1.Current status of indoor microbial pollution and evaluation of air purifier effectiveness in Xi'an
Ling CHANG ; Feng ZHANG ; Ping LIU ; Fan GAO ; Jian HU ; Ge MI ; Yonggang ZHAO ; Dong LIU ; Qian LIU ; Xinmiao LIU ; Xiaoyan WU ; Jinlong MA
Journal of Public Health and Preventive Medicine 2024;35(6):59-62
Objective To investigate the current situation and health effects of indoor microbial pollution in Xi'an, to analyze the purification effect of air purifiers on indoor microbial pollution, and to provide reference for improving the indoor environment. Methods Through stratified random sampling, 20 families from rural areas and 20 families from upwind and downwind urban areas respectively were selected from Xi'an. Data was collected by questionnaire surveys and on-site environmental sampling. Non-parametric analysis and correlation analysis were used for statistical analysis. Results Overall, the standard-exceeding rate of total count of bacteria was 5.00%. The medians of the total count of bacteria and fungi were 312.50 cfu/m3 and 260.00 cfu/m3, respectively. In terms of health effects, the correlation between rhinitis and cold with total bacterial count was statistically significant (P<0.05), with the correlation coefficients of 0.182 and 0.223, respectively. Purification effect of air purifiers on microbial pollution was statistically significant (P<0.05). After opening for 2 hours, the total numbers of bacteria and fungi decreased significantly. Conclusion The occurrence risk of colds and rhinitis is increased by indoor microbial pollution. Air purifiers have a certain effect on decreasing the total number of bacteria and fungi. It is recommended to use air purifiers with high CADR of particulate matter, double-layer filter and sterilization and dehumidification function, and replace the filters regularly to reduce indoor microbiological contamination.
2.Bioequivalence study of sidenafil citrate tablets in Chinese healthy subjects
Xiao-Bin LI ; Lu CHEN ; Xiu-Jun WU ; Yu-Xin GE ; Wen-Chao LU ; Ting XIAO ; He XIE ; Hua-Wei WANG ; Wen-Ping WANG
The Chinese Journal of Clinical Pharmacology 2024;40(3):430-434
Objective To evaluate the bioequivalence of oral sidenafil citrate tablets manufactured(100 mg)test preparations and reference preparations in healthy subjects under fasting and fed conditions.Methods Using a single-dose,randomized,open-lable,two-period,two-way crossover design,36 healthy subjects respectively for fasting and fed study were enrolled,and randomized into two groups to receive a single dose of test 100 mg with 7-day washout period.Plasma concentration of sidenafil and N-demethylsildenafil was determined by liquid chromatography-tandem mass spectrometry(LC-MS/MS)method.The pharmacokinetic parameters were calculated by Analyst 1.6.3(AB Scie)using non-compartmental model,and bioequivalence evaluation was performed for the two preparations.Relevant safety evaluations were performed during the trial.Results The main pharmacokinetic parameters of sidenafil after a single oral dose of sidenafil citrate tablets under fasting condition for test and reference were as follows:Cmax were(494.69±230.94)and(558.78±289.83)ng·mL-1,AUC0-t were(1 336.21±509.78)and(1 410.82±625.99)h·ng·mL-1,AUC0-were(1 366.49±512.16)and(1 441.84±628.04)h·ng·mL-1,respectively.The main pharmacokinetic parameters of sidenafil under fed condition for T and R were as follows:Cmax were(381.89±126.53)and(432.47±175.91)ng·mL-1,AUC0-t were(1 366.34±366.99)and(1 412.76±420.37)h·ng·mL-1,AUC0-were(1 403.28±375.32)and(1 454.13±429.87)h·ng·mL-1,respectively.The results demonstrated the bioequivalence of sidenafil citrate tablets between T and R.The incidence of adverse events in fasting and fed tests were 33.33%and 25.00%,respectively.No serious adverse event was reported.Conclusion The test and reference formulation of sidenafil citrate tablets were equivalent and was safe.
3.Bioequivalence study of buspirone hydrochloride tablets in Chinese healthy subjects
Ping LU ; Rui WANG ; Hui-Hui WU ; Hai-Yan LIU ; Ge-Fei HE ; Shun-Zhi ZHANG ; Wei WU
The Chinese Journal of Clinical Pharmacology 2024;40(5):723-727
Objective To study the pharmacokinetic characteristics of buspirone hydrochloride tablets in healthy adult populations under conditions of fasting and postprandial administration.Methods A single-center,randomized,three-cycle partially repeated crossover trial design was adopted,and 36 subjects were enrolled on fasting/postprandial,one tablet of the test preparation was taken in one cycle,one tablet of reference preparation(5 mg of buspirone tablets)was taken once in each of 2 cycles,the drug concentration of buspirone in plasma was determined by liquid chromatography-tandem mass spectrometry,and the pharmacokinetic parameters were calculated by WinNonlin software.Results Main pharmacokinetics of buspirone after oral administration of test and reference preparations in fasting group,the Cmax was(285.72±286.08)and(308.94±341.03)pg·mL-1;AUC0-t were(577.09±491.10)and(618.62±642.56)pg·mL-1·h;AUC0-∞ were(586.85±510.04)and(655.92±687.95)pg·mL-1·h;tmax was 0.75(0.33-4.00)and 0.75(0.33-1.75)h.Main pharmacokinetics of buspirone after oral administration of test and reference preparations in the postprandial group,the Cmax were(676.36±603.64)and(760.33±610.27)pg·mL-1;AUC0-t were(1 755.58±1 001.69)and(1 743.00±1 073.33)pg·h·mL-1;AUC0-∞ were(1 839.97±1 044.60)and(1 818.00±1 106.95)pg·mL-1·h;tmax was 1.25(0.25-4.50)and 1.00(0.25-3.50)h.The 90%confidence intervals of the AUC0-t and AUC0-∞ geometric mean ratios of the test preparation and the reference preparation in the fasting test and the postprandial test all fell between 80.00%and 125.00%,and the 95%upper confidence limit of of Cmax was ≤0 and geometric mean ratios point estimates fall between 80.00%and 125.00%.Conclusion Two kinds of buspirone hydrochloride are bioequivalent in Chinese healthy adult subject.
4.Relationship between Phenotypic Changes of Dendritic Cell Subsets and the Onset of Plateau Phase during Intermittent Interferon Therapy in Patients with CHB
Liu YANG ; Yu Shi WANG ; Ting Ting JIANG ; Wen DENG ; Min CHANG ; Ling Shu WU ; Hua Wei CAO ; Yao LU ; Ge SHEN ; Yu Ru LIU ; Jiao Yuan GAO ; Jiao Meng XU ; Ping Lei HU ; Lu ZHANG ; Yao XIE ; Hui Ming LI
Biomedical and Environmental Sciences 2024;37(3):303-314
Objective This study aimed to evaluate whether the onset of the plateau phase of slow hepatitis B surface antigen decline in patients with chronic hepatitis B treated with intermittent interferon therapy is related to the frequency of dendritic cell subsets and expression of the costimulatory molecules CD40,CD80,CD83,and CD86. Method This was a cross-sectional study in which patients were divided into a natural history group(namely NH group),a long-term oral nucleoside analogs treatment group(namely NA group),and a plateau-arriving group(namely P group).The percentage of plasmacytoid dendritic cell and myeloid dendritic cell subsets in peripheral blood lymphocytes and monocytes and the mean fluorescence intensity of their surface costimulatory molecules were detected using a flow cytometer. Results In total,143 patients were enrolled(NH group,n = 49;NA group,n = 47;P group,n = 47).The results demonstrated that CD141/CD1c double negative myeloid dendritic cell(DNmDC)/lymphocytes and monocytes(%)in P group(0.041[0.024,0.069])was significantly lower than that in NH group(0.270[0.135,0.407])and NA group(0.273[0.150,0.443]),and CD86 mean fluorescence intensity of DNmDCs in P group(1832.0[1484.0,2793.0])was significantly lower than that in NH group(4316.0[2958.0,5169.0])and NA group(3299.0[2534.0,4371.0]),Adjusted P all<0.001. Conclusion Reduced DNmDCs and impaired maturation may be associated with the onset of the plateau phase during intermittent interferon therapy in patients with chronic hepatitis B.
5.Association of Cytokines with Clinical Indicators in Patients with Drug-Induced Liver Injury
Hua Wei CAO ; Ting Ting JIANG ; Ge SHEN ; Wen DENG ; Yu Shi WANG ; Yu Zi ZHANG ; Xin Xin LI ; Yao LU ; Lu ZHANG ; Yu Ru LIU ; Min CHANG ; Ling Shu WU ; Jiao Yuan GAO ; Xiao Hong HAO ; Xue Xiao CHEN ; Ping Lei HU ; Jiao Meng XU ; Wei YI ; Yao XIE ; Hui Ming LI
Biomedical and Environmental Sciences 2024;37(5):494-502
Objective To explore characteristics of clinical parameters and cytokines in patients with drug-induced liver injury(DILI)caused by different drugs and their correlation with clinical indicators. Method The study was conducted on patients who were up to Review of Uncertainties in Confidence Assessment for Medical Tests(RUCAM)scoring criteria and clinically diagnosed with DILI.Based on Chinese herbal medicine,cardiovascular drugs,non-steroidal anti-inflammatory drugs(NSAIDs),anti-infective drugs,and other drugs,patients were divided into five groups.Cytokines were measured by Luminex technology.Baseline characteristics of clinical biochemical indicators and cytokines in DILI patients and their correlation were analyzed. Results 73 patients were enrolled.Age among five groups was statistically different(P=0.032).Alanine aminotransferase(ALT)(P=0.033)and aspartate aminotransferase(AST)(P=0.007)in NSAIDs group were higher than those in chinese herbal medicine group.Interleukin-6(IL-6)and tumor necrosis factor alpha(TNF-α)in patients with Chinese herbal medicine(IL-6:P<0.001;TNF-α:P<0.001)and cardiovascular medicine(IL-6:P=0.020;TNF-α:P=0.001)were lower than those in NSAIDs group.There was a positive correlation between ALT(r=0.697,P=0.025),AST(r=0.721,P=0.019),and IL-6 in NSAIDs group. Conclusion Older age may be more prone to DILI.Patients with NSAIDs have more severe liver damage in early stages of DILI,TNF-α and IL-6 may partake the inflammatory process of DILI.
6.Harmonization of 18F-FDG PET brain imaging based on ComBat method: a pilot study
Fangyang JIAO ; Dan WANG ; Yuhua ZHU ; Jiaying LU ; Zizhao JU ; Qian XU ; Jingjie GE ; Tao HUA ; Ping WU ; Kuangyu SHI ; Yihui GUAN ; Chuantao ZUO
Chinese Journal of Nuclear Medicine and Molecular Imaging 2024;44(7):412-416
Objective:To perform harmonization based on the ComBat method for PET brain imaging scanned by different types of scanners from the same manufacturer and explored its effect on center effect.Methods:The three-dimensional (3D) Hoffman brain model was scanned by two different PET/CT instruments (Siemens Biograph64 TruePoint and Biograph128 mCT). Fourteen healthy subjects (8 males, 6 females, age: (57.7±9.5) years) underwent 18F-FDG PET/CT on Siemens Biograph64 TruePoint and 12 healthy subjects (9 males, 3 females, age: (55.8±10.5) years) underwent 18F-FDG PET/CT on Siemens Biograph128 mCT (all from Huashan Hospital, Fudan University; from November 2020 to March 2023). The whole brain was divided into 116 brain regions based on the anatomical automatic labeling (AAL) brain template. The ComBat method was applied to harmonized the PET data from brain model and healthy subjects. Mann-Whitney U test was performed on the radioactive counts and SUV ratios (SUVR) before and after homogenization acquired by both PET/CT instruments. Voxel-based statistical parametric mapping (SPM) independent-sample t test was also performed on data of healthy subjects. Results:In 3D Hoffman brain model, radioactivity counts (5 590.33(4 961.67, 6 102.95) vs 6 116.03(5 420.97, 6 660.66); z=-9.35, P<0.001) and SUVR (1.35(1.19, 1.47) vs 1.37(1.21, 1.49); z=-3.63, P<0.001) were significantly different between the two PET/CT scanners before harmonization and not after harmonization (radioactivity counts: 5 845.95(5 192.68, 6 378.63) vs 5 859.17(5 193.84, 6 380.52); SUVR: 1.35(1.20, 1.48) vs 1.36(1.20, 1.49); both z=-0.68, both P=0.498). In the healthy subjects, radioactive counts in 19 brain regions (12 422.78(11 181.60, 13 424.28)-18 166.40(15 882.80, 18 666.27); z values: from -3.24 to -2.06, all P<0.05) and SUVR in 40 brain regions (1.46(1.41, 1.52)-2.28(2.16, 2.36); z values: from -3.65 to -1.70, all P<0.05) were significantly different between the two scanners before harmonization, while after homogenization there were no statistical differences for all 116 brain regions (radioactivity counts: 9 243.55(8 502.38, 9 854.87)-20 419.60(19 931.51, 21 179.43); z values: from -0.72 to 0, all P>0.05; SUVR: 1.04(1.01, 1.09)-2.32(2.24, 2.40); z values: from -0.82 to 0, all P>0.05). SPM showed that significant differences of glucose metabolism in the cerebral cortex, basal ganglia, midbrain and cerebellum were found in healthy subjects between the two PET/CT scanners before homogenization, and brain regions with obvious differences reduced after homogenization. Conclusion:ComBat harmonization method is efficient at removing the center effect among different types of PET/CT scanners from the same manufacturer and may provide a simple and easy-to-implement homogenization for multicenter brain imaging studies.
7.Application of China-made Toumai? Robot in laparoscopic radical prostatectomy
Zhi-Feng WEI ; Yu-Hao CHEN ; Ze-Peng ZHU ; Qi JIANG ; Yu XIONG ; Feng-Feng LU ; Zhen-Qian SONG ; Bin JIANG ; Xiao-Feng ZHU ; Tian-Hao FENG ; Xiao-Feng XU ; Gang YANG ; Wu WEI ; Ai-Bing YAO ; Jing-Ping GE
National Journal of Andrology 2024;30(8):696-700
Objective:To evaluate the safety and efficiency of China-made Toumai Robot-assisted laparoscopic radical prosta-tectomy(LRP).Methods:This study included 40 cases of PCa treated from January 2023 to May 2023 by robot-assisted LRP with preservation of the bladder neck and maximal functional urethral length,15 cases with the assistance of Toumai Robot(the TMR group)and the other 25 with the assistance of da Vinci Robot as controls(the DVR group).We recorded the docking time,laparo-scopic surgery time,vesico-urethral anastomosis time,intraoperative blood loss and postoperative urinary continence,and compared them between the two groups.Results:Operations were successfully completed in all the cases.No statistically significant differ-ences were observed between the TMR and DVR groups in the docking time(6 min vs 5 min,P>0.05)or intraoperative blood loss(200 ml vs 150 ml,P>0.05).The TMR group,compared with the DVR group,showed a significantly longer median laparoscopic surgery time(146 min vs 130 min,P<0.05)and median vesico-urethral anastomosis time(19 min vs 16 min,P<0.05).There were no statistically significant differences between the TMR and DVR groups in the rates of urinary continence recovery immediately af-ter surgery(60.0%[9/15]vs 64.0%[16/25],P>0.05)or at 1 month(80.0%[12/15])vs(76.0%[19/25],P>0.05),3 months(93.3%[14/15])vs(92.0%[23/25],P>0.05)and 6 months postoperatively(100%[15/15])vs(96%[24/25],P>0.05).Conclusion:China-made Toumai? Robot surgical system is safe and reliable for laparoscopic radical prosta-tectomy,with satisfactory postoperative recovery of urinary continence.
8.Pretreatment integrase strand transfer inhibitor resistance in Tianjin, China.
Huan XIA ; Zhangwen GE ; Defa ZHANG ; Yue WU ; Ping MA
Chinese Medical Journal 2023;136(22):2735-2737
Humans
;
HIV Infections
;
HIV-1
;
Integrases
;
China
;
Drug Resistance, Viral
;
Mutation
9.Preparation and evaluation of Indigo Naturalis dry suspension based on powder surface modification
Sheng-jie HUANG ; Juan SU ; Chun-li GE ; Jin XIE ; Zhi-ping GUO ; Ming YANG ; Zhen-feng WU ; Ding-kun ZHANG ; Li HAN
Acta Pharmaceutica Sinica 2023;58(5):1347-1353
A dry suspension of Indigo Naturalis (IN) based on lactose-IN composite particles was designed by powder modification technology to meet the clinical needs of IN. The contact angle was used as an evaluation index to investigate the effects of the type of modifier lactose, the amount of lactose, and the co-grinding time of lactose and IN on the hydrophilicity of IN. The difference between IN before and after modification was compared through physical properties such as particle size and scanning electron microscope, as well as hydrophilic properties such as surface free energy and multiple light scattering. The optimal process of lactose-IN composite particles is as follows: after lactose is ground alone for 2 minutes, it is co-ground with IN at a ratio of 1∶1 for 6 minutes. The results of the investigation of powder properties show that the particle size
10.Quality Evaluation of Temporomandibular Joint Images from 3 High-resolution Dynamic Sequences.
Ping GAO ; Chuan JIN ; Lei WAGN ; Tao WU ; Juan LI ; Xin GAO ; Yu CHEN ; Qi WANG ; Yu-Hong WANG ; Hua-Dan XUE ; Zheng-Yu JIN
Acta Academiae Medicinae Sinicae 2023;45(1):50-56
Objective To compare the image quality of three high-resolution dynamic MRI methods for evaluating the motion of temporomandibular joint disc and condyle. Methods Twenty-five patients with suspected temporomandibular joint disorders were examined by single-shot fast spin-echo (SSFSE),fast imaging employing steady-state acquisition (FIESTA),and spoiled gradient echo (SPGR) on the oblique sagittal position.Two radiologists performed subjective and objective evaluation on the images with double-blind method.The subjective evaluation included the signal intensity of mandibular condyle,articular disc,soft tissue around articular disc,and lateral pterygoid muscle,the contrast between articular disc and condyle,the contrast between articular disc and surrounding soft tissue,condylar motion,and disc movement.The objective evaluation indexes included image signal intensity,signal-to-noise ratio (SNR),and contrast-to-noise ratio (CNR).The subjective and objective indexes of the image quality were compared between the three sequences. Results The SSFSE sequence had lower signal intensity of articular disc and higher signal intensity of condyle and surrounding soft tissue than FIESTA and SPGR sequences (all P<0.001).The SPGR sequence showed higher signal intensity of lateral pterygoid muscle than the SSFSE and FIESTA sequences (P=0.017,P<0.001).Among the three sequences,SSFSE sequence showed the clearest articular disc structure (χ2=41.952,P<0.001),the strongest contrast between articular disc and condyle (χ2=35.379,P<0.001),the strongest contrast between articular disc and surrounding soft tissue (χ2=27.324,P<0.001),and the clearest movement of articular disc (χ2=44.655,P<0.001).SSFSE and FIESTA sequences showed higher proportion of disc displacement and reduction than SPGR sequence (all P<0.001).The CNR (χ2=21.400,P<0.001),SNR (χ2=34.880,P<0.001),and condyle signal intensity (F=337.151,P<0.001) demonstrated differences among SSFSE,FIESTA,and SPGR sequences.The CNR of SSFSE sequence was higher than that of FIESTA sequence (P<0.001),while it had no significant difference between SSFSE and SPGR sequences (P=0.472).In addition,the SSFSE sequence had higher SNR and signal intensity than FIESTA and SPGR sequences (all P<0.001). Conclusion The best image quality can be observed from SSFSE sequence where both the structure and movement of temporomandibular joint are well displayed.Therefore,SSFSE is preferred for the examination of temporomandibular joint movement.
Humans
;
Temporomandibular Joint/diagnostic imaging*
;
Motion
;
Plastic Surgery Procedures


Result Analysis
Print
Save
E-mail