1.Principles of managing wards for patients with internal radionuclide contamination
Fan BAI ; Chao YANG ; Lei ZHU ; Minghao LIU ; Danjie LIU ; Xiaoxin LIU ; Shanshan GUO ; Jianan WANG
Chinese Journal of Radiological Health 2025;34(3):444-449
		                        		
		                        			
		                        			Based on current national policies, regulations, standards, relevant literature, and departmental experience regarding the protection against radionuclides in China, this study provides a brief overview of key issues in the management of hospital wards for patients with internal radionuclide contamination. The discussion covers the detection of internal contamination, general requirements for internal radionuclide contamination wards, and inpatient management. In addition, the study explores in depth the daily responsibilities, protective measures, and management protocols for both healthcare staff and patients within such wards. This article summarizes a framework for the construction of internal radionuclide contamination wards, along with specific plans and detailed role-based guidelines. These results provide a reference for the management of hospital wards for patients with internal radionuclide contamination.
		                        		
		                        		
		                        		
		                        	
2.Development of a new type of detection window protective device for surface contamination monitor
Lei ZHU ; Minghao LIU ; Shanshan GUO ; Fan BAI ; Chao YANG ; Tao YAN
China Medical Equipment 2024;21(3):144-147,173
		                        		
		                        			
		                        			Objective:To develop a new type of detection window protective device for surface contamination monitor,and to verify its testing effect.Methods:The new type of surface contamination monitor detection window protection device was composed of the protective film and fixed frame,which was of integrated design and one-off production.The protective film was made of transparent flat Myra film,thickness≤2.5μm,the fixed frame was a rectangular hollow structure surrounded by four edges and provided with a working surface and a mounting surface.The protective film was pasted on the inner wall of the working surface of the fixed frame by adhesive,and the protective film and fixed frame were installed on the outside of the detection window of the surface contamination monitor by means of fixing buckles.Two commonly used surface contamination detection instruments,RDa150 and Como170,were selected to measure artificial radiation sources under three protection states:no film protection,plastic wrap protection and new protection device to test the detection efficiency and operability of the new surface contamination monitor's detection window protection device.Results:Compared with the traditional protective measures of plastic wrap,the detection efficiency of α,β and γ rays was more effectively ensured by the new detection window protective device for surface contamination monitor,and the detection efficiency of α rays was increased from about 40%to about 70%.Conclusion:The new detection window protection device for surface contamination monitor can significantly improve the detection efficiency of radioactive contamination,especially alpha-ray pollution,and effectively protect the instrument and equipment,and effectively improve the detection efficiency of surface contamination detection operators.
		                        		
		                        		
		                        		
		                        	
3.Experts consensus on standard items of the cohort construction and quality control of temporomandibular joint diseases (2024)
Min HU ; Chi YANG ; Huawei LIU ; Haixia LU ; Chen YAO ; Qiufei XIE ; Yongjin CHEN ; Kaiyuan FU ; Bing FANG ; Songsong ZHU ; Qing ZHOU ; Zhiye CHEN ; Yaomin ZHU ; Qingbin ZHANG ; Ying YAN ; Xing LONG ; Zhiyong LI ; Yehua GAN ; Shibin YU ; Yuxing BAI ; Yi ZHANG ; Yanyi WANG ; Jie LEI ; Yong CHENG ; Changkui LIU ; Ye CAO ; Dongmei HE ; Ning WEN ; Shanyong ZHANG ; Minjie CHEN ; Guoliang JIAO ; Xinhua LIU ; Hua JIANG ; Yang HE ; Pei SHEN ; Haitao HUANG ; Yongfeng LI ; Jisi ZHENG ; Jing GUO ; Lisheng ZHAO ; Laiqing XU
Chinese Journal of Stomatology 2024;59(10):977-987
		                        		
		                        			
		                        			Temporomandibular joint (TMJ) diseases are common clinical conditions. The number of patients with TMJ diseases is large, and the etiology, epidemiology, disease spectrum, and treatment of the disease remain controversial and unknown. To understand and master the current situation of the occurrence, development and prevention of TMJ diseases, as well as to identify the patterns in etiology, incidence, drug sensitivity, and prognosis is crucial for alleviating patients′suffering.This will facilitate in-depth medical research, effective disease prevention measures, and the formulation of corresponding health policies. Cohort construction and research has an irreplaceable role in precise disease prevention and significant improvement in diagnosis and treatment levels. Large-scale cohort studies are needed to explore the relationship between potential risk factors and outcomes of TMJ diseases, and to observe disease prognoses through long-term follw-ups. The consensus aims to establish a standard conceptual frame work for a cohort study on patients with TMJ disease while providing ideas for cohort data standards to this condition. TMJ disease cohort data consists of both common data standards applicable to all specific disease cohorts as well as disease-specific data standards. Common data were available for each specific disease cohort. By integrating different cohort research resources, standard problems or study variables can be unified. Long-term follow-up can be performed using consistent definitions and criteria across different projects for better core data collection. It is hoped that this consensus will be facilitate the development cohort studies of TMJ diseases.
		                        		
		                        		
		                        		
		                        	
4.Research on the Improvement of Ferroptosis and Cognitive Function Impairment in APP/PS1 Alzheimer's Mice by Bingchan-gsan via the Nrf2/HO-1 Signaling Pathway
Shaobo GUO ; Wenhui ZHU ; Yu BAI ; Biao ZHANG
Journal of Nanjing University of Traditional Chinese Medicine 2024;40(6):598-607
		                        		
		                        			
		                        			OBJECTIVE To explore whether inhaling Bingchangsan(BCS can modulate the Nrf2/HO-1 signaling pathway to improve ferroptosis and cognitive dysfunction in Alzheimer's Disease(AD mouse models.METHODS 30 APP/PS1 mice were ran-domly divided into three groups:a model group(APP/PS1 group,a low-dose Bingchangsan group(BCS-L group,and a high-dose Bingchangsan group(BCS-H group.10 age-matched wild-type(WT mice were used as a control group.The WT group and the APP/PS1 group were treated with nebulized pure water,while the BCS-L group received 0.5μL of Bingchangsan inhalation solution per day,and the BCS-H group received 1μL,both administered via nebulization for 10 min daily for 2 weeks.2 weeks post-treat-ment,spatial cognitive abilities of the mice were assessed using the Morris water maze test.Following the water maze experiment,the mice were euthanized,and their brain tissues were collected for Aβ1-42 immunofluorescence,P-tau immunohistochemistry,and Nissl staining.Hippocampal tissues were extracted for Western blot and qPCR analysis to measure the protein and mRNA expression levels of Keap1,Nrf2,HO-1,GPX4,SCL7A11,TFRC,DMT1,FTL,and FTH1.Additionally,brain tissues were used for glutathione(GSH content measurement using a GSH assay kit.RESULTS In the BCS groups,the latency period for escape shortened,and the time spent in the quadrant with the platform,as well as the number of times crossing the platform,increased.Compared to the APP/PS1 group,the expression levels of Aβ1-42 and P-tau in the hippocampal CA1 region and cortex of mice in the BCS groups were signifi-cantly reduced(P<0.05,P<0.01.Nissl staining revealed a denser arrangement of neurons with more Nissl bodies in the BCS groups.In the hippocampal tissue,compared to untreated APP/PS1 mice,significant increases in the protein and mRNA levels of Nrf2,HO-1,SLC7A11,GPX4,and FTL were observed in all BCS groups(P<0.05,P<0.01.While the BCS-L group showed in-creased levels of FTH1 protein and mRNA,these changes were not statistically significant.Furthermore,the expression levels of TFRC,DMT1,and Keap1 were significantly downregulated in the BCS groups(P<0.05,P<0.01.Additionally,treatment with BCS effectively restored the glutathione(GSH content in the brain(P<0.01.CONCLUSION Inhalation of BCS can improve cognitive dysfunction in APP/PS1 mice.BCS activates the Nrf2/HO-1 pathway,increases the expression of GPX4,and enhances Nrf2 tran-scriptional activity by inhibiting Keap1.This leads to an upregulation of SLC7A11 and restoration of GSH levels,effectively countering ferroptosis.Additionally,BCS effectively inhibits TFRC and DMT1,while upregulating FTL and FTH1 expression,thereby maintaining intracellular iron homeostasis.This contributes to mitigating the impact of ferroptosis on APP/PS1 mice,subsequently enhancing their cognitive functions.
		                        		
		                        		
		                        		
		                        	
5.Clinical Efficacy of Maiwei Yangfei Decoction in the Treatment of Idiopathic Pulmonary Fibrosis of Qi-Yin Deficiency Type
Dongwei ZHU ; Qi ZHAO ; Le BAI ; Tingyu PAN ; Jing WANG ; Shenhao GUO ; Yong XU ; Xianmei ZHOU
Journal of Nanjing University of Traditional Chinese Medicine 2024;40(9):962-969
		                        		
		                        			
		                        			OBJECTIVE To explore the therapeutic effect and safety of Maiwei Yangfei Decoction(MWYF)in the treatment of idiopathic pulmonary fibrosis of qi-yin deficiency type.METHODS A total of 58 patients with idiopathic pulmonary fibrosis of qi-yin deficiency type were randomly divided into an experimental group and a control group with 29 cases in each group according to a 1:1 ratio.Two cases dropped out of the experimental group and three cases dropped out of the control group.The control group received standardized treatment of Western medicine,and the experimental group received MWYF on the basis of the treatment of the control group.The treatment course of both groups was 3 months.The TCM syndrome score,lung function,6-minute walking distance(6MWD),transcutaneous blood oxygen saturation(SpO2),high-resolution computed tomography(HRCT)score,St.George's respir-atory questionnaire(SGRQ)score and serum sialoglycoprotein antigen(KL-6)level of the two groups were compared before and after treatment.Blood routine and liver and kidney function of the two groups were detected before and after treatment,and the occurrence of adverse reactions during treatment was recorded.RESULTS After treatment,the total score of TCM syndrome of the two groups was significantly improved(P<0.01),and the experimental group was better than the control group(P<0.01);the DLCO%of the experi-mental group increased(P<0.05),and the experimental group was higher than the control group(P<0.05).The experimental group showed significant improvement in 6MWD,HRCT grid shadow,SGRQ symptom score and total score,and serum KL-6 level(P<0.05,P<0.01),which was better than the control group(P<0.05,P<0.01).No serious adverse events occurred in either group dur-ing the treatment.CONCLUSION MWYF combined with standardized Western medicine treatment can effectively improve the clini-cal symptoms of patients with idiopathic pulmonary fibrosis of qi-yin deficiency type,reduce the expression level of serum KL-6,and has a definite effect and good safety.
		                        		
		                        		
		                        		
		                        	
6.Research progress on the application of membrane biomimetic nanocarriers in targeted therapy of lung diseases
Wen-jing BAI ; Rong GUO ; Lin XIONG ; Leng-jing ZHU ; Jia-xin LI ; Ya-shi WANG ; Man LI ; Qin HE
Acta Pharmaceutica Sinica 2024;59(10):2730-2740
		                        		
		                        			
		                        			 Pulmonary disease is one of the major threats to human health. However, the current clinical treatment drugs for lung diseases generally have problems such as low lung delivery efficiency, fast clearance rate and obvious toxic side effects. Recently, membrane biomimetic nanocarriers have attracted more and more attention. Due to their advantages of high targeting, long cycle time, good biocompatibility and strong immune escape ability, membrane biomimetic nanocarriers have become a major research hotspot in targeted therapy of lung diseases. In this review, we discuss the main preparation methods of membrane biomimetic nanoparticles, the characteristics of membrane biomimetic nanocarriers from different cell sources and their application in the targeted therapy of lung diseases. At the same time, according to the characteristics of different membranes, the shortcomings, current technical limitations and future prospects are discussed. This review is expected to provide references for the design of membrane biomimetic nanocarriers and their potential applications in the treatment of lung diseases. 
		                        		
		                        		
		                        		
		                        	
7.Clinical correlation between TNFRSF12A and hepatocellular carcinoma and its effect on immunoregulation of tumor cells
Jie ZHU ; Pei-Qi FANG ; Bai-Shen PAN ; Wei GUO ; Bei-Li WANG
Fudan University Journal of Medical Sciences 2024;51(3):368-377
		                        		
		                        			
		                        			Objective To investigate the role of the TNFRSF12A molecule in the pathogenesis of liver cancer.Methods Through comprehensive analysis of the Cancer Genome Atlas Program(TCGA)database and single-cell sequencing data,we studied the expression of TNFRSF12A in liver cancer and its correlation with prognosis.HPA database was utilized to analyze the subcellular localization of TNFRSF12A,and GO and KEGG analyses were performed by DAVID.TIME 2.0 was employed to analyze the correlation between TNFRSF12A and immune cell infiltration in liver cancer tissues.Results TNFRSF12A was found to be highly expressed in liver cancer tissues,significantly correlating with patient survival prognosis(OS:HR=1.61,P=0.007 0;RFS:HR=1.45,P=0.037 0;PFS:HR=1.30,P=0.099 0;DSS:HR=1.67,P=0.027 0),as well as age(P=0.046 7)and BCLC stage(P=0.045 6).TNFRSF12A co-expressed with tumor stem cell markers(CD24,SOX4,ANPEP),indicating a strong link to malignancy.Furthermore,molecular functional analysis unveiled that IL-2R primarily existed in the cell cytoplasm and played a role in processes such as cell apoptosis,invasion,and protein binding.Moreover,TNFRSF12A was associated with Treg cells and immune cell infiltration,further suggesting its role in tumor immune regulation.Conclusion TNFRSF12A exhibits a significant elevation within liver tumors and shows a notable correlation with patients'prognosis.Tumor cells engage in interactions with cytokines produced by Tregs,thereby reshaping the tumor microenvironment.The potential clinical significance of TNFRSF12A as a prognostic marker for tumors holds promise in offering novel avenues for personalized treatment and prognosis prediction.
		                        		
		                        		
		                        		
		                        	
8.Localization and anatomical measurement of lateral compression Ⅱscrew guide needle insertion point for pelvic fracture
Yong-Zheng CHEN ; Zhen-Hua HU ; Shao-Juan LI ; Xia-Cun LIANG ; Li-Kang HOU ; Shu-Liang ZHU ; Xin-Ying BAI ; Jin-Jian HE ; De-Meng YANG ; Zhi-Guo CHEN
Acta Anatomica Sinica 2024;55(6):728-733
		                        		
		                        			
		                        			Objective To measure the distance between the lateral compression Ⅱ(LC-Ⅱ)screw guide needle and the surrounding important structures around the anterior inferior iliac spine in pelvic fractures and to locate the needle point,so as to provide anatomical reference for clinical nail placement.Methods Totally 40 adult gross specimens of embalming were implanted with LC-Ⅱ screw guide needle under the surveillance of C-arm machine,and the specimens were dissected.The shortest distance between the insertion point and the lateral femoral cutaneous nerve,femoral nerve,femoral artery,femoral vein,anterior superior iliac spine and inguinal ligament was measured.The triangle was constructed between the insertion point,anterior superior iliac spine and inguinal ligament,and the exact location of the entry point was calculated.Results The average distance between the insertion point of the male needle and the femoral vein was(50.67±7.29)mm>the anterior superior iliac spine(43.83±7.58)mm>the femoral artery(38.35±6.63)mm>the femoral nerve(31.17±1.67)mm=the inguinal ligament(28.69±6.59)mm>the lateral femoral cutaneous nerve(7.98±3.81)mm.The mean distance between the insertion point of the female needle and the anterior superior iliac spine was(45.28±7.07)mm=femoral vein(43.72±6.89)mm>femoral artery(33.76±6.33)mm>femoral nerve(25.66±6.46)mm=inguinal ligament(23.22±5.00)mm>lateral femoral cutaneous nerve(8.97±4.76)mm.The projection distance of the entry point was 31.77 mm for men and 38.41 mm for women.The Angle b was 42.81°for men and 31.71° for women.Conclusion The lateral femoral cutaneous nerve is most vulnerable to injury when LC-Ⅱ screw is inserted,and the risk of injury has nothing to do with sex.The insertion point positioning method a and b made LC-Ⅱ screw placement quickly,safely and accurately,and reduced fluoroscopy time and frequency.
		                        		
		                        		
		                        		
		                        	
9.Clinical efficacy of ultrasound-guided spinal nerve block and paraverteral nerve block in treating postherpetic neuralgia
Kai ZHANG ; Jiangang LUO ; Xiaoye ZHU ; Mengqi LI ; Zhigang CHENG ; Fei REN ; Nianyue BAI ; Yunjiao WANG ; Qulian GUO
Journal of Chinese Physician 2024;26(9):1308-1312
		                        		
		                        			
		                        			Objective:To compare the clinical efficacy of ultrasound-guided spinal nerve block (SNB) and paraverteral nerve block (PVB) in treating postherpetic neuralgia.Methods:A total of 52 patients with postherpetic neuralgia who visited the Pain Clinic of the Xiangya Hospital, Central South University from February 2020 to December 2022 were selected and randomly divided into an ultrasound-guided SNB group and a PVB group using a random number table method, with 26 patients in each group. Patients in the SNB group received ultrasound-guided spinal nerve block therapy; The PVB group received ultrasound-guided paraverteral nerve block treatment. Visual Analog Scale (VAS) scores, 36-Item Short Form Survey (SF-36) scores, and total effective rate were observed in two groups of patients before treatment, 2 weeks after treatment, 1 month after treatment, 3 months after treatment, and 6 months after treatment. Complications during treatment were also observed.Results:The total effective rates of SNB group patients at 1, 3, and 6 months after treatment were significantly higher than those of PVB group (all P<0.05). After treatment, the VAS scores of both groups of patients at each time point were significantly reduced compared to before treatment (all P<0.05); The VAS scores of patients in the SNB group were lower than those in the PVB group at 1, 3, and 6 months after treatment, but the difference was not statistically significant (all P>0.05). There was no statistically significant difference in Physical Component Summary (PCS) and Mental Component Summary (MCS) scores between SNB and PVB groups before nerve block treatment (all P>0.05). The MCS and PCS scores of the two groups of patients were significantly higher than before treatment at 2 weeks, 1 month, 3 months, and 6 months after treatment (all P<0.05). The MCS scores of the SNB group were significantly higher than those of the PVB group at 2 weeks, 1 month, 3 months, and 6 months after treatment (all P<0.05), but there was no statistically significant difference in PCS scores between the two groups (all P>0.05). Both groups of patients did not experience any serious complications related to the treatment in this study during the follow-up period. Conclusions:Both ultrasound-guided spinal nerve block and paraverteral nerve block can safely and effectively treat postherpetic neuralgia. The clinical effect of ultrasound-guided spinal nerve block in treating postherpetic neuralgia is better than that of paraverteral nerve block.
		                        		
		                        		
		                        		
		                        	
10.Development of a new type of detection window protection device for wound contamination detector
Lei ZHU ; Shanshan GUO ; Fan BAI ; Minghao LIU ; Chao YANG ; Tao YAN
China Medical Equipment 2024;21(9):168-170,177
		                        		
		                        			
		                        			In order to maximize the detection efficiency of the surface contamination detector on α rays and make up for the problems of insufficient protective measures of the detector,a new detection window protection device for wound contamination detector was designed.The device was consisted of a protective film and a fixed frame sleeve.The protective film was made of a transparent flat Mylar film with a thickness of≤2.5 μm and a circular shape.Its diameter matched the detection surface diameter of the wound radiation measuring instrument probe and can be used in combination with the appropriate model of wound radiation measuring instrument probe.The sleeve was provided with a closed end and an open end,the protective film was fixed on the inner side of the closed end of the sleeve,and the open end of the sleeve was provided with an annular fixing buckle,so that the sleeve can be firmly installed on the probe of the disposable wound radiation measuring instrument.After installation,the protective film can be closely attached to the detection surface of the probe of the wound radiation measuring instrument.Two commonly used contamination detectors were selected to measure the artificial radioactive sources under three protection conditions:film-free protection,plastic wrap protection and new protective devices,and the detection efficiency and operability of the detection window protection device of the new wound contamination detector were tested.The results showed that compared with the traditional protective measures of plastic wrap,the new device can significantly improve the detection efficiency of wound radioactive contamination,especially α contamination,and effectively protect the instrument and equipment,and improve the detection efficiency of wound pollution operators.
		                        		
		                        		
		                        		
		                        	
            