1.Analysis of phenotype formation mechanism of a new variety of Lonicera japonica Flos "Huajin 6" at long bud stage
Run-zhu LI ; Cong-lian LIANG ; Zhen-hua LIU ; Jia LI ; Yong-qing ZHANG ; Hai-yan LIU ; Gao-bin PU
Acta Pharmaceutica Sinica 2024;59(2):476-481
Based on the long bud stage phenotype of a new
2.Optimization and application of an automatic monitoring module for drug-induced arrhythmias based on population characteristics
Peng LI ; Dai-Hong GUO ; Man ZHU ; Ao GAO ; Hai-Li GUO ; An FU ; An-Qi ZHAO ; Ting-Yong SHI
The Chinese Journal of Clinical Pharmacology 2024;40(9):1345-1349
Objective To develop the functions and optimize the automatic monitoring module for arrhythmias of the adverse drug event active surveillance and assessment system-Ⅱ,in order to continuously improve the performance,enhance the monitoring efficiency,and explore the ways to optimize the module.Methods Expand and optimize the functions of the module,increase the customized configuration,and determine the optimal setting conditions;compare the optimized test data with the results of the evaluation studies on the automatic monitoring of drug-induced arrhythmias in large samples of medicated population previously,and verify the optimization extent as well as the accuracy of the module.Results In the new module optimized according to the characteristics of the monitoring population,the function of"mandatory medical order keywords"was added,and it was determined that the inclusion of 6 electrocardiogram examination-related medical order keywords with a frequency of not less than 2 occurrences was the optimal configuration condition for the optimization of the module;combining the results of the previous automatic monitoring and evaluation researches,the system functions were verified and compared under the conditions of using the whole drugs and 2 kinds of single drug.While there was no loss of true positive cases,the number of cases with system alarms decreased by 30.75%,80.13%and 90.82%,respectively,compared with that before the optimization of the module,and the positive predictive value was significantly improved.Conclusion After the function expansion and optimization,the automatic monitoring module of drug-induced arrhythmias significantly reduces the labor cost of case evaluation and keeps the accuracy of monitoring results constant;the new module can better adapt to the demands of different automatic monitoring modes and operates stably,which is more generalizable and flexible,and provides a new way of considering for the research and development of automatic monitoring modules.
3.Bioequivalence study of olmesartan medoxomil tablet in Chinese healthy subjects
Na SHAN ; Da-Hai JIANG ; Lin-Lin MIAO ; Zhen-Li REN ; Peng-Bo JIN ; Pei-Qi HAO ; Li AN ; Hong ZHU ; Yong XIN ; Guang-De YANG ; Feng LIU
The Chinese Journal of Clinical Pharmacology 2024;40(20):3033-3037
Objective To study the bioequivalence of test and reference olmesartan tablet in Chinese healthy subjects after single dose under fasting and fed conditions.Methods A single-center,random,open,single-dose,two-preparations,double-period,crossover study was adopted.A total of 48 healthy adult male and female subjects(24 cases of fasting test and 24 cases of fed test)were included in the random crossover administration.Single oral dose 20 mg of test and reference were taken under fasting and postprandial conditions,respectively.Plasma concentration of olmesartan in plasma were determined by liquid chromatography tandem mass spectrometry.The main pharmacokinetic parameters were calculated by Phoenix WinNonlin 8.0 software.Results The main pharmacokinetic parameters of the test and reference preparations of olmesartan tablets in the fasting group were as follows:Cmax were(653.06±133.53)and(617.37±151.16)ng·mL-1,AUC0-t were(4 201.18±1 035.21)and(4 087.38±889.99)ng·mL-1·h,AUC0-∞ were(4 254.30±1 058.90)and(4 135.69±905.29)ng·mL-1·h.The main pharmacokinetic parameters of the test and reference preparations of olmesartan tablets in the postprandial group were as follows:Cmax were(574.78±177.05)and(579.98±107.74)ng·mL-1,AUC0-t were(3 288.37±866.06)and(3 181.51±801.06)ng·mL-1·h,AUC0-∞ were(3 326.11±874.26)and(3 242.01±823.09)ng·mL-1·h.Under fasting and postprandial conditions,the 90%confidence intervals of the main pharmacokinetic parameters of the test and reference preparations are both 80.00%-125.00%.Conclusion Under fasting and postprandial conditions,a single oral dose of test and reference preparations olmesartan tablets in Chinese healthy adult volunteers showed bioequivalence.
4.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.
5.A multi-center epidemiological study on pneumococcal meningitis in children from 2019 to 2020
Cai-Yun WANG ; Hong-Mei XU ; Gang LIU ; Jing LIU ; Hui YU ; Bi-Quan CHEN ; Guo ZHENG ; Min SHU ; Li-Jun DU ; Zhi-Wei XU ; Li-Su HUANG ; Hai-Bo LI ; Dong WANG ; Song-Ting BAI ; Qing-Wen SHAN ; Chun-Hui ZHU ; Jian-Mei TIAN ; Jian-Hua HAO ; Ai-Wei LIN ; Dao-Jiong LIN ; Jin-Zhun WU ; Xin-Hua ZHANG ; Qing CAO ; Zhong-Bin TAO ; Yuan CHEN ; Guo-Long ZHU ; Ping XUE ; Zheng-Zhen TANG ; Xue-Wen SU ; Zheng-Hai QU ; Shi-Yong ZHAO ; Lin PANG ; Hui-Ling DENG ; Sai-Nan SHU ; Ying-Hu CHEN
Chinese Journal of Contemporary Pediatrics 2024;26(2):131-138
Objective To investigate the clinical characteristics and prognosis of pneumococcal meningitis(PM),and drug sensitivity of Streptococcus pneumoniae(SP)isolates in Chinese children.Methods A retrospective analysis was conducted on clinical information,laboratory data,and microbiological data of 160 hospitalized children under 15 years old with PM from January 2019 to December 2020 in 33 tertiary hospitals across the country.Results Among the 160 children with PM,there were 103 males and 57 females.The age ranged from 15 days to 15 years,with 109 cases(68.1% )aged 3 months to under 3 years.SP strains were isolated from 95 cases(59.4% )in cerebrospinal fluid cultures and from 57 cases(35.6% )in blood cultures.The positive rates of SP detection by cerebrospinal fluid metagenomic next-generation sequencing and cerebrospinal fluid SP antigen testing were 40% (35/87)and 27% (21/78),respectively.Fifty-five cases(34.4% )had one or more risk factors for purulent meningitis,113 cases(70.6% )had one or more extra-cranial infectious foci,and 18 cases(11.3% )had underlying diseases.The most common clinical symptoms were fever(147 cases,91.9% ),followed by lethargy(98 cases,61.3% )and vomiting(61 cases,38.1% ).Sixty-nine cases(43.1% )experienced intracranial complications during hospitalization,with subdural effusion and/or empyema being the most common complication[43 cases(26.9% )],followed by hydrocephalus in 24 cases(15.0% ),brain abscess in 23 cases(14.4% ),and cerebral hemorrhage in 8 cases(5.0% ).Subdural effusion and/or empyema and hydrocephalus mainly occurred in children under 1 year old,with rates of 91% (39/43)and 83% (20/24),respectively.SP strains exhibited complete sensitivity to vancomycin(100% ,75/75),linezolid(100% ,56/56),and meropenem(100% ,6/6).High sensitivity rates were also observed for levofloxacin(81% ,22/27),moxifloxacin(82% ,14/17),rifampicin(96% ,25/26),and chloramphenicol(91% ,21/23).However,low sensitivity rates were found for penicillin(16% ,11/68)and clindamycin(6% ,1/17),and SP strains were completely resistant to erythromycin(100% ,31/31).The rates of discharge with cure and improvement were 22.5% (36/160)and 66.2% (106/160),respectively,while 18 cases(11.3% )had adverse outcomes.Conclusions Pediatric PM is more common in children aged 3 months to under 3 years.Intracranial complications are more frequently observed in children under 1 year old.Fever is the most common clinical manifestation of PM,and subdural effusion/emphysema and hydrocephalus are the most frequent complications.Non-culture detection methods for cerebrospinal fluid can improve pathogen detection rates.Adverse outcomes can be noted in more than 10% of PM cases.SP strains are high sensitivity to vancomycin,linezolid,meropenem,levofloxacin,moxifloxacin,rifampicin,and chloramphenicol.[Chinese Journal of Contemporary Pediatrics,2024,26(2):131-138]
6.Comparative study of minimally invasive titanium elastic nail and steel plate on the treatment of fracture of tibiofibu-lar fracture in adults
Hai-Bing ZHU ; Yong-Tao ZHANG ; He LYU ; Fu-Chang REN ; Cheng-Hong ZHOU ; Yun-Feng YING
China Journal of Orthopaedics and Traumatology 2024;37(4):352-357
Objective To compare the clinical outcomes of using elastic intramedullary nail and plate to fix fibular frac-ture.Methods The 60 patients with tibiofibular fractures admitted from January 2015 to December 2022 were divided into two groups:intramedullary nail group and plate group,30 cases each,intramedullary nail group was treated with elastic in-tramedullary nail fixation group,plate group was treated with steel plate and screw fixation group.Intramedullary nail group,there were 18 males and 12 females,aged from 22 to 75 years old with an average of(39.4±9.8)years old,including 24 cases of traffic accidents injury,6 cases of falling injury,23 cases of closed fractures,7 cases of open fractures.Steel plate group,there were 15 males and 15 females,aged from 24 to 78 years old with an average of(38.6±10.2)years old.The 22 cases were injured by traffic accident,8 cases were injured by falling.The 24 cases were closed fractures and 6 cases were open fractures.The operation time,intraoperative bleeding,American Orthopedic Foot and Ankle Society(AOFAS)ankle and hind foot scores,clinical healing time of fibula and the incidence of wound complications were compared between the two groups.Re-sults The patients in both groups were followed up for 6 to 21 months,with an average of(14.0±2.8)months.Compared with plate group,intramedullary nail group had shorter operative time,less bleeding,shorter clinical healing time of fibula,and low-er infection rate of incision,and the difference was statistically significant(P<0.05).There were 2 cases of delayed healing in intramedullary nail group,1 case of nonunion in plate group,and 2 cases of delayed healing in plate group,and there was no statistically significant difference between the two groups(P>0.05).In the last follow-up,according to the AOFAS scoring standard,the ankle function in intramedullary nail group was excellent in 17 cases,good in 12 cases,fair in 1 case,with an av-erage of(88.33±4.57)points,while in plate group,excellent in 16 cases,good in 10 cases,fair in 4 cases,with an average of(87.00±4.14)points;There was no statistical difference between the two groups(P>0.05).Conclusion Elastic intramedullary nail has the advantages of short operation time,less intraoperative bleeding,short fracture healing time and less incision com-plications in the treatment of fibular fracture,which is worthy of clinical application.
7.Finite element analysis of titanium rods after vertebral column decancellation osteotomy for ankylosing spondylitis
Bao-Ke SU ; Yong-Qing WANG ; Zhi-Jie KANG ; Hai-Yan WANG ; Feng JIN ; Xiao-He LI ; Zhen-Hua CAO ; Jia-Xuan HUO ; Yong ZHU ; Feng LI
Acta Anatomica Sinica 2024;55(3):339-344
Objective To analyze the stress changes of thoracic vertebra(T)11-sacrum(S)titanium rods in patients with ankylosing spondylitis after vertebral column decancellation(VCD)osteotomy,and provide reference for the selection and improvement of titanium rods before surgery.Methods The original data of the continuous scanning tomographic images of patients with ankylosing spondylitis after VCD osteotomy were imported into Mimics 21.0 in DICOM format,and T11-S vertebrae,screws and titanium rods were respectively reconstructed.They were imported into 3-Matic to establish a preliminary geometric modeling,and then processed with noise removal,paving,smoothing,etc.The improved model was imported into Hypermesh 10 software for grid division,and the material was imported into ANSYS 19.2 to display the finite element model after attribute assignment,Set the boundary and load conditions,and measure the stress value at the connection between the screw and the titanium rod.Results Under neutral position,forward bending,lateral bending,and axial rotation conditions,the titanium rod had the highest stress at the upper vertebrae(T11)and the lowest stress at the top vertebrae(L3);Under the backward extension condition,the titanium rod has the highest stress at the lower end vertebra(L5).Conclusion In the upper and lower vertebrae,it is possible to consider increasing the diameter of the titanium rod,enhancing its hardness,or changing it to a double rod.
8.Morphologic analysis and measurement of the posterior superior iliac spine of the hip bone in adolescents based on CT three-dimensional reconstruction
Li-Rong SHA ; Zhi-Jie KANG ; Hai-Yan WANG ; Yuan FANG ; Xiao-He LI ; Feng JING ; Kai ZHANG ; Yun-Feng ZHANG ; Yong ZHU ; Tong-Tong YUE
Acta Anatomica Sinica 2024;55(6):721-727
Objective To establish a normal three-dimensional model of the hip bone in adolescents aged 10-19 years old,analyze the morphology and positional parameters of the posterior superior iliac spine of the hip bone among different genders,sides,and ages,which can supplement the study of the anatomical morphology of the hip bone and to provide a reference for the diagnosis of the clinically relevant diseases and for the therapeutic manipulation and localization of the hip bone.Methods Forty adolescent patients aged 10-19 years without previous spinal pelvic diseases were selected,and the pelvic CT image data were collected and imported into Mimics 21.0 software to establish the model.The relative position parameters of the posterior superior iliac spine and the surrounding anatomical landmarks included the length from the posterior superior iliac spine to the anterior superior iliac spine(ab),the length from the tip of the posterior superior iliac spine to the sciatica(ac),the length from the tip of the posterior superior iliac spine to the pubic tubercle(ae),the length from the tip of the posterior superior iliac spine to the midpoint of the posterior margin of the auricular joint surfaces(af),the length from the tip of the posterior superior iliac spine to the iliac spine turn(ag),and the length from the sciatica tubercle to the highest point of the iliac spine(cd).The local parameters of the posterior superior iliac spine included the width(W0)and the thickness(H0)at point A.The maximum width of the posterior iliac spine(WMAX),its distance from point a(D0),and the width of the iliac spine were measured at 0.5,1,and 1.5 cm from point a,and were recorded sequentially as W1,W2,and W3.The width of the iliac spine at the turn of the iliac spine(point g)was measured(W4).The relative positions and parameters of the posterior superior iliac spine to the surrounding anatomical landmarks and the localized parameters of the posterior superior iliac spine were compared sequentially for different genders,sides,and age groups.Results In the measurement result of the parameters of the posterior superior iliac spine and the surrounding anatomical landmarks,the differences in the comparisons between different genders of the ac,ae,and af indexes were statistically significant(P<0.05),and the differences in the comparisons between different genders of the ab,ag,and cd indexes were not statistically significant(P>0.05).The differences in the comparisons between the right and left sides of the ab,ac,ae,af,ag,and cd indexes were not statistically significant(P>0.05).The difference in comparison between different age groups of ab,ac,ae,af,ag,and cd indicators was statistically significant(P<0.05).In the measurement result of the local parameters of the posterior superior iliac spine,the difference in the comparison between the sexes of the W0,W1,W2,WMAX,and H0 indexes was statistically significant(P<0.05),and the difference in the comparison between the sexes of the W3,W4,and D0 indexes was not statistically significant(P>0.05);And the difference in the comparison between the left and right sides of the W0,W1,W2,and the right and left sides of the W3,W4,WMAX,D0,and H0 indexes was not statistically significant(P>0.05);The difference between W0,W1,W2,W3,W4,WMAX,D0,H0 indicators compared between different age groups was not statistically significant(P>0.05).Conclusion Adolescent females have overall greater pelvic parameters than males,with wider and thicker tips of the posterior superior iliac spine in females and narrower and thinner tips of the posterior superior iliac spine in males;Pelvic parameters show a tendency to increase with age,while the width and thickness of the posterior superior iliac spine,as well as the width of the cephalic end to the iliac spine remain essentially unchanged.
9.Exploration of potential biomarkers and therapeutic targets for trauma-related acute kidney injury
Peng QI ; Meng-Jie HUANG ; Wei WU ; Xue-Wen REN ; Yong-Zhi ZHAI ; Chen QIU ; Hai-Yan ZHU
Chinese Journal of Traumatology 2024;27(2):97-106
Purpose::Acute kidney injury (AKI) is one of the most common functional injuries observed in trauma patients. However, certain trauma medications may exacerbate renal injury. Therefore, the early detection of trauma-related AKI holds paramount importance in improving trauma prognosis.Methods::Qualified datasets were selected from public databases, and common differentially expressed genes related to trauma-induced AKI and hub genes were identified through enrichment analysis and the establishment of protein-protein interaction (PPI) networks. Additionally, the specificity of these hub genes was investigated using the sepsis dataset and conducted a comprehensive literature review to assess their plausibility. The raw data from both datasets were downloaded using R software (version 4.2.1) and processed with the "affy" package19 for correction and normalization.Results::Our analysis revealed 585 upregulated and 629 downregulated differentially expressed genes in the AKI dataset, along with 586 upregulated and 948 downregulated differentially expressed genes in the trauma dataset. Concurrently, the establishment of the PPI network and subsequent topological analysis highlighted key hub genes, including CD44, CD163, TIMP metallopeptidase inhibitor 1, cytochrome b-245 beta chain, versican, membrane spanning 4-domains A4A, mitogen-activated protein kinase 14, and early growth response 1. Notably, their receiver operating characteristic curves displayed areas exceeding 75%, indicating good diagnostic performance. Moreover, our findings postulated a unique molecular mechanism underlying trauma-related AKI. Conclusion::This study presents an alternative strategy for the early diagnosis and treatment of trauma-related AKI, based on the identification of potential biomarkers and therapeutic targets. Additionally, this study provides theoretical references for elucidating the mechanisms of trauma-related AKI.
10.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve

Result Analysis
Print
Save
E-mail