1.O-arm navigation versus C-arm navigation for guiding percutaneous long sacroiliac screws placement in treatment of Denis type Ⅱ sacral fractures.
Wei ZHOU ; Guodong WANG ; Xuan PEI ; Zhixun FANG ; Yu CHEN ; Suyaolatu BAO ; Jianan CHEN ; Ximing LIU
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):28-34
OBJECTIVE:
To compare the effectiveness of O-arm navigation and C-arm navigation for guiding percutaneous long sacroiliac screws in treatment of Denis type Ⅱ sacral fractures.
METHODS:
A retrospective study was conducted on clinical data of the 46 patients with Denis type Ⅱ sacral fractures between April 2021 and October 2022. Among them, 19 patients underwent O-arm navigation assisted percutaneous long sacroiliac screw fixation (O-arm navigation group), and 27 patients underwent C-arm navigation assisted percutaneous long sacroiliac screw fixation (C-arm navigation group). There was no significant difference in gender, age, causes of injuries, Tile classification of pelvic fractures, combined injury, the interval from injury to operation between the two groups ( P>0.05). The intraoperative preparation time, the placement time of each screw, the fluoroscopy time of each screw during placement, screw position accuracy, the quality of fracture reduction, and fracture healing time were recorded and compared, postoperative complications were observed. Pelvic function was evaluated by Majeed score at last follow-up.
RESULTS:
All operations were completed successfully, and all incisions healed by first intention. Compared to the C-arm navigation group, the O-arm navigation group had shorter intraoperative preparation time, placement time of each screw, and fluoroscopy time, with significant differences ( P<0.05). There was no significant difference in screw position accuracy and the quality of fracture reduction ( P>0.05). There was no nerve or vascular injury during screw placed in the two groups. All patients in both groups were followed up, with the follow-up time of 6-21 months (mean, 12.0 months). Imaging re-examination showed that both groups achieved bony healing, and there was no significant difference in fracture healing time between the two groups ( P>0.05). During follow-up, there was no postoperative complications, such as screw loosening and breaking or loss of fracture reduction. At last follow-up, there was no significant difference in pelvic function between the two groups ( P>0.05).
CONCLUSION
Compared with the C-arm navigation, the O-arm navigation assisted percutaneous long sacroiliac screws for the treatment of Denis typeⅡsacral fractures can significantly shorten the intraoperative preparation time, screw placement time, and fluoroscopy time, improve the accuracy of screw placement, and obtain clearer navigation images.
Humans
;
Fracture Fixation, Internal/methods*
;
Retrospective Studies
;
Imaging, Three-Dimensional
;
Bone Screws
;
Surgery, Computer-Assisted
;
Tomography, X-Ray Computed
;
Spinal Fractures/surgery*
;
Fractures, Bone/surgery*
;
Pelvic Bones/injuries*
;
Postoperative Complications
;
Neck Injuries
2.Single Kocher-Langenbeck approach combined with anterograde channel screw technique in treatment of acetabular transverse and posterior wall fractures.
Xuepeng XU ; Jinhui LIU ; Lincong FEI ; Junwu YE
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):35-39
OBJECTIVE:
To assess the effectiveness of the single Kocher-Langenbeck approach combined with anterograde channel screw technique for the treatment of acetabular transverse and posterior wall fractures.
METHODS:
Between March 2020 and October 2022, 17 cases of acetabular transverse and posterior wall fractures were treated with the single Kocher-Langenbeck approach combined with anterograde channel screw technique. There were 11 males and 6 females, with an average age of 53.6 years (range, 42-64 years). Causes of injury included traffic accident in 12 cases, and falling from height in 5 cases. The time from injury to operation ranged from 4 to 16 days with an average of 8.8 days. The operation time, intraoperative blood loss, and fluoroscopy frequency were recorded; X-ray films were reviewed regularly after operation to observe the fracture healing, and postoperative complications were recorded. At last follow-up, Matta score was used to evaluate the reduction of fracture, Harris score and modified Merle D'Aubigné-Postel scores system were used to evaluate the hip joint function.
RESULTS:
The operation time was 150-230 minutes (mean, 185.9 minutes), the intraoperative blood loss was 385-520 mL (mean, 446.2 mL), and the fluoroscopy frequency was 18-34 times (mean, 27.5 times). Postoperative fat liquefaction occurred in 1 case and the other incisions healed by first intention; 3 cases had limb numbness after operation, and the symptoms disappeared after active symptomatic treatment; no urogenital system and intestinal injury occurred. All patients were followed up 12-28 months (mean, 19.9 months). Bone union was achieved in all cases with an average healing time of 10.8 weeks (range, 8-14 weeks). There was no complication such as loosening and breakage of internal fixators. At last follow-up, according to Matta score, 12 cases achieved anatomic reduction, 3 satisfactory reduction, and 2 fair reduction, the satisfactory rate was 88.2%; according to Harris hip function score, 12 cases were excellent, 3 good, and 2 fair, the excellent and good rate was 88.2%; according to the modified Merle D'Aubign Aubigné-Postel scoring system, the results were excellent in 11 cases, good in 3 cases, and fair in 3 cases, with an excellent and good rate of 82.4%.
CONCLUSION
The single Kocher-Langenbeck approach combined with anterograde channel screw technique is a minimally invasive method for the treatment of acetabular transverse and posterior wall fractures with less complications, simple operation, and satisfactory effectiveness.
Male
;
Female
;
Humans
;
Middle Aged
;
Blood Loss, Surgical
;
Fracture Fixation, Internal/methods*
;
Treatment Outcome
;
Fractures, Bone/surgery*
;
Acetabulum/injuries*
;
Bone Screws
;
Hip Fractures/surgery*
;
Retrospective Studies
3.Research progress on valgus impacted proximal humeral fractures.
Bo LI ; Shimin CHANG ; Sunjun HU ; Shouchao DU ; Wenfeng XIONG
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):107-112
OBJECTIVE:
To review the advancement made in the understanding of valgus impacted proximal humeral fracture (PHF).
METHODS:
The domestic and foreign literature about the valgus impacted PHF was extensively reviewed and the definition, classification, pathological features, and treatment of valgus impacted PHFs were summarized.
RESULTS:
PHF with a neck shaft angle ≥160° is recognized as a valgus impacted PHF characterized by the preservation of the medial epiphyseal region of the humeral head, which contributes to maintenance of the medial periosteum's integrity after fracture and reduces the occurrence of avascular necrosis. Therefore, the valgus impacted PHF has a better prognosis when compared to other complex PHFs. The Neer classification designates it as a three- or four-part fracture, while the AO/Association for the Study of Internal Fixation (AO/ASIF) categorizes it as type C (C1.1). In the management of the valgus impacted PHF, the selection between conservative and surgical approaches is contingent upon the patient's age and the extent of fracture displacement. While conservative treatment offers the advantage of being non-invasive, it is accompanied by limitations such as the inability to achieve anatomical reduction and the potential for multiple complications. Surgical treatment includes open reduction combined with steel wire or locking plate and/or non-absorbable suture, transosseous suture technology, and shoulder replacement. Surgeons must adopt personalized treatment strategies for each patient with a valgus impacted PHF. Minimally invasive surgery helps to preserve blood supply to the humeral head, mitigate the likelihood of avascular necrosis, and reduce postoperative complications of bone and soft tissue. For elderly patients with severe comminuted and displaced fractures, osteoporosis, and unsuitable internal fixation, shoulder joint replacement is the best treatment option.
CONCLUSION
Currently, there has been some advancement in the classification, vascular supply, and management of valgus impacted PHF. Nevertheless, further research is imperative to assess the clinical safety, biomechanical stability, and indication of minimally invasive technology.
Aged
;
Humans
;
Bone Plates
;
Bone Wires
;
Fracture Fixation, Internal/adverse effects*
;
Fractures, Comminuted/surgery*
;
Humeral Fractures
;
Osteonecrosis
;
Retrospective Studies
;
Shoulder Fractures/surgery*
;
Treatment Outcome
4.Research progress on biomechanics for internal fixation in tibial plateau fracture.
Jialun LIU ; Yingze ZHANG ; Zhanle ZHENG
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):113-118
OBJECTIVE:
To review the biomechanical research progress of internal fixation of tibial plateau fracture in recent years and provide a reference for the selection of internal fixation in clinic.
METHODS:
The literature related to the biomechanical research of internal fixation of tibial plateau fracture at home and abroad was extensively reviewed, and the biomechanical characteristics of the internal fixation mode and position as well as the biomechanical characteristics of different internal fixators, such as screws, plates, and intramedullary nails were summarized and analyzed.
RESULTS:
Tibial plateau fracture is one of the common types of knee fractures. The conventional surgical treatment for tibial plateau fracture is open or closed reduction and internal fixation, which requires anatomical reduction and strong fixation. Anatomical reduction can restore the normal shape of the knee joint; strong fixation provides good biomechanical stability, so that the patient can have early functional exercise, restore knee mobility as early as possible, and avoid knee stiffness. Different internal fixators have their own biomechanical strengths and characteristics. The screw fixation has the advantage of being minimally invasive, but the fixation strength is limited, and it is mostly applied to Schatzker typeⅠfracture. For Schatzker Ⅰ-Ⅳ fracture, unilateral plate fixation can be used; for Schatzker Ⅴand Ⅵ fracture, bilateral plates fixation can be used to provide stronger fixation strength and avoid the stress concentration. The intramedullary nails fixation has the advantages of less trauma and less influence on the blood flow of the fracture end, but the fixation strength of the medial and lateral plateau is limited; so it is more suitable for tibial plateau fracture that involves only the metaphysis. Choosing the most appropriate internal fixation according to the patient's condition is still a major difficulty in the surgical treatment of tibial plateau fractures.
CONCLUSION
Each internal fixator has good fixation effect on tibial plateau fracture within the applicable range, and it is an important research direction to improve and innovate the existing internal fixator from various aspects, such as manufacturing process, material, and morphology.
Humans
;
Biomechanical Phenomena
;
Bone Plates
;
Fracture Fixation, Internal
;
Fracture Fixation, Intramedullary
;
Tibial Fractures/surgery*
;
Tibial Plateau Fractures
8.Comparative study on effectiveness of ultrasound- and arthrography-assisted Kirschner wire fixation in treatment of Jakob type Ⅱ lateral condylar humerus fractures in children.
Xiwei SUN ; Hailong MA ; Fang LIU ; Zhiye GUAN ; Sicheng ZHANG ; Jun SUN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(8):952-957
OBJECTIVE:
To compare the effectiveness of ultrasound- and arthrography-assisted Kirschner wire fixation in the treatment of Jakob type Ⅱ lateral condylar humerus fracture (LCHF) in children.
METHODS:
A clinical data of 101 children with Jakob type Ⅱ LCHF, who met the selection criteria and were admitted between April 2021 and April 2022, was retrospectively analyzed. Of them, 47 cases were treated with ultrasound-assisted Kirschner wire fixation (group A), and 54 cases with arthrography-assisted surgery (group B). There was no significant difference in gender, age, cause of injury, fracture side, and disease duration between groups (P>0.05). Intraoperative fluoroscopy times, operation time, and hospital stay, Flynn elbow joint function score, and postoperative complications were recorded and compared between groups. X-ray examination was performed to observe the healing of fracture, and measure the carrying angle and the shaft-condylar angle (SCA).
RESULTS:
The success rate of closed reduction was significantly higher in group A than in group B (P<0.05), and the intraoperative fluoroscopy times was significantly less in group A than in group B (P<0.05). There was no significant difference in operation time and hospital stay between groups (P>0.05). All children in both groups were followed up 12-18 months, with an average of 13.6 months. X-ray reexamination showed that the fractures of both groups healed, and the difference in healing time was not significant (P>0.05). At last follow-up, there was no significant difference in carrying angle and SCA between unaffected side and affected side in both groups and between groups A and B in affected side (P>0.05). There was no significant difference in Flynn elbow joint function score between groups (P>0.05). There were 18 cases of lateral spurs formation in group A, 1 case of pinning infection and 26 cases of lateral spurs formation in group B, and there was no significant difference in the incidence of the above complications (P>0.05).
CONCLUSION
Compared with the arthrography, the ultrasound-assisted Kirschner wire fixation in the treatment of Jakob type Ⅱ LCHF in children can avoid the open reduction and decrease the number of intraoperative fluoroscopy, and obtain the good effectiveness.
Child
;
Humans
;
Arthrography
;
Bone Wires
;
Humeral Fractures/surgery*
;
Humerus
;
Retrospective Studies
;
Male
;
Female
9.Effectiveness of TiRobot-assisted and free-hand percutaneous kyphoplasty via pedicle of vertebra in treatment of osteoporotic vertebral compression fracture of thoracic vertebra.
Mingzhi MA ; Zhicong WANG ; Jiahui YE ; Xi CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(9):1106-1112
OBJECTIVE:
To compare the effectiveness of TiRobot-assisted and C-arm X-ray fluoroscopy assisted percutaneous kyphoplasty (PKP) via pedicle of vertebra in the treatment of osteoporotic vertebral compression fracture (OVCF) of thoracic vertebrae.
METHODS:
The clinical data of 85 patients with OVCF of thoracic vertebrae who were admitted between January 2020 and March 2023 and met the selection criteria was retrospectively analyzed including 40 patients (50 vertebrae) undergoing PKP assisted by TiRobot (group A) and 45 patients (50 vertebrae) undergoing PKP assisted by C-arm X-ray fluoroscopy (group B). There was no significant difference in the comparison of baseline data such as gender, age, body mass index, bone mineral density T-value, fracture segment, trauma history, and preoperative numerical rating scale (NRS) score, Oswestry disability index (ODI), and Cobb angle of injured vertebra between the two groups ( P>0.05). The effectiveness evaluation indexes of the two groups, including the operation time, the volume of injected cement, the times of fluoroscopies, the length of hospital stay, and the occurrence of postoperative complications were collected and compared. Anteroposterior and lateral X-ray films and CT of the injured vertebra were reviewed at 1 day after operation to observe whether there was cement leakage and to evaluate the distribution of cement in the injured vertebra. Before and after operation, pain was assessed using the NRS score, dysfunction was assessed using the ODI, and vertebral height recovery was assessed by measuring the Cobb angle of the injured vertebrae by X-ray films.
RESULTS:
Both groups of patients successfully completed the operation, the operation time, the volume of injected cement, the times of fluoroscopies, and the length of hospital stay in group A were significantly less than those in group B ( P<0.05). The patients in two groups were followed up 4-12 months (mean, 9.6 months). Bone cement leakage occurred in 5 vertebrae in group A and 15 vertebrae in group B after operation, all of which leaked to the intervertebral space and around the vertebral body, and the patients had no obvious clinical symptoms. The difference of bone cement leakage between the two groups was significant ( P<0.05). No severe complication such as intraspinal leakage, infection, or vascular embolism was found in the two groups. At 1 day after operation, the distribution index of bone cement in group A was mostly grade Ⅴ, which was well dispersed; while in group B, it was mostly grade Ⅱ and grade Ⅴ; the difference of bone cement distribution index between the two groups was significant ( P<0.05). The NRS score, ODI, and Cobb angle of injured vertebra in both groups were significantly improved at 1 day after operation when compared with preoperative ones ( P<0.05). There was no significant difference in the difference of the above indexes between the two groups before and after operation ( P>0.05).
CONCLUSION
TiRobot-assisted unilateral PKP in the treatment of OVCF of thoracic vertebrae is safe and effective, which can reduce the X-ray transmission times during operation, shorten the operation time, reduce the volume of bone cement injection, and thus decrease incidence of bone cement leakage.
Humans
;
Thoracic Vertebrae/surgery*
;
Fractures, Compression/surgery*
;
Spinal Fractures/surgery*
;
Kyphoplasty
;
Bone Cements
;
Retrospective Studies
10.Three-dimensional-printed hemi-pelvic prosthesis for revision of aseptic loosening or screw fracture of modular hemi-pelvic prosthesis.
Xin LIU ; Yi LUO ; Xuanhong HE ; Jie WANG ; Zhuangzhuang LI ; Yuqi ZHANG ; Xin HU ; Minxun LU ; Fan TANG ; Yong ZHOU ; Li MIN ; Chongqi TU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1183-1189
OBJECTIVE:
To investigate the effectiveness of three-dimensional (3D)-printed hemi-pelvic prosthesis for revision of aseptic loosening or screw fracture of modular hemi-pelvic prosthesis.
METHODS:
Between February 2017 and January 2020, 11 patients with aseptic loosening or screw fracture of modular hemi-pelvic prosthesis were revised using 3D-printed hemi-pelvic prostheses. There were 7 males and 4 females with an average age of 44 years (range, 25-60 years). In the first operation, all patients underwent total tumor resection, modular hemi-pelvic prosthesis reconstruction, and autologous femoral head transplantation. According to the Enneking pelvic partition system, 8 cases were resected in zones Ⅰ+Ⅱ and 3 cases in zones Ⅰ+Ⅱ+Ⅲ. The interval from the initial operation to this revision ranged from 14.3-66.2 months, with an average of 35.8 months. The operation time, the amount of intraoperative bleeding, and the occurrence of complications were recorded. At 6 months after the first operation, before revision, and at last follow-up, the American Musculoskeletal Tumor Society (MSTS) score and Harris score were used to evaluate the recovery of lower limb function. The pain-free walking distance of patients without brace assistance was recorded at last follow-up. X-ray films were taken at 1 month after the first operation, before revision, and at 1 month after revision, the acetabulum position was assessed by the differences in weight arm and cup height between bilateral hip joints. At last follow-up, the digital X-ray tomography was taken to evaluate the prosthesis-bone integration and the occurrence of aseptic loosening.
RESULTS:
The operation time was 182.6-238.0 minutes (mean, 197.4 minutes). The amount of intraoperative bleeding was 400-860 mL (mean, 550.0 mL). All incisions healed by first intention with no infection, hip dislocation, nerve damage, or vascular-related adverse events. The MSTS score and Harris score at last follow-up were significantly higher than those at 6 months after the first operation and before revision ( P<0.05), while the score before revision was significantly lower than that at 6 months after the first operation ( P<0.05). At last follow-up, the patients were able to walk more than 1 000 meters painlessly without brace assistance. Imaging review showed that the difference of cup height at 1 month after revision was significantly lower than that at 1 month after the first operation and before revision, and at 1 month after the first operation than before revision operation, and the differences were significant ( P<0.05). There was no significant difference in the difference of weight arm among three time points ( P>0.05). All prostheses were well integrated, and no aseptic loosening of the prosthesis or screw fracture occurred.
CONCLUSION
Revision with 3D-printed hemi-pelvic prostheses benefited in reconstructing stable pelvic ring and natural bodyweight transmission for patients encountering the aseptic loosening or screw fracture of modular hemi-pelvic prosthesis. Early postoperative rehabilitation training can maximize the recovery of patient limb function, reduce pain during walking, and reduce the incidence of complications.
Male
;
Female
;
Humans
;
Adult
;
Arthroplasty, Replacement, Hip/methods*
;
Hip Prosthesis
;
Treatment Outcome
;
Prosthesis Failure
;
Fractures, Bone/surgery*
;
Retrospective Studies
;
Neoplasms

Result Analysis
Print
Save
E-mail