1.Central visual function and inner retinal structure in primary open-angle glaucoma.
Li-Juan XU ; Sha-Ling LI ; Vance ZEMON ; Yan-Qian XIE ; Yuan-Bo LIANG
Journal of Zhejiang University. Science. B 2020;21(4):305-314
To investigate associations between central visual function and inner retinal structure in primary open-angle glaucoma (POAG). This study enrolled 78 POAG patients and 58 healthy controls. POAG was classified into early glaucoma and moderate to advanced glaucoma. The following tests were performed on all participants: isolated-check visual evoked potential (icVEP) testing, 24-2 standard automated perimetry (SAP), and Cirrus optical coherence tomography (OCT) examinations. Signal-to-noise ratio (SNR) measures obtained from icVEP responses to isolated checks presented at four depths of modulation (DOMs; 8%, 14%, 22%, and 32%) were explored. Mean macular sensitivity (mMS) was assessed by calculating the mean sensitivities of central 12 SAP points. Ganglion cell layer+ inner plexiform layer thickness (GCL+IPLT) and peripapillary retinal nerve fiber layer thickness (pRNFLT) were measured by OCT scanning. For each group of subjects, linear relationships among the following measures were analyzed: SNR, mMS, GCL+IPLT, and pRNFLT. SNR, mMS, GCL+IPLT, and pRNFLT were all more significantly decreased in glaucoma than in controls (P<0.001). A significant positive association was found between SNR at 14% DOM and GCL+IPLT at the inferior sector in early glaucoma (r=0.465, P=0.004). In moderate to advanced glaucoma, significant correlations were found between SNR at 32% DOM and mean GCL+IPLT (r=0.364, P=0.023), superior GCL+IPLT (r=0.358, P=0.025), and mean pRNFLT (r=0.396, P=0.025). In addition, in moderate to advanced glaucoma, there were significant correlations between mMS and all relevant measures of retinal thickness (r=0.330-0.663, P< 0.010). In early glaucoma, significant correlations were found between mean mMS and minimum GCL+IPLT (r=0.373, P=0.023), and between inferior mMS and superior GCL+IPLT (r=0.470, P=0.003). Linear models provided a good explanation for the relationship between SNR and inner retinal thickness (IRT), whereas nonlinear models better explained the relationship between mMS and IRT. In early glaucoma, both SNR and mMS were related moderately and significantly to IRT, whereas in moderate to advanced glaucoma, mMS was more strongly correlated with IRT than SNR.
Adult
;
Aged
;
Evoked Potentials, Visual/physiology*
;
Female
;
Glaucoma, Open-Angle/physiopathology*
;
Humans
;
Macula Lutea/physiopathology*
;
Male
;
Middle Aged
;
Retina/physiopathology*
;
Signal-To-Noise Ratio
;
Tomography, Optical Coherence
2.Transitions of the Understanding and Definition of Primary Glaucoma.
Si-An LIU ; Zhen-Ni ZHAO ; Nan-Nan SUN ; Ying HAN ; Jeremy CHEN ; Zhi-Gang FAN
Chinese Medical Journal 2018;131(23):2852-2859
Objective:
In previous decades, glaucoma has been primarily attributed to elevated intraocular pressure (IOP), but this has gradually been replaced by the development of optic neuropathy as the central concept of glaucoma in developed countries. However, there still remain strong controversies in the definition of glaucoma in China. In this current review, we are going to discuss these controversies and elaborate on the historical transitions of the definition of glaucoma both in China and developed countries. Furthermore, we will briefly describe the "ocular-cranial pressure gradient" theory and discuss the relationship between glaucoma and degenerative diseases of the central nervous system (CNS) in order to show the complex pathogenesis of glaucoma and the importance for the modification to the definition of glaucoma.
Data Sources:
We performed a comprehensive search in both PubMed and SinoMed using the following keywords: (a) "primary glaucoma" and "guideline," (b) "ocular-cranial pressure gradient," and (c) "glaucoma," "Alzheimer's disease," and "Parkinson's disease." The literature search included the related articles with no restrictions on publication date.
Study Selection:
The primary references were Chinese and English articles including (a) original guidelines and expert consensuses of primary glaucoma, (b) reviews focusing on the differences between various versions of these guidelines and consensuses, and (c) papers about ocular-cranial pressure gradient theory and the relationship between glaucoma and CNS degenerative diseases.
Results:
The definitions and classifications of both primary open-angle glaucoma and primary angle-closure glaucoma differ between Chinese glaucoma consensuses and international primary glaucoma guidelines. Chinese definitions and classifications put more emphasis on the IOP, while international guidelines put more emphasis on the presence of optic neuropathy. The ocular-cranial pressure gradient theory and the research on the relationship between glaucoma and CNS degenerative diseases have provided new directions for exploring the pathogenesis of glaucoma.
Conclusions
As regards the definition and classification of primary glaucoma, we find that there are still some discrepancies between Chinese expert consensuses and international guidelines. Glaucoma is a disease with complex etiologies, while its common characteristic is a specific optic neuropathy. The current definition and understanding of glaucoma is an ongoing and evolving process, reflecting our latest available evidence on its pathogenesis. Chinese ophthalmology community may need to update our guidelines, accommodating these latest developments.
China
;
Glaucoma
;
diagnosis
;
physiopathology
;
Glaucoma, Angle-Closure
;
diagnosis
;
physiopathology
;
Glaucoma, Open-Angle
;
diagnosis
;
physiopathology
;
Humans
;
Intraocular Pressure
;
physiology
;
Ophthalmology
;
methods
3.Corneal Biomechanical Parameters and Asymmetric Visual Field Damage in Patients with Untreated Normal Tension Glaucoma.
Bai-Bing LI ; Yu CAI ; Ying-Zi PAN ; Mei LI ; Rong-Hua QIAO ; Yuan FANG ; Tian TIAN
Chinese Medical Journal 2017;130(3):334-339
BACKGROUNDHigh intraocular pressure (IOP) and low central corneal thickness (CCT) are important validated risk factors for glaucoma, and some studies also have suggested that eyes with more deformable corneas may be in higher risk of the development and worsening of glaucoma. In the present study, we aimed to evaluate the association between corneal biomechanical parameters and asymmetric visual field (VF) damage using a Corvis-ST device in patients with untreated normal tension glaucoma (NTG).
METHODSIn this observational, cross-sectional study, 44 newly diagnosed NTG patients were enrolled. Of these, 31 had asymmetric VF damage, which was defined as a 5-point difference between the eyes according to the Advanced Glaucoma Intervention Study scoring system. Corneal biomechanical parameters were obtained using a Corvis-ST device, such as time from start until the first and second applanation is reached (time A1 and time A2, respectively), cord length of the first and second applanation (length A1 and length A2, respectively), corneal speed during the first and second applanation (velocity A1 and velocity A2, respectively), time from start until highest concavity is reached (time HC), maximum amplitude at the apex of highest concavity (def ampl HC), distance between the two peaks at highest concavity (peak dist HC), and central concave curvature at its highest concavity (radius HC).
RESULTSTime A1 (7.19 ± 0.28 vs. 7.37 ± 0.41 ms, P = 0.010), length A1 (1.73 [1.70-1.76] vs. 1.78 [1.76-1.79] mm, P = 0.007), length A2 (1.58 [1.46-1.70] vs. 1.84 [1.76-1.92] mm, P< 0.001), peak dist HC (3.53 [3.08-4.00] vs. 4.33 [3.92-4.74] mm, P = 0.010), and radius HC (6.20 ± 0.69 vs. 6.59 ± 1.18 mm, P = 0.032) were significantly lower in the worse eyes than in the better eyes, whereas velocity A1 and def ampl HC were significantly higher (0.156 [0.149-0.163] vs. 0.145 [0.138-0.152] m/s, P = 0.002 and 1.19 ± 0.13 vs. 1.15 ± 0.13 mm, P = 0.005, respectively). There was no significant difference in time A2, velocity A2, and time HC between the two groups. In addition, no difference was observed in IOP, CCT, and axial length. In the univariate and multivariate analyses, some of the Corvis-ST parameters, including time A1 and def ampl HC, were correlated with known risk factors for glaucoma, and there was also a significant positive correlation between def ampl HC and age.
CONCLUSIONSThere were differences in dynamic corneal response parameters but not IOP or CCT between the paired eyes of NTG patients with asymmetric VF damage. We suggest that the shape of the cornea is more easily altered in the worse eyes of asymmetric NTG patients.
Aged ; Biomechanical Phenomena ; physiology ; Cornea ; metabolism ; physiology ; Cross-Sectional Studies ; Female ; Glaucoma ; metabolism ; physiopathology ; Humans ; Intraocular Pressure ; physiology ; Low Tension Glaucoma ; metabolism ; physiopathology ; Male ; Middle Aged ; Multivariate Analysis ; Prospective Studies ; Visual Fields ; physiology
4.Changes in Corneal Endothelial Cell after Ahmed Glaucoma Valve Implantation and Trabeculectomy: 1-Year Follow-up.
Min Su KIM ; Kyoung Nam KIM ; Chang sik KIM
Korean Journal of Ophthalmology 2016;30(6):416-425
PURPOSE: To compare changes in corneal endothelial cell density (CECD) after Ahmed glaucoma valve (AGV) implantation and trabeculectomy. METHODS: Changes in corneal endothelium in patients that underwent AGV implantation or trabeculectomy were prospectively evaluated. Corneal specular microscopy was performed at the central cornea using a non-contact specular microscope before surgery and 6 months and 12 months after surgery. The CECD, hexagonality of the endothelial cells, and the coefficient of variation of the cell areas were compared between the two groups. RESULTS: Forty eyes of 40 patients with AGV implantation and 28 eyes of 28 patients with trabeculectomy were studied. Intraocular pressure in the AGV implantation group was significantly higher than that in the trabeculectomy group (p < 0.001), but there was no significant difference in other clinical variables between the two groups. In the AGV implantation group, the mean CECD significantly decreased by 9.4% at 6 months and 12.3% at 12 months compared with baseline values (both, p < 0.001), while it decreased by 1.9% at 6 months and 3.2% at 12 months in the trabeculectomy group (p = 0.027 and p = 0.015, respectively). The changes at 6 months and 12 months in the AGV implantation group were significantly higher than those in the trabeculectomy group (p = 0.030 and p = 0.027, respectively). In the AGV implantation group, there was a significant decrease in the CECD between baseline and 6 months and between 6 months and 12 months (p < 0.001 and p = 0.005, respectively). However, in the trabeculectomy group, a significant decrease was observed only between baseline and 6 months (p = 0.027). CONCLUSIONS: Both the AGV implantation group and the trabeculectomy group showed statistically significant decreases in the CECD 1 year after surgery. The decrease in CECD in the AVG implantation group was greater and persisted longer than that in the trabeculectomy group.
Cell Count
;
Endothelium, Corneal/*pathology
;
Female
;
Follow-Up Studies
;
Glaucoma/diagnosis/physiopathology/*surgery
;
*Glaucoma Drainage Implants
;
Humans
;
*Intraocular Pressure
;
Male
;
Middle Aged
;
Postoperative Period
;
Prospective Studies
;
Prosthesis Implantation/*methods
;
Time Factors
;
Trabeculectomy/*methods
;
Treatment Outcome
5.Clinical and Anterior Segment Anatomical Features in Primary Angle Closure Subgroups Based on Configurations of Iris Root Insertion.
Ji Wook HONG ; Sung Cheol YUN ; Kyung Rim SUNG ; Jong Eun LEE
Korean Journal of Ophthalmology 2016;30(3):206-213
PURPOSE: To compare the clinical and anterior segment anatomical features in primary angle closure sub-groups based on configurations of iris root insertion. METHODS: Primary angle closure patients were imaged using anterior segment optical coherence tomography. Anterior chamber depth, iris curvature, iris thickness (IT) at the scleral spur and 500, 750, and 1,500 µm from the scleral spur (IT(0), IT(500), IT(750), and IT(1500)), lens vault, iris area, angle opening distance (AOD(500)), angle recess area (ARA(750)), and trabecular iris space area (TISA(750)) were measured. Iris root insertion was categorized into a non-basal insertion group (NBG) and basal insertion group (BG). RESULTS: In total, 43 eyes of 39 participants belonged to the NBG and 89 eyes of 53 participants to the BG. The mean age of participants was greater in the NBG than the BG (62.7 ± 5.7 vs. 59.8 ± 7.3 years, p = 0.043), and the baseline intraocular pressure was higher in the BG than the NBG (16.4 ± 4.4 vs. 14.9 ± 3.3 mmHg, p = 0.037). The BG showed a greater IT(0) (0.265 ± 0.04 vs. 0.214 ± 0.03 mm, p < 0.001) and iris area (1.59 ± 0.24 vs. 1.52 ± 0.27 mm2, p = 0.045), lower ARA(750) (0.112 ± 0.08 vs. 0.154 ± 0.08 mm2, p = 0.017) and AOD(500) (0.165 ± 0.07 vs. 0.202 ± 0.08 mm, p = 0.014) compared to the NBG. CONCLUSIONS: The BG had a narrower anterior chamber angle, thicker peripheral iris, and higher pretreatment intraocular pressure.
Anterior Eye Segment/*diagnostic imaging
;
Female
;
Glaucoma, Angle-Closure/diagnosis/physiopathology/*surgery
;
Gonioscopy
;
Humans
;
*Intraocular Pressure
;
Iridectomy/*methods
;
Iris/diagnostic imaging/*surgery
;
Lens, Crystalline/diagnostic imaging
;
Male
;
Middle Aged
;
Prospective Studies
;
Tomography, Optical Coherence/*methods
6.Performance of and Pressure Elevation Formed by Small-diameter Microtubes Used in Constant-flow Sets.
Sae Woon SOHN ; Myounggyu D NOH ; Jong Hyun LEE ; Kyoung Nam KIM ; Chang Sik KIM ; Byung Heon AHN
Korean Journal of Ophthalmology 2016;30(3):225-233
PURPOSE: We explored the performance of and pressure elevation caused by small-diameter microtubes used to reduce overfiltration. METHODS: Using a syringe pump-driven constant-flow setting (2 µL/min), pressures were measured for polytetrafluoroethylene (PTFE) microtubes 5 mm in length with inner diameters of 51, 64, and 76 µm and for polyether block amide (PEBAX) microtubes with an inner diameter of 76 µm. Experiments (using microtubes only) were initially performed in air, water, and enucleated pig eyes and were repeated under the same conditions using intraluminal 9/0 nylon stents. RESULTS: The pressures measured in air in 51-, 64-, and 76-µm-diameter PTFE microtubes differed significantly (22.1, 16.9, and 12.2 mmHg, respectively; p < 0.001), and that of the 76-µm-diameter PEBAX microtube was 15.8 mmHg (p < 0.001 compared to the 12.2 mmHg of the 76-µm-diameter PTFE microtube). The pressures measured in water also differed significantly among the three microtubes at 3.9, 3.0, and 1.4 mmHg, respectively, while that in the PEBAX microtube was 2.6 mmHg (all p < 0.001). Using the intraluminal stent, the pressure in water of the three different PTFE microtubes increased to 22.6, 18.0, and 4.1 mmHg, respectively, and that in the PEBAX microtube increased to 10.5 mmHg (all p < 0.001). Similar trends were evident when measurements were performed in pig eyes. CONCLUSIONS: Although microtubes of smaller diameter experienced higher pressure in air, reduction of the inner diameter to 51 µm did not adequately increase the pressure attained in water or pig eyes. Insertion of an intraluminal stent effectively elevated the latter pressures. PEBAX microtubes created higher pressures than did PTFE microtubes.
Animals
;
Disease Models, Animal
;
Glaucoma/physiopathology/*surgery
;
*Glaucoma Drainage Implants
;
Intraocular Pressure/*physiology
;
Ophthalmologic Surgical Procedures/*instrumentation
;
*Polytetrafluoroethylene
;
Prosthesis Design
;
Swine
7.Macular Ganglion Cell Layer Assessment to Detect Glaucomatous Central Visual Field Progression.
Haein MOON ; Jin Young LEE ; Kyung Rim SUNG ; Jong Eun LEE
Korean Journal of Ophthalmology 2016;30(6):451-458
PURPOSE: To investigate the use of ganglion cell inner plexiform layer (GC-IPL) thickness, as measured by spectral domain optical coherence tomography, to detect central visual field (VF) progression. METHODS: This study included 384 eyes from 384 patients (219 preperimetric and 165 perimetric glaucomatous eyes; average follow-up, 4.3 years). Photographic assessment of retinal nerve fiber layer (RNFL) and serial VF analysis were performed to detect glaucoma progression in the central (within 10°) area. Study inclusion required at least five serial spectral domain optical coherence tomography exams at different visits. The long-term test-retest variability of average GC-IPL thicknesses was calculated in 110 stable preperimetric glaucomatous eyes. The sensitivity and specificity of GC-IPL measurements for the detection of central VF progression were calculated in an event-based analysis using the calculated variability as a cut-off and were compared with those of central RNFL photographic assessment. RESULTS: The intersession test-retest variability, defined as the 95% confidence interval, was 1.76 µm for average GC-IPL thickness. The sensitivity and specificity of the average GC-IPL thickness for detecting central VF progression were 60.7% and 78.9%, respectively. Among six sectors, the inferonasal GC-IPL sector showed the highest sensitivity (53.6%). The sensitivity of the ≥1 sector GC-IPL to detect central VF progression was significantly higher than that of central RNFL photographic progression (p = 0.013). Other GC-IPL parameters showed comparable sensitivity and specificity to detect central VF progression compared with RNFL photographic progression. CONCLUSIONS: Serial GC-IPL measurements show comparable performance in the detection of central glaucomatous VF progression to RNFL photographic assessment.
Disease Progression
;
Female
;
Follow-Up Studies
;
Glaucoma/*diagnosis/physiopathology
;
Humans
;
*Intraocular Pressure
;
Macula Lutea/*diagnostic imaging
;
Male
;
Middle Aged
;
ROC Curve
;
Retinal Ganglion Cells/*pathology
;
Retrospective Studies
;
Time Factors
;
Tomography, Optical Coherence/*methods
;
*Visual Fields
8.Long-term Results from Cyclocryotherapy Applied to the 3O'clock and 9O'clock Positions in Blind Refractory Glaucoma Patients.
Byoung Seon KIM ; Young Jun KIM ; Seong Wook SEO ; Ji Myong YOO ; Seong Jae KIM
Korean Journal of Ophthalmology 2015;29(1):47-52
PURPOSE: To report the long-term follow-up results after cyclocryotherapy, applied to the 3-o'clock and 9-o'clock positions in blind refractory glaucoma patients. METHODS: We retrospectively reviewed the charts of 19 blind patients, and a total of 20 eyes with refractory glaucoma who were treated with cyclocryotherapy. Cyclocryotherapy treatments were performed using a retinal cryoprobe. The temperature of each cyclocryotherapy spot was -80degrees C and each spot was maintained in place for 60 seconds. Six cyclocryotherapy spots were placed in each quadrant, including the 3-o'clock and 9-o'clock positions. RESULTS: The mean baseline pretreatment intraocular pressure (IOP) in all eyes was 50.9 ± 12.5 mmHg, which significantly decreased to a mean IOP at last follow-up of 14.1 ± 7.1 mmHg (p < 0.001). The mean number of antiglaucoma medications that patients were still taking at last follow-up was 0.3 ± 0.6. Devastating post-procedure phthisis occurred in only one eye. CONCLUSIONS: Cyclocryotherapy, performed at each quadrant and at the 3-o'clock and 9-o'clock position, is an effective way to lower IOP and, thus, is a reasonable treatment option for refractory glaucoma patients who experience with ocular pain and headaches.
Adult
;
Aged
;
Aged, 80 and over
;
Blindness/etiology/*surgery
;
Cryosurgery/*methods
;
Female
;
Follow-Up Studies
;
Glaucoma/complications/physiopathology/*surgery
;
Humans
;
Intraocular Pressure/*physiology
;
Male
;
Middle Aged
;
Retrospective Studies
;
Time Factors
;
Treatment Outcome
;
*Visual Acuity
9.Comparison of Clinical Characteristics and Progression Rates of Bilaterally and Unilaterally Progressing Glaucoma.
Daun JEONG ; Kyung Rim SUNG ; Jung Hwa NA
Korean Journal of Ophthalmology 2015;29(1):40-46
PURPOSE: To compare the clinical characteristics of unilaterally progressing glaucoma (UPG) and simultaneously bilaterally progressing glaucoma (BPG) in medically treated cases. METHODS: Primary open angle glaucoma patients were classified as having UPG or BPG according to an assessment of optic disc and retinal nerve fiber layer photographs and visual field analysis. Risk factors including the presence of systemic diseases (hypertension, diabetes, cerebrovascular accident, migraine, and dyslipidema) were compared between the UPG and BPG groups. Baseline characteristics and pre- and post-treatment intraocular pressure (IOP) were compared between the progressing eye (PE) and the non-progressing eye (NPE) within the same patient in the UPG group and between the faster progressing eye and the slower progressing eye in the BPG group. RESULTS: Among 343 patients (average follow-up period of 4.2 years), 43 were categorized into the UPG group and 31 into the BPG group. The prevalence of all analyzed systemic diseases did not differ between the two groups. PEs in the UPG group had more severe pathology in terms of baseline visual field parameters than NPEs (mean deviation -6.9 ± 5.7 vs. -2.9 ± 3.9 dB, respectively; p < 0.001). However, baseline IOP, mean follow-up IOP, and other clinical characteristics were not significantly different between the PE and the NPE in the UPG group. The progression rate was significantly higher in the faster progressing eye in patients with BPG than in the PE for patients with UPG (-3.43 ± 3.27 vs. -0.70 ± 1.26 dB/yr, respectively; p = 0.014). CONCLUSIONS: There were no significant differences in the prevalence of systemic diseases between the UPG and BPG groups. Simultaneously bilaterally progressing patients showed much faster progression rates than those with a unilaterally progressing eye.
Disease Progression
;
Female
;
Follow-Up Studies
;
Glaucoma, Open-Angle/*diagnosis/physiopathology
;
Humans
;
Intraocular Pressure/*physiology
;
Male
;
Middle Aged
;
Optic Disk/*pathology
;
Retina/*pathology
;
Retrospective Studies
;
Time Factors
;
Visual Fields/*physiology
10.Detecting the Progression of Normal Tension Glaucoma: A Comparison of Perimetry, Optic Coherence Tomography, and Heidelberg Retinal Tomography.
Jae Yoon YOON ; Jong Kyung NA ; Chan Kee PARK
Korean Journal of Ophthalmology 2015;29(1):31-39
PURPOSE: We compared the abilities of Stratus optical coherence tomography (OCT), Heidelberg retinal tomography (HRT) and standard automated perimetry (SAP) to detect the progression of normal tension glaucoma (NTG) in patients whose eyes displayed localized retinal nerve fiber layer (RNFL) defect enlargements. METHODS: One hundred four NTG patients were selected who met the selection criteria: a localized RNFL defect visible on red-free fundus photography, a minimum of five years of follow-up, and a minimum of five reliable SAP, Stratus OCT and HRT tests. Tests which detected progression at any visit during the 5-year follow-up were identified, and patients were further classified according to the state of the glaucoma using the mean deviation (MD) of SAP. For each test, the overall rates of change were calculated for parameters that differed significantly between patients with and without NTG progression. RESULTS: Forty-seven (45%) out of 104 eyes displayed progression that could be detected by red-free fundus photography. Progression was detected in 27 (57%) eyes using SAP, 19 (40%) eyes using OCT, and 17 (36%) eyes using HRT. In early NTG, SAP detected progression in 44% of eyes, and this increased to 70% in advanced NTG. In contrast, OCT and HRT detected progression in 50 and 7% of eyes during early NTG, but only 30 and 0% of eyes in advanced NTG, respectively. Among several parameters, the rates of change that differed significantly between patients with and without progression were the MD of SAP (p = 0.013), and the inferior RNFL thickness (p = 0.041) and average RNFL thickness (p = 0.032) determined by OCT. CONCLUSIONS: SAP had a higher detection rate of NTG progression than other tests, especially in patients with advanced glaucoma, when we defined progression as the enlargement of a localized RNFL defect. The rates of change of the MD of SAP, inferior RNFL thickness, and average RNFL thickness differed between NTG patients with and without progression.
Disease Progression
;
Female
;
Humans
;
Intraocular Pressure/*physiology
;
Low Tension Glaucoma/*diagnosis/physiopathology
;
Male
;
Middle Aged
;
Retina/*pathology
;
Tomography, Optical Coherence/*methods
;
Visual Field Tests/*methods
;
Visual Fields/*physiology

Result Analysis
Print
Save
E-mail