1.Introduction and enlightenment of the Recommendations and Expert Consensus for Plasm a and Platelet Transfusion Practice in Critically ill Children: from the Transfusion and Anemia Expertise Initiative-Control/Avoidance of Bleeding (TAXI-CAB)
Lu LU ; Jiaohui ZENG ; Hao TANG ; Lan GU ; Junhua ZHANG ; Zhi LIN ; Dan WANG ; Mingyi ZHAO ; Minghua YANG ; Rong HUANG ; Rong GUI
Chinese Journal of Blood Transfusion 2025;38(4):585-594
To guide transfusion practice in critically ill children who often need plasma and platelet transfusions, the Transfusion and Anemia Expertise Initiative-Control/Avoidance of Bleeding (TAXI-CAB) developed Recommendations and Expert Consensus for Plasma and Platelet Transfusion Practice in Critically Ill Children. This guideline addresses 53 recommendations related to plasma and platelet transfusion in critically ill children with 8 kinds of diseases, laboratory testing, selection/treatment of plasma and platelet components, and research priorities. This paper introduces the specific methods and results of the recommendation formation of the guideline.
2.The role of intraplaque neovascularization in recent and future ischemic stroke in patients with mild carotid stenosis
Luni ZHANG ; Rong WU ; Jing CHEN ; Shiyao GU ; Caixia JIA
Ultrasonography 2025;44(1):62-71
Purpose:
There is still insufficient evidence for predicting stroke risk in patients with mild carotid atherosclerotic stenosis. This study aimed to explore the association between carotid intraplaque neovascularization (IPN) in mild stenosis and ischemic stroke, using contrast-enhanced ultrasound (CEUS) imaging.
Methods:
This retrospective observational study included 369 patients from July 2021 to March 2022. These patients were categorized as symptomatic or asymptomatic based on their recent history of ipsilateral ischemic stroke. Initial parameters of carotid plaques, such as IPN grading and contrast enhancement index, were assessed using B-mode ultrasonography and CEUS. The follow-up period lasted 12 months or until a newly-developed ischemic stroke occurred. Logistic regression models and Cox proportional-hazards regression models were employed to explore the associations between ultrasonic parameters and the incidence of recent and future ischemic strokes.
Results:
In patients with mild stenosis, both increasing age and grade 2 carotid IPN were significant predictors of recent primary ischemic stroke. Furthermore, grade 2 carotid IPN independently predicted future ischemic strokes in both symptomatic and asymptomatic patients.
Conclusion
This study demonstrated that carotid IPN as detected by CEUS imaging holds potential as a useful non-invasive biomarker for predicting recent and future ischemic strokes in patients with mild carotid stenosis.
3.The role of intraplaque neovascularization in recent and future ischemic stroke in patients with mild carotid stenosis
Luni ZHANG ; Rong WU ; Jing CHEN ; Shiyao GU ; Caixia JIA
Ultrasonography 2025;44(1):62-71
Purpose:
There is still insufficient evidence for predicting stroke risk in patients with mild carotid atherosclerotic stenosis. This study aimed to explore the association between carotid intraplaque neovascularization (IPN) in mild stenosis and ischemic stroke, using contrast-enhanced ultrasound (CEUS) imaging.
Methods:
This retrospective observational study included 369 patients from July 2021 to March 2022. These patients were categorized as symptomatic or asymptomatic based on their recent history of ipsilateral ischemic stroke. Initial parameters of carotid plaques, such as IPN grading and contrast enhancement index, were assessed using B-mode ultrasonography and CEUS. The follow-up period lasted 12 months or until a newly-developed ischemic stroke occurred. Logistic regression models and Cox proportional-hazards regression models were employed to explore the associations between ultrasonic parameters and the incidence of recent and future ischemic strokes.
Results:
In patients with mild stenosis, both increasing age and grade 2 carotid IPN were significant predictors of recent primary ischemic stroke. Furthermore, grade 2 carotid IPN independently predicted future ischemic strokes in both symptomatic and asymptomatic patients.
Conclusion
This study demonstrated that carotid IPN as detected by CEUS imaging holds potential as a useful non-invasive biomarker for predicting recent and future ischemic strokes in patients with mild carotid stenosis.
4.The role of intraplaque neovascularization in recent and future ischemic stroke in patients with mild carotid stenosis
Luni ZHANG ; Rong WU ; Jing CHEN ; Shiyao GU ; Caixia JIA
Ultrasonography 2025;44(1):62-71
Purpose:
There is still insufficient evidence for predicting stroke risk in patients with mild carotid atherosclerotic stenosis. This study aimed to explore the association between carotid intraplaque neovascularization (IPN) in mild stenosis and ischemic stroke, using contrast-enhanced ultrasound (CEUS) imaging.
Methods:
This retrospective observational study included 369 patients from July 2021 to March 2022. These patients were categorized as symptomatic or asymptomatic based on their recent history of ipsilateral ischemic stroke. Initial parameters of carotid plaques, such as IPN grading and contrast enhancement index, were assessed using B-mode ultrasonography and CEUS. The follow-up period lasted 12 months or until a newly-developed ischemic stroke occurred. Logistic regression models and Cox proportional-hazards regression models were employed to explore the associations between ultrasonic parameters and the incidence of recent and future ischemic strokes.
Results:
In patients with mild stenosis, both increasing age and grade 2 carotid IPN were significant predictors of recent primary ischemic stroke. Furthermore, grade 2 carotid IPN independently predicted future ischemic strokes in both symptomatic and asymptomatic patients.
Conclusion
This study demonstrated that carotid IPN as detected by CEUS imaging holds potential as a useful non-invasive biomarker for predicting recent and future ischemic strokes in patients with mild carotid stenosis.
5.The role of intraplaque neovascularization in recent and future ischemic stroke in patients with mild carotid stenosis
Luni ZHANG ; Rong WU ; Jing CHEN ; Shiyao GU ; Caixia JIA
Ultrasonography 2025;44(1):62-71
Purpose:
There is still insufficient evidence for predicting stroke risk in patients with mild carotid atherosclerotic stenosis. This study aimed to explore the association between carotid intraplaque neovascularization (IPN) in mild stenosis and ischemic stroke, using contrast-enhanced ultrasound (CEUS) imaging.
Methods:
This retrospective observational study included 369 patients from July 2021 to March 2022. These patients were categorized as symptomatic or asymptomatic based on their recent history of ipsilateral ischemic stroke. Initial parameters of carotid plaques, such as IPN grading and contrast enhancement index, were assessed using B-mode ultrasonography and CEUS. The follow-up period lasted 12 months or until a newly-developed ischemic stroke occurred. Logistic regression models and Cox proportional-hazards regression models were employed to explore the associations between ultrasonic parameters and the incidence of recent and future ischemic strokes.
Results:
In patients with mild stenosis, both increasing age and grade 2 carotid IPN were significant predictors of recent primary ischemic stroke. Furthermore, grade 2 carotid IPN independently predicted future ischemic strokes in both symptomatic and asymptomatic patients.
Conclusion
This study demonstrated that carotid IPN as detected by CEUS imaging holds potential as a useful non-invasive biomarker for predicting recent and future ischemic strokes in patients with mild carotid stenosis.
6.The role of intraplaque neovascularization in recent and future ischemic stroke in patients with mild carotid stenosis
Luni ZHANG ; Rong WU ; Jing CHEN ; Shiyao GU ; Caixia JIA
Ultrasonography 2025;44(1):62-71
Purpose:
There is still insufficient evidence for predicting stroke risk in patients with mild carotid atherosclerotic stenosis. This study aimed to explore the association between carotid intraplaque neovascularization (IPN) in mild stenosis and ischemic stroke, using contrast-enhanced ultrasound (CEUS) imaging.
Methods:
This retrospective observational study included 369 patients from July 2021 to March 2022. These patients were categorized as symptomatic or asymptomatic based on their recent history of ipsilateral ischemic stroke. Initial parameters of carotid plaques, such as IPN grading and contrast enhancement index, were assessed using B-mode ultrasonography and CEUS. The follow-up period lasted 12 months or until a newly-developed ischemic stroke occurred. Logistic regression models and Cox proportional-hazards regression models were employed to explore the associations between ultrasonic parameters and the incidence of recent and future ischemic strokes.
Results:
In patients with mild stenosis, both increasing age and grade 2 carotid IPN were significant predictors of recent primary ischemic stroke. Furthermore, grade 2 carotid IPN independently predicted future ischemic strokes in both symptomatic and asymptomatic patients.
Conclusion
This study demonstrated that carotid IPN as detected by CEUS imaging holds potential as a useful non-invasive biomarker for predicting recent and future ischemic strokes in patients with mild carotid stenosis.
7.Research progress in SARS-CoV-2 nucleic acid detection based on microfluidic platforms
Fan YANG ; Lan WANG ; Hong QIU ; Cheng KONG ; Wei-Wei ZHANG ; Chang GU ; Yue-Rong ZHU
Chinese Medical Equipment Journal 2024;45(1):101-107
The detection principle of microfluidic microfluidic technology was introduced.The current research status of microfluidic platform-based SARS-CoV-2 nucleic acid detection technologies were reviewed such as reverse transcription quantitative real-time polymerase chain reaction(RT-qPCR),digital PCR,isothermal amplification and clustered regularly interspaced palindromic repeats/CRISPR-associated protein.The deficiencies of microfluidic platform-based SARS-CoV-2 nucleic acid detection were analyzed.It's pointed out microfluidic platform-based SARS-CoV-2 nucleic acid detection had to be optimized and validated clinically in specialty,sensitivity,detection limit,reproducibility,informatization,quality control and reagent cost.[Chinese Medical Equipment Journal,2024,45(1):101-107]
8.Expert consensus on clinical application of 177Lu-prostate specific membrane antigen radio-ligand therapy in prostate cancer
Guobing LIU ; Weihai ZHUO ; Yushen GU ; Zhi YANG ; Yue CHEN ; Wei FAN ; Jianming GUO ; Jian TAN ; Xiaohua ZHU ; Li HUO ; Xiaoli LAN ; Biao LI ; Weibing MIAO ; Shaoli SONG ; Hao XU ; Rong TIAN ; Quanyong LUO ; Feng WANG ; Xuemei WANG ; Aimin YANG ; Dong DAI ; Zhiyong DENG ; Jinhua ZHAO ; Xiaoliang CHEN ; Yan FAN ; Zairong GAO ; Xingmin HAN ; Ningyi JIANG ; Anren KUANG ; Yansong LIN ; Fugeng LIU ; Cen LOU ; Xinhui SU ; Lijun TANG ; Hui WANG ; Xinlu WANG ; Fuzhou YANG ; Hui YANG ; Xinming ZHAO ; Bo YANG ; Xiaodong HUANG ; Jiliang CHEN ; Sijin LI ; Jing WANG ; Yaming LI ; Hongcheng SHI
Chinese Journal of Clinical Medicine 2024;31(5):844-850,封3
177Lu-prostate specific membrane antigen(PSMA)radio-ligand therapy has been approved abroad for advanced prostate cancer and has been in several clinical trials in China.Based on domestic clinical practice and experimental data and referred to international experience and viewpoints,the expert group forms a consensus on the clinical application of 177Lu-PSMA radio-ligand therapy in prostate cancer to guide clinical practice.
9.Ceria nanoparticles:biomedical applications and toxicity
FU XIAOXUAN ; LI PENG ; CHEN XI ; MA YUANYUAN ; WANG RONG ; JI WENXUAN ; GU JIAKUO ; SHENG BOWEN ; WANG YIZHOU ; ZHANG ZHUHONG
Journal of Zhejiang University. Science. B 2024;25(5):361-388
Ceria nanoparticles(CeO2 NPs)have become popular materials in biomedical and industrial fields due to theirpotential applications in anti-oxidation,cancer therapy,photocatalytic degradation of pollutants,sensors,etc.Many methods,including gas phase,solid phase,liquid phase,and the newly proposed green synthesis method,have been reported for the synthesis of CeO2 NPs.Due to the wide application of CeO2 NPs,concerns about their adverse impacts on human health have been raised.This review covers recent studies on the biomedical applications of CeO2 NPs,including their use in the treatment of various diseases(e.g.,Alzheimer's disease,ischemic stroke,retinal damage,chronic inflammation,and cancer).CeO2 NP toxicity is discussed in terms of the different systems of the human body(e.g.,cytotoxicity,genotoxicity,respiratory toxicity,neurotoxicity,and hepatotoxicity).This comprehensive review covers both fundamental discoveries and exploratory progress in CeO2 NP research that may lead to practical developments in the future.
10.Measurement and evaluation of personal attenuation rating before and after the training of the noise-exposed workers wearing foam earplugs
Jing LIU ; Xian WANG ; Rong ZHANG ; Youhong BAO ; Kaifeng GU ; Liping PAN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(8):589-593
Objective:To measure and compare the difference of personal attenuation rating (PAR) of the workers wearing foam earplugs before and after the training, and to evaluate the effect of ear protector wearing training on the noise protection.Methods:In February 2023, 94 workers exposed to noise in a machinery manufacturing factory were selected as subjects. The production noise in the workplace was measured and subjects were trained to wear earplugs. The PAR values of wearing 3M 1110 foam test earplugs were measured and recorded before and after the training by using the fit testing of hearing protection device. The differences between the actual PAR values with nominal values and the noise attenuation values in related standards were compared, and the protective effect of hearing protection device before and after training was evaluated.Results:The average age of the subjects was (36.76±11.48) years old, the average length of service was (16.34±11.64) years, and the average exposure time to noise was (15.67±11.64) years. The noise detection results of the subjects' posts were ranged from 80.1 to 94.3 dB (A). The results of subjects wore 3M 1110 foam test earplugs for fit testing showed that the binaural PAR value after training was (19.3±6.4) dB (A), which was significantly higher than that before training (11.1±7.4) dB (A) ( t=13.31, P<0.001). After training, 11 people (11.70%) could reach the corrected noise reduction value (NRR value), 26 people (27.66%) could reach the standard of single noise reduction value (SNR value) ×0.6, and 84 people (89.36%) could reach the standard of (NRR-7) /2. The under protection rate of hearing protectors after training (7.45%) was significantly lower than that before training (45.74%), and the difference of different protection levels before and after training was statistically significant (χ 2=40.83, P<0.001) . Conclusion:It is suggested that enterprises should use the fit testing instead of nominal value estimation to evaluate the noise reduction effect of hearing protection device. Special training on the selection and use of hearing protection device should be strengthened, so as to ensure that workers wear them correctly and improve the protective effect of hearing protection device.

Result Analysis
Print
Save
E-mail