1.Clinical application of percutaneous pedicle screw placement guided by ultrasound volume navigation combined with X-ray fluoroscopy: a prospective randomized controlled study.
Xuxin LIN ; Lijie SHANG ; Suhong SHEN ; Qingfeng WANG ; Xiaoyan FU ; Gang ZHAO
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1253-1258
OBJECTIVE:
To explore the feasibility and accuracy of ultrasound volume navigation (UVN) combined with X-ray fluoroscopy-guided percutaneous pedicle screw implantation through a prospective randomized controlled study.
METHODS:
Patients with thoracic and lumbar vertebral fractures scheduled for percutaneous pedicle screw fixation between January 2022 and January 2023 were enrolled. Among them, 60 patients met the selection criteria and were included in the study. There were 28 males and 32 females, with an average age of 49.5 years (range, 29-60 years). The cause of injury included 20 cases of traffic accidents, 21 cases of falls, 17 cases of slips, and 2 cases of heavy object impact. The interval from injury to hospital admission ranged from 1 to 5 days (mean, 1.57 days). The fracture located at T 12 in 15 cases, L 1 in 20 cases, L 2 in 19 cases, and L 3 in 6 cases. The study used each patient as their own control, randomly guiding pedicle screw implantation using UVN combined with X-ray fluoroscopy on one side of the vertebral body and the adjacent segment (trial group), while the other side was implanted under X-ray fluoroscopy (control group). A total of 4 screws and 2 rods were implanted in each patient. The implantation time and fluoroscopy frequency during implantation of each screw, angle deviation and distance deviation between actual and preoperative planned trajectory by imaging examination, and the occurrence of zygapophysial joint invasion were recorded.
RESULTS:
In terms of screw implantation time, fluoroscopy frequency, angle deviation, distance deviation, and incidence of zygapophysial joint invasion, the trial group showed superior results compared to the control group, and the differences were significant ( P<0.05).
CONCLUSION
UVN combined with X-ray fluoroscopy-guided percutaneous pedicle screw implantation can yreduce screw implantation time, adjust dynamically, reduce operational difficulty, and reduce radiation damage.
Male
;
Female
;
Humans
;
Middle Aged
;
Pedicle Screws
;
Prospective Studies
;
X-Rays
;
Surgery, Computer-Assisted/methods*
;
Spinal Fusion/methods*
;
Fluoroscopy/methods*
;
Lumbar Vertebrae/injuries*
2.Clinical application of special fluoroscopy method in the treatment of distal radius fractures with volar locking plate.
Rong ZHANG ; He-Ming NIU ; Tao GUO ; Ping-Feng XIE ; Jia-Ming WU ; Jia-Bing XIE ; Lin WANG
China Journal of Orthopaedics and Traumatology 2023;36(2):128-132
OBJECTIVE:
The relationship between the distal screws and the wrist articular surface was assessed by the additional lateral oblique fluoroscopic view during the operation, and the dorsal tangential view of the wrist was used to observe whether the distal screw penetrated the dorsal cortex, so as to evaluate the clinical efficacy of the volar locking plate in the treatment of distal radius fractures.
METHODS:
From January 2020 to June 2021, 45 cases of fresh distal radius fractures were treated using the volar Henry's approach, including 20 males and 25 females, aged from 32 to 75 years old with an average of (52.4±8.1) years old. During the operation, they were divided into 2 groups according to the different intraoperative fluoroscopic views:the control group of 20 cases, treated with standard anteroposterior and lateral fluoroscopic view;25 cases in the observation group, additional lateral oblique fluoroscopic view and dorsal tangential view of the wrist were taken. The wrist joint function score and postoperative complications were evaluated at 6 weeks, 3 and 6 months after operation between two groups.
RESULTS:
All 45 patients were followed up and the duration ranged from 6 to 14 months, with an average of (10.8±1.7) months, all patients achieved bone union and the incision healed well. The incidence of postoperative complications in the observation group was lower than that in the control group, and the difference was statistically significant (P<0.05). In terms of Gartland-Werley score of wrist joint function, the score of wrist function in the observation group was (4.58±1.31) at 6 weeks, (2.98±0.63) at 3 months and (1.95±0.65) at 6 months post-operatively, which were better than those in the control group (6.32±1.96) at 6 weeks, (3.63±0.76) at 3 months and (2.43±0.73) at 6 months. The difference was statistically significant (P<0.05). In the observation group, 7/25 cases(28%) were found to have screw penetration during the operation by additional lateral oblique and dorsal tangential radiograph fluoroscopic views of wrist.
CONCLUSION
The addition of lateral oblique and dorsal tangential during the operation could improve the accuracy of distal screw placement, reduce postoperative complications, and achieve early functional exercise.
Male
;
Female
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Wrist Fractures
;
Radius Fractures/surgery*
;
Fracture Fixation, Internal/methods*
;
Fluoroscopy/methods*
;
Bone Plates
;
Postoperative Complications
3.Initial clinical experience of left bundle branch pacing after transcatheter aortic valve implantation.
Tian Jie FENG ; Guang Yuan SONG ; Jie ZHAO ; Yang CHEN ; Guan Nan NIU ; Zheng ZHOU ; Zhen Yan ZHAO ; Mo Yang WANG ; Yong Gang SUI ; Ke Ping CHEN ; Wei HUA ; Yong Jian WU
Chinese Journal of Cardiology 2022;50(2):142-149
Objective: To investigate the efficacy and safety of left bundle branch pacing(LBBP) in patients after transcatheter aortic valve implantation (TAVI). Methods: This is a retrospective study. A total of 35 patients underwent TAVI and received pacemaker implantation from January 2018 to December 2020 in Beijing Fuwai Hospital were enrolled. Patients were divided into LBBP group (n=12) and right ventricular apex pacing (RVAP) group (n=23) according to the pacing position. The success rate of operation in LBBP group was calculated, and the occurrence of complications were observed, and the parameters of pacemaker were measured on the 3rd day and 1, 3 and 6 months after operation. The N-terminal pro-B-type natriuretic peptide (NT-proBNP), echocardiographic and ECG indexes were compared between the two groups on the 3rd day and 1, 3, and 6 months after pacemaker implantation. Result: A total of 35 patients were included, The age was (76.4±7.7) years, including 19 males (54.3%). The procedure time ((86.58±17.10)min vs. (68.74±9.18)min, P<0.001) and fluoroscopy duration ((20.08±4.44)min vs. (17.00±2.26)min, P<0.001) were significantly longer in LBBP group compared with RVAP group. The operation success rate of LBBP group was 11/12. There was no serious operation related complications such as pneumothorax, hemothorax, electrode dislocation, infection, and lower limb bleeding. The patients were followed up for 7.43 (5.21, 9.84) months. The programmed parameters of pacemaker were in the ideal range and stable during follow-up. At 3 and 6 months after operation, the left ventricular ejection fraction in LBBP group was higher than that in RVAP Group (at 3 months: (60.75±2.89)% vs. (57.35±3.33)%, P=0.004; at 6 months: (63.17±3.33)% vs. (56.17±3.97)%, P<0.001), NT-proBNP values was lower in LBBP group than that in RVAP Group (at 3 months: 822 (607, 1 150)ng/L vs. 1 052 (902, 1 536)ng/L, P=0.006; at 6 months: 440 (330,679)ng/L vs. 783 (588, 1 023)ng/L, P=0.001). At 1, 3 and 6 months after operation, the QRS duration was shorter in LBBP group than that in RVAP group (1 month: 99 (97, 107)ms vs. 126(124, 130)ms, P<0.001; 3 months: 98(96, 105)ms vs. 129(128, 133)ms, P<0.001; 6 months: 96(94, 104)ms vs. 130(128, 132)ms, P<0.001). Conclusions: For patients with permanent pacemaker indications after TAVI, LBBP is feasible, safe and reliable. It could improve the cardiac function in the short term, the long-term effect of LBBP needs to be further observed.
Aged
;
Aged, 80 and over
;
Bundle of His
;
Cardiac Pacing, Artificial/methods*
;
Electrocardiography/methods*
;
Fluoroscopy
;
Humans
;
Male
;
Retrospective Studies
;
Stroke Volume
;
Transcatheter Aortic Valve Replacement/adverse effects*
;
Treatment Outcome
;
Ventricular Function, Left
4.A case-control study of minimally invasive transforaminal interbody fusion with the assistance of robot and traditional fluoroscopy in the treatment of single-space lumbar disc herniation.
Hao-Jie CHEN ; Xiao-Qiang HUANG ; Lin GAO ; Jia-Nan ZHANG ; Shi-Chang LIU ; Lin-Na CHEN ; Ding-Jun HAO ; Zi-Long ZHANG ; Rui QIAO ; Jia-Rui YANG
China Journal of Orthopaedics and Traumatology 2022;35(2):101-107
OBJECTIVE:
To compare the safety and nail placement accuracy of fluoroscopy-assisted and robot-assisted minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) in the treatment of single-space lumbar disc herniation.
METHODS:
The clinical data of 52 patients with single-space lumbar disc herniation treated by MIS-TLIF from March 2019 to February 2020 were retrospectively analyzed. Among them, 24 patients were treated by robot-assisted MIS-TLIF(group A) and 28 patients were treated by fluoroscopy-assisted MIS-TLIF (group B). The intraoperative blood loss, operation time, intraoperative fluoroscopy times, preoperative and postoperative visual analogue scale(VAS), Japanese Orthopaedic Association(JOA) scores and operation-related complications were recorded in two groups. Gertzbein-Robbins grade according to CT scan was used to evaluate the nail placement after operation. Grade A and B were evaluated as satisfactory nail placement, and grade C, D, and E were evaluated as error placement. Babu's method was used to evaluate the screw's invasion to the superior articular process.
RESULTS:
The operation time, intraoperative blood loss and intraoperative fluoroscopy times in group A were less than those in group B(P<0.05).VAS and JOA scores of all patients at the final follow-up were significantly improved compared with those before operation(P<0.05), but there was no statistically significant difference between the groups(P>0.05). There were 96 and 112 screws in group A and group B, respectively. Three days after operation, according to the Gertzbein-Robbins grade to evaluate the nail placement accuracy, there were 90 screws of grade A, 5 of grade B, 1 of grade C, no grade D and E in group A;there were 84 screws of grade A, 16 of grade B, 8 of grade C, 4 of grade D, no grade E in group B;the difference between two groups was statistically significant(Z=-3.709, P=0.000). The satisfactory rate of screw placement in group A was 98.96% (95/96), and that of group B was 89.29% (100/112), the difference between two groups was statistically significant (χ2=8.254, P=0.004). Three days after operation, the invasion of superior facet joints by pedicle screws was evaluated according to Babu's method, including 90 screws in grade 0, 4 in grade 1, 2 in grade 2, and 0 in grade 3 in group A;86 in grade 0, 12 in grade 1, 10 in grade 2 and 4 in grade 3 in group B, and the difference was statistically significant(Z=-3.433, P=0.001). There were no serious spinal cord, nerve and vascular injuries and other operation-related complications caused by screw implantation failure in both groups. All patients were followed up from 6 to 12(9.06±1.60) months. The neurological symptoms improved well after operation. During the follow-up period, there was no recurrence of symptoms, loosening or breakage of the internal fixation.
CONCLUSION
Compared with the traditional fluoroscopy-assisted MIS-TLIF, the spinal robot-assisted MIS-TLIF not only has more minimally invasive and safer, but also has higher accuracy in nail placement, lower incidence of upper articular process invasion, and more accurate decompression targets, which can be used for minimally invasive treatment of single-space lumbar disc herniation.
Case-Control Studies
;
Fluoroscopy
;
Humans
;
Intervertebral Disc Displacement/surgery*
;
Lumbar Vertebrae/surgery*
;
Minimally Invasive Surgical Procedures/methods*
;
Pedicle Screws
;
Retrospective Studies
;
Robotics
;
Spinal Fusion/methods*
;
Treatment Outcome
5.Accuracy and safety of robot assisted pedicle screw placement.
Tong-Tong ZHANG ; Zeng-Ping WANG ; Zhong-Hua WANG ; Qi-Yuan WANG ; Wen XUE ; Yu-Xin SONG ; Lin LIU
China Journal of Orthopaedics and Traumatology 2022;35(2):108-112
OBJECTIVE:
To investigate the accuracy and safety of pedicle screw placement assisted by orthopedic robot and C-arm fluoroscopy.
METHODS:
The clinical data of 36 patients with spinal diseases underwent surgical treatment from January 2019 to August 2020 was retrospectively analyzed. Among them, 18 cases were implanted pedicle screws assisted by orthopaedic robot(observation group), including 12 males and 6 females, aged from 16 to 61 years with an average of (38.44±3.60) years;there were 1 case of adolescent scoliosis, 1 case of spinal tuberculosis, 7 cases of lumbar spondylolisthesis, 4 cases of thoracic fracture and 5 cases of lumbar fracture. Another 18 cases were implanted pedicle screws assisted by C-arm fluoroscopy(control group), including 10 males and 8 females, aged from 18 to 58 years with an average of (43.22±2.53) years;there were 1 case of adolescent scoliosis, 6 cases of lumbar spondylolisthesis, 6 cases of thoracic fracture and 5 cases of lumbar fracture. The intraoperative fluoroscopy times, nail placement time and postoperative complications were recorded in two groups. CT scan was performed after operation. The Gertzbein-Robbins standard was used to evaluate the accuracy of pedicle screw placement which was calculated.
RESULTS:
The number of intraoperative fluoroscopy in observation group was(6.89±0.20) times, which was significantly higher than that in control group(14.00±0.18)times(P<0.05). The placement time of each screw in observation group was(2.56±0.12) min, which was significantly different from that in control group(4.22±0.17) min (P<0.05). One case of incision infection occurred in control group after operation, and recovered after active dressing change. During the follow-up period, no serious complications such as screw loosening and fracture occurred in two groups, and there was no significant difference in complications between two groups(P>0.05). A total of 107 screws were placed in observation group, including 101 screws in class A, 4 in class B, 2 in class C, 0 in class D and 0 in class E, the accuracy rate of pedicle screw placement=[(number of screws in class A+B) / the number of all screws placed in the group] ×100%=98.1%(105/107); and a total of 104 screws were placed in control group, including 90 screws in class A, 4 in class B, 5 in class C, 5 in class D and 0 in class E, the accuracy rate of pedicle screw implantation=[(number of screws in class A+B/the number of all screws placed in the group]×100%=90.3% (94/104); there was significant difference between two groups (P<0.05).
CONCLUSION
Orthopaedic robot assisted pedicle screw placement has the advantages of less fluoroscopy times, shorter screw placement time and higher accuracy, which can further improve the surgical safety and has a broad application prospect in the orthopaedic.
Adolescent
;
Adult
;
Female
;
Fluoroscopy/methods*
;
Humans
;
Lumbar Vertebrae/surgery*
;
Male
;
Middle Aged
;
Pedicle Screws
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Robotics
;
Scoliosis
;
Spinal Fusion/methods*
;
Surgery, Computer-Assisted
;
Young Adult
6.Foreign Body Removal in Children Using Foley Catheter or Magnet Tube from Gastrointestinal Tract
Jae Young CHOE ; Byung Ho CHOE
Pediatric Gastroenterology, Hepatology & Nutrition 2019;22(2):132-141
Foreign body (FB) ingestion of children is a common pediatric emergency requiring medical attention. Pediatric emergency physicians and gastroenterologists often encounter nervous and distressed situations, because of children presenting with this condition in the common clinical practice. When determining the appropriate timing and indications for intervention, physicians should consider multiple patient- and FB-related factors. The utilization of a flexible endoscopy is considered safe and effective to use in these cases, with a high success rate, for the effective extraction of FBs from the gastrointestinal tract of a child. Additionally, a Foley catheter and a magnet-attached Levin tube have been used for decades in the case of FB removal. Although their use has decreased significantly in recent times, these instruments continue to be used for several indications. Using a Foley catheter for this purpose does not require special training and does not necessarily require sedation of the patient or fluoroscopy, which serve as advantages of utilizing this method for foreign object retrieval. An ingested magnet or iron-containing FB can be retrieved using a magnet-attached tube, and can be effective to retrieve an object from any section of the upper gastrointestinal tract that can be reached. Simple and inexpensive devices such as Foley catheters and magnet-attached tubes can be used in emergencies such as with the esophageal impaction of disk batteries if endoscopy cannot be performed immediately (e.g., in rural areas and/or in patients presenting at midnight in a facility, especially in those without access to endoscopes or emergency services, or in any situation that warrants urgent removal of a foreign object).
Catheters
;
Child
;
Eating
;
Emergencies
;
Endoscopes
;
Endoscopy
;
Esophagus
;
Fluoroscopy
;
Foreign Bodies
;
Gastrointestinal Tract
;
Humans
;
Methods
;
Upper Gastrointestinal Tract
;
Urinary Catheterization
7.Feasibility of Ultrasound-Guided Lumbar and S1 Nerve Root Block: A Cadaver Study
Jaewon KIM ; Hye Jung PARK ; Won Ihl LEE ; Sun Jae WON
Clinical Pain 2019;18(2):59-64
OBJECTIVE: This study evaluated the feasibility of ultrasound-guided lumbar nerve root block (LNRB) and S1 nerve root block by identifying spread patterns via fluoroscopy in cadavers.METHOD: A total of 48 ultrasound-guided injections were performed in 4 fresh cadavers from L1 to S1 roots. The target point of LNRB was the midpoint between the lower border of the transverse process and the facet joint at each level. The target point of S1 nerve root block was the S1 foramen, which can be visualized between the median sacral crest and the posterior superior iliac spine, below the L5-S1 facet joint. The injection was performed via an in-plane approach under real-time axial view ultrasound guidance. Fluoroscopic validation was performed after the injection of 2 cc of contrast agent.RESULTS: The needle placements were correct in all injections. Fluoroscopy confirmed an intra-foraminal contrast spreading pattern following 41 of the 48 injections (85.4%). The other 7 injections (14.6%) yielded typical neurograms, but also resulted in extra-foraminal patterns that occurred evenly in each nerve root, including S1.CONCLUSION: Ultrasound-guided injection may be an option for the delivery of injectate into the S1 nerve root, as well as lumbar nerve root area.
Cadaver
;
Fluoroscopy
;
Injections, Spinal
;
Lumbosacral Region
;
Methods
;
Needles
;
Spinal Nerve Roots
;
Spine
;
Ultrasonography
;
Zygapophyseal Joint
8.Clinical Characteristics of Peripherally Inserted Central Catheter in Critically Ill Patients
Hyoung Joo KIM ; Chang Yeon JUNG ; Jung Min BAE
Journal of Acute Care Surgery 2019;9(1):18-24
PURPOSE: Ensuring the stability of central venous catheter placement for treating patients hospitalized in an intensive care unit is very important. Although PICC requires an ultrasound and fluoroscopy machine, it is difficult to use a fluoroscopy machine for PICC insertion in the intensive care unit. This study analyzed the cases of the insertion of a PICC under ultrasonic guidance at the bedsides in the intensive care unit to determine the usefulness of PICC in the intensive care unit. METHODS: A retrospective study was conducted on patients hospitalized in the surgical intensive care unit and received PICC using ultrasonography at their bedsides from October 2015 to January 2018. RESULTS: One hundred and twenty patients were collected. The number of successful PICCs stood at 105 patients, which was equal to 87.5%. Among them, 65 and 55 cases had left and right insertion, respectively; the corresponding success rate was 81.8%, and 92.3%. No statistically significant difference in success rates was observed between the left and right, as well as in the success rates depending on the presence of shock, sepsis, acute kidney injury, and mechanical ventilation. In the failed 15 cases, seven cases were due to the course of the procedure and eight cases were confirmed have been malpositioned after insertion. CONCLUSION: PICC at the bedside in an intensive care unit is a safe method for central venous catheterization without severe complications and death. The insertion sites, left or right, are equally acceptable. Further study of the cases of malposition will be necessary.
Acute Kidney Injury
;
Catheterization
;
Catheterization, Central Venous
;
Catheters
;
Central Venous Catheters
;
Critical Care
;
Critical Illness
;
Fluoroscopy
;
Humans
;
Intensive Care Units
;
Methods
;
Respiration, Artificial
;
Retrospective Studies
;
Sepsis
;
Shock
;
Ultrasonics
;
Ultrasonography
9.Fluoroscopic Characterization of Colonic Dysmotility Associated to Opioid and Cannabinoid Agonists in Conscious Rats
Susana DÍAZ-RUANO ; Ana E LÓPEZ-PÉREZ ; Rocío GIRÓN ; Irene PÉREZ-GARCÍA ; María I MARTÍN-FONTELLES ; Raquel ABALO
Journal of Neurogastroenterology and Motility 2019;25(2):300-315
BACKGROUND/AIMS: Gastrointestinal adverse effects have a major impact on health and quality of life in analgesics users. Non-invasive methods to study gastrointestinal motility are of high interest. Fluoroscopy has been previously used to study gastrointestinal motility in small experimental animals, but they were generally anesthetized and anesthesia itself may alter motility. In this study, our aim is to determine, in conscious rats, the effect of increasing doses of 2 opioid (morphine and loperamide) and 1 cannabinoid (WIN 55,212-2) agonists on colonic motility using fluoroscopic recordings and spatio-temporal maps. METHODS: Male Wistar rats received barium sulfate intragastrically, 20–22 hours before fluoroscopy, so that stained fecal pellets could be seen at the time of recording. Animals received an intraperitoneal administration of morphine, loperamide, or WIN 55,212-2 (at 0.1, 1, 5, or 10 mg/kg) or their corresponding vehicles (saline, Cremophor, and Tocrisolve, respectively), 30 minutes before fluoroscopy. Rats were conscious and placed within movement-restrainers for the length of fluoroscopic recordings (120 seconds). Spatio-temporal maps were built, and different parameters were analyzed from the fluoroscopic recordings in a blinded fashion to evaluate colonic propulsion of endogenous fecal pellets. RESULTS: The analgesic drugs inhibited propulsion of endogenous fecal pellets in a dose-dependent manner. CONCLUSIONS: Fluoroscopy allows studying colonic propulsion of endogenous fecal pellets in conscious rats. Our method may be applied to the noninvasive study of the effect of different drug treatments and pathologies.
Analgesics
;
Anesthesia
;
Animals
;
Barium Sulfate
;
Cannabinoid Receptor Agonists
;
Cannabinoids
;
Colon
;
Fluoroscopy
;
Gastrointestinal Motility
;
Humans
;
Loperamide
;
Male
;
Methods
;
Morphine
;
Pathology
;
Quality of Life
;
Rats
;
Rats, Wistar
10.Navigated versus Conventional Technique in High Tibial Osteotomy: A Meta-Analysis Focusing on Weight Bearing Effect
Kyung Wook NHA ; Young Soo SHIN ; Hyuk Min KWON ; Jae Ang SIM ; Young Gon NA
The Journal of Korean Knee Society 2019;31(2):81-102
PURPOSE: We aimed to determine whether navigated opening wedge high tibial osteotomy (HTO) is superior to the conventional technique in terms of accuracy of the coronal and sagittal alignment correction, functional outcome, and operative time. METHODS: Studies comparing navigated and conventional HTO were included in this meta-analysis. We compared the incidence of radiological outliers in coronal alignment and tibial slope maintenance, mean differences in functional outcome scales, and operative time. Subgroup analyses were performed on coronal alignment accuracy based on the intraoperative method of alignment confirmation: fluoroscopy vs. gap measurement method. RESULTS: Twelve studies were included: there were 434 knees in the navigated HTO studies and 405 knees in the conventional HTO studies. The risk of outlier was lower in navigated HTO than in conventional HTO; however, the difference was not significant when navigated HTO was compared with conventional HTO performed using the gap measurement method. Tibial slope maintenance was comparable or better in navigated HTO. No difference was found in the American Knee Society function and Lysholm scores. Navigated HTO necessitated a longer operative time of approximately 10 minutes. CONCLUSIONS: The use of navigation in HTO can improve accuracy in both coronal and sagittal alignments, but its clinical benefit is unclear.
Fluoroscopy
;
Incidence
;
Knee
;
Methods
;
Operative Time
;
Osteoarthritis
;
Osteotomy
;
Surgery, Computer-Assisted
;
Tibia
;
Weight-Bearing
;
Weights and Measures

Result Analysis
Print
Save
E-mail