1.Analysis on spectrum characteristics of high-intensity noise in key industries in Guangdong Province
Jianyu GUO ; Guoyong XU ; Zhipeng HE ; Maosheng YAN ; Yongjian JIANG ; Hua YAN ; Bin XIAO
China Occupational Medicine 2024;51(2):156-162
ObjectiveTo analyze the spectrum distribution characteristics of high-intensity productive noise in key industries in Guangdong Province. Methods A total of 2 806 enterprises in 21 prefecture-level cities in Guangdong Province were selected as the study subjects using the stratified sampling method. On-site investigations were conducted in workplaces. Noise in workplaces and work-sites, and the noise spectrum of the workplaces with sound pressure level ≥85.0 dB(A) were detected. Results The noise of a total of 23 076 workplaces and 20 969 work sites from 30 key industries were monitored. The median (M) and 25th and 75th percentiles (P25, P75) of workplace sound pressure level were 82.3 (78.6, 86.5) dB(A). The rate of the noise exceeded national standard was 30.4%. The sound pressure level M (P25, P75) of work-site was 78.6 (70.0, 83.5) dB(A). The rate of the noise exceeded national standard was 18.0%. Workplace noise and work site noise were positively correlated (Spearman correlation coefficient=0.86, P<0.01). The rate of the noise exceeded national standard was 46.5% in key work sites where the rate of noise exceeded the national standard was ≥25.0%, and corresponding rate of the workplace noise exceeded national standard was 58.1%. The noise spectrum result of 5 636 workplaces sound pressure level>85.0 dB(A) showed that most of the noise source was from grinding machines (441 cases), and the highest average sound pressure level of noise source was from screening machines [93.0 dB(A)]. Cluster analysis results showed that the main noise sources could be divided into three categories, including wideband noise with levels >80.0 dB in all frequency bands except 8 000.0 Hz, medium-high-frequency noise with the highest sound pressure level at 1 000.0, 2 000.0, and 4 000.0 Hz and low frequencies <75.0 dB, and medium-low-frequency noise below 500.0 Hz with sound pressure level >85.0 dB. Conclusion The rate of the noise exceeded national standard in workplace of key industries in Guangdong Province is high, involving a wide range of industries, with high sound pressure levels and obvious spectrum characteristics of corresponding noise sources. Corresponding noise control strategies can be formulated based on different spectrum characteristics and magnitudes.
2.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.
3.Clinical guidelines for the diagnosis and treatment of osteoporotic thoracolumbar vertebral fracture with kyphotic deformity in the elderly (version 2024)
Jian CHEN ; Qingqing LI ; Jun GU ; Zhiyi HU ; Shujie ZHAO ; Zhenfei HUANG ; Tao JIANG ; Wei ZHOU ; Xiaojian CAO ; Yongxin REN ; Weihua CAI ; Lipeng YU ; Tao SUI ; Qian WANG ; Pengyu TANG ; Mengyuan WU ; Weihu MA ; Xuhua LU ; Hongjian LIU ; Zhongmin ZHANG ; Xiaozhong ZHOU ; Baorong HE ; Kainan LI ; Tengbo YU ; Xiaodong GUO ; Yongxiang WANG ; Yong HAI ; Jiangang SHI ; Baoshan XU ; Weishi LI ; Jinglong YAN ; Guangzhi NING ; Yongfei GUO ; Zhijun QIAO ; Feng ZHANG ; Fubing WANG ; Fuyang CHEN ; Yan JIA ; Xiaohua ZHOU ; Yuhui PENG ; Jin FAN ; Guoyong YIN
Chinese Journal of Trauma 2024;40(11):961-973
The incidence of osteoporotic thoracolumbar vertebral fracture (OTLVF) in the elderly is gradually increasing. The kyphotic deformity caused by various factors has become an important characteristic of OTLVF and has received increasing attention. Its clinical manifestations include pain, delayed nerve damage, sagittal imbalance, etc. Currently, the definition and diagnosis of OTLVF with kyphotic deformity in the elderly are still unclear. Although there are many treatment options, they are controversial. Existing guidelines or consensuses pay little attention to this type of fracture with kyphotic deformity. To this end, the Lumbar Education Working Group of the Spine Branch of the Chinese Medicine Education Association and Editorial Committee of Chinese Journal of Trauma organized the experts in the relevant fields to jointly develop Clinical guidelines for the diagnosis and treatment of osteoporotic thoracolumbar vertebral fractures with kyphotic deformity in the elderly ( version 2024), based on evidence-based medical advancements and the principles of scientificity, practicality, and advanced nature, which provided 18 recommendations to standardize the clinical diagnosis and treatment.
4.Analyzing the monitoring results of noise hazards in workplace of key industries in Guangdong Province in 2019
Jianyu GUO ; Danying ZHANG ; Guoyong XU ; Maosheng YAN ; Zhipeng HE ; Hua YAN ; Jiayu LIU ; Bin XIAO
China Occupational Medicine 2023;50(2):175-180
5.Vibration attenuation and dexterity of different types of protective gloves
Bin XIAO ; Yongjian JIANG ; Wei WEN ; Jianyu GUO ; Maosheng YAN ; Guoyong XU ; Zhipeng HE ; Hansheng LIN ; Hua YAN
Journal of Environmental and Occupational Medicine 2022;39(11):1214-1219
Background Wearing anti-vibration gloves is a simple and effective way to prevent hand-arm vibration disease. The requirements for vibration damping gloves are varied by types of operations exposed to vibration. Objective To study the vibration attenuation and dexterity of different types of protective gloves, and to provide reference for scientific wearing of vibration damping gloves for people working with vibration exposure. Methods Nine kinds of common protective gloves (A and B were dipping gloves; C, D, and E were rubber gloves; F and G were textile and fabric gloves; H was cotton gloves; I was leather gloves) used by workers exposed to vibration in 28 factories in Guangdong Province were selected as research objects by typical case sampling method, and the basic parameters of included protective gloves were investigated and measured. According to ISO 10819:2013, a glove vibration transmissibility (GVT) test system was used to detect the vibration transmissibility values and analyze vibration attenuation characteristics of the subjects wearing different protective gloves. The dexterity was tested by Minnesota Manual Dexterity Test. Pearson test was used to analyze the correlations among glove thickness, vibration transmissibility, dexterity score, and grip strength score. Results For rubber gloves (C, D, and E), the associated average adjusted vibration transmissibility at middle and low frequencies
6.Guideline for postoperative rehabilitation treatment following vertebral augmentation for osteoporotic vertebral compression fracture (version 2022)
Zhengwei XU ; Dingjun HAO ; Liming CHENG ; Baorong HE ; Bohua CHEN ; Chen CHEN ; Fei CHE ; Jian CHEN ; Qixin CHEN ; Liangjie DU ; Shunwu FAN ; Zhong FANG ; Shiqing FENG ; Yanzheng GAO ; Haishan GUAN ; Zhong GUAN ; Hua JIANG ; Weimin JIANG ; Dianming JIANG ; Jun JIANG ; Yue JIANG ; Lijun HE ; Yuan HE ; Bo LI ; Tao LI ; Jianjun LI ; Xigong LI ; Yijian LIANG ; Bin LIN ; Bin LIU ; Bo LIU ; Yong LIU ; Zhibin LIU ; Xuhua LU ; Chao MA ; Lie QIAN ; Renfu QUAN ; Hongxun SANG ; Haibo SHEN ; Jun SHU ; Honghui SUN ; Tiansheng SUN ; Jun TAN ; Mingxing TANG ; Sheng TAO ; Honglin TENG ; Yun TIAN ; Jiwei TIAN ; Qiang WANG ; Xinwei WANG ; Jianhuang WU ; Peigen XIE ; Weihong XU ; Bin YAN ; Yong YANG ; Guoyong YIN ; Xiaobing YU ; Yuhong ZENG ; Guoqing ZHANG ; Xiaobo ZHANG ; Jie ZHAO ; Yue ZHU
Chinese Journal of Trauma 2022;38(11):961-972
Osteoporotic vertebral compression fracture (OVCF) can lead to lower back pain and may be even accompanied by scoliosis, neurological dysfunction and other complications, which will affect the daily activities and life quality of patients. Vertebral augmentation is an effective treatment method for OVCF, but it cannot correct unbalance of bone metabolism or improve the osteoporotic status, causing complications like lower back pain, limited spinal activities and vertebral refracture. The post-operative systematic and standardized rehabilitation treatments can improve curative effect and therapeutic efficacy of anti-osteoporosis, reduce risk of vertebral refracture, increase patient compliance and improve quality of life. Since there still lack relevant clinical treatment guidelines for postoperative rehabilitation treatments following vertebral augmentation for OVCF, the current treatments are varied with uneven therapeutic effect. In order to standardize the postoperative rehabilitation treatment, the Spine Trauma Group of the Orthopedic Branch of Chinese Medical Doctor Association organized relevant experts to refer to relevant literature and develop the "Guideline for postoperative rehabilitation treatment following vertebral augmentation for osteoporotic vertebral compression fracture (2022 version)" based on the clinical guidelines published by the American Academy of Orthopedic Surgeons (AAOS) as well as on the principles of scientificity, practicality and advancement. The guideline provided evidence-based recommendations on 10 important issues related to postoperative rehabilitation treatments of OVCF.
7.Seroprevalence of influenza viruses in Shandong, Northern China during the COVID-19 pandemic.
Chuansong QUAN ; Zhenjie ZHANG ; Guoyong DING ; Fengwei SUN ; Hengxia ZHAO ; Qinghua LIU ; Chuanmin MA ; Jing WANG ; Liang WANG ; Wenbo ZHAO ; Jinjie HE ; Yu WANG ; Qian HE ; Michael J CARR ; Dayan WANG ; Qiang XIAO ; Weifeng SHI
Frontiers of Medicine 2022;():1-7
Nonpharmaceutical interventions (NPIs) have been commonly deployed to prevent and control the spread of the coronavirus disease 2019 (COVID-19), resulting in a worldwide decline in influenza prevalence. However, the influenza risk in China warrants cautious assessment. We conducted a cross-sectional, seroepidemiological study in Shandong Province, Northern China in mid-2021. Hemagglutination inhibition was performed to test antibodies against four influenza vaccine strains. A combination of descriptive and meta-analyses was adopted to compare the seroprevalence of influenza antibodies before and during the COVID-19 pandemic. The overall seroprevalence values against A/H1N1pdm09, A/H3N2, B/Victoria, and B/Yamagata were 17.8% (95% CI 16.2%-19.5%), 23.5% (95% CI 21.7%-25.4%), 7.6% (95% CI 6.6%-8.7%), and 15.0 (95% CI 13.5%-16.5%), respectively, in the study period. The overall vaccination rate was extremely low (2.6%). Our results revealed that antibody titers in vaccinated participants were significantly higher than those in unvaccinated individuals (P < 0.001). Notably, the meta-analysis showed that antibodies against A/H1N1pdm09 and A/H3N2 were significantly low in adults after the COVID-19 pandemic (P < 0.01). Increasing vaccination rates and maintaining NPIs are recommended to prevent an elevated influenza risk in China.
8.Clinical guideline for spinal reconstruction of osteoporotic thoracolumbar fracture in elderly patients (version 2022)
Tao SUI ; Jian CHEN ; Zhenfei HUANG ; Zhiyi HU ; Weihua CAI ; Lipeng YU ; Xiaojian CAO ; Wei ZHOU ; Qingqing LI ; Jin FAN ; Qian WANG ; Pengyu TANG ; Shujie ZHAO ; Lin CHEN ; Zhiming CUI ; Wenyuan DING ; Shiqing FENG ; Xinmin FENG ; Yanzheng GAO ; Baorong HE ; Jianzhong HUO ; Haijun LI ; Jun LIU ; Fei LUO ; Chao MA ; Zhijun QIAO ; Qiang WANG ; Shouguo WANG ; Xiaotao WU ; Nanwei XU ; Jinglong YAN ; Zhaoming YE ; Feng YUAN ; Jishan YUAN ; Jie ZHAO ; Xiaozhong ZHOU ; Mengyuan WU ; Yongxin REN ; Guoyong YIN
Chinese Journal of Trauma 2022;38(12):1057-1066
Osteoporotic thoracolumbar fracture in the elderly will seriously reduce their quality of life and life expectancy. For osteoporotic thoracolumbar fracture in the elderly, spinal reconstruction is necessary, which should comprehensively consider factors such as the physical condition, fracture type, clinical characteristics and osteoporosis degree. While there lacks relevant clinical norms or guidelines on selection of spinal reconstruction strategies. In order to standardize the concept of spinal reconstruction for osteoporotic thoracolumbar fracture in the elderly, based on the principles of scientificity, practicality and progressiveness, the authors formulated the Clinical guideline for spinal reconstruction of osteoporotic thoracolumbar fracture in elderly patients ( version 2022), in which suggestions based on evidence of evidence-based medicine were put forward upon 10 important issues related to the fracture classification, non-operative treatment strategies and surgical treatment strategies in spinal reconstruction after osteoporosis thoracolumbar fracture in the elderly, hoping to provide a reference for clinical treatment.
9. Characteristics of noise hazard in a nuclear power station
Danying ZHANG ; Zhipeng HE ; Xinqi LIN ; Guoyong XU ; Maosheng YAN ; Hua YAN ; Hansheng LIN
China Occupational Medicine 2020;47(04):447-450
OBJECTIVE: To analyze the characteristics of noise hazard in a nuclear power station. METHODS: The workplaces and working posts which exposed to occupational noise from two 1 000 MW power units in one nuclear power station in Guangdong Province was selected as study subjects using the convenience sampling method. Occupational health survey, noise measurement in the workplace and personal noise dosage measurement were used to monitor noise exposure, and to analyze the characteristics of occupational noise in the nuclear power station. RESULTS: The noise sources of the nuclear power plant were mainly distributed in the nuclear island, conventional island, and peripheral workshops. A total of 237 points of noise intensity were measured in the workplace. The intensity of noise ranged from 66.0 to 99.6 dB(A). The noise intensity in 62.4%(148/237) of points was equal or greater than 80.0 dB(A) and 34.2%(81/237) equal or greater than 85.0 dB(A). The percentage of detection points with noise intensity was equal or greater than 85.0 dB(A) from low to high were nuclear island, conventional island, and peripheral workshops with 22.0%, 37.5% and 53.8% respectively(P<0.01). The personal noise intensity of three positions including inspectors of operation department, preparation and main engine positions of mechanical department exceeded the occupational exposure limit(OEL), and the percentage of positions whose noise intensity exceeded the OEL was 9.7%(3/31). CONCLUSION: High-intensity noise sources of the nuclear power plant are widely distributed in the workshop areas of nuclear island, conventional island, and peripheral workshops. The noise level of some positions exceeded the standards of noise intensity. The prevention and control measures of noise hazards in posts with excessive noise should be strengthened.
10. Current status of occupational exposure to power frequency electromagnetic field in converter stations
Guoyong XU ; Xinqi LIN ; Zhipeng HE ; Lei LIU ; Bin LI ; Tianwei LI ; Yongxin LIANG
China Occupational Medicine 2020;47(06):681-685
OBJECTIVE: To analyze the current status of occupational exposure to power frequency electromagnetic field in converter stations. METHODS: Eight converter stations with voltage levels of ±500 kV and ±800 kV within normal operation were selected as the research subjects using the typical sampling method. Power frequency electric field and power frequency magnetic field strengths were measured and calculated according to the GBZ/T 189.3-2018 Measurement of Physical Agents in Workplace--Part 3: Electric Field and Magnetic Field between 1 Hz and 100 kHz. The GBZ 2.2-2007 Occupational Exposure Limits for Hazardous Factors in the Workplace--Part 2: Physical Factors were used to evaluate whether the power frequency electric field strength exceeds the regulatory limit(the occupational exposure limit of power frequency electric field in 8 hours workplace is 5.000 kV/m). Meanwhile, the test results were evaluated according to the short-term occupational exposure limit of 50 Hz electric field and magnetic field recommended by the International Committee on Nonionizing Radiation Protection in 2010 that are 10.000 kV/m and 1 000.00 μT. RESULTS: The power frequency electric field and magnetic field strengths of 582 working environment detection points were measured. The median and 0-100 th percentile of power frequency electric field and power frequency magnetic field strength were 4.342(0.001-12.003) kV/m and 5.51(0.10-186.90) μT, respectively.The exceeding standard rate of power frequency electric field strength in converter station workplaces was 37.8%(220/582), which concentrated in 500 kV alternating current filter area and 500 kV alternating current field area. Among them, 5 detection points had power frequency electric field strength exceeding 10.000 kV/m. The magnetic flux density of all the detection points did not exceed 1 000.00 μT. The power frequency electric field strength in ultra-high voltage region was higher than that in high voltage region(P<0.01). There was no significant difference in power frequency magnetic field strength(P>0.05). There was no significant difference in power frequency electric field and magnetic field between rectifier stations and inverter stations(P>0.05). The 8 hours time weighted average(TWA) value of power frequency electric field strength of 8 converter station operators was 1.044-2.335 kV/m, which did not exceed the occupational exposure limit. CONCLUSION: The converter station operators might be exposed to excessive power frequency electric fields for a short time, but the 8 hours TWA value of the power frequency electric field meets the requirements of standards, and the power frequency magnetic field exposure strength also meets the requirements of the relevant standards.

Result Analysis
Print
Save
E-mail