1.Study on toxicity-reducing and efficacy-enhancing effects of Polygala tenuifolia compatibility on sand-ironing Strychnos nux-vomica
Yi SUI ; Guo FENG ; Gang LIU ; Keyan LIU ; Xuehao WEI ; Minggang TENG ; Wei LI ; Caiyao HAN ; Yan LEI
China Pharmacy 2025;36(10):1197-1201
OBJECTIVE To explore the effects of Polygala tenuifolia compatibility on toxicity, anti-inflammatory and analgesic efficacy of sand-ironing Strychnos nux-vomica (SS). METHODS The preparation of SS single decoction, SS-P. tenuifolia core-removed (PC) (1∶2.5) or (1∶5) combined decoction, and SS-PC (1∶5) mixture were carried out to investigate their median lethal dose (LD50). Using aspirin as positive control, the number of writhing movements, analgesic rate, pain latency, ear swelling degree and inflammation inhibition rate induced by the above-mentioned medicinal liquids in mice were compared. The contents of the active and toxic components, strychnine and brucine, in the above-mentioned medicinal liquids were also determined. RESULTS The LD50 values of SS single decoction, SS-PC (1∶2.5) combined decoction, SS-PC (1∶5) combined decoction and SS- PC (1∶5) mixture were 302.00, 614.47, 1 445.44 and 1 778.28 mg/kg, respectively. Compared with control group, the number of writhing movements and ear swelling degree in the mice of the above-mentioned medicinal liquid groups were reduced or decreased significantly (P<0.05 or P<0.01); pain latency [at 90 and 120 minutes in the SS single decoction group, at 60 and 90 minutes in the SS-PC (1∶2.5) combined decoction group, and at 60,90, 120 minutes in the SS-PC (1∶5) combined decoction group and SS-PC (1∶5) mixture group] was significantly prolonged (P<0.05 or P<0.01); analgesic rates of the respective medicinal liquids were 39.30%, 70.87%, 80.00% and 82.46%, and inflammation inhibition rates were 38.08%,TD 57.89%, 76.47% and 50.46%; analgesic and anti-inflammatory effects of combined decoction and mixture were generally better than those of the single decoction (P<0.05 or P<0.01). In the above-mentioned four medicinal liquids, the total contents of strychnine were 0.71%, 0.42%, 0.47% and 0.64%, and the total contents of brucine were 0.88%, 0.63%, 0.57% and 0.88%, respectively. CONCLUSIONS The combination of P. tenuifolia can reduce the toxicity of SS and enhance its anti-inflammatory and analgesic effects. Moreover, there is a tendency for the toxicity-reducing and efficacy-enhancing effects to increase with the increasing dosage of P. tenuifolia. Additionally, the combined decoction of SS and P. tenuifolia can reduce the contents of the active and toxic components, strychnine and brucine, in SS.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Efficacy and safety of proximal gastrectomy versus total gastrectomy for Siewert type Ⅱ and Ⅲ adenocarcinoma of the esophagogastric junction: A systematic review and meta-analysis
Yingjie LU ; Ziqiang HONG ; Hongchao LI ; Gang JIN ; Wenhao WANG ; Yi YANG ; Bin LIU ; Zijiang ZHU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(05):693-699
Objective To systematically evaluate the efficacy and safety of proximal gastrectomy (PG) versus total gastrectomy (TG) for the treatment of Siewert type Ⅱ/Ⅲ adenocarcinoma of the esophagogastric junction (AEG). Methods PubMed, The Cochrane Library, Web of Science, EMbase, CNKI, Wanfang, and VIP databases were searched for literature comparing the efficacy and safety of PG and TG for the treatment of Siewert type Ⅱ/Ⅲ AEG. The search period was from database inception to March 2023. Meta-analysis was performed using Review Manager 5.4 software. Results A total of 23 articles were included, including 16 retrospective cohort studies, 5 prospective cohort studies, and 2 randomized controlled trials. The total sample size was 2 826 patients, with 1 389 patients undergoing PG and 1 437 patients undergoing TG. Meta-analysis results showed that compared with TG, PG had less intraoperative blood loss [MD=−19.85, 95%CI (−37.20, −2.51), P=0.02] and shorter postoperative hospital stay [MD=−1.23, 95%CI (−2.38, −0.08), P=0.04]. TG had a greater number of lymph nodes dissected [MD=−6.20, 95%CI (−7.68, −4.71), P<0.001] and a lower incidence of reflux esophagitis [MD=3.02, 95%CI (1.24, 7.34), P=0.01]. There were no statistically significant differences between the two surgical approaches in terms of operative time, postoperative survival rate (1-year, 3-year, 5-year), and postoperative overall complications (P>0.05). Conclusion PG has advantages in terms of intraoperative blood loss and postoperative hospital stay, while TG has advantages in terms of the number of lymph nodes dissected and the incidence of reflux esophagitis. There is no significant difference in long-term survival between the two surgical approaches.
8.Inhibition of Oxidative Stress of Sciatic Nerve in Diabetic Rats by Tangbikang Granules Regulating AMPK/PGC-1α/SIRT3 Signaling Pathway
Gang LIU ; Yaqi ZHANG ; Lingling QIN ; Chengfei ZHANG ; Qiue ZHANG ; Huizhong BAI ; Yi ZHAO ; Tonghua LIU ; Xiaohong MU
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(6):75-82
ObjectiveTo investigate the effect of Tangbikang granules on oxidative stress of sciatic nerve in diabetic rats by regulating adenylate activated protein kinase/peroxisome proliferator-activated receptor γ coactivator-1α/mitochondrial Sirtuins 3 (AMPK/PGC-1α/SIRT3) signaling pathway. MethodThe spontaneous obesity type 2 diabetes model was established using ZDF rats. After modeling, they were randomly divided into high, medium, and low dose Tangbikang granule groups (2.5, 1.25, 0.625 g·kg-1·d-1) and lipoic acid group (0.026 8 g·kg-1·d-1), and the normal group was set up. The rats were administered continuously for 12 weeks after modeling. The blood glucose of rats was detected before intervention and at 4, 8, 12 weeks after intervention. At the 12th week, motor nerve conduction velocity (MNCV), sensory nerve conduction velocity (SNCV), nerve blood flow velocity, mechanical pain threshold, and thermal pain threshold were detected. The sciatic nerve was taken for hematoxylin-eosin (HE) staining to observe the tissue morphology. The ultrastructure of the sciatic nerve was observed by transmission electron microscope. The expression levels of superoxide dismutase (SOD), malondialdehyde (MDA), interleukin-1β (IL-1β), and tumor necrosis factor-α (TNF-α) in sciatic nerve were determined by enzyme-related immunosorbent assay (ELISA). The mRNA expressions of AMPKα, AMPKβ, PGC-1α, and SIRT3 in sciatic nerve were determined by real-time polymerase chain reaction (Real-time PCR). ResultCompared with the normal group, fasting blood glucose in the model group was increased at each time point (P<0.01). The mechanical pain threshold was decreased (P<0.05), and the incubation time of the hot plate was extended (P<0.01). MNCV, SNCV, and nerve blood flow velocity decreased (P<0.05). The expression level of SOD was decreased (P<0.01). The expression levels of MDA, IL-1β, and TNF-α were increased (P<0.01). The mRNA expression levels of AMPKα, AMPKβ, PGC-1α, and SIRT3 were decreased (P<0.01). The structure of sciatic nerve fibers in the model group was loose, and the arrangement was disordered. The demyelination change was obvious. Compared with the model group, the fasting blood glucose of rats in the high dose Tangbikang granule group was decreased after the intervention of eight weeks and 12 weeks (P<0.01). The mechanical pain threshold increased (P<0.05). The incubation time of the hot plate was shortened (P<0.01). MNCV, SNCV, and Flux increased (P<0.05). The expression level of SOD was increased (P<0.01). The expression levels of MDA, IL-1β, and TNF-α were decreased (P<0.01). The mRNA expression levels of AMPKα, AMPKβ, PGC-1α, and SIRT3 were increased (P<0.01). The sciatic nerve fibers in the high-dose Tangbikang granule group were tighter and more neatly arranged, with only a few demyelinating changes. The high, medium, and low dose Tangbikang granule groups showed a significant dose-effect trend. ConclusionTangbikang granules may improve sciatic nerve function in diabetic rats by regulating AMPK/PGC-1α/SIRT3 signaling pathway partly to inhibit oxidative stress.
9.Expert consensus on cryoablation therapy of oral mucosal melanoma
Guoxin REN ; Moyi SUN ; Zhangui TANG ; Longjiang LI ; Jian MENG ; Zhijun SUN ; Shaoyan LIU ; Yue HE ; Wei SHANG ; Gang LI ; Jie ZHNAG ; Heming WU ; Yi LI ; Shaohui HUANG ; Shizhou ZHANG ; Zhongcheng GONG ; Jun WANG ; Anxun WANG ; Zhiyong LI ; Zhiquan HUNAG ; Tong SU ; Jichen LI ; Kai YANG ; Weizhong LI ; Weihong XIE ; Qing XI ; Ke ZHAO ; Yunze XUAN ; Li HUANG ; Chuanzheng SUN ; Bing HAN ; Yanping CHEN ; Wenge CHEN ; Yunteng WU ; Dongliang WEI ; Wei GUO
Journal of Practical Stomatology 2024;40(2):149-155
Cryoablation therapy with explicit anti-tumor mechanisms and histopathological manifestations has a long history.A large number of clinical practice has shown that cryoablation therapy is safe and effective,making it an ideal tumor treatment method in theory.Previously,its efficacy and clinical application were constrained by the limitations of refrigerants and refrigeration equipment.With the development of the new generation of cryoablation equipment represented by argon helium knives,significant progress has been made in refrigeration efficien-cy,ablation range,and precise temperature measurement,greatly promoting the progression of tumor cryoablation technology.This consensus systematically summarizes the mechanism of cryoablation technology,indications for oral mucosal melanoma(OMM)cryotherapy,clinical treatment process,adverse reactions and management,cryotherapy combination therapy,etc.,aiming to provide reference for carrying out the standardized cryoablation therapy of OMM.
10.Relationship between lumbar spine development and hip development in children with spastic cerebral palsy
Xinwei ZUO ; Gang LIU ; Huizhong BAI ; Lin XU ; Yi ZHAO ; Jingpei REN ; Chuanyu HU ; Xiaohong MU
Chinese Journal of Tissue Engineering Research 2024;28(8):1247-1252
BACKGROUND:Most scholars now believe that children with cerebral palsy who have severe spinal deformities in early childhood(<15 years of age)may have a higher risk of progression of spinal deformities,which may result from imbalances in movement due to pelvic tilt,pain,etc. OBJECTIVE:To investigate the relationship between lumbar spine development and hip joint development in children with spastic cerebral palsy. METHODS:A retrospective analysis was performed in 102 children with spastic cerebral palsy admitted at Dongzhimen Hospital Affiliated to Beijing University of Chinese Medicine from January 2014 to December 2021.All admitted children had X-rays of the pelvic position and the lumbar lateral position.Anteroposterior X-ray of the pelvis was performed to measure femoral head migration percentage,central edge angle,neck-shaft angle,and acetabular index.The sagittal Cobb angle,sacral slope,arch-top distance,and lumbar lordosis index were measured by the lateral X-ray of the lumbar spine.Correlation of the two sets of indicators was further analyzed.All children were divided into normal group,risk group,hip subluxation group and total hip dislocation group according to their femoral head migration percentage,and the differences in lumbar spine indexes between groups were evaluated. RESULTS AND CONCLUSION:Pearson correlation analysis showed that the femoral head migration percentage was moderately positively correlated with sagittal Cobb angle and arch-top distance,and weakly positively correlated with lumbar lordosis index;the central edge angle was moderately negatively correlated with the arch-top distance and weakly negatively correlated with the sagittal Cobb angle;the neck-shaft angle was weakly positively correlated or not correlated with the sagittal Cobb angle and lumbar lordosis index;and the acetabular index was weakly positively correlated with the sagittal Cobb angle and arch-top distance.No statistically significant correlation was found between the remaining indicators.According to the femoral head migration percentage,the children were divided into four groups,including 25 cases in the normal group,41 cases in the risk group,27 cases in the hip subluxation group,and 9 cases in the total hip dislocation group.The sagittal Cobb angle was significantly increased in the risk group,the hip subluxation group and the total hip dislocation group compared with the normal group,showing an increasing trend group by group,and there were significant differences between groups(P<0.05).Compared with the normal group,the lumbar lordosis index in the risk group and the hip subluxation group increased significantly,and there were significant differences between groups(P<0.05).There was an increase trend in the lumbar lordosis index of the total hip dislocation group compared with the normal group.Compared with the normal group,the arch-top distance in the hip subluxation group and the total hip dislocation group increased significantly(P<0.05),and there was a stepwise increasing trend.There was no significant difference in sacral slope between groups.To conclude,the development of the lumbar spine in children with cerebral palsy is closely related to the development of the pelvic hip joint,and the most obvious relationship is between lumbar lordosis and hip dislocation.

Result Analysis
Print
Save
E-mail