1.Diagnostic performance of quantitative ultrasonography for hepatic steatosis in a health screening program: a prospective single-center study
Jeung Hui PYO ; Soo Jin CHO ; Sung Chul CHOI ; Jae Hwan JEE ; Jeeyeong YUN ; Jeong Ah HWANG ; Goeun PARK ; Kyunga KIM ; Wonseok KANG ; Mira KANG ; Young hye BYUN
Ultrasonography 2024;43(4):250-262
Purpose:
This study compared the diagnostic performance of quantitative ultrasonography (QUS) with that of conventional ultrasonography (US) in assessing hepatic steatosis among individuals undergoing health screening using magnetic resonance imaging–derived proton density fat fraction (MRI-PDFF) as the reference standard.
Methods:
This single-center prospective study enrolled 427 participants who underwent abdominal MRI and US. Measurements included the attenuation coefficient in tissue attenuation imaging (TAI) and the scatter-distribution coefficient in tissue scatter-distribution imaging (TSI). The correlation between QUS and MRI-PDFF was evaluated. The diagnostic capabilities of QUS, conventional B-mode US, and their combined models for detecting hepatic fat content of ≥5% (MRI-PDFF ≥5%) and ≥10% (MRI-PDFF ≥10%) were compared by analyzing the areas under the receiver operating characteristic curves. Additionally, clinical risk factors influencing the diagnostic performance of QUS were identified using multivariate linear regression analyses.
Results:
TAI and TSI were strongly correlated with MRI-PDFF (r=0.759 and r=0.802, respectively; both P<0.001) and demonstrated good diagnostic performance in detecting and grading hepatic steatosis. The combination of QUS and B-mode US resulted in the highest areas under the ROC curve (AUCs) (0.947 and 0.975 for detecting hepatic fat content of ≥5% and ≥10%, respectively; both P<0.05), compared to TAI, TSI, or B-mode US alone (AUCs: 0.887, 0.910, 0.878 for ≥5% and 0.951, 0.922, 0.875 for ≥10%, respectively). The independent determinants of QUS included skinliver capsule distance (β=7.134), hepatic fibrosis (β=4.808), alanine aminotransferase (β=0.202), triglyceride levels (β=0.027), and diabetes mellitus (β=3.710).
Conclusion
QUS is a useful and effective screening tool for detecting and grading hepatic steatosis during health checkups.
2.Diagnostic performance of quantitative ultrasonography for hepatic steatosis in a health screening program: a prospective single-center study
Jeung Hui PYO ; Soo Jin CHO ; Sung Chul CHOI ; Jae Hwan JEE ; Jeeyeong YUN ; Jeong Ah HWANG ; Goeun PARK ; Kyunga KIM ; Wonseok KANG ; Mira KANG ; Young hye BYUN
Ultrasonography 2024;43(4):250-262
Purpose:
This study compared the diagnostic performance of quantitative ultrasonography (QUS) with that of conventional ultrasonography (US) in assessing hepatic steatosis among individuals undergoing health screening using magnetic resonance imaging–derived proton density fat fraction (MRI-PDFF) as the reference standard.
Methods:
This single-center prospective study enrolled 427 participants who underwent abdominal MRI and US. Measurements included the attenuation coefficient in tissue attenuation imaging (TAI) and the scatter-distribution coefficient in tissue scatter-distribution imaging (TSI). The correlation between QUS and MRI-PDFF was evaluated. The diagnostic capabilities of QUS, conventional B-mode US, and their combined models for detecting hepatic fat content of ≥5% (MRI-PDFF ≥5%) and ≥10% (MRI-PDFF ≥10%) were compared by analyzing the areas under the receiver operating characteristic curves. Additionally, clinical risk factors influencing the diagnostic performance of QUS were identified using multivariate linear regression analyses.
Results:
TAI and TSI were strongly correlated with MRI-PDFF (r=0.759 and r=0.802, respectively; both P<0.001) and demonstrated good diagnostic performance in detecting and grading hepatic steatosis. The combination of QUS and B-mode US resulted in the highest areas under the ROC curve (AUCs) (0.947 and 0.975 for detecting hepatic fat content of ≥5% and ≥10%, respectively; both P<0.05), compared to TAI, TSI, or B-mode US alone (AUCs: 0.887, 0.910, 0.878 for ≥5% and 0.951, 0.922, 0.875 for ≥10%, respectively). The independent determinants of QUS included skinliver capsule distance (β=7.134), hepatic fibrosis (β=4.808), alanine aminotransferase (β=0.202), triglyceride levels (β=0.027), and diabetes mellitus (β=3.710).
Conclusion
QUS is a useful and effective screening tool for detecting and grading hepatic steatosis during health checkups.
3.Diagnostic performance of quantitative ultrasonography for hepatic steatosis in a health screening program: a prospective single-center study
Jeung Hui PYO ; Soo Jin CHO ; Sung Chul CHOI ; Jae Hwan JEE ; Jeeyeong YUN ; Jeong Ah HWANG ; Goeun PARK ; Kyunga KIM ; Wonseok KANG ; Mira KANG ; Young hye BYUN
Ultrasonography 2024;43(4):250-262
Purpose:
This study compared the diagnostic performance of quantitative ultrasonography (QUS) with that of conventional ultrasonography (US) in assessing hepatic steatosis among individuals undergoing health screening using magnetic resonance imaging–derived proton density fat fraction (MRI-PDFF) as the reference standard.
Methods:
This single-center prospective study enrolled 427 participants who underwent abdominal MRI and US. Measurements included the attenuation coefficient in tissue attenuation imaging (TAI) and the scatter-distribution coefficient in tissue scatter-distribution imaging (TSI). The correlation between QUS and MRI-PDFF was evaluated. The diagnostic capabilities of QUS, conventional B-mode US, and their combined models for detecting hepatic fat content of ≥5% (MRI-PDFF ≥5%) and ≥10% (MRI-PDFF ≥10%) were compared by analyzing the areas under the receiver operating characteristic curves. Additionally, clinical risk factors influencing the diagnostic performance of QUS were identified using multivariate linear regression analyses.
Results:
TAI and TSI were strongly correlated with MRI-PDFF (r=0.759 and r=0.802, respectively; both P<0.001) and demonstrated good diagnostic performance in detecting and grading hepatic steatosis. The combination of QUS and B-mode US resulted in the highest areas under the ROC curve (AUCs) (0.947 and 0.975 for detecting hepatic fat content of ≥5% and ≥10%, respectively; both P<0.05), compared to TAI, TSI, or B-mode US alone (AUCs: 0.887, 0.910, 0.878 for ≥5% and 0.951, 0.922, 0.875 for ≥10%, respectively). The independent determinants of QUS included skinliver capsule distance (β=7.134), hepatic fibrosis (β=4.808), alanine aminotransferase (β=0.202), triglyceride levels (β=0.027), and diabetes mellitus (β=3.710).
Conclusion
QUS is a useful and effective screening tool for detecting and grading hepatic steatosis during health checkups.
4.Diagnostic performance of quantitative ultrasonography for hepatic steatosis in a health screening program: a prospective single-center study
Jeung Hui PYO ; Soo Jin CHO ; Sung Chul CHOI ; Jae Hwan JEE ; Jeeyeong YUN ; Jeong Ah HWANG ; Goeun PARK ; Kyunga KIM ; Wonseok KANG ; Mira KANG ; Young hye BYUN
Ultrasonography 2024;43(4):250-262
Purpose:
This study compared the diagnostic performance of quantitative ultrasonography (QUS) with that of conventional ultrasonography (US) in assessing hepatic steatosis among individuals undergoing health screening using magnetic resonance imaging–derived proton density fat fraction (MRI-PDFF) as the reference standard.
Methods:
This single-center prospective study enrolled 427 participants who underwent abdominal MRI and US. Measurements included the attenuation coefficient in tissue attenuation imaging (TAI) and the scatter-distribution coefficient in tissue scatter-distribution imaging (TSI). The correlation between QUS and MRI-PDFF was evaluated. The diagnostic capabilities of QUS, conventional B-mode US, and their combined models for detecting hepatic fat content of ≥5% (MRI-PDFF ≥5%) and ≥10% (MRI-PDFF ≥10%) were compared by analyzing the areas under the receiver operating characteristic curves. Additionally, clinical risk factors influencing the diagnostic performance of QUS were identified using multivariate linear regression analyses.
Results:
TAI and TSI were strongly correlated with MRI-PDFF (r=0.759 and r=0.802, respectively; both P<0.001) and demonstrated good diagnostic performance in detecting and grading hepatic steatosis. The combination of QUS and B-mode US resulted in the highest areas under the ROC curve (AUCs) (0.947 and 0.975 for detecting hepatic fat content of ≥5% and ≥10%, respectively; both P<0.05), compared to TAI, TSI, or B-mode US alone (AUCs: 0.887, 0.910, 0.878 for ≥5% and 0.951, 0.922, 0.875 for ≥10%, respectively). The independent determinants of QUS included skinliver capsule distance (β=7.134), hepatic fibrosis (β=4.808), alanine aminotransferase (β=0.202), triglyceride levels (β=0.027), and diabetes mellitus (β=3.710).
Conclusion
QUS is a useful and effective screening tool for detecting and grading hepatic steatosis during health checkups.
5.Diagnostic performance of quantitative ultrasonography for hepatic steatosis in a health screening program: a prospective single-center study
Jeung Hui PYO ; Soo Jin CHO ; Sung Chul CHOI ; Jae Hwan JEE ; Jeeyeong YUN ; Jeong Ah HWANG ; Goeun PARK ; Kyunga KIM ; Wonseok KANG ; Mira KANG ; Young hye BYUN
Ultrasonography 2024;43(4):250-262
Purpose:
This study compared the diagnostic performance of quantitative ultrasonography (QUS) with that of conventional ultrasonography (US) in assessing hepatic steatosis among individuals undergoing health screening using magnetic resonance imaging–derived proton density fat fraction (MRI-PDFF) as the reference standard.
Methods:
This single-center prospective study enrolled 427 participants who underwent abdominal MRI and US. Measurements included the attenuation coefficient in tissue attenuation imaging (TAI) and the scatter-distribution coefficient in tissue scatter-distribution imaging (TSI). The correlation between QUS and MRI-PDFF was evaluated. The diagnostic capabilities of QUS, conventional B-mode US, and their combined models for detecting hepatic fat content of ≥5% (MRI-PDFF ≥5%) and ≥10% (MRI-PDFF ≥10%) were compared by analyzing the areas under the receiver operating characteristic curves. Additionally, clinical risk factors influencing the diagnostic performance of QUS were identified using multivariate linear regression analyses.
Results:
TAI and TSI were strongly correlated with MRI-PDFF (r=0.759 and r=0.802, respectively; both P<0.001) and demonstrated good diagnostic performance in detecting and grading hepatic steatosis. The combination of QUS and B-mode US resulted in the highest areas under the ROC curve (AUCs) (0.947 and 0.975 for detecting hepatic fat content of ≥5% and ≥10%, respectively; both P<0.05), compared to TAI, TSI, or B-mode US alone (AUCs: 0.887, 0.910, 0.878 for ≥5% and 0.951, 0.922, 0.875 for ≥10%, respectively). The independent determinants of QUS included skinliver capsule distance (β=7.134), hepatic fibrosis (β=4.808), alanine aminotransferase (β=0.202), triglyceride levels (β=0.027), and diabetes mellitus (β=3.710).
Conclusion
QUS is a useful and effective screening tool for detecting and grading hepatic steatosis during health checkups.
6.Clinical Effect of Endosonography on Overall Survival in Patients with Radiological N1 Non–Small Cell Lung Cancer
Bo-Guen KIM ; Byeong-Ho JEONG ; Goeun PARK ; Hong Kwan KIM ; Young Mog SHIM ; Sun Hye SHIN ; Kyungjong LEE ; Sang-Won UM ; Hojoong KIM ; Jong Ho CHO
Cancer Research and Treatment 2024;56(2):502-512
Purpose:
It is unclear whether performing endosonography first in non–small cell lung cancer (NSCLC) patients with radiological N1 (rN1) has any advantages over surgery without nodal staging. We aimed to compare surgery without endosonography to performing endosonography first in rN1 on the overall survival (OS) of patients with NSCLC.
Materials and Methods:
This is a retrospective analysis of patients with rN1 NSCLC between 2013 and 2019. Patients were divided into ‘no endosonography’ and ‘endosonography first’ groups. We investigated the effect of nodal staging through endosonography on OS using propensity score matching (PSM) and multivariable Cox proportional hazard regression analysis.
Results:
In the no endosonography group, pathologic N2 occurred in 23.0% of patients. In the endosonography first group, endosonographic N2 and N3 occurred in 8.6% and 1.6% of patients, respectively. Additionally, 51 patients were pathologic N2 among 249 patients who underwent surgery and mediastinal lymph node dissection (MLND) in endosonography first group. After PSM, the 5-year OSs were 68.1% and 70.6% in the no endosonography and endosonography first groups, respectively. However, the 5-year OS was 80.2% in the subgroup who underwent surgery and MLND of the endosonography first group. Moreover, in patients receiving surgical resection with MLND, the endosonography first group tended to have a better OS than the no endosonography group in adjusted analysis using various models.
Conclusion
In rN1 NSCLC, preoperative endosonography shows better OS than surgery without endosonography. For patients with rN1 NSCLC who are candidates for surgery, preoperative endosonography may help improve survival through patient selection.
7.Comparison of health literacy and health behaviors between Korean women with and without breast cancer
Journal of Korean Biological Nursing Science 2023;25(3):205-214
Purpose:
This descriptive survey compared health literacy and health behaviors between Korean women with and without breast cancer.
Methods:
In total, 95 women with and 97 women without breast cancer (age range: 40–69 years) completed the survey. Health literacy and health behavior were analyzed in women with and without breast cancer, using the Newest Vital Sign.
Results:
Women with breast cancer were less frequently alcohol drinkers (14.7% vs. 47.4%, p < .001) and more frequently exercised (65.3% vs. 49.5%, p = .027), obtained health information (17.9% vs. 8.2%, p = .047), and attended health education programs (10.5% vs. 1.0%, p = .005) than women without cancer. In both groups, women with higher literacy levels outnumbered those with limited literacy.
Conclusion
The results indicated that women with breast cancer were more likely to engage in health-promotion activities than women without cancer, and this increased their health literacy levels. The findings could inform interventions involving breast cancer prevention methods.
8.Factors predicting meaningful suicide attempts: multiple attempts and index methods
Chungmo KOO ; Goeun BAE ; Heoung Jin KIM ; Sohyun EUN ; Seo Hee YOON ; Moon Kyu KIM ; Hyun Soo CHUNG ; Hye Eun KWON
Pediatric Emergency Medicine Journal 2023;10(1):31-35
Purpose:
This study investigated the association of the index method, defined as the method used in the first suicide attempt (SA), with the outcome of SAs among adolescents.
Methods:
The study analyzed medical records of 227 adolescents aged 10-18 years with clear SAs who visited the emergency department of Severance Hospital in Seoul, Korea from January 2007 through February 2021, focusing on the index methods and meaningful SAs defined as hospitalization, death or transfer to another hospital for psychiatric hospitalization. The association of the index method with the meaningful SAs was quantified using logistic regression.
Results:
Among the 227 adolescents, 80 underwent the meaningful SAs (35.2%). The adolescents with the meaningful SA chose drug intoxication, fall, and hanging as the index methods more frequently than those without the outcome, whereas they showed a reverse pattern in cutting (P < 0.001). The association of fall or cutting with the meaningful SAs remained significant after adjustment (fall: adjusted odds ratio, 6.93 [95% confidence interval, 1.70-28.26]; cutting: 0.39 [0.17-0.91]; compared with those undergoing drug intoxication). Multiple SAs were also associated with the meaningful SA (1.76 [1.04-3.13]).
Conclusion
This study identifies the index method and multiple SAs as factors associated with the meaningful SA among adolescents in the emergency department. This finding may be helpful in interviewing adolescents with SAs.
9.Metastatic intestinal adenocarcinoma with osseous metaplasia in two Domestic Korean Shorthair cats
Jae-Ha JUNG ; Na-Yon KIM ; Yeseul YANG ; Dansong SEO ; Goeun CHOI ; Hyunki HONG ; Taeseong MOON ; Hyeong-Mok KIM ; Jihee HAN ; Jihee HONG ; Yongbaek KIM
Journal of Veterinary Science 2023;24(5):e64-
Two Domestic Korean Shorthair cats presented with dyschezia and vomiting. Computed tomography revealed a colonic mass with calcification and lymph node metastasis in case 1, and a small intestinal mass with disseminated mesenteric metastasis and calcification in case 2. Histopathology revealed intestinal adenocarcinoma with osseous metaplasia. Case 1 died two months after surgery from distant metastasis; and case 2 showed no metastasis for five months but presented with anorexia, euthanized seven months after diagnosis. Metastatic intestinal adenocarcinoma with bone formation should be considered as differential diagnosis for calcification on imaging, and lymph node metastasis at diagnosis may indicate poor prognosis.
10.Preliminary comparison of length of stay of patients treated by 3 board-certified physicians and 1 pediatric resident in the emergency department during night shifts
Goeun BAE ; So Hyun EUN ; Seo Hee YOON ; Moon Kyu KIM ; Chung Mo KOO
Pediatric Emergency Medicine Journal 2022;9(1):65-68
Shortage of doctors in emergency departments (EDs) is a root issue in maintaining ED-based residency programs. This study describes the efficiency of emergency practice according to board certification; 3 board-certified physicians versus a pediatric resident. Of 342 children, we found no differences as per the board certification in the ED length of stay, acuity, and return visits with more frequent hospitalization by the board-certified physicians. This result suggests that with a proper residency program, both board-certified physicians and residents can make a decision on hospitalization.