dynamic, machine learning-based models. Algorithms such as XGBoost have achieved an AUC of 0.82 for predicting 365-day cardiovascular events, while deep learning models like KFDeep have demonstrated exceptional performance in predicting kidney failure risk with an AUC of 0.946. Unlike static calculators, these AI-driven tools can process complex, multimodal data and continuously update risk profiles, paving the way for truly personalized and proactive medicine. In conclusion, this review advocates for a paradigm shift toward a holistic and technologically advanced framework for CKM management. Future efforts must focus on the deep integration of multimodal data, the development of novel AI-driven biomarkers, the implementation of refined SDoH-informed interventions, and the promotion of interdisciplinary collaboration to construct an efficient, equitable, and effective system for CKM screening and intervention. 
		                        		
		                        		
		                        		
		                        	
3.Prognostic factor and its predictive value of patients with Wilson's disease-related acute-on-chronic liver failure
Lu-Lu TANG ; Huai-Zhen CHEN ; Jing ZHANG ; Ting DONG ; Jun LI ; Hai-Lin JIANG ; Wen-Ming YANG
Medical Journal of Chinese People's Liberation Army 2024;49(2):131-136
		                        		
		                        			
		                        			Objective To explore the prognostic factor and its predictive value of patients with Wilson disease-related acute-on-chronic liver failure(WD-ACLF).Methods The clinical data of 70 patients diagnosed as WD-ACLF admitted to the Department of Encephalopathy of the First Affiliated Hospital of Anhui University of Chinese Medicine from January 1,2017 to January 1,2022 were retrospectively collected.According to the 12-week prognosis,patients were divided into survival group(n=36)and death group(n=34).The data of the two groups were analyzed by univariate and multivariate logistic analysis to screen the prognostic risk factors and evaluate their predictive value.The model coefficient is omnibus tested,and the model-fitting degree is evaluated by the Hosmer-Lemeshow test.ROC curve was used to analyze the prognostic value for WD-ACLF between the new model and chronic liver failure-sequential organ failure assessment(CLIF-SOFA)score,model for end-stage liver disease(MELD)score and Child-Turcotte-Pugh(CTP)score.Results A total of 70 WD-ACLF patients were enrolled in present study,including 36 cases in survival group[22 males and 14 females with median age of 30.0(17.3,40.0)]and 34 cases in death group[25 males and 9 females with median age of 34.0(28.8,41.0)].Univariate analysis showed that the course of disease,prothrombin time(PT),activated partial thromboplastin time(APTT)were shorter in survival group than that in death group,the white blood cells(WBC),international normalized ratio(INR),aspartate transaminase(AST),total bilirubin(TBIL),blood urea nitrogen(BUN),creatinine(Cre)and ceruloplasmin(CER)levels and the proportion of infection,ascites,and upper gastrointestinal bleeding were lower in survival group than those in death group,however,the proportion of infection,ascites and upper digestive bleeding in the survival group were lower than those in the death group.Meanwhile,the red blood cells(RBC),hemoglobin(Hb),Na+ and total cholesterol(TC)level in the survival group were higher than those in the death group(P<0.05 or P<0.01).The results of multivariate logistic regression analysis showed that disease course(OR=1.176,95%CI 1.043-1.325),INR(OR=7.635,95%CI 1.767-32.980),TBIL(OR=1.012,95%CI 1.003-1.021),and upper gastrointestinal bleeding(OR=11.654,95%CI 1.029-131.980)were independent risk factors affecting the prognosis of WD-ACLF(P<0.05).Based on the results of logistic regression analysis,a joint model for predicting the prognosis of WD-ACLF was established.The AUC of the model for evaluating the prognosis of WD-ACLF was 0.941,which was greater than the CLIF-SOFA score(AUC=0.802),MELD score(AUC=0.897),and CTP score(AUC=0.722).Conclusions The course of disease,TBIL,INR,and upper gastrointestinal bleeding are risk factors that affect the prognosis of WD-ACLF.The prognosis model established based on this can more accurately predict the prognosis of WD-ACLF patients,and its predictive value is superior to CLIF-SOFA score,MELD score,and CTP score.
		                        		
		                        		
		                        		
		                        	
4.Status of wearable flexible monitoring devices based on organic field effect transistors in biomedical field
Kai GUO ; Cui-Zhi TANG ; Bo SUN ; Duan-Qiang XIAO ; Yuan-Biao LIU ; En-Xiang JIAO ; Jie GONG ; Hai-Jun ZHANG
Chinese Medical Equipment Journal 2024;45(1):93-100
		                        		
		                        			
		                        			The working principle and development of flexible semiconductor devices based on organic field effect transistor(OFET)technology were introduced.The current research status of OFET-based wearable flexible monitoring devices were reviewed,including biomechanical monitoring devices,tattoo biomonitoring devices and cellular detection devices and etc.The deficiencies of OFET-based wearable flexible monitoring devices were analyzed,and it's pointed out that miniaturization,personalization and diversification were the directions for the development of the future OFET-based wearable flexible moni-toring devices.[Chinese Medical Equipment Journal,2024,45(1):93-100]
		                        		
		                        		
		                        		
		                        	
5.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
		                        		
		                        			
		                        			Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.
		                        		
		                        		
		                        		
		                        	
6.Analysis of the efficacy of lumbar cistern drainage in the treatment of paraplegia after endovascular repair of acute aortic dissection
Yidong HUANG ; Zhiwen ZHANG ; Wenrui LI ; Lei JIN ; Hai FENG ; Jun ZHANG
International Journal of Surgery 2024;51(7):466-470
		                        		
		                        			
		                        			Objective:To evaluate the efficacy of lumbar cisterna drainage(LCD) in treating paraplegia after thoracic endovascular aortic repair(TEVAR) for acute aortic dissection.Methods:A retrospective descriptive study was used to analyze 4 patients with aortic dissection who developed paraplegia after transthoracic aortic stent graft repair (TEVAR) admitted to Beijing Friendship Hospital Affiliated to Capital Medical University from May 2015 to May 2022. There were 3 males and 1 females, aged between 38 and 65 years old. All patients with paraplegia after TEVAR were treated with LCD. Follow-up was carried out by outpatient and telephone for 12 months. The imaging indicators and clinical efficacy were observed.Results:Two patients were fully recovered before discharge, one patient was completely recovered by about 3 months after surgery, and one patient still had reduced sensation and grade 4 muscle strength at 12 months of follow-up. The CT angiography of all 4 patients did not show any evidence of endoleak, and there was no enlargement of the distal dissecting aneurysm.Conclusion:Lumbar cisterna drainage can alleviate or cure paraplegia caused by spinal cord ischemia after TEVAR for acute aortic dissection.
		                        		
		                        		
		                        		
		                        	
7.Comparison of the efficacy of TiRobot orthopaedic robot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures
Xing-Long ZHAO ; Jian-Jun SHEN ; Kang-Hu FENG ; Zhi-Wei CHEN ; Yuan-Long SI ; Xuan ZHANG ; Guan-De WANG ; Xiang HAI
China Journal of Orthopaedics and Traumatology 2024;37(2):129-134
		                        		
		                        			
		                        			Objective To compare the effectiveness of TiRobot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures.Methods A retrospective analysis was conducted on 72 patients with unstable femoral neck fractures who were treated with percutaneous cannulated screw fixation assisted with TiRobot Orthopaedic robot from December 2019 to April 2021.Among them,37 patients were treated with F screw internal fixa-tion,including 16 males and 21 females,aged47 to 64years old with an average of(53.87±5.28)years old;According to Pauwels classification,there were 1 case of type Ⅰ,19 cases of type Ⅱ,17 cases of type Ⅲ;8 cases of combined medical diseases;17 cases of falling,8 cases of traffic accident and 12 cases of falling from height;The time from injury to operation was 29 to 49 hours with average of(35.00±7.34)hours.Another 35 cases used internal fixation with an inverted triangle parallel nail,including 13 males and 22 females with an average age of 46 to 63 years old(52.36±5.05)years old;According to the Pauwels injury classifi-cation:there were 2 cases of type Ⅰ,21 cases of type Ⅱ,12 cases of type Ⅲ;6 cases of medical diseases,15 cases of falling in-jury,9 cases of traffic accident,11 cases of falling injury;The time from injury to operation was 30 to 45 hours with an average of(33.00±6.83)h.The intraoperative blood loss,operation time,intraoperative fluoroscopy times,follow-up time,fracture healing time,postoperative complications were observed and compared between the two groups.The hip joint function was e-valuated by Harris score at 6 months and 12 months after operation.Results There was no significant difference in operation time,intraoperative blood loss,intraoperative fluoroscopy times and other intraoperative data between two groups(P>0.05).Both groups were followed up regularly,and the follow-up time was 12 to 16 months.The fracture healing time and Harris score of the F screw internal fixation group were better than those of the inverted triangle parallel nail internal fixation group(P<0.05).There was 1 case of femoral neck shortening in the F screw internal fixation group,1 case of nonunion,1 case of nail withdrawal,and 1 case of lower extremity deep vein thrombosis in the inverted triangle internal fixation group.The incidence of complications in the F screw internal fixation group was lower than that in the inverted triangle parallel nail internal fixation group(P<0.05).Conclusion Percutaneous cannulated F screw technique using Tirobot navigation positioning system is a safe and effective treatment for patients with unstable femoral neck fractures.It can significantly shorten the fracture healing time,reduce the incidence of postoperative complications,significantly improve hip joint function,and improve the quality of life.
		                        		
		                        		
		                        		
		                        	
8.Comparison of the posterior hemipelvectomy of the greater trochanter approach with the standard Kocher-Langen-beck approach in the treatment of posterior acetabulum wall fractures
Jin ZHANG ; Jian-Jun SHEN ; Xiang HAI ; Chuan-Yuan LIU ; Wen-Jie ZHOU ; Zhi-Wei CHEN
China Journal of Orthopaedics and Traumatology 2024;37(8):786-792
		                        		
		                        			
		                        			Objective To compare the clinical efficacy of the posterior hemipelvectomy of the greater trochanter approach with the standard Kocher-Langenbeck(K-L)approach in the treatment of posterior acetabulum wall fractures and to explore a more optimal approach for the treatment of posterior acetabulum wall fractures.Methods Total of 26 patients with posterior ac-etabulum wall fractures were retrospectively analysed and divided into two groups:the posterior hemipelvectomy of the greater trochanter group(test group)and the standard K-L approach group(control group).In the test group,there were 24 patients including 16 males and 8 females with an average age of(42.00±4.52)years old,the time of injury to surgery was(6.75±1.15)d.In the control group,there were 23 patients including 16 males and 7 females with an average age of(41.00±5.82)years old,the time of injury to surgery was(7.09±1.20)days.The total hospital stay,length of incision,operation time,intraoperative bleeding,postoperative drainage,discharge,fracture reduction quality(Matta criteria),hip abduction muscle strength,hip func-tion(Merle d'Aubigne-Postel score),postoperative complications and the incidence of ectopic ossification were compared.Results All cases were followed up for 6 months.There was no significant difference in incision length,intraoperative bleeding and postoperative drainage between two groups(P>0.05).However,the operation time of the test group was shorter than that of the control group(P<0.05).There was no statistically significant difference in fracture reduction and hip function between two groups(P>0.05).The hip abduction muscle strength of test group was better than that of control group(P<0.05).In addition,there was no significant difference in the incidence of postoperative complications and heterotopic ossification between two groups(P>0.05).Conclusion Compared with the standard K-L approach,the posterior hemipelvectomy of the greater trochanter approach can shorten the operative time,has better recovery of the postoperative hip abduction muscle strength,ex-poses the view of the fracture involving the more comminuted posterior acetabulum wall or the fracture of the roof of the socket,improved the rate of fracture anatomical repositioning,provides a new idea for the clinical treatment of posterior acetabulum wall fractures,and allows patients to perform functional exercises at an early stage.
		                        		
		                        		
		                        		
		                        	
9.Predictive value of balanced steady-state free precession MRI combined with IVIM-DWI and Gd-DTPA enhancement for extramural vascular status in rectal cancer
Jun ZHANG ; Hai-Qing ZHANG ; Yan-Jun LIU ; Peng XIA ; Bing YU ; Hui-Jie ZHA
Chinese Journal of Current Advances in General Surgery 2024;27(5):369-372
		                        		
		                        			
		                        			Objective:To investigate the predictive value of MRI balanced steady-state free precession(b SSFP)synergistic voxel incoherent motion diffusion weighted imaging(IVIM-DWI)and Gd-DTPA enhanced scanning for the status of extramural vascular invasion(EMVI)in rectal cancer before surgery.Methods:A total of 105 rectal cancer patients from the People's Hospital of Lujiang County,Anhui Province,were retrospectively selected and included.All patients were confirmed by postoperative pathology and underwent preoperative b SSFP sequences,IVIM-DWI functional imaging,and Gd-DTPA-enhanced multiparameter MRI scans.Three seven-point schemes based on individual b SSFP sequences,IVIM-DWI functional imaging,and Gd-DTPA en-hancement,two-by-two synergy,and multi-sequence combined diagnosis were utilized in con-junction with conventional MRI sequences for preoperative prediction of EMVI status.The diag-nostic efficacy of T2WI and b SSFP sequences was compared with that of postoperative patho-logic results.ROC curves were plotted to obtain the corresponding area under the ROC curve(AUC),specificity,and sensitivity.Results:The AUC for predicting the preoperative vascular status outside the rectal wall was 0.572(95%CI:0.408~0.737)for the conventional T2 lipid sup-pression sequence,with a specificity of 0.811 and a sensitivity of 0.667.The AUC for the b SSPF sequence was 0.817(95%CI:0.680~0.954),with a specificity of 0.900 and a sensitivity of 0.733.All of the statistical parameters were higher than the diagnostic efficacy of conventional T2 lipid suppression sequences.The multi-sequence MRI co-diagnosis had an AUC of 0.961(95%CI:0.886~1.000),with a specificity of 0.988 and a sensitivity of 0.875(P<0.05).Conclusion:Mag-netic resonance b SSFP sequence synergized with IVIM-DWI and Gd-DTPA-enhanced multipa-rameter scanning has high clinical application value for the preoperative prediction of EMVI inva-sion in rectal cancer.
		                        		
		                        		
		                        		
		                        	
10.Analysis on comprehensive noise control effects in an automobile engine manufacturing enterprise
Lin CHEN ; Youmei SHU ; Yang LIAO ; Hai ZHANG ; Kunpeng ZHONG ; Jun LIU ; Fengyi OU ; Zhi WANG
China Occupational Medicine 2024;51(2):168-171
		                        		
		                        			
		                        			ObjectiveTo analyze the measures and effects of comprehensive noise control in an automobile engine manufacturing enterprise. Methods An automobile engine manufacturing enterprise with noise exposure work-sites was selected as the research subject. The noise hazard status of the enterprise was investigated. The noise hazard exceeded the national standard in work-sites was comprehensively treated. The treatment effect was analyzed. Results A total of 395 work-sites exposed to noise were detected. Among them, 16 work-sites exceeded the national noise standard, with the rate of 4.1%. The work-sites with noise exceeding the national standard were mainly in the machine workshop and the casting workshop, with normalization of equivalent continuous A-weighted sound pressure level to a nominal eight hours working day (LEX,8h) ranging from 86.8 to 89.2 and 85.2 to 90.2 dB(A), respectively. In addition, the classification of occupational noise exposure of the mold protection group in the casting workshop was level Ⅱ, and classification of occupational noise exposure of other work-sites with excessive national standard was grade Ⅰ. After the enterprise implemented noise control measures such as process reform, equipment replacement, sound insulation, noise reduction, sound absorption, and vibration isolation, the LEX,8h of nine positions were lower than those before rectification [(86.7±1.1) vs (83.3±1.3) dB(A), P<0.01]. Conclusion The use of comprehensive control measures can achieve the purpose of reducing noise from the sources, and can be used for reference by relevant enterprises with noise hazards. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail