1.Self-Reported Findings of the Korean Intermittent Exotropia Multicenter Study Questionnaire
Hee Kyung YANG ; Shin Hae PARK ; Haeng-Jin LEE ; Sook-Young KIM ; Hyo Jung GYE ; So Young KIM ; Sun Young SHIN ; Key Hwan LIM ;
Korean Journal of Ophthalmology 2024;38(3):194-202
Purpose:
To determine subjective symptoms and medical history of patients with intermittent exotropia in a large study population.
Methods:
The Korean Intermittent Exotropia Multicenter Study (KIEMS) is a nationwide, observational, cross-sectional, multicenter study conducted by the Korean Association for Pediatric Ophthalmology and Strabismus including 5,385 patients with intermittent exotropia. Subjective symptoms and medical history of patients with intermittent exotropia were extracted by a comprehensive survey based on a self-administered questionnaire according to the study protocol of the KIEMS.
Results:
The mean age of symptom onset was 5.5 years. The most common symptom reported in patients with intermittent exotropia was photophobia (52.1%), followed by diplopia at near fixation (7.3%) and distance fixation (6.2%). Preterm birth was found in 8.8%, and 4.1% had perinatal complications. A family history of strabismus was present in 14.9%, and 5.5% of patients had a family member who underwent strabismus surgery.
Conclusions
The KIEMS is one of the largest clinical studies on intermittent exotropia. Intermittent exotropia frequently caused photophobia and diplopia, and patients with a family history was not uncommon.
2.Non-glaucomatous Retinal Nerve Fiber Layer Defect Associated with Paravascular Inner Retinal Defect
Gye Jung KIM ; Dong Hwan SON ; Jin Soo KIM ; Min Chul SHIN
Journal of the Korean Ophthalmological Society 2020;61(2):214-220
PURPOSE: To report a case of non-glaucomatous retinal nerve fiber layer (RNFL) defect associated with paravascular inner retinal defect (PIRD) in a patient with idiopathic epiretinal membrane (ERM).CASE SUMMARY: A 70-year-old male who was diagnosed with ERM in his right eye and pseudoexfoliative glaucoma in his left eye visited our clinic. His intraocular pressure was 14 mmHg in both eyes while using topical hypotensive medications in both eyes. His right eye showed no glaucomatous change of the optic disc head, and also no glaucomatous visual field defect on standard automated perimetry. Red-free fundus photography and swept-source optical coherence tomography showed an ERM and wedge-shaped RNFL defect starting from the PIRD, not the optic disc head. He was diagnosed with non-glaucomatous RNFL defect in the right eye and was told to stop using topical hypotensive medication for the right eye. After 2 years of discontinuing the medication, the IOP was within the normal range, the RNFL defect showed no progression, and the visual field remained stationary.CONCLUSIONS: A non-glaucomatous RNFL defect can develop in association with PIRD in patients with idiopathic ERM. Examinations for PIRD as well as evaluation of the optic disc head are therefore necessary in patients with ERM and RNFL defect.
Aged
;
Epiretinal Membrane
;
Glaucoma
;
Head
;
Humans
;
Intraocular Pressure
;
Male
;
Nerve Fibers
;
Photography
;
Reference Values
;
Retinaldehyde
;
Tomography, Optical Coherence
;
Visual Field Tests
;
Visual Fields
3.The job competency of radiological technologists in Korea based on specialists opinion and questionnaire survey.
Chang Seon LIM ; Yang Sub LEE ; Yong Dae LEE ; Hyun Soo KIM ; Gye Hwan JIN ; Seong Youl CHOI ; Yera HUR
Journal of Educational Evaluation for Health Professions 2017;14(1):9-
PURPOSE: Although there are over 40,000 licensed radiological technologists (RTs) in Korea, job competency standards have yet to be defined. This study aims to clarify the job competency of Korean RTs. METHODS: A task force team of 11 professional RTs were recruited in order to analyze the job competency of domestic and international RTs. A draft for the job competency of Korean RTs was prepared. A survey was then conducted sampling RTs and the attitudes of their competencies were recorded from May 21 to July 30, 2016. RESULTS: We identified five modules of professionalism, patient management, health and safety, operation of equipment, and procedure management and 131 detailed job competencies for RTs in Korea. “Health and safety” had the highest average score and “professionalism” had the lowest average score for both job performance and importance. The content validity ratios for the 131 subcompetencies were mostly valid. CONCLUSION: Establishment of standard guidelines for RT job competency for multidisciplinary healthcare at medical institutions may be possible based on our results, which will help educators of RT training institutions to clarify their training and education.
Advisory Committees
;
Delivery of Health Care
;
Education
;
Humans
;
Korea*
;
Licensure
;
Professionalism
;
Republic of Korea
;
Specialization*
;
Technology, Radiologic
;
Work Performance
4.Long-Term Safety and Efficacy of Sirolimus- and Paclitaxel-Eluting Stents in Patients With Acute Myocardial Infarction: Four-Year Observational Study.
Gye Sik MIN ; Jae Hwan LEE ; Jae Ho PARK ; Ung Lim CHOI ; Young Dal LEE ; Seok Woo SEONG ; Seon Ah JIN ; Soo Jin PARK ; Jun Hyeong KIM ; Jae Hyeong PARK ; Si Wan CHOI ; Jin Ok JEONG ; In Whan SEONG
Korean Circulation Journal 2012;42(4):266-273
BACKGROUND AND OBJECTIVES: The comparison of long-term clinical effects between Sirolimus-eluting stent (SES) and Paclitaxel-eluting stents (PES) for treatment of acute myocardial infarction (AMI) remains unclear. Seeking to clarify this issue, we performed a retrospective analysis to evaluate four-year clinical outcomes of SES compared to PES treated AMI patients. SUBJECTS AND METHODS: From January 2004 to August 2006, all patients with acute ST-segment elevation myocardial infarction and acute non-ST segment elevation myocardial infarction who underwent percutaneous coronary intervention (PCI) by implantation of either SES or PES were enrolled. The occurrences of cardiac and non-cardiac deaths, recurrent infarction, target vessel revascularization (TVR) and stent thrombosis were analyzed. The composite end points of these major adverse cardiac events (MACE) were also analyzed. RESULTS: During the study period, a total of 668 AMI patients had visited, of which 522 patients (299 with SES and 223 with PES) were enrolled. During the four-year clinical follow-up, both groups showed similar occurrences of non-cardiac death (14.6+/-2.2% vs. 18.3+/-3.0%, p=0.26); cardiac death (6.8+/-1.52% vs. 11.2+/-2.6%, p=0.39); re-infarction (3.3+/-1.1% vs. 6.4+/-1.8%, p=0.31); and stent thrombosis (3.2+/-1.1% vs. 5.4+/-1.7%, p=0.53). However, occurrences of TVR {4.0+/-1.2% vs. 10.0+/-3.0%, hazard ratio (HR)=0.498, 95% confidence interval (CI)=0.257-0.967, p=0.039} and MACE (19.4+/-2.5% vs. 29.4+/-3.5%, HR=0.645, 95% CI=0.443-0.940, p=0.021) were significantly lower in the SES population. CONCLUSION: In AMI patients treated with either SES or PES implantation, the former had a significantly lower risk of TVR and MACE during four-year clinical follow-up. Rates of death, cardiac death or recurrent infarction, and stent thrombosis were similar.
Death
;
Follow-Up Studies
;
Glycosaminoglycans
;
Humans
;
Infarction
;
Myocardial Infarction
;
Percutaneous Coronary Intervention
;
Retrospective Studies
;
Stents
;
Thrombosis
5.Treatment outcome of uterine compression sutures for massive postpartum hemorrhage.
Yong Hwa CHAE ; Yun Young KIM ; Gye Hyeong AN ; Jang Hwan WOO ; Jin Hoon CHUNG ; June Seek CHOI ; Hyun Mee RYU ; Moon Young KIM ; Jae Hyug YANG ; Min Hyoung KIM
Korean Journal of Obstetrics and Gynecology 2010;53(9):769-777
OBJECTIVE: Uterine compression sutures such as modified B-Lynch suture or multiple square-shaped sutures of uterine body are simple methods for control of postpartum hemorrhage refractory to medical treatment. We evaluated the treatment outcome and morbidity of uterine compression sutures and analyzed clinical findings of patients undergone uterine compression sutures and postpartum hysterectomy. METHODS: From January 2005 through December 2008, we retrospectively reviewed the medical records of patients undergone uterine compression sutures or postpartum hysterectomy. We analyzed success rates of preserving uterus of uterine compression sutures according to operative indications and mode of delivery and compared maternal characteristics, operative findings, morbidities and mortality with those of postpartum hysterectomy. RESULTS: The frequency of uterine compression sutures for control of massive postpartum hemorrhage was 0.24% (73/30,677). The success rates of preserving uterus were 85.1% in uterine atony, 80.9% in placenta previa, and 40.0% in placenta accreta (P=0.051). The rates of preserving uterus of uterine compression sutures after vaginal delivery and cesarean section were 50.0% and 82.6%, respectively (P=0.164). The frequencies of postoperative morbidities such as disseminated intravascular coagulation, pulmonary edema, ileus were not different between immediate hysterectomy and hysterectomy after uterine compression sutures. There was no maternal mortality. CONCLUSION: Uterine compression suture was successful method for control of postpartum hemorrhage resulting from uterine atony and placenta previa. We suggest the use of uterine compression sutures as the first-line operation for control of postpartum hemorrhage.
Cesarean Section
;
Disseminated Intravascular Coagulation
;
Female
;
Humans
;
Hysterectomy
;
Ileus
;
Maternal Mortality
;
Medical Records
;
Placenta Accreta
;
Placenta Previa
;
Postpartum Hemorrhage
;
Postpartum Period
;
Pregnancy
;
Pulmonary Edema
;
Retrospective Studies
;
Sutures
;
Treatment Outcome
;
Uterine Inertia
;
Uterus
6.Quality Control of Radiation Dosimetry Service.
Jun Haeng LEE ; Sang Bock LEE ; Kun Jo CHANG ; Kwang Yong LEE ; Hyun Koo LEE ; Hyeog Ju KIM ; Gye Hwan JIN
Korean Journal of Medical Physics 2009;20(4):253-259
We have developed standards based on international criterions for the quality control of dose tested by the measurement institutions of individual exposure doses through improving the reliability of data on the exposure dose of individuals working in radioactive environment and securing the accuracy and reliability of individual dose measurements. Laws related to radiation dose applied to domestic institutions refer to ANSI N13.11?1993, but currently , in U.S. and some other countries the measurement of radiation doses is based on ANSI N13.11?2001 that reduced test categories and tightened the standards. We made efforts to simplify the standards and to reduce the number of dosimeters required in experiment, and avoided preventing or hindering the use of future technologies not approved under the current law such as glass dosimeter and optical stimulation dosimeter. The Quality Management Manual of Radiation Dosimetry Service, Assessment Manual of Radiation Dosimetry Service Accreditation Program, and the Personnel Dosimetry Performance-Criteria for Testing are documents applicable in supervising laboratories.
Accreditation
;
Glass
;
Jurisprudence
;
Quality Control
;
Radiometry
7.Comparison of F-18 FDG Radioacitivity to Determine Accurate Dose Calibrator Activity Measurements.
Gye Hwan JIN ; Dae Cheol KWEON ; Ki Baek OH ; Hoon Hee PARK ; Jung Yul KIM ; Min Soo PARK ; Dae Sung PARK
Korean Journal of Medical Physics 2009;20(3):159-166
Obviously, the administration of the prescribed amount of activity to the patient requires proper operation of the dose calibrator, which shall be verified by implementing the required quality control on the instrument. This investigation examined the accuracy and precision of dose calibrator activity measurement of the radiopharmaceutical F-18 FDG. To investigate the status of the nuclear medicine centers in Korea for the performance of dose calibrators, 10 centers providing PET/CT system services in Korea were inspected in 2008. We measured accuracy and precision in 10 equipments in consideration of PET/CT model, installation area, and installation time. According to the results of comparative analysis of 10 dose calibrators used to measure radioactivity of F-18 FDG, accuracy was -5.00~4.50% and precision was 0.05~0.45%, satisfying the international standards, which are accuracy +/-10% and precision +/-5%. This study demonstrated that, for accurate measurements, no adjustment is necessary for a dose calibrator setting when measuring different dose calibrators of F-18 FDG activity prescriptions.
Humans
;
Korea
;
Nuclear Medicine
;
Quality Control
;
Radioactivity
8.Comparison of F-18 FDG Radioacitivity to Determine Accurate Dose Calibrator Activity Measurements.
Gye Hwan JIN ; Dae Cheol KWEON ; Ki Baek OH ; Hoon Hee PARK ; Jung Yul KIM ; Min Soo PARK ; Dae Sung PARK
Korean Journal of Medical Physics 2009;20(3):159-166
Obviously, the administration of the prescribed amount of activity to the patient requires proper operation of the dose calibrator, which shall be verified by implementing the required quality control on the instrument. This investigation examined the accuracy and precision of dose calibrator activity measurement of the radiopharmaceutical F-18 FDG. To investigate the status of the nuclear medicine centers in Korea for the performance of dose calibrators, 10 centers providing PET/CT system services in Korea were inspected in 2008. We measured accuracy and precision in 10 equipments in consideration of PET/CT model, installation area, and installation time. According to the results of comparative analysis of 10 dose calibrators used to measure radioactivity of F-18 FDG, accuracy was -5.00~4.50% and precision was 0.05~0.45%, satisfying the international standards, which are accuracy +/-10% and precision +/-5%. This study demonstrated that, for accurate measurements, no adjustment is necessary for a dose calibrator setting when measuring different dose calibrators of F-18 FDG activity prescriptions.
Humans
;
Korea
;
Nuclear Medicine
;
Quality Control
;
Radioactivity
9.Fetal Anomaly and Pregnancy Outcomes after Exposure to Ibuprofen in First Trimester of Pregnancy.
Gye Hyeong AN ; June Seek CHOI ; Jung Yeol HAN ; Hyun Kyeong AHN ; Jae Hyug YANG ; Moon Young KIM ; Hyun Mee RYU ; Min Hyoung KIM ; Jin Hoon CHUNG ; Kyu Hong CHOI ; Si Won LEE ; Yun Young KIM ; Yong Hwa CHAE ; Jang Hwan WOO
Korean Journal of Perinatology 2009;20(4):346-353
PURPOSE: Ibuprofen is a non steroidal anti-inflammatory drug used for treating fever and pain including headache, arthralgia, and back pain. There is scarce information on the safety of ibuprofen associated with fetal anomaly when used early in pregnancy. Epidemiology studies have suggested that use of NSAIDs, including ibuprofen, during pregnancy may increase the risk of cardiac defects and gastroschisis. The aim of the study was to evaluate fetal outcomes among pregnant women who were unintentionally exposed to ibuprofen in early pregnancy. METHODS: Total 381 pregnant women who were unintentionally exposed to ibuprofen during early pregnancy were prospectively followed up. In addition, 643 age and gravity matched pregnant women not exposed to any potential teratogenic agent during pregnancy were recruited as controls. Patients were followed-up until delivery or loss to follow-up. Newborns were examined in order to identify any major congenital malformation. RESULTS: Mean age of exposed women was 31.2+/-3.4 years, with a mean number of previous pregnancies of 2.3+/-1.2 and mean gestational weeks at exposure of 4.4+/-2.2. All gestations were confirmed by ultrasonography. Of exposed women, 17 (5.6%) had spontaneous abortions, 16 were on- going pregnancies, 1 had an intra-uterine fetal death, 21 artificial abortion and 55 cases were lost to follow-up. Therefore, 271 pregnancies unintentionally exposed to ibuprofen were evaluated, each delivering a singleton baby. Three babies had congenital anomalies: one had unilateral hydronephrosis, another baby was born with a unilateral inguinal hernia. The last baby was born with unilateral kidney dysplasia with megaureter. In the control group, 6 babies were born with major malformations [1.11% vs. 1.31% (P=0.552, OR: 0.841, 95% CI: 0.2 to 3.4)]. CONCLUSION: These preliminary results suggest that the ibuprofen may not be a major human teratogen.
Abortion, Spontaneous
;
Anti-Inflammatory Agents, Non-Steroidal
;
Arthralgia
;
Back Pain
;
Female
;
Fetal Death
;
Fever
;
Follow-Up Studies
;
Gastroschisis
;
Gravitation
;
Headache
;
Hernia, Inguinal
;
Humans
;
Hydronephrosis
;
Ibuprofen
;
Infant, Newborn
;
Kidney
;
Lost to Follow-Up
;
Pregnancy
;
Pregnancy Outcome
;
Pregnancy Trimester, First
;
Pregnant Women
;
Prospective Studies
10.Sarcoidosis Initially Presenting as a Nasal Cavity Mass Misdiagnosed as Tuberculosis.
Dong Ryeol CHAE ; Seong Uk LIM ; Gye Jung CHO ; Jung Hwan LIM ; Jin Yung JU ; Yong Soo KWON ; In Jae OH ; Kyu Sik KIM ; Yu Il KIM ; Sung Chul LIM ; Young Chul KIM
Tuberculosis and Respiratory Diseases 2008;65(2):121-124
We experienced a rare case of sinonasal sarcoidosis initially presenting as nasal cavitary mass. When the clinical course was different from that of typical tuberculosis, physician should think the possibility of sarcoidosis, and re-biopsy or retrospective review of pathological findings might be helpful.
Nasal Cavity
;
Retrospective Studies
;
Sarcoidosis
;
Tuberculosis

Result Analysis
Print
Save
E-mail