1.Influence of PVE and PVE combined with TACE on secondary hepatectomy and prognosis of hepatocellular carcinoma
Junsheng NI ; Yao LI ; Xue LIU ; Guojun HOU ; Linghao ZHAO ; Yuan YANG ; Yefa YANG ; Weiping ZHOU
Chinese Journal of Digestive Surgery 2024;23(2):257-264
Objective:To investigate the influencing of portal vein embolization (PVE) and PVE combined with transcatheter arterial chemoembolization (TACE) on secondary hepatectomy and prognosis of patients with initially unresectable hepatocellular carcinoma (HCC).Methods:The retrospective cohort study was conducted. The clinicopathological data of 102 patients with initially unresectable HCC who were admitted to the Third Affiliated Hospital of Naval Medical University from October 26,2015 to December 31,2022 were collected. There were 82 males and 20 females, aged 52(range,25?73)years. Of 102 patients, 72 cases undergoing PVE combined with TACE were set as the PVE+TACE group, and 30 cases undergoing PVE were set as the PVE group. Observation indicators: (1) surgical resection rate of secondary hepatectomy and increase of future liver remnant (FLR); (2) situations of secondary hepatectomy; (3) follow-up. Measurement data with normal distribution were represented as Mean± SD, and comparison between groups was conducted using the independent sample t test. Measurement data with skewed distribution were represented as M(range), and comparison between groups was conducted using the Mann-Whitney U test. Count data were described as absolute numbers, and comparison between groups was conducted using the chi-square test or Fisher exact probability. Comparison of ordinal data was conducted using the Mann-Whitney U test. The Kaplan-Meier method was used to calculate survival rate and draw survival curve, and Log-Rank test was used for survival analysis. Results:(1) Surgical resection rate of secondary hepatectomy and increase of FLR. The surgical resection rate of secondary hepatectomy in the PVE+TACE group and the PVE group were 72.2%(52/72) and 53.3%(16/30), respectively, showing no significant difference between the two groups ( χ2=3.400, P>0.05). The surgical waiting time, increasing volume of FLR, growth rate of FLR in the 52 patients of PVE+TACE group receiving secon-dary hepatectomy were 20(range, 14?140)days, 140(range, 62?424)mL, 9.8(range, 1.5?26.5)mL/day, respectively. The above indicators in the 16 patients of PVE group receiving secondary hepatectomy were 16(range, 12?35)days, 160(range, 95?408)mL, 10.5(range, 1.2?28.0)mL/day, respectively. There was no significant difference in the above indicators between the 52 patients of PVE+TACE group and the 16 patients of PVE group ( Z=1.830, 1.498, 1.266, P>0.05). (2) Situations of secondary hepatectomy. The operation time, rate of tumor necrosis (>90%, 60%?90%,<60%), cases with complications ≥ grade Ⅲa in the 52 patients of PVE+TACE group receiving secondary hepatectomy were 200(range, 125?420)minutes, 8, 4, 40, 28, respectively. The above indicators in the 16 patients of PVE group receiving secondary hepatectomy were 170(range, 105?320)minutes, 0, 0, 16, 4, respectively. There were significant differences in the above indicators between the 52 patients of PVE+TACE group and the 16 patients of PVE group ( Z=2.132, ?2.093, χ2=4.087, P<0.05). (3) Follow-up. Sixty-eight patients who completed the surgery were followed up for 40(range, 10?84)months. The 1-, 3-, 5-year recurrence free survival rate in the 52 patients of PVE+TACE group receiving secondary hepatectomy were 73.0%, 53.3%, 35.4%, respectively. The above indicators in the 16 patients of PVE group were 62.5%, 37.5%, 18.8%, respectively. There was a significant difference in the recurrence free survival rate between the 52 patients of PVE+TACE group and the 16 patients of PVE group ( χ2=4.035, P<0.05). The 1-, 3-, 5-year overall survival rate in the 52 patients of PVE+TACE group receiving secondary hepatectomy were 82.5%, 61.2%, 36.6%, respectively. The above indica-tors in the 16 patients of PVE group receiving secondary hepatectomy were 68.8%, 41.7%,20.8%, respectively. There was a significant difference in the overall survival rate between the 52 patients of PVE+TACE group and the 16 patients of PVE group ( χ2=4.767, P<0.05). Conclusion:Compared with PVE, PVE+TACE as stage Ⅰ surgery can increase the surgical resection rate of secondary hepatec-tomy and the recurrence free survival rate of patients with initially unresectable HCC, prolong the long-term survival time, but not influence the growth rate of FLR.
2.Progress of High-Resolution Magnetic Resonance Vessel Wall Imaging in the Evaluation of Pathogenesis and Treatment of Intracranial Atherosclerosis-Related Ischemic Stroke
Xuelian WANG ; Fei WANG ; Xincheng LIU ; Tao YUAN ; Lijuan GAO ; Guojun TAN ; Guanmin QUAN
Chinese Journal of Medical Imaging 2024;32(7):747-752
Intracranial atherosclerosis has been regard as the most common cause of ischemic stroke.The information of the types and degree of vascular wall lesions is important basis for the diagnosis and treatment of ischemic stroke.High-resolution MR vessel wall imaging can directly display the lumen and wall of intracranial vessels,evaluate the characteristics of atherosclerotic plaque qualitatively and quantitatively,including intra-plaque hemorrhage,plaque enhancement,and plaque distribution.Thus,high-resolution MR vessel wall imaging may play an important role in risk stratification,pathogenesis,treatment and prognosis evaluation in ischemic stroke patients.This review summarizes the progress of high-resolution MRI vessel wall imaging in the evaluation of intracranial atherosclerosis,especially the pathogenesis of plaque features and treatment-related information.
3.Development of a simplified phantom for calibration of whole-body counter
Jianhua WU ; Hongchao PANG ; Zhiping LUO ; Yang LIU ; Xinglong LI ; Guojun YUAN
Chinese Journal of Radiological Health 2023;32(3):259-263
Objective To develop a simplified phantom for the calibration of whole-body counters. Methods A simplified phantom design method for the calibration of whole-body counters was established based on the process and method of calibrating whole-body counters. By using the established method and Monte Carlo method, a simplified phantom including the total body, thyroid, lungs, and gastrointestinal tract was designed to calibrate the ORTEC-Stand FAST II whole-body counter. The simplified phantom was compared with the BOMAB phantom through experimental measurements. Results Within the range of 50 keV to 2 MeV, for rays of the same energy in the same organ of the simplified phantom and BOMAB phantom, the simulated data of detection efficiency by whole-body counting showed an error within 5%, and the experimental measurements showed an error within 10%. Conclusion We developed a simplified phantom for the calibration of the whole-body counter, demonstrating the feasibility of using the simplified phantom instead of a physical body phantom for whole-body counter calibration, which can greatly facilitate whole-body counter calibration for internal radiation monitoring.
4.Clinical efficacy of portal vein embolization with different embolization materials in patients with initially unresectable hepatocellular carcinoma
Junsheng NI ; Yao LI ; Huifen LI ; Tao TIAN ; Guojun HOU ; Yuan YANG ; Weiping ZHOU
Chinese Journal of Hepatobiliary Surgery 2023;29(6):406-411
Objective:To study the clinical effects of portal vein embolization (PVE) with N-butyl cyanoacrylate copolymer (NBCA) and with gelatin sponge (GS) as embolization materials in patients with initially unresectable hepatocellular carcinoma (HCC).Methods:Clinical data of 90 patients with initial unresectable HCC who underwent PVE treatment at the Third Affiliated Hospital of Naval Medical University from November 2014 to April 2020 were included. There were 77 males and 13 females, aged 48 (25, 67) years old. Patients were divided into two groups according to the embolization materials selected in PVE: NBCA group ( n=60) and GS group ( n=30). Forty-eight and 18 patients finally underwent secondary hepatectomy in NBCA group (resectable NBCA group) and GS group (resectable GS group), respectively. Clinical data including future liver remnant (FLR) growth rate and secondary hepatectomy rate were analyzed. Survivals after hepatectomy was followed up by telephone, WeChat, and outpatient review. Results:The secondary hepatectomy rate in NBCA group was higher than that in GS group [80%(48/60) vs. 60%(18/30), P=0.043]. The waiting time from primary intervention to secondary hepatectomy in resectable NBCA group was 15 (7, 96) d, which was shorter than that in resectable GS group [40 (28, 118) d, P<0.001]. The FLR growth rate of resectable NBCA group was 9.03 (1.24, 29.64) ml/d, which was faster than that in resectable GS group [3.76 (0.08, 8.03) ml/d, P<0.001]. The recurrence-free survival (RFS) rates of patients in resectable NBCA group were 69.1%, 62.0% and 44.7% at 1, 2 and 3 years after surgery, and the overall survival (OS) rates were 76.4%, 69.5% and 59.6%, respectively. The RFS rates of patients in resectable GS group were 60.6%, 48.5% and 35.4% at 1, 2 and 3 years after surgery, and the OS rates were 66.7%, 60.6% and 42.4%, respectively. There were no significant differences in RFS and OS between two groups (all P>0.05). Conclusions:PVE with NBCA and GS as embolization material showed good efficacy in patients with initially unresectable HCC. The FLR growth rate and secondary hepatectomy rate of patients using NBCA were better than those of patients using GS.
5.Investigation of Intestinal Absorption Characteristics of Multi-index Components of Danggui Buxuetang Based on Drug Absorption Simulating System
Jia ZHANG ; Yuan GAO ; Xiangjie ZHOU ; Wufeng GAO ; Yue ZHOU ; Lixia MA ; Xinya ZHUANG ; Jie DONG ; Wei GU ; Guojun YAN
Chinese Journal of Experimental Traditional Medical Formulae 2022;28(16):188-195
ObjectiveTo investigate the intestinal absorption characteristics of multi-index components in Danggui Buxuetang with drug absorption simulating system (DASS) established by everted intestinal sac model. MethodThe intestinal absorption solution at different time points after administration of Danggui Buxuetang was collected and detected by high performance liquid chromatography (HPLC), acetonitrile (A)-0.2% glacial acetic acid solution (B) was used as the mobile phase for gradient elution (0-16 min, 15%-23%A; 16-20 min, 23%-28%A; 20-25 min, 28%-30%A; 25-30 min, 30%A; 30-35 min, 30%-65%A; 35-45 min, 65%-95%A), the detection wavelength was 302 nm. HPLC fingerprint of intestinal absorption solution was established and the common peak was calibrated, and the relative cumulative absorption rate of each index component was calculated. The relative cumulative absorption curves of components were fitted with various mathematical models by DDSolver 1.0 to explore the absorption law of different components. ResultThe absorption process of C2 (calycosin-7-glucoside) and C6 in Danggui Buxuetang was in line with zero-order equation, C9 was best fitted by Weibull equation, and the remaining 7 components were in line with Makoid-Banakar equation. C1 with C2, C3, C5, C7 and C10, C2 with C5 and C7, C3 with C4, C5, C7 and C10, C4 with C6 and C10, C5 with C7, C6 with C10, C7 with C10, C8 with C9 were absorbed simultaneously during the absorption process. With the prolongation of time, the overall cumulative absorption rate of Danggui Buxuetang increased. At 120 min, the overall cumulative absorption rate of Danggui Buxuetang exceeded 38%, and reached 49.14% at 180 min. ConclusionTen ingredients in Danggui Buxuetang are absorbed in the jejunum, but absorption law of various components is different, which shows that the intestinal absorption of compound preparations of traditional Chinese medicine (TCM) has multiple characteristics. Intestinal absorption study of TCM compound preparations with chemical composition as the index can reveal some of its absorption law, but it is not complete.
6. Study on the accuracy of oxygen concentration of modified oxygen treatment with Venturi and humidity system
Qiang WEI ; Bingyu QIN ; Guojun HE ; Yuanyuan WU ; Yuan SHI ; Weitao SUN ; Mengjuan JING ; Shichao ZHU ; Huanzhang SHAO
Chinese Critical Care Medicine 2018;30(7):677-680
Objective:
To verify the accuracy of oxygen concentration (FiO2) of modified oxygen treatment with Venturi and humidity system.
Methods:
Patients just after ventilator weaning and before the removal of tracheal intubation/tracheotomy tube, who admitted to the intensive care unit (ICU) of Henan Provincial People's Hospital from May 1st to December 15th in 2017, were enrolled. All patients were given a modified oxygen treatment with Venturi and humidity system, and the oxygen flow rate (Flow) of the Venturi device and the oretical value of FiO2 were adjusted according to the patient's condition. Patients were divided into five groups based on doctor's orders: Flow 3 L/min FiO2 0.24, Flow 3 L/min FiO2 0.26, Flow 6 L/min FiO2 0.28, Flow 6 L/min FiO2 0.30, Flow 9 L/min FiO2 0.35. The value of FiO2 at the inhalation end of patients of each group was measured by TSI airflow analyzer, and the consistency between the measured value of FiO2 at the inhalation end and the FiO2 marked value of Venturi was compared and analyzed.
Results:
When the FiO2 theoretical value of Venturi were adjusted to 0.24, 0.26, 0.28, 0.30, and 0.35, the measured values of FiO2 at the inhalation end of patients were 0.38±0.05, 0.38±0.05, 0.40±0.04, 0.41±0.04, and 0.77±0.11, respectively, which were all significantly higher than the theoretical value of FiO2 (all
7.The application of three-dimensional printing abdominal aortic aneurysm improve the teaching effect for the residents in vascular surgery department
Zhoupeng WU ; Ding YUAN ; Jichun ZHAO ; Yukui MA ; Bin HUANG ; Yi YANG ; Fei XIONG ; Guojun ZENG ; Xiyang CHEN ; Tiehao WANG ; Xiaojiong DU
Chinese Journal of Medical Education Research 2018;17(6):611-615
Objective To evaluate 3D printing abdominal aortic aneurysm model in analysis of clinical teaching effect for standardized resident doctors in vascular surgery department. Methods 48 resi-dents in vascular surgery department in our hospital from December 2016 to September 2017 were seleeected and randomly divided into control group and the experimental group. The traditional vascular surgical anatomy atlas, ultrasound, CT abdominal blood vessel 3D reconstruction, digital subtraction, video and so on were used by 24 residents in the control group, while in the experimental group, on the basis of the traditional teaching, abdominal aortic aneurysm model of 3D printing, true aortic coated stent delivery system were increased. After the teaching, the theory of evaluation (abdominal vascular anatomical features, morphological characteristics and classification of AAA, measurement of various parameters and key points of operation in the EVAR) and satisfaction questionnaire were adopted to evaluate the effect of two kinds of teaching methods. SPSS 19.0 was used to conduct t test on two groups of physician evaluation data. Results The results of theoretical assessment showed that there was no significant difference between the control group and the experimental group in the abdominal vascular anatomical features, the morphological features and the classification of the experimental group (P>0.05) in the examination of the common AAA cases and the complicated AAA cases. However, the experimental group was higher than the control group in the mea-surement of the parameters of EVAR, and the score of the operation points and the total score, and the difference was statistically significant (t=2.283, t=2.263, P<0.05). The results of the questionnaire showed that the students' satisfaction scores on the teaching satisfaction of the normal and complex AAA cases were better than those of the control group, and the difference was statistically significant (P<0.05). Conclusion The 3D printing model can increase the understanding and mastery of the anatomy and treat-ment of abdominal aortic aneurysm and improve its learning enthusiasm for vascular surgery. We should make full use of the advantages of 3D printing technology on the basis of retaining the advantages of tradi-tional teaching methods and means, and further enhance the teaching effect.
8.Study on the accuracy of oxygen concentration of modified oxygen treatment with Venturi and humidity system.
Qiang WEI ; Bingyu QIN ; Guojun HE ; Yuanyuan WU ; Yuan SHI ; Weitao SUN ; Mengjuan JING ; Shichao ZHU ; Huanzhang SHAO
Chinese Critical Care Medicine 2018;30(7):677-680
OBJECTIVE:
To verify the accuracy of oxygen concentration (FiO2) of modified oxygen treatment with Venturi and humidity system.
METHODS:
Patients just after ventilator weaning and before the removal of tracheal intubation/tracheotomy tube, who admitted to the intensive care unit (ICU) of Henan Provincial People's Hospital from May 1st to December 15th in 2017, were enrolled. All patients were given a modified oxygen treatment with Venturi and humidity system, and the oxygen flow rate (Flow) of the Venturi device and the oretical value of FiO2 were adjusted according to the patient's condition. Patients were divided into five groups based on doctor's orders: Flow 3 L/min FiO2 0.24, Flow 3 L/min FiO2 0.26, Flow 6 L/min FiO2 0.28, Flow 6 L/min FiO2 0.30, Flow 9 L/min FiO2 0.35. The value of FiO2 at the inhalation end of patients of each group was measured by TSI airflow analyzer, and the consistency between the measured value of FiO2 at the inhalation end and the FiO2 marked value of Venturi was compared and analyzed.
RESULTS:
When the FiO2 theoretical value of Venturi were adjusted to 0.24, 0.26, 0.28, 0.30, and 0.35, the measured values of FiO2 at the inhalation end of patients were 0.38±0.05, 0.38±0.05, 0.40±0.04, 0.41±0.04, and 0.77±0.11, respectively, which were all significantly higher than the theoretical value of FiO2 (all P < 0.01). The difference between the measured value of FiO2 at the inhalation side and the FiO2 value of the Venturi annotated and the difference rate were both "V"-shaped, both of which decreased with the increase in theoretical value of FiO2 to a Flow of 9 L/min and a theoretical value of FiO2 0.35, the accuracy was the worst, with the FiO2 difference of 0.42±0.11, and the FiO2 difference rate of (121.6±36.5)%.
CONCLUSIONS
There is a difference between the measured value and the theoretical value of FiO2 at the inhalation end of the modified Venturi oxygen therapy humidification system, which needs to be paid attention to during clinical oxygen therapy.
Humans
;
Humidity
;
Oxygen/analysis*
;
Oxygen Inhalation Therapy
;
Respiration, Artificial
;
Ventilator Weaning
9.Option of minimally invasive technique for living donor nephrectomy
Jianlin YUAN ; Geng ZHANG ; Weijun QIN ; Xiaojian YANG ; Lei YU ; Ping MENG ; Yanzhu WANG ; Guojun WU ; Rongliang QIN
Chinese Journal of Urology 2017;38(z1):49-53
Objective To discuss the optimal operation mode and operation path in minimally invasive technique for living donor nephrectomy.Methods From September 2013 to August 2015, 68 living donor nephrectomy was retrospectively reviewed. Thirty-one patients were performed with robotic-assisted laparoscopic living donor nephrectomy(robotic group), twenty-nine patients underwent totally retroperitoneal laparoscopic living donor nephrectomy(non hand assisted group),and eight patients were performed with hand assisted retroperitoneal laparoscopic living donor nephrectomy(hand assisted group). Operation time, warm ischemia time, intraoperative hemorrhage volume, hospitalization time, complications and preoperative and postoperative serum creatinine value of the recipients between the two groups were compared.Results The operations of three groups were all performed successfully. Intraoperative hemorrhage volume in the three groups were(39±15)ml,(62±37)ml and(53±19)ml, and there were significant differences between these groups(P<0.05). But hospitalization time ,operation time, warm ischemia time and complications occurred rate in the three groups had no significant difference(P>0.05). In robotic group,2 donors occurred with splenic injury during operation and 1 donor was detected with hemorrhage after operation. In non-hand assisted group, 1 donor occurred with urinary tract infection, 1 donor occurred with external iliac vein thrombosis. In hand assisted group 1 donor was detected with wound fat liquefaction after operation. All the donors were followed up for more than 9 months, no hypertension, proteinuria and renal dysfunction complications were detected. The blood creatinine in three groups of recipients after operation of 5th day and 28th day were(118±26)μmol/L, (130±33)μmol/L,(128±41)μmol/L and(114±17)μmol/L,(116±34)μmol/L,(115±29)μmol/L, respectively, and there was no statistical difference(P>0.05).Conclusions Minimally invasive technique for living donor nephrectomy is beneficial to patients' recovery. Surgery doctors should combine personal experience and the hospital's hardware conditions and other factors. The principle is to ensure the donor's safety and to balance the interests of the donor and the recipient, to choose their own most skilled way of surgery.
10.Ensemble Partial Least Squares Algorithm Based on Variable Clustering for Quantitative Infrared Spectrometric Analysis
Yiming BI ; Guohai CHU ; Jizhong WU ; Kailong YUAN ; Jian WU ; Fu LIAO ; Jun XIA ; Guangxin ZHANG ; Guojun ZHOU
Chinese Journal of Analytical Chemistry 2015;(7):1086-1091
Due to the ability of overcoming both the dimensionality and the collinear problems of the spectral data, partial least squares ( PLS ) is in ever increasingly used for quantitative spectrometric analysis, especially for near-infrared spectrum, mid-infrared spectrum and Raman spectrum. In this work, an improved PLS algorithm is proposed for efficient information extraction and noise reduction. The spectral variables are clustering to several subsets, and several sub-models are built for each subset. Then, the sub-models are re-weighted and ensemble to the final model. Experiments on two near-infrared datasets ( octane number prediction in gasoline and nicotine prediction in tobacco leafs ) demonstrate that the new method provides superior prediction performance and outperformed the conventional PLS algorithm, and the root mean square error of prediction ( RMSEP) is reduced by 32% and 22%, respectively.

Result Analysis
Print
Save
E-mail