1.Research Advance on Smartphone-based Visual Biosensor in Point-of-Care Testing
Xian-Xin XIANG ; Hua-Yue SUN ; Hui-Ning CHAI ; Kun YU ; Li-Jun QU ; Guang-Yao ZHANG ; Xue-Ji ZHANG
Chinese Journal of Analytical Chemistry 2024;52(2):145-156
Human physiological indicators have become an important standard for assessing health in modern society.Traditional detection methods often require a separate laboratory,complex operation process and long detection time,so it is urgent to develop portable,fast and accurate on-site detection technologies for bioanalysis.Point-of-care testing(POCT),which differs from traditional laboratory testing,can realize the rapid in situ detection of biomarkers without the complicated analytical process of the laboratory.Smartphones,which are an essential tool in our daily life,not only have independent operating systems and built-in storage functions,but also have high-definition cameras,which have great application potential in POCT visualization.The combination of various biosensing technologies and smartphones has developed into a new direction in the field of POCT.This review mainly introduced the research progress of smartphone-based visual biosensors in POCT in recent years,including colorimetric sensors,fluorescence sensors,chemiluminescence sensors and electrochemiluminescence sensors.Finally,the problems faced by smart-phone-based visual biosensors in the application of POCT were summarized,and their future development was prospected.
2.Seven thyroid imaging reporting and data systems for differentiating benign and malignant thyroid nodules under the context of Hashimoto thyroiditis
Xin SUN ; Wei ZHANG ; Linggang CHENG ; Yang GUANG ; Yukang ZHANG
Chinese Journal of Medical Imaging Technology 2024;40(2):212-216
Objective To compare the value of 7 different thyroid imaging reporting and data systems(TI-RADS)for differentiating benign and malignant thyroid nodules under the context of Hashimoto thyroiditis(HT).Methods A total of 338 thyroid nodules in 200 HT patients were enrolled,including 167 benign and 171 malignant ones.Kwak-TIRADS,American Thyroid Association(ATA)guideline,American Association of Clinical Endocrinologists(A ACE)/American College of Endocrinology(ACE)/Associazione Medici Endocrinologi(AME)guideline,K-TIRADS of Korean Society of Thyroid Radiology,EU-TIRADS of European Thyroid Association,American College of Radiology(ACR)-TIRADS and 2020 Chinese guidelines for malignant risk stratification of thyroid nodules by ultrasound proposed by the superficial organs and vessels group of the ultrasound medicine branch of the Chinese Medical Association(C-TIRADS)were used for grading of benign and malignant thyroid nodules.Taken pathological results as gold standards,the diagnostic efficacy of 7 kinds of TI-RADS were analyzed.Results The sensitivity of Kwak-TIRADS,ATA guideline,A ACE/ACE/AME guideline,K-TIRADS,EU-TIRADS,ACR-TIRADS and C-TIRADS for differentiating benign and malignant thyroid nodules under the context of HT was 97.08%,98.25%,99.42%,95.91%,99.42%,90.06%and 99.42%,respectively,the specificity was 88.02%,83.23%,82.04%,88.02%,82.04%,86.83%and 84.43%,respectively,and the area under the curve(AUC)was 0.946,0.913,0.907,0.934,0.909,0.916 and 0.960,respectively.The sensitivity of C-TIRADS,EU-TIRADS and A ACE/ACE/AME guideline were all higher than that of K-TIRADS and ACR-TIRADS(all P<0.05),and the specificity of Kawk-TIRADS and K-TIRADS were both higher than that of C-TIRADS,ATA guideline,EU-TIRADS and AACE/ACE/AME guideline(all P<0.05),while AUC of C-TIRADS and Kawk-TIRADS were both higher than that of the rest 5 kinds of TI-RADS(all P<0.05).According to Kwak-TIRADS,ATA guideline,AACE/ACE/AME guideline,K-TIRADS,EU-TIRADS,ACR-TIRADS and C-TIRADS,the malignant rate of different grades nodules identified with the same TI-RADS were significant different(all P<0.05),which all raised with the increase of TI-RADS grade.Conclusion C-TIRADS and Kawk-TIRADS had better value for differentiating benign and malignant thyroid nodules under the context of HT,among which C-TIRADS had higher sensitivity and Kawk-TIRADS had higher specificity.
3.Effectiveness and perioperative managements of unilateral adrenalectomy as surgical treatment in curing primary bilateral macronodular adrenal hyperplasia
Chen FANG ; Jun DAI ; Wei HE ; Xin HUANG ; Danfeng XU ; Tingwei SU ; Guang NING ; Weiqing WANG ; Fukang SUN
Chinese Journal of Urology 2024;45(4):271-275
Objective:To evaluate the efficacy and safety of unilateral adrenalectomy for treating primary bilateral macronodular adrenal hyperplasia (PBMAH) of different clinical types.Methods:The clinical and biochemical data of 54 patients with PBMAH who underwent unilateral adrenalectomy from May 2008 to March 2023 were retrospectively collected. Preoperative CT images of all patients showed enlarged bilateral adrenal glands with multiple nodules of " fused masses". Mean preoperative blood cortisol concentration at 8am was (21.5±7.7)μg/dl, urinary free cortisol concentration was (442.6±300.4)μg/24h, and mean 8am ACTH concentration was (6.4±2.3)pg/ml. Postoperative symptoms, BMI, blood pressure, mass diameter, cortisol and ACTH concentration were recorded and analyzed.Results:Compared with ordinary laparoscopic surgery, robot-assisted surgery showed shorter operation time [(115.4±22.1)min vs.(95.0±19.8)min, P=0.045]; less blood loss [(118.2±57.0)ml vs. (125.6±45.3)ml, P=0.441] and shorter hospitalization time [(5.2±0.9)day vs. (6.4±1.2)day, P=0.279]. Compared with laparoscopic surgery, open surgery showed longer operation time [(134 34.5) min vs. (104.3±20.1) min, P=0.035]; more blood loss [(305.5±85.2) ml vs. (122.5±44.3) ml, P=0.012] and longer hospitalization time[(10.4±3.2)day vs. (5.7±1.0) day, P=0.020]. The average follow-up time was (23.7±11.7) months. Sixteen cases biochemically relapsed, and the average relapse-free time was (25.4±13.4) month. Mean postoperative systolic blood pressure was (131.1±16.8)mmHg ( P=0.001) while diastolic blood pressure decreased to (82.2±11.1)mmHg ( P=0.002). Postsurgical average blood cortisol concentration decreased to (10.2±4.0)μg/dl ( P<0.01), while urine cortisol concentration decreased to (106.6±43.4)μg/24h( P<0.01). Average ACTH concentration increased to (12.6±4.1)pg/ml( P=0.005). Recurrent patients had higher preoperative blood and urine cortisol concentration(24.7±8.2)μg/dl( P=0.046), (522.8±234.2)μg/24h( P=0.028), and all of them underwent contralateral adrenalectomy. Conclusions:Unilateral adrenalectomy is safe and effective for treatment of PBMAH while part of patients biochemically relapsed. Subclinical patients were observed no recurrent cases after surgery. Recurrent patients have higher preoperative blood and urine cortisol levels and should undertake contralateral adrenalectomy and supplement corticosteroids for whole life.
4.Diagnostic value of serum ferritin in intestinal failure-associated liver disease
Guang-Ming SUN ; Yu-Fei XIA ; Long-Chang HUANG ; Gulisudumu MAITIABULA ; Li ZHANG ; Xue-Jin GAO ; Xin-Ying WANG
Parenteral & Enteral Nutrition 2024;31(3):147-153
Objective:To investigate the diagnostic value of serum ferritin in intestinal failure-associated liver disease. Methods:Clinical data of adult patients with short bowel syndrome admitted to the Department of General Surgery of Jinling Hospital affiliated to Nanjing University from January 2019 to December 2022 were retrospectively analyzed to determine the correlation between serum ferritin and liver enzyme profiles by linear regression,to screen the potential risk factors of liver injury by multifactorial Logistic regression analysis,and to establish a prediction model for liver fibrosis. The area under the curve was also calculated to assess the accuracy of the model. Results:A total of 106 patients with short bowel syndrome were included,of whom 55 (51.9%) had elevated serum ferritin (SF). Linear regression analysis showed a positive correlation between serum ferritin and ALT (r=0.427,P<0.001),ALP (r=0.365,P<0.001),and γ-GT (r=0.423,P<0.001),and one-way Logistic regression analysis showed that the higher the level of serum ferritin,the more pronounced the difference was (SF>ULN) The one-way logistic regression analysis showed that the higher the serum ferritin level,the more significant the difference was[SF>ULN (upper limit of normal value of serum ferritin),P=0.033;SF>1.5×ULN,P=0.018;SF>2.5×ULN,P=0.006]. Multifactorial logistic regression analysis showed that PN dependence (OR=3.366,P=0.017) and serum ferritin>2.5 ULN (OR=3.292,P=0.014)were independent risk factors for intestinal failure-associated liver disease-liver fibrosis,and the receiver operating curve (ROC) of the subjects showed area under the curve of 74.8%,95% CI:0.652~0.844. Conclusion:Serum ferritin can be used as a reliable clinical biomarker to help identify intestinal failure-associated liver disease.
5.Development of Pre-treatment Methods for Analysis of Different Oxidation States of Antimony Isotopes Based on Chromatographic Separation
Shi HAN ; Guang-Yi SUN ; Xin-Yu LI ; Xin-Bin FENG
Chinese Journal of Analytical Chemistry 2024;52(10):1536-1543
Antimony is a toxic metalloid and exhibits different geochemical properties in different valence states,leading to distinct migration,transformation,and behavioral patterns in the environment.To further study the transfer and source-sink relationship of antimony and its compounds in the earth's surface ecological environment,it is very important to accurately determine the isotopic composition of antimony with different speciations.In this study,a pretreatment method for chromatographic separation and determination of different speciation's antimony isotopes in water samples was established by using multi-collector inductively coupled plasma mass spectrometry(MC-ICP-MS)to measure the isotopic composition of different speciation's antimony.This method was successfully applied to detection of natural rainwater and groundwater samples from the Qilong mining area.During the pretreatment,5 mmol/L ethylenediaminetetraacetic acid dipotassium salt(EDTA)and 2 mmol/L potassium hydrogen phthalate(KHP)(pH 4.5)were used as mobile phase,successfully separating trivalent antimony(Sb(Ⅲ))and pentavalent antimony(Sb(Ⅴ))from water samples using a Hamilton PRP-X100 anion exchange chromatographic column.A series of single-factor experiments identified the optimal separation and determination conditions as a column temperature of 40 ℃ and a high-performance liquid pump flow rate of 1.5 mL/min.The recoveries of Sb(Ⅲ)and Sb(Ⅴ)from the standard solutions of Sb(Ⅲ)and Sb(Ⅴ),and the mixed oxidation states solutions were 99%±1%,103%±1%,106%±1%,and 101%±1%,respectively.Moreover,the isotopic compositions of different speciation's antimony remained consistent before and after the chromatographic column treatment,and the reliability of the method was verified by detecting different oxidation state antimony in the natural rainwater samples.This research might provide important technical support for further studies on the geochemical cycling of antimony and its compounds in the ecological environment of the Earth's surface.
6.Application of smart responsive materials in the precise repair of osteonecrosis of the femoral head
Hao CHEN ; Hong-Zhong XI ; Peng XUE ; Shuai HE ; Xiao-Xue TAN ; Guang-Quan SUN ; Xin LIU ; Xiao-Hong JIANG ; Bin DU
Medical Journal of Chinese People's Liberation Army 2024;49(7):841-847
Osteonecrosis of the femoral head(ONFH)is a common orthopedic disease,and hip preservation surgery has high clinical value in the early stages of ONFH,especially for young and middle-aged patients.However,the repair of ONFH is heterogeneous,leading to inter-individual variations in the efficacy of hip preservation.Currently,the existing tissue-engineered scaffolds in the field of hip preservation are uncontrollable after implantation,making it difficult to achieve precise repair.Smart responsive materials have good biocompatibility and self-feedback capability.By combining them with therapeutic drugs to construct stimulus-responsive drug delivery systems,new possibilities are provided for the precise repair of ONFH.This paper reviews the research progress of smart responsive materials at home and abroad.Based on the response principles of various materials and the repair characteristics of ONFH,the application prospects of various smart responsive materials such as reactive oxygen species-responsive,fluid shear stress-responsive,and light/magnetic-responsive materials are discussed and prospected in the field of precise repair for ONFH,providing new ideas for the precise treatment of ONFH.
7.Correlations of clinical,multi-modal ultrasonic and pathological features of papillary thyroid carcinoma with BRAF V600E mutation
Xin SUN ; Wei ZHANG ; Linggang CHENG ; Yang GUANG ; Yukang ZHANG
Chinese Journal of Medical Imaging Technology 2024;40(5):730-734
Objective To observe the correlations of clinical,multi-modal ultrasonic and pathological features of papillary thyroid carcinoma(PTC)with BRAF V600E mutation.Methods Patients with clinically suspected malignant thyroid lesions were prospectively collected.After the results of pathology and gene test were obtained,PTC patients were divided into BRAF V600E mutation(+)(mutant group)and BRAF V600E mutation(-)(wild-type group)according to BRAF V600E gene test.Univariate analysis and multivariate logistic regression were used to compare clinical,conventional ultrasound,contrast-enhanced ultrasound(CEUS)and pathological manifestations between groups,so as to screen the independent risk factors of PTC BRAF V600E gene mutation.Results A total of 116 PTC patients(116 lesions)were enrolled,including 77 in mutant group and 39 in wild-type group.Statistical differences of thyroid peroxidase antibody(TPO-Ab)level,lesion size,orientation,margin and microcalcification observed on conventional ultrasound,changes of lesion size and the mean transit time(MTT)shown on CEUS,as well as of extramembranous invasion,cervical central lymph node metastasis,complicated with benign nodules shown by pathology were found between groups(all P<0.05).TPO-Ab level,lesion orientation and changes of lesion size after enhancement shown by multi-modal ultrasound,and pathological cervical central lymph node metastasis were all independent predictive factors for PTC BRAF V600E gene mutation(OR=0.175,3.868,5.769,6.943,all P<0.05).Conclusion Patients'TPO-Ab level,lesion orientation,changes of lesion size after enhancement shown by multi-modal ultrasound and pathological cervical central lymph node metastasis were all independently associated with PTC BRAF V600E gene mutation.
8.Early identification and influencing factors of post-traumatic stress disorder in high-stress rescue workers.
Heng Yu LUAN ; Qiong Xuan LI ; Xin ZHANG ; Ru Fang GONG ; Xiao Guang LU ; Dong Yao LI ; Yuan Yuan SUN ; Qiao CHEN ; Feng GAO ; Xiao Yong SAI
Chinese Journal of Preventive Medicine 2023;57(7):1032-1039
Objective: To explore the risk intensity and related influencing factors of post-traumatic stress disorder (PTSD) among high-stress rescue workers, and to provide effective tools for the risk assessment of PTSD in military rescue workers. Method: From June to August 2022, cluster sampling was used to select the high-stress rescue personnel of an Army department as the survey subjects. The acute Stress reaction (ASD) scale and PTSD checklist were used to evaluate the risk of PTSD in military rescue personnel. Multivariate logistic regression were used to analyze the influencing factors of PTSD. Results: The age of 4 460 subjects was (24.38±4.072) years old, including 4 396 males (98.6%). The positive rate of initial screening for ASD was 2.85% (127/4 460). The positive rate of PTSD was 0.67% (30/4 460). Multivariate logistic regression model analysis showed that female, older age, recent trauma exposure history, passive smoking and alcohol consumption were at higher risk of ASD, the values of OR (95%CI) were 4.183 (1.819-9.618), 6.278 (1.363-28.912), 3.094 (1.500-6.379), 2.059 (1.298-3.267) and 2.607 (1.614-4.211), respectively; Lower education level was associated with lower risk of ASD, OR (95%CI) was 0.593 (0.359-0.978); People who are older, thinner, have a history of mental illness, and drink alcohol were at higher risk for PTSD, the values of OR (95%CI) were 20.144 (2.459-165.043), 10.287 (2.218-47.700), 91.104 (8.592-965.980) and 2.866 (1.144-7.180), respectively. Conclusion: Gender, age, education level, passive smoking, alcohol consumption, past history of mental illness and body mass index may be related to the potential risk of PTSD in rescue workers,passive smoking, alcohol consumption, and weight controlling should be focused on to reduce potential risks of PTSD.
Male
;
Humans
;
Female
;
Young Adult
;
Adult
;
Stress Disorders, Post-Traumatic/prevention & control*
;
Tobacco Smoke Pollution
;
Risk Assessment
;
Military Personnel
;
Alcohol Drinking
9.Effect of acupuncture exercise therapy synchronizing isokinetic muscle strength training for postoperative rehabilitation of meniscectomy under arthroscopy.
Shu-Yi CUI ; Jun-Hui WANG ; Jia-Xin ZHAO ; Jia-Yan LIANG ; Guang-Tian LIU ; Wen YAN
Chinese Acupuncture & Moxibustion 2023;43(10):1118-1122
OBJECTIVE:
To observe the effect of acupuncture exercise therapy synchronizing isokinetic muscle strength training on the motor function, stability and proprioception of knee joint, as well as the anxiety emotion in patients after meniscectomy under arthroscopy.
METHODS:
A total of 70 patients after meniscectomy under arthroscopy were randomized into an observation group (35 cases, 2 cases were eliminated, 2 cases dropped off) and a control group (35 cases, 2 cases were eliminated, 1 case dropped off). Acupuncture was applied at Chize (LU 5), Neixiyan (EX-LE 4), Dubi (ST 35),Yanglingquan (GB 34), etc. on the affective side in the two groups. After 30 min, the needles of the knee joint area were withdrew, while the needle at elbow was continuously retained, the observation group was given acupuncture exercise therapy synchronizing isokinetic muscle strength training, and the control group was given conventional acupuncture exercise therapy. The treatment was given once a day, 7-day treatment was taken as one course, and totally 4 courses were required in the two groups. Before and after treatment, the knee joint Lysholm score, the knee joint isokinetic muscle strength flexion/extension ratio (H/Q), joint position sense measurement (JPS) and Hamilton anxiety scale (HAMA) score were compared in the two groups.
RESULTS:
After treatment, the knee joint Lysholm scores and H/Q were increased compared with those before treatment in the two groups (P<0.001), and the knee joint Lysholm score and H/Q in the observation group were higher than those in the control group (P<0.001); the JPS and HAMA scores were decreased compared with those before treatment in the two groups (P<0.001), the JPS and HAMA score in the observation group were lower than those in the control group (P<0.05).
CONCLUSION
Acupuncture exercise therapy synchronizing isokinetic muscle strength training can effectively improve the motor function, stability and proprioception of knee joint, as well as the anxiety emotion in patients after meniscectomy under arthroscopy.
Humans
;
Arthroscopy
;
Meniscectomy
;
Resistance Training
;
Treatment Outcome
;
Osteoarthritis, Knee/therapy*
;
Acupuncture Therapy
;
Exercise Therapy
;
Muscles
;
Muscle Strength
;
Acupuncture Points
10.Development and characteristics of auricular fumigation moxibustion combined with heat-sensitive moxibustion device.
Xue-Tao ZHANG ; Zhen WANG ; Han-Xiao WANG ; Ya-Lu WANG ; Xin WU ; Kun WANG ; Shuai CUI ; Mei-Qi ZHOU ; Hui LUO ; Can-Guang SUN ; Sheng-Bing WU
Chinese Acupuncture & Moxibustion 2023;43(11):1333-1337
A moxibustion device with the functions of auricular fumigation moxibustion and heat-sensitive moxibustion is designed. The smoke of the ignited moxa stick is used for the fumigation moxibustion at the external auditory canal, while the heat generated works on Dazhui (GV 14) for heat-sensitive moxibustion. The device consists of five parts, i.e. combustion chamber, smoke pipe, smoke processing chamber, power module and connector. It solves the limitations such as unpleasant experience in treatment, unfavorable temperature control, easy scalding and excessive manual dependence induced by usual fumigation moxibustion and during heat-sensitive moxibustion. This moxibustion device may improve the safety and convenience when delivering the treatment with fumigation moxibustion and heat-sensitive moxibustion, as well as the work efficiency of medical staff.
Humans
;
Moxibustion
;
Hot Temperature
;
Fumigation
;
Smoke
;
Temperature

Result Analysis
Print
Save
E-mail