1.Clinical observation of ivabradine in the treatment of chronic heart failure in end-stage renal disease patients undergoing maintenance hemodialysis
Gang TAN ; Yongfang LI ; Guangpeng ZHOU
China Pharmacy 2025;36(1):91-95
OBJECTIVE To investigate the efficacy and safety of ivabradine in the treatment of end-stage renal disease patients with chronic heart failure (CHF) during maintenance hemodialysis (MHD). METHODS End-stage renal disease patients with CHF during MHD who were treated in our hospital from May 2021 to September 2023 and met the inclusion criteria were selected as the study subjects. They were randomly divided into control group and observation group, with 60 cases in each group, using a random number table method. Both groups of patients received MHD three times a week for 4 hours each time and were anticoagulated with low-molecular weight heparin sodium. At the same time, they were treated with CHF conventional therapy; based on the above treatment, observation group was orally administered Ivabradine tablets 5 mg, twice a day (if the resting heart rate was above 60 beats/min after 2 weeks, the drug dose was increased to 7.5 mg, twice a day). Both groups of patients were treated continuously for 6 months. The clinical efficacy of 2 groups was compared as well as vital signs, cardiac function, the levels of heart failure- related biomarkers and inflammatory factors before and after treatment, and the incidences of dialysis-related hypotension and adverse drug reactions. RESULTS The effective rate of the observation group (92.45%) was significantly higher than that of the control group (76.47%), and the incidence of dialysis-related hypotension (20.75%) was significantly lower than that of the control group (41.18%) (P<0.05). The heart rate, the levels of left ventricular end-systolic diameter, left ventricular end-diastolic diameter, serum N-terminal pro-B-type natriuretic peptide, cancer antigen 125, tumor necrosis factor-α, interleukin-6, and hypersensitive C-reactive protein in observation group after treatment were significantly lower than those of control group (P<0.05); the left ventricular ejection fraction and cardiac output were significantly higher than those in the control group (P<0.05). There was no statistically significant difference in the diastolic blood pressure, systolic blood pressure, or the total incidence of adverse drug reactions between the two groups after treatment (P>0.05). CONCLUSIONS Ivabradine can significantly improve cardiac function, inhibit ventricular remodeling, down-regulate serum levels of serum N-terminal pro-B-type natriuretic peptide and cancer antigen 125, decrease body inflammation levels and the incidence of dialysis-related hypotension in end-stage renal disease patients with CHF during MHD, with significant clinical effects and good safety.
2.Improving the Certainty of Evidence in Animal Experiment Systematic Review/Meta-Analysis: An Empirical Study of the GRADE Method
Tengfei LI ; Qingyong ZHENG ; Jianguo XU ; Yiyi LI ; Yongjia ZHOU ; Caihua XU ; Mingyue ZHANG ; Jiexiang TIAN ; Gang WANG ; Jinhui TIAN
Laboratory Animal and Comparative Medicine 2025;45(1):101-111
Animal experiments are essential tools in biomedical research, serving as a bridge between basic research and clinical trials. Systematic reviews and meta-analyses (SRs/MAs) of animal experiments are crucial methods for integrating evidence from animal experiment, which can facilitate the translation of findings into clinical research, reduce translational risks, and promote resource integration in basic research. With the continuous development of the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) methodology, its application in SRs/MAs of animal experiments has gained increasing attention. This article first outlines the principles and specific applications of the GRADE methodology in SRs/MAs of animal experiments, including qualitative descriptive systematic reviews, meta-analyses, and network meta-analyses. It then deeply analyzes the misuse of the GRADE methodology in practice, including incorrect evidence grading, improper classification of evidence, misapplication in qualitative systematic reviews, inconsistencies between the documentation of the upgrading and downgrading process and results, and inappropriate use for making recommendations. Furthermore, this article comprehensively discusses the factors influencing the grading of evidence certainty in SRs/MAs of animal experiments, including the impact of bias risk, indirectness, inconsistency, imprecision, and publication bias on evidence downgrading, as well as the role of large effect sizes and cross-species consistency in evidence upgrading. Finally, in response to the issues discussed, improvement strategies are proposed, including further research and optimization of the GRADE methodology for SRs/MAs of animal experiments, the development of reporting guidelines tailored to the characteristics of SRs/MAs in animal experiment research, and enhanced professional training for researchers in the GRADE methodology. This article aims to improve the quality of evidence in SRs/MAs of animal experiments, strengthen their reliability in clinical decision-making, and promote the more efficient translation of findings from animal experiment research into clinical practice.
3.Four new sesquiterpenoids from the roots of Atractylodes macrocephala
Gang-gang ZHOU ; Jia-jia LIU ; Ji-qiong WANG ; Hui LIU ; Zhi-Hua LIAO ; Guo-wei WANG ; Min CHEN ; Fan-cheng MENG
Acta Pharmaceutica Sinica 2025;60(1):179-184
The chemical constituents in dried roots of
4.Effects of Shujin Jiannao Formula (舒筋健脑方) on Neural Repair and PI3K-Akt-mTOR Pathway of Brain Tissue in Cerebral Palsy Model Rats
Ruiqin YU ; Yanjun MO ; Houjun ZHANG ; Gang LIU ; Zhuoluo ZHOU ; Zechen RUAN ; Lin XU ; Xiaohong MU
Journal of Traditional Chinese Medicine 2025;66(10):1038-1045
ObjectiveTo explore the possible mechanisms of Shujin Jiannao Formula (舒筋健脑方) for cerebral palsy. MethodsThirty 7-day-old SD rats were randomly divided into normal group, model group, and Shujin Jiannao Formula group, with 10 rats in each group. The model group and Shujin Jiannao Formula group established a cerebral palsy model by the classic Rice-Vannucci method. After successful modeling, rats in Shujin Jiannao Formula group were given Shujin Jiannao Formula 16 g/(kg·d) by gavage, while the normal group and model group were given normal saline 10 ml/(kg·d) by gavage once a day. After one week of intervention, the rats' body weight was measured, and Zea-Longa scores, the righting reflex test, and the hindlimb suspension test were conducted for assessment; hematoxylin-eosin (HE) staining and Nissl staining were used to observe pathological changes in brain tissue, and the number of Nissl-positive neurons was counted; enzyme-linked immunosorbent assay (ELISA) was employed to measure levels of inflammatory cytokines in the brain tissue, specifically interleukin-1β (IL-1β) and tumor necrosis factor-α (TNF-α); immunofluorescence was used to detect the expression levels of neurofilament protein 200 (NF200) and myelin basic protein (MBP) in brain tissue; Western Blot analysis was conducted to determine the protein levels of phosphoinositide 3-kinase (PI3K), protein kinase B (Akt/PKB/Rac), and mammalian target of rapamycin (mTOR) in brain tissue. ResultsCompared with the normal group, rats in the model group showed significantly higher Zea-Longa scores and lower scores in the hindlimb suspension test (P<0.01); pathological findings revealed loose structure in the cerebral cortex, hippocampal atrophy, and neuronal damage in brain tissue. Levels of IL-1β and TNF-α elevated, and the number of Nissl-stained positive neurons in the cortex and hippocampal CA1 region reduced, and immunofluorescence intensity of NF200 and MBP, as well as protein expression levels of PI3K and mTOR, significantly decreased (P<0.05 or P<0.01). Compared with the model group, rats in Shujin Jiannao Formula group showed decreased Zea-Longa scores and increased hindlimb suspension test scores (P<0.05); pathological damage in brain tissue alleviated, levels of IL-1β and TNF-α reduced, the number of Nissl-stained positive neurons in the cortex and hippocampal CA1 region increased, and the immunofluorescence intensity of NF200 and MBP, as well as the protein levels of PI3K and mTOR, significantly elevated (P<0.05 or P<0.01). There were no statistically significant differences among the groups in body weight, body-turning time, or AKT protein levels in brain tissue (P>0.05). ConclusionShujin Jiannao Formula can improve the neurological function of rats with cerebral palsy, exert neurorestorative effects, and its mechanism of action may be related to the reduction of inflammatory response in brain tissue and the activation of the PI3K/AKT/mTOR signaling pathway.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Clinical comprehensive evaluation framework for direct oral anticoagulants in the prevention of cancer-associated venous thromboembolism
Yue WU ; Bingzheng SHEN ; Fan ZHANG ; Junfen ZENG ; Yanzhuo LIU ; Gang LIU ; Benhong ZHOU
China Pharmacy 2025;36(11):1384-1388
OBJECTIVE To establish a clinical comprehensive evaluation framework for direct oral anticoagulants (DOACs) in the prevention of cancer-associated venous thromboembolism (CAVTE), providing a methodological reference for the rational prevention and treatment of CAVTE as well as for the formulation and adjustment of macro-management strategies for anticoagulant drugs. METHODS Through literature retrieval, evaluation indicators were collected and organized to establish a preliminary indicator pool. The selection of evaluation indicators was carried out through two rounds of Delphi surveys using average score of indicator importance≥3.5 and a coefficient of variation (CV) <0.25 as the screening criteria. Analytic hierarchy process (AHP) was employed to finalize the indicator weights. RESULTS The authority levels (C)r of the two rounds of expert consultations were 0.877 and 0.943, with CV of 0.24 and 0.18, respectively. The Kendall concordance coefficients were 0.331 and 0.535 (P<0.05). After expert validation, six primary indicators and forty-six secondary indicators were finalized for inclusion in the evaluation framework. The primary indicators and their weightings, ranked in descending order, were as follows:“ effectiveness” (38.86%), “safety” (38.86%),“ cost-effectiveness” (10.67%),“ accessibility” (5.51%),“ suitability” (3.48%), and “innovation” (2.64%). The secondary indicators exhibited a weight range from 0.02% to 20.25%, with the top five secondary indicators being:“ incidence of intracranial hemorrhage” (20.25%), “reduction in all-cause mortality” (15.29%), “decrease in the incidence of pulmonary embolism” (8.82%), “reduction in the incidence of deep vein thrombosis” (7.25%), and “drug contraindications” (4.74%). CONCLUSIONS This study has established an authoritative, scientific, and reliable comprehensive clinical evaluation framework for the use of DOACs in the prevention of CAVTE.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail