1.Feasibility study of using bridging temporary permanent pacemaker in patients with high-degree atrioventricular block after TAVR.
San Shuai CHANG ; Xin Min LIU ; Zhi Nan LU ; Jing YAO ; Cneng Qian YIN ; Wen Hui WU ; Fei YUAN ; Tai Yang LUO ; Zheng Ming JIANG ; Guang Yuan SONG
Chinese Journal of Cardiology 2023;51(6):648-655
Objective: To determine the feasibility of using temporary permanent pacemaker (TPPM) in patients with high-degree atrioventricular block (AVB) after transcatheter aortic valve replacement (TAVR) as bridging strategy to reduce avoidable permanent pacemaker implantation. Methods: This is a prospective observational study. Consecutive patients undergoing TAVR at Beijing Anzhen Hospital and the First Affiliated Hospital of Zhengzhou University from August 2021 to February 2022 were screened. Patients with high-degree AVB and TPPM were included. Patients were followed up for 4 weeks with pacemaker interrogation at every week. The endpoint was the success rate of TPPM removal and free from permanent pacemaker at 1 month after TPPM. The criteria of removing TPPM was no indication of permanent pacing and no pacing signal in 12 lead electrocardiogram (EGG) and 24 hours dynamic EGG, meanwhile the last pacemaker interrogation indicated that ventricular pacing rate was 0. Routinely follow-up ECG was extended to 6 months after removal of TPPM. Results: Ten patients met the inclusion criteria for TPPM, aged (77.0±11.1) years, wirh 7 females. There were 7 patients with third-degree AVB, 1 patient with second-degree AVB, 2 patients with first degree AVB with PR interval>240 ms and LBBB with QRS duration>150 ms. TPPM were applied on the 10 patients for (35±7) days. Among 8 patients with high-degree AVB, 3 recovered to sinus rhythm, and 3 recovered to sinus rhythm with bundle branch block. The other 2 patients with persistent third-degree AVB received permanent pacemaker implantation. For the 2 patients with first-degree AVB and LBBB, PR interval shortened to within 200 ms. TPPM was successfully removed in 8 patients (8/10) at 1 month without permanent pacemaker implantation, of which 2 patients recovered within 24 hours after TAVR and 6 patients recovered 24 hours later after TAVR. No aggravation of conduction block or permanent pacemaker indication were observed in 8 patients during follow-up at 6 months. No procedure-related adverse events occurred in all patients. Conclusion: TPPM is reliable and safe to provide certain buffer time to distinguish whether a permanent pacemaker is necessary in patients with high-degree conduction block after TAVR.
Female
;
Humans
;
Atrioventricular Block/therapy*
;
Feasibility Studies
;
Transcatheter Aortic Valve Replacement
;
Pacemaker, Artificial
;
Bundle-Branch Block
2.Incidence and prognosis of olfactory and gustatory dysfunctions related to infection of SARS-CoV-2 Omicron strain: a national multi-center survey of 35 566 population.
Meng Fan LIU ; Rui Xia MA ; Xian Bao CAO ; Hua ZHANG ; Shui Hong ZHOU ; Wei Hong JIANG ; Yan JIANG ; Jing Wu SUN ; Qin Tai YANG ; Xue Zhong LI ; Ya Nan SUN ; Li SHI ; Min WANG ; Xi Cheng SONG ; Fu Quan CHEN ; Xiao Shu ZHANG ; Hong Quan WEI ; Shao Qing YU ; Dong Dong ZHU ; Luo BA ; Zhi Wei CAO ; Xu Ping XIAO ; Xin WEI ; Zhi Hong LIN ; Feng Hong CHEN ; Chun Guang SHAN ; Guang Ke WANG ; Jing YE ; Shen Hong QU ; Chang Qing ZHAO ; Zhen Lin WANG ; Hua Bin LI ; Feng LIU ; Xiao Bo CUI ; Sheng Nan YE ; Zheng LIU ; Yu XU ; Xiao CAI ; Wei HANG ; Ru Xin ZHANG ; Yu Lin ZHAO ; Guo Dong YU ; Guang Gang SHI ; Mei Ping LU ; Yang SHEN ; Yu Tong ZHAO ; Jia Hong PEI ; Shao Bing XIE ; Long Gang YU ; Ye Hai LIU ; Shao wei GU ; Yu Cheng YANG ; Lei CHENG ; Jian Feng LIU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2023;58(6):579-588
Objective: This cross-sectional investigation aimed to determine the incidence, clinical characteristics, prognosis, and related risk factors of olfactory and gustatory dysfunctions related to infection with the SARS-CoV-2 Omicron strain in mainland China. Methods: Data of patients with SARS-CoV-2 from December 28, 2022, to February 21, 2023, were collected through online and offline questionnaires from 45 tertiary hospitals and one center for disease control and prevention in mainland China. The questionnaire included demographic information, previous health history, smoking and alcohol drinking, SARS-CoV-2 vaccination, olfactory and gustatory function before and after infection, other symptoms after infection, as well as the duration and improvement of olfactory and gustatory dysfunction. The self-reported olfactory and gustatory functions of patients were evaluated using the Olfactory VAS scale and Gustatory VAS scale. Results: A total of 35 566 valid questionnaires were obtained, revealing a high incidence of olfactory and taste dysfunctions related to infection with the SARS-CoV-2 Omicron strain (67.75%). Females(χ2=367.013, P<0.001) and young people(χ2=120.210, P<0.001) were more likely to develop these dysfunctions. Gender(OR=1.564, 95%CI: 1.487-1.645), SARS-CoV-2 vaccination status (OR=1.334, 95%CI: 1.164-1.530), oral health status (OR=0.881, 95%CI: 0.839-0.926), smoking history (OR=1.152, 95%CI=1.080-1.229), and drinking history (OR=0.854, 95%CI: 0.785-0.928) were correlated with the occurrence of olfactory and taste dysfunctions related to SARS-CoV-2(above P<0.001). 44.62% (4 391/9 840) of the patients who had not recovered their sense of smell and taste also suffered from nasal congestion, runny nose, and 32.62% (3 210/9 840) suffered from dry mouth and sore throat. The improvement of olfactory and taste functions was correlated with the persistence of accompanying symptoms(χ2=10.873, P=0.001). The average score of olfactory and taste VAS scale was 8.41 and 8.51 respectively before SARS-CoV-2 infection, but decreased to3.69 and 4.29 respectively after SARS-CoV-2 infection, and recovered to 5.83and 6.55 respectively at the time of the survey. The median duration of olfactory and gustatory dysfunctions was 15 days and 12 days, respectively, with 0.5% (121/24 096) of patients experiencing these dysfunctions for more than 28 days. The overall self-reported improvement rate of smell and taste dysfunctions was 59.16% (14 256/24 096). Gender(OR=0.893, 95%CI: 0.839-0.951), SARS-CoV-2 vaccination status (OR=1.334, 95%CI: 1.164-1.530), history of head and facial trauma(OR=1.180, 95%CI: 1.036-1.344, P=0.013), nose (OR=1.104, 95%CI: 1.042-1.171, P=0.001) and oral (OR=1.162, 95%CI: 1.096-1.233) health status, smoking history(OR=0.765, 95%CI: 0.709-0.825), and the persistence of accompanying symptoms (OR=0.359, 95%CI: 0.332-0.388) were correlated with the recovery of olfactory and taste dysfunctions related to SARS-CoV-2 (above P<0.001 except for the indicated values). Conclusion: The incidence of olfactory and taste dysfunctions related to infection with the SARS-CoV-2 Omicron strain is high in mainland China, with females and young people more likely to develop these dysfunctions. Active and effective intervention measures may be required for cases that persist for a long time. The recovery of olfactory and taste functions is influenced by several factors, including gender, SARS-CoV-2 vaccination status, history of head and facial trauma, nasal and oral health status, smoking history, and persistence of accompanying symptoms.
Female
;
Humans
;
Adolescent
;
SARS-CoV-2
;
Smell
;
COVID-19/complications*
;
Cross-Sectional Studies
;
COVID-19 Vaccines
;
Incidence
;
Olfaction Disorders/etiology*
;
Taste Disorders/etiology*
;
Prognosis
3.Safety and efficacy of transcatheter aortic valve replacement using the "All in One" single artery/vessel technique.
Jing YAO ; Xin Min LIU ; Fei YUAN ; Tai Yang LUO ; Zhi Nan LU ; Yun Feng YAN ; San Shuai CHANG ; Guang Yuan SONG
Chinese Journal of Cardiology 2023;51(9):990-994
Objective: To explore the safety and efficacy of transcatheter aortic valve replacement (TAVR) using the "All in One" single-artery/vessel technique. Methods: This is a retrospective study. A total of 30 consecutive patients underwent TAVR using the single artery/vascular technique in Beijing Anzhen Hospital from August to December 2021 were included. Baseline clinical data, operative situation, postoperative outcomes, and incidence of adverse events during hospitalization and at one month post TAVR were analyzed. Results: Mean age was (72.6±9.7) years, 16 were male patients, STS score was (4.73±3.12)%. Four patients were diagnosed as isolated aortic regurgitation (all with tricuspid aortic valves), and 26 patients were diagnosed as aortic stenosis (AS), 10 of whom with tricuspid aortic valves and 16 of whom with bicuspid aortic valves. The single-vessel technique was applied in 3 aortic stenosis cases; the single-artery technique was applied in 27 cases. Echocardiography was performed immediately after procedure and results showed no or trace perivalvular leak in 27 cases and small perivalvular leak in 3 cases; the mean aortic transvalvular gradient of 26 AS patients decreased from (50.4±16.0) mmHg (1 mmHg=0.133 kPa) to (9.4±3.2) mmHg (P<0.001). The procedure time was (64.8±18.9) min. There were no intraoperative death, valve displacement, conversion to surgery, coronary artery occlusion in all 30 patients. There were no major cardiac adverse events such as myocardial infarction or stroke occurred during hospitalization or at follow-up. One-month follow-up echocardiography indicated prosthesis works well. The symptoms were significantly alleviated, and the Kansas City Cardiomyopathy Score (KCCQ score) of all patients increased from 48.1±18.4 to 73.5±17.6 (P<0.001). Conclusions: TAVR using the single artery/vessel technique is safe and feasible. This technique is related to reduced access complications and worthy of wide application.
Humans
;
Male
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Female
;
Transcatheter Aortic Valve Replacement
;
Retrospective Studies
;
Arteries
;
Aorta
;
Aortic Valve Stenosis/surgery*
4.Safety and efficacy of transcatheter aortic valve replacement using the "All in One" single artery/vessel technique.
Jing YAO ; Xin Min LIU ; Fei YUAN ; Tai Yang LUO ; Zhi Nan LU ; Yun Feng YAN ; San Shuai CHANG ; Guang Yuan SONG
Chinese Journal of Cardiology 2023;51(9):990-994
Objective: To explore the safety and efficacy of transcatheter aortic valve replacement (TAVR) using the "All in One" single-artery/vessel technique. Methods: This is a retrospective study. A total of 30 consecutive patients underwent TAVR using the single artery/vascular technique in Beijing Anzhen Hospital from August to December 2021 were included. Baseline clinical data, operative situation, postoperative outcomes, and incidence of adverse events during hospitalization and at one month post TAVR were analyzed. Results: Mean age was (72.6±9.7) years, 16 were male patients, STS score was (4.73±3.12)%. Four patients were diagnosed as isolated aortic regurgitation (all with tricuspid aortic valves), and 26 patients were diagnosed as aortic stenosis (AS), 10 of whom with tricuspid aortic valves and 16 of whom with bicuspid aortic valves. The single-vessel technique was applied in 3 aortic stenosis cases; the single-artery technique was applied in 27 cases. Echocardiography was performed immediately after procedure and results showed no or trace perivalvular leak in 27 cases and small perivalvular leak in 3 cases; the mean aortic transvalvular gradient of 26 AS patients decreased from (50.4±16.0) mmHg (1 mmHg=0.133 kPa) to (9.4±3.2) mmHg (P<0.001). The procedure time was (64.8±18.9) min. There were no intraoperative death, valve displacement, conversion to surgery, coronary artery occlusion in all 30 patients. There were no major cardiac adverse events such as myocardial infarction or stroke occurred during hospitalization or at follow-up. One-month follow-up echocardiography indicated prosthesis works well. The symptoms were significantly alleviated, and the Kansas City Cardiomyopathy Score (KCCQ score) of all patients increased from 48.1±18.4 to 73.5±17.6 (P<0.001). Conclusions: TAVR using the single artery/vessel technique is safe and feasible. This technique is related to reduced access complications and worthy of wide application.
Humans
;
Male
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Female
;
Transcatheter Aortic Valve Replacement
;
Retrospective Studies
;
Arteries
;
Aorta
;
Aortic Valve Stenosis/surgery*
5.Retrospective analysis of short-term curative effect of total laparoscopic loop ileostomy reversal after radical resection of rectal cancer.
Shou LUO ; Hao SU ; Zheng XU ; Jin Tao ZHOU ; Yun Bin MA ; Huai Gang CHEN ; Ming LIU ; Li Biao GONG ; Fu YANG ; Xue Dui WU ; Ming YUAN ; Ming Guang ZHANG ; Jina Wei LIANG ; Qian LIU ; Zhi Xiang ZHOU ; Xi Shan WANG ; Hai Tao ZHOU
Chinese Journal of Oncology 2022;44(12):1385-1390
Objective: To investigate the safety, feasibility and short-term efficacy of total laparoscopic loop ileostomy reversal in patients after resection of rectal cancer. Methods: The clinical data of 20 patients who underwent total laparoscopic loop ileoscopic loop ileostomy after radical resection of rectal cancer at Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, or Beijing Chaoyang District Sanhuan Cancer Hospital from October 2019 to June 2020 were collected and retrospectively analyzed. Results: All patients had successfully underwent total laparoscopic ileostomy reversal without conversion to open surgery or discontinued operation. No perioperative related death cases were found. In the whole group, the median operation time was 97 (60-145) minutes and the median intraoperative blood loss was 20 (10-100) milliliters. The median Visual Analogue Scale (VAS) score was 1.9 (1-5) one day after the operation. Nobody needed to use additional analgesic drugs. The median time to grand activities was 25 (16-42) hours, the median time to flatus was 44 (19-51) hours, and the median hospitalization after operation was 6.9 (5-9) days. No patients underwent operation related complications such as operative incision infection, abdominal and pelvic infection, intestinal obstruction, anastomotic leakage, bleeding and so on. Conclusions: Total laparoscopic loop ileostomy reversal appears to be safe, feasible and with promising efficacy for selected patients.
Humans
;
Ileostomy
;
Retrospective Studies
;
Laparoscopy
;
Rectal Neoplasms/surgery*
;
Anastomotic Leak
;
Anastomosis, Surgical
6.Data mining-based analysis of formulation rules for prescriptions containing herbal pair Acori Tatarinowii Rhizoma-Polygalae Radix.
Zhe SONG ; Zhi-Yan HUANG ; Yu FENG ; Bao-Qing ZHANG ; Guang-Zhi LUO
China Journal of Chinese Materia Medica 2022;47(6):1687-1693
By the in-depth excavation of prescriptions containing herbal pair Acori Tatarinowii Rhizoma-Polygalae Radix in the Dictionary of Traditional Chinese Medicine Prescriptions, this study analyzed their formulation rules, so as to provide reference for their clinical application and new drug development. First, the prescriptions containing Acori Tatarinowii Rhizoma-Polygalae Radix were collected from the Dictionary of Traditional Chinese Medicine Prescriptions, and their indications, herbal compatibility, and dosage forms were analyzed statistically using the Traditional Chinese Medicine Inheritance Support System(TCMISS). Meanwhile, the formulation rules and common dosage forms for the top four indications(amnesia, palpitation, mania, and epilepsy) sorted by frequency were analyzed with Apriori algorithm. A total of 507 prescriptions containing Acori Tatarinowii Rhizoma-Polygalae Radix were screened out, involving 15 indications(frequency>10) like amnesia, palpitation, mania, and epilepsy. There were 30 commonly used Chinese herbs(frequency≥60), with the Qi-tonifying herbs(Ginseng Radix et Rhizoma and Glycyrrhizae Radix et Rhizome), mind-tranquilizing herbs(Poria and Poria cum Radix Pini), and Yin-nourishing herbs(Angelicae Sinensis Radix and Ophiopogonis Radix) being the core ones. The commonly used dosage forms were honey pill, paste pill, decoction, and powder. These have indicated that the herbal pair Acori Tatarinowii Rhizoma-Polygalae Radix is often combined with Qi-tonifying, Yin-nourishing, and mind-tranquilizing herbs for the treatment of "heart or brain diseases" caused by phlegm production due to spleen deficiency, Qi and blood deficiency, and phlegm-turbidity blocking orifice. In the treatment of amnesia, supplementing essence and replenishing marrow are considered on the basis of tonifying Qi, nourishing Yin, and tranquilizing mind. In the treatment of palpitation and mania, tranquilizing mind is emphasized. In the treatment of epilepsy, the emphasis is placed on resolving phlegm, extinguishing wind, and stopping convulsion.
Data Mining
;
Medicine, Chinese Traditional
;
Plant Roots
;
Prescriptions
;
Rhizome
7. Expression of elastin and collagen in rats with heart failure
Ke-Ke WANG ; Xiang-Guang MENG ; Qian WANG ; Zhi-Kun GUO ; Huan-Huan LUO ; Zhi-Kun GUO
Acta Anatomica Sinica 2022;53(5):637-643
Objective To investigate the expression of elastin and collagen in heart of rats with chronic heart failure and their related proteases. Methods Sprague-Dawley rat model of chronic heart failure was made by intraperitoneal injection of doxorubicin hydrochloride. Examination of cardiac function by echocardiography. ELISA and immunohistochemistry were used to detect brain natriuretic peptide ( BNP) , and Masson staining was used to detect myocardial fibrosis. The mRNA levels of elastin, I /IH collagen were detected by Real-time PCR and the expression levels of elastin, I/IH collagen, Matrix metalloproteinase (MMP)-2 and MMP-9 were detected by Western blotting. Results Compared with the control group, the heart function of rats in the model group decreased, the BNP content in serum increased, the expression of BNP in myocardial tissue was strongly positive, and the mRNA and protein expression of elastin decreased. Nevertheless, the mRNA and protein expression of I / IH collagen increased. At the same time, both MMP-2 and MMP-9 protein expression levels increased in model rat heart. Conclusion Heart failure leads to decreased expression of elastin, I /IH collagen expression increased, and the MMP-2 and MMP-9 may be involved in the regulation of this process.
8.Single center experience of transcatheter aortic valve replacement with a simplified operative protocol.
Guang Yuan SONG ; Yue Wu ZHAO ; Guo Yong DU ; Yang CHEN ; Mo Yang WANG ; Si Yong TENG ; Tong LUO ; Zheng ZHOU ; Guan Nan NIU ; Zhen Yan ZHAO ; Zhi Nan LU ; Yong Jian WU
Chinese Journal of Cardiology 2022;50(6):563-569
Objective: To summarize the single center experience of transcatheter aortic valve replacement (TAVR) with a simplified operative protocol. Methods: Consecutive patients who underwent transfemoral TAVR (TF-TAVR) from July 2020 to December 2020 in Fuwai Hospital were retrospectively analyzed. We compared the baseline characteristic, procedure information, 30-day follow-up outcomes of the patients who underwent TF-TAVR without the simplified operative protocol (routine group) or with the simplified operative protocol (simplified protocol group). Results: 93 patients were collected, 42 patients belonging to routine group, 51 patients belonging to simplified protocol group. In simplified protocol group, there were 51 patients planned to use ultrasound-guided femoral access puncture, procedure was successful in all 51 patients (100%). There were 49 patients planned to use the radial artery as the secondary access, procedure was successful in 45 patients (92%). There were 48 patients planned to use the strategy of avoidance of urinary catheter, this strategy was achieved in 35 patients (73%). There were 12 patients planned to use the left ventricular guidewire to pace, procedure was successful in 11 patients (92%). There were no differences in baseline characteristics, major clinical endpoints and 30-day follow-up outcomes between the two groups. Meanwhile, the procedure time ((62.5±17.9)min vs. (78.3±16.7)min, P<0.001), operation room time ((133.7±25.1)min vs. (159.2±42.6)min, P<0.001), X-ray exposure time ((17.2±6.5)min vs. (20.2±7.7)min, P=0.027) were significantly shorten in simplified protocol group compared with the routine group. Conclusion: Our study results indicate that the simplified operative protocol of TF-TAVR is as effective and safe as the routine operative protocol, meanwhile using the simplified operative protocol can significantly increase the operative efficiency of TF-TAVR.
Aortic Valve
;
Aortic Valve Stenosis/surgery*
;
Femoral Artery/surgery*
;
Humans
;
Retrospective Studies
;
Risk Factors
;
Time Factors
;
Transcatheter Aortic Valve Replacement/methods*
;
Treatment Outcome
9.Alternative Splicing of RHD mRNA by the Next-generation Sequencing in RhD-positive Individuals
Ya-lin LUO ; Ling WEI ; Yan-li JI ; Guang-ping LUO ; Yong-shui FU ; Ji-zhi WEN ; Cheng-yao LI
Journal of Sun Yat-sen University(Medical Sciences) 2021;42(1):51-56
ObjectiveThis study aimed to analyze different transcripts specifically expressed by red blood cells in RhD-positive individuals, and to explore the mechanism of alternative splicing. MethodsErythroblasts from RhD-positive individuals were isolated and cultured in an in vitro erythroblast culture system. The fragment from exon 6 to 3’untranslated coding regions of RHD gene of RhD-positive individuals was amplified by reverse transcription polymerase chain reaction (RT-PCR) method. The PCR products were then sequenced by next-generation sequencing and the mRNA transcripts were analyzed. The maximum entropy values of 5’ splice site (ss) and 3’ ss of all exons of RHD gene were analyzed using bioinformatics. ResultsThe transcripts of the RHD gene were mainly normal full-length mRNA. In addition, eight other abnormal transcripts were also identified. According to the expression frequencies (high to low), these transcripts were exon 7 deletion, exon 9 deletion, exons 8 and 9 deletion, exons 7-9 deletion, exons 7 and 9 deletion, exons 8-9 deletion and 170 bp insertion between exon 7 and 10, full-length with 170 bp insertion between exon 7 and 8, exon 9 deletion and 170 bp insertion between exon 7 and 8. The last three transcripts were novel. Bioinformatic analysis suggested that the abnormal splicing of exon 7 and exon 9 might be due to the decreased binding ability of 5’ss or 3’ss to the spliceosome. The intron 7 was expressed in mRNA, which might be related to the sequences conserved with 5’ss and 3’ss splicing. ConclusionThe alternative splicing patterns of RHD gene are very complicated, which leads to various transcripts at the mRNA level of the RHD gene from RhD-positive individuals.

Result Analysis
Print
Save
E-mail