1.Evaluation of different bioimpedance methods for assessing body composition in Asian non-dialysis chronic kidney disease patients
Sean WY LEE ; Clara Lee Ying NGOH ; Horng Ruey CHUA ; Sabrina HAROON ; Weng Kin WONG ; Evan JC LEE ; Titus WL LAU ; Sunil SETHI ; Boon Wee TEO
Kidney Research and Clinical Practice 2019;38(1):71-80
BACKGROUND: Chronic kidney disease (CKD) is associated with fluid retention, which increases total body water (TBW) and leads to changes in intracellular water (ICW) and extracellular water (ECW). This complicates accurate assessments of body composition. Analysis of bioelectrical impedance may improve the accuracy of evaluation in CKD patients and multiple machines and technologies are available. We compared body composition by bioimpedance spectroscopy (BIS) against multi-frequency bioimpedance analysis (BIA) in a multi-ethnic Asian population of stable, non-dialysis CKD patients. METHODS: We recruited 98 stable CKD patients comprising 54.1% men and 70.4% Chinese, 9.2% Malay, 13.3% Indian, and 8.2% other ethnicities. Stability was defined as no variation in serum creatinine > 20% over three months. Patients underwent BIS analyses using a Fresenius body composition monitor, while BIA analyses employed a Bodystat Quadscan 4000. RESULTS: Mean TBW values by BIS and BIA were 33.6 ± 7.2 L and 38.3 ± 7.4 L; mean ECW values were 15.8 ± 3.2 L and 16.9 ± 2.7 L; and mean ICW values were 17.9 ± 4.3 L and 21.0 ± 4.9 L, respectively. Mean differences for TBW were 4.6 ± 1.9 L (P < 0.001), for ECW they were 1.2 ± 0.5 L (P < 0.001), and for ICW they were 3.2 ±1.8 L (P < 0.001). BIA and BIS measurements were highly correlated: TBW r = 0.970, ECW r = 0.994, and ICW r = 0.926. Compared with BIA, BIS assessments of fluid overload appeared to be more associated with biochemical and clinical indicators. CONCLUSION: Although both BIA and BIS can be used for body water assessment, clinicians should be aware of biases that exist between bioimpedance techniques. The values of body water assessments in our study were higher in BIA than in BIS. Ethnicity, sex, body mass index, and estimated glomerular filtration rate were associated with these biases.
Adult
;
Asian Continental Ancestry Group
;
Bias (Epidemiology)
;
Body Composition
;
Body Mass Index
;
Body Water
;
Creatinine
;
Electric Impedance
;
Glomerular Filtration Rate
;
Humans
;
Kidney Diseases
;
Male
;
Methods
;
Nutrition Assessment
;
Renal Insufficiency, Chronic
;
Spectrum Analysis
;
Water
2.Evaluation of the Impact of Iterative Reconstruction Algorithms on Computed Tomography Texture Features of the Liver Parenchyma Using the Filtration-Histogram Method
Pamela SUNG ; Jeong Min LEE ; Ijin JOO ; Sanghyup LEE ; Tae Hyung KIM ; Balaji GANESHAN
Korean Journal of Radiology 2019;20(4):558-568
OBJECTIVE: To evaluate whether computed tomography (CT) reconstruction algorithms affect the CT texture features of the liver parenchyma. MATERIALS AND METHODS: This retrospective study comprised 58 patients (normal liver, n = 34; chronic liver disease [CLD], n = 24) who underwent liver CT scans using a single CT scanner. All CT images were reconstructed using filtered back projection (FBP), hybrid iterative reconstruction (IR) (iDOSE4), and model-based IR (IMR). On arterial phase (AP) and portal venous phase (PVP) CT imaging, quantitative texture analysis of the liver parenchyma using a single-slice region of interest was performed at the level of the hepatic hilum using a filtration-histogram statistic-based method with different filter values. Texture features were compared among the three reconstruction methods and between normal livers and those from CLD patients. Additionally, we evaluated the inter- and intra-observer reliability of the CT texture analysis by calculating intraclass correlation coefficients (ICCs). RESULTS: IR techniques affect various CT texture features of the liver parenchyma. In particular, model-based IR frequently showed significant differences compared to FBP or hybrid IR on both AP and PVP CT imaging. Significant variation in entropy was observed between the three reconstruction algorithms on PVP imaging (p < 0.05). Comparison between normal livers and those from CLD patients revealed that AP images depend more strongly on the reconstruction method used than PVP images. For both inter- and intra-observer reliability, ICCs were acceptable (> 0.75) for CT imaging without filtration. CONCLUSION: CT texture features of the liver parenchyma evaluated using the filtration-histogram method were significantly affected by the CT reconstruction algorithm used.
Entropy
;
Filtration
;
Humans
;
Liver Diseases
;
Liver
;
Methods
;
Retrospective Studies
;
Tomography, X-Ray Computed
3.Facial aesthetic fat graft retention rates after filtration, centrifugation, or sedimentation processing techniques measured using three-dimensional surface imaging devices.
Guan-Hui-Er WANG ; Jian-Fang ZHAO ; Hong-Yu XUE ; Dong LI
Chinese Medical Journal 2019;132(1):69-77
OBJECTIVE:
How to increase the long-term retention rate of autologous fat grafting has been widely discussed. This study aimed to evaluate long-term fat graft retention rates for the most widely used fat processing methods in the area of facial esthetic surgery, including centrifugation, filtration, and sedimentation, using three-dimensional (3D) imaging.
DATA SOURCES:
PubMed, Embase, Wiley/Cochrane Library, and Web of Science databases were comprehensively searched from inception to July 2018 according to the guidelines of the American Society of Plastic Surgeons Fat Graft Task Force Assessment Methodology.
STUDY SELECTION:
Articles were screened using predetermined inclusion and exclusion criteria. Data collected included patient characteristics, follow-up devices, fat grafting techniques, and clinical outcomes. Patient cohorts were pooled, and fat graft retention rates were calculated. Complications were summarized according to different clinical characteristics.
RESULTS:
Of 77 articles, 10 clinical studies met the inclusion criteria and reported quantified measurement outcomes with 3D imaging which provide precise volumetric data with approximately 2% standard deviation compared to real volumes. Data of 515 patients were included. Fat grafting retention varied from 21% to 82%. We found filtration and centrifugation techniques could result in better retention outcomes. However, retention varied within each processing technique, with no significant difference among the 3 techniques. Twenty-two complications were reported among 515 patients, including donor-site hematoma (1 case), mild post-operative erythema (2 cases), mild volumetric asymmetries (2 cases), chronic edema (2 cases), overcorrection (2 cases), skin irregularity (6 cases), and headache or dysesthesia (7 cases).
CONCLUSIONS
Filtration and centrifugation techniques may result in better fat grafting retention outcomes than gravity sedimentation; however, more accurate statistical evidence is needed. Controversies continue to exist with respect to the performance of the different fat-processing techniques in fat graft retention.
Adipocytes
;
cytology
;
Adipose Tissue
;
cytology
;
Centrifugation
;
methods
;
Filtration
;
methods
;
Humans
;
Imaging, Three-Dimensional
;
methods
4.Increased Carotid Intima-Media Thickness (IMT) in Hyperuricemic Individuals May Be Explained by Hyperhomocysteinemia Associated with Renal Dysfunction: a Cross-Sectional Study
Ji Ho PARK ; Jung Soo SONG ; Sang Tae CHOI
Journal of Korean Medical Science 2019;34(37):e237-
BACKGROUND: Both hyperuricemia and hyperhomocysteinemia are known as main risk factors of cardiovascular diseases. There has been, however, no report on the relationship between carotid intima-media thickness (IMT) and homocysteine (Hcy) in hyperuricemic patients. This study aimed to investigate how hyperuricemia is associated with increased carotid IMT with a focus on hyperhomocysteinemia. METHODS: This cross-sectional study included 1,222 patients who visited the Chung-Ang University Hospital Health Promotion Center from January 2013 to December 2015. The serum Hcy levels were estimated with a competitive immunoassay using the direct chemiluminescence method. The carotid IMT was measured by B-mode carotid ultrasonography. The definition of hyperuricemia was a serum uric acid level > 7.0 mg/dL for men or > 5.6 mg/dL for women, and hyperhomocysteinemia was defined as serum levels > 15 μmol/L. RESULTS: The hyperuricemic patients showed significantly higher serum Hcy levels and lower estimated glomerular filtration rate (eGFR) than did normouricemic patients (13.39 ± 4.42 vs. 11.69 ± 3.65 μmol/L, P < 0.001; 85.16 ± 19.18 vs. 96.14 ± 16.63, P < 0.001, respectively). Serum Hcy level (odds ratio [OR], 1.050; 95% confidence interval [CI], 1.009–1.092) and fasting glucose level (OR, 1.018; 95% CI, 1.011–1.026) were independent risk factors for carotid plaque. In patients with hyperuricemia, the serum Hcy levels correlated with the eGFR (γ = −0.478, P < 0.001). The carotid IMT correlated with serum Hcy levels and eGFR (γ = 0.196, P = 0.008; γ = − 0.297, P < 0.001, respectively) but not with the serum lipid profile. CONCLUSION: These results suggest that renal function impairment in hyperuricemic patients may worsen carotid IMT by increasing serum Hcy levels.
Cardiovascular Diseases
;
Carotid Intima-Media Thickness
;
Cross-Sectional Studies
;
Fasting
;
Female
;
Glomerular Filtration Rate
;
Glucose
;
Health Promotion
;
Homocysteine
;
Humans
;
Hyperhomocysteinemia
;
Hyperuricemia
;
Immunoassay
;
Luminescence
;
Male
;
Methods
;
Risk Factors
;
Ultrasonography
;
Uric Acid
5.Annual Report on the External Quality Assessment Scheme for General Chemistry in Korea (2017).
Journal of Laboratory Medicine and Quality Assurance 2018;40(3):113-127
In 2017, the clinical chemistry proficiency testing program consisted of 24 programs with the addition of the urine chemistry program in the Korean Association of External Quality Assessment Service. The routine chemistry program consisted of 32 test items, including osmolality, total CO2, and estimated glomerular filtration rate tests, and the urine chemistry program consisted of 12 test items, including the albumin test. Based on the information and results of each test item entered by each institution, statistical analysis data according to test method, instrument, and reagent were reported. The statistics included the number of participating institutions, mean, standard deviation, coefficient of variation, median, minimum, and maximum values for each group. Each report was composed of a table, histogram, Levy-Jennings chart, and standard deviation index showing statistics by each test item. A total of 14 items, including albumin, were evaluated by more than 1,000 institutions, and the number of participating institutions is continuously increasing. The coefficient of variation tended to increase, as the concentration of the control material was lower for each test item. Most of them showed a coefficient of variation within 10%. Alkaline phosphatase and lactate dehydrogenase were found to have high coefficients of variation due to differences in measurement values between measurement methods. The distribution of measurement methods in general chemistry test items was not significantly different from that of previous years, and the distribution of measurement methods for albumin, glucose, phosphorus, and protein among the urine chemistry program was different from that of the routine chemistry program.
Alkaline Phosphatase
;
Chemistry*
;
Chemistry, Clinical
;
Glomerular Filtration Rate
;
Glucose
;
Korea*
;
L-Lactate Dehydrogenase
;
Methods
;
Osmolar Concentration
;
Phosphorus
6.A Comparison of the Accuracy of Different Single Plasma Sample Methods for Measuring Glomerular Filtration Rate Using ⁵¹Cr-EDTA in Children
Nuclear Medicine and Molecular Imaging 2018;52(4):293-302
PURPOSE: Among the different methods of measuring glomerular filtration rate (GFR) using 51Cr-ethylenediaminetetraacetic acid clearance, the two-plasma-sample method (TPSM) is widely used, and highly accurate. The single-plasma-sample method (SPSM) is occasionally used for simplicity, at the expense of accuracy. Our aims were (1) to investigate the correlation and (2) to compare the accuracy of six known SPSMs in pediatric patients in reference to TPSM.METHODS: We retrospectively reviewed 122 pediatric cases (65 boys, age 7.3 ± 4.6 years) and analyzed 307 GFR measurements. SPSMs included Groth and Aasted at 120 min, Hamat 120 min, Christensen and Groth at 120 and 240 min, and Jacobsson at 120 and 240 min. Reference GFR (GFRref) was defined using TPSM GFR corrected by the Jodal and Brochner-Mortensen equation. GFRref < 30 mL min−1 1.73 m−2 were excluded. The standard error of the estimate (SEE) and the number of cases with differences > 10% (N10%) were used to evaluate accuracy.RESULTS: SPSMs generally correlated well with GFRref (r = 0.92~0.99) and were relatively accurate (SEE = 9.21~15.60). Groth and Aasted showed the smallest SEE, while Jacobsson at 240 min showed the smallest N10% for all GFRref ranges. As for the decreased GFRref, Ham was most accurate followed by Jacobsson at 240 min.CONCLUSIONS: Jacobsson at 240 min provided good accuracy in all GFRref ranges and was well correlated with TPSM. Jacobsson at 240 min might be the most appropriate method to substitute for TPSM in pediatric patients. Ham could be an alternative in patients with impaired renal function.
Child
;
Glomerular Filtration Rate
;
Humans
;
Methods
;
Plasma
;
Retrospective Studies
7.Physician perceptions of blood pressure control in patients with chronic kidney disease and target blood pressure achievement rate.
Ran hui CHA ; Hajeong LEE ; Jung Pyo LEE ; Young Rim SONG ; Sung Gyun KIM ; Yon Su KIM
Kidney Research and Clinical Practice 2017;36(4):349-357
BACKGROUND: Blood pressure (BP) control is the most-established method for the prevention of chronic kidney disease (CKD) progression. However, the ideal BP target for CKD patients is still under debate. METHODS: We performed a survey of regular registered members of the Korean Society of Nephrology to determine physician perceptions of BP control in patients with CKD. In addition, we evaluated the target BP achievement rate using data from the APrODiTe-2 study. RESULTS: Two-thirds of physicians considered the target BP for CKD to be < 130/85 mmHg. The systolic BP (SBP) thresholds for diabetic CKD, proteinuria ≥ 300 mg/day, 30 ≤ glomerular filtration rate (GFR) < 60 mL/min/1.73 m2, age < 60 years, and the presence of atherosclerotic (ASO) complications were significantly lower than the SBP thresholds of the opposite parameters. The three major hurdles to controlling BP were non-compliance with lifestyle modification and medications, and self-report of well-controlled home BP. Most physicians prescribed home and ambulatory BP monitoring to less than 50% of their patients. The target BP achievement rates using the SBP thresholds in this survey were as follows: non-diabetic (69.3%); diabetic (29.5%); proteinuria < 300 mg/day (72.3%); proteinuria > 300 mg/day (33.7%); GFR ≥ 60 (76.4%); GFR < 30 (47.8%); no evidence of ASO (67.8%); and the presence of ASO (42.9%). CONCLUSION: The target BP was lower in patients with higher cerebro-cardiovascular risks. These patient groups also showed lower target BP achievement rates. We also found a relatively lower application and clinical reflection rate of home or ambulatory BP monitoring.
Blood Pressure*
;
Glomerular Filtration Rate
;
Humans
;
Life Style
;
Methods
;
Nephrology
;
Proteinuria
;
Renal Insufficiency, Chronic*
8.Proposal of Evaluation Method for Leukoreduction Blood Filter and Evaluation of Domestic Filter.
Geon Sik SHIN ; Sung Hoon KIM ; Bohee KIM ; Kyeong Rak LEE ; Jae Won KANG ; Kwang HUH ; Juwon KIM ; Ki Jong RHEE ; Yoon Suk KIM
Korean Journal of Blood Transfusion 2017;28(3):256-263
BACKGROUND: A leukoreduction filter was recently developed in Korea to reduce various kinds of adverse transfusion reactions. The objective of this study was to propose a domestic evaluation system for leukoreduction filters and to apply this evaluation system to assess the newly developed leukoreduction filter. METHODS: We prepared packed red blood cells from 60 units of whole blood (400 mL) collected from 60 normal individuals and evaluated the efficacy of the newly developed filter (FINECELL, KOLON INDUSTRIES, Gumi, Korea) and a control filter (RCM1, Haemonetics, MA, USA). To verify the evaluation system, we assessed the filtration time, residual leukocyte count, RBC recovery, RBC hemolysis, hemoglobin concentration, and hematocrit using a control filter RCM1 and compared the results with those of an evaluation performed by the American Red Cross (ARC) in 2013. We then evaluated the efficacy of the test filter FINECELL using the methods established in this study and compared the results with those of the control filter RCM1. RESULTS: The results of the current study were similar to those of the ARC with the control filters. The test filters developed in Korea were not inferior to commonly used control filters regarding residual leukocyte count, RBC recovery, and RBC hemolysis at 35 days after filtration. All of the results in the evaluation satisfied the international standards. CONCLUSION: These results of this study showed that the efficacy of the newly developed domestic leukoreduction filter were satisfactory and will contribute to improvement of quality of blood components in Korea.
Erythrocytes
;
Filtration
;
Gyeongsangbuk-do
;
Hematocrit
;
Hemolysis
;
Korea
;
Leukocyte Count
;
Methods*
;
Red Cross
;
Transfusion Reaction
9.Efficient Method for the Rapid Purification of Nosema ceranae Spores.
Dong Jun KIM ; Hwi Geon YUN ; In Hui KIM ; Won Seok GWAK ; Soo Dong WOO
Mycobiology 2017;45(3):204-208
Nosema ceranae is an obligate intracellular fungal parasite that causes mortality in honey bees and enhances the susceptibility of honey bees to other pathogens. Efficient purification of Nosema spores from the midgut of infected honey bees is very important because Nosema is non-culturable and only seasonably available. To achieve a higher yield of spores from honey bees, in this study, we considered that the initial release of spores from the midgut tissues was the most critical step. The use of 2 mm beads along with enzymatic treatment with collagenase and trypsin enhanced the homogenization of tissues and the yield of released spores by approximately 2.95 times compared with the use of common 3 mm beads alone. The optimal time for the enzyme treatment was determined to be 1 hr as measured by the yield and viability of the spores. A one-step filtration using a filter paper with an 8–11 µm pore size was sufficient for removing cell debris. This method may be useful to purify not only N. ceranae spores but also other Nosema spp. spores.
Bees
;
Collagenases
;
Filtration
;
Honey
;
Methods*
;
Mortality
;
Nosema*
;
Parasites
;
Seasons
;
Spores*
;
Trypsin
10.Self-Management Programs on eGFR, Depression, and Quality of Life among Patients with Chronic Kidney Disease: A Meta-Analysis.
Mei Chen LEE ; Shu Fang Vivienne WU ; Nan Chen HSIEH ; Juin Ming TSAI
Asian Nursing Research 2016;10(4):255-262
PURPOSE: Chronic kidney disease (CKD) is a condition characterized by the gradual loss of kidney function over time. Self-management programs have been widely applied to chronic disease education programs, which are designed to delay deteriorating kidney functions, preclude depression, and improve quality of life. This study aims to analyze effectiveness of self-management programs in bettering CKD patients' eGFR, mitigating depression symptoms and improving quality of life in randomized control or clinical trials. METHODS: Using key terms, a search was conducted in English-language, peer-reviewed journals on CKD that were published between 2002 and 2014 on databases including CINAHL, Cochrane Library, MEDLINE. The measurable variables included CKD patients' eGFR, depression, and quality of life. Random and fixed effects meta analysis were applied with standard error and correlation based measure of effect size. RESULTS: Eight studies met the inclusion criteria. A self-management program significantly impacted CKD patients' depression and mental quality-of-life dimensions, with an effect size of .29 [95% confidence interval (CI) (0.07, 0.53)] and −.42 [95% CI (−0.75, −0.10)]. However, the intervention of a self-management program had no significant effect on patients' eGFR as well as physical quality-of-life dimensions, with effect sizes of .06 [95% CI (−0.69, 0.81)] and −.16 [95% CI (−0.81, 0.50)]. CONCLUSIONS: Self-management programs of patients with chronic kidney disease can improve the depression and mental quality of life. Aside from providing more objective evidence-based results, this study provides a reference for clinical health care personnel who tend to patients with CKD.
Cognitive Therapy/methods
;
Depressive Disorder/*etiology/therapy
;
Glomerular Filtration Rate/*physiology
;
Humans
;
*Quality of Life
;
Randomized Controlled Trials as Topic
;
Renal Insufficiency, Chronic/physiopathology/psychology/*therapy
;
Self Care/*methods

Result Analysis