1.The effect of high-pass filter circuit on accurate measurement of ST-segment.
Yantao SONG ; Caibing ZHU ; Lanlan WEI ; Fan WANG ; Jilun YE ; Xu ZHANG ; Xiaodong HUANG
Chinese Journal of Medical Instrumentation 2013;37(5):319-321
The high-pass filter which is designed to overcome the polarization voltage in the ECG measurements can affect the measurement of the ST-segment; but the accuracy of the ST-segment will have an impact on the diagnosis and treatment of heart diseases. This paper used the ECG detection platform to test the effect of the high-pass filter at different frequency and studied the effect of the high-pass filter on the ST segment to ensure proper use of different application modes.
Electrocardiography
;
instrumentation
;
methods
;
Filtration
2.Effect of Charcoal Filter on the Emergence from Sevoflurane Anesthesia in a Semi-Closed Rebreathing Circuit.
Dong Jin CHANG ; Seung Ho CHOI ; Yong Suk CHOI ; Kyeong Tae MIN
Yonsei Medical Journal 2011;52(4):668-672
PURPOSE: A charcoal filter attached within the anesthetic circuit has been shown to efficiently adsorb halothane or isoflurane, thus hastening anesthetic recovery in low or minimal flow system. This study was intended to demonstrate whether the charcoal filter enhances the recovery time from sevoflurane anesthesia using a semi-closed circuit system. MATERIALS AND METHODS: Thirty healthy patients scheduled for elective surgery under sevoflurane anesthesia were randomly assigned to the charcoal filter or control group. Upon completion of surgery, the end-tidal concentration of sevoflurane was maintained at 2.0 vol%. A charcoal filter was attached to the expiratory limb of the breathing circuit of charcoal filter group subjects. After sevoflurane was discontinued, ventilation was controlled with the same minute volume as the intra-operative period at a fresh gas flow rate of 5 L.min(-1) with 100% O2. The elimination kinetics of sevoflurane from end-tidal concentration, Bispectral index and times of eye opening and extubation were obtained. RESULTS: The exponential time constant (tau) of alveolar sevoflurane concentration in the charcoal filter group was significantly shorter than that in the control group (1.7+/-0.5 vs. 2.5+/-1.1 min, p=0.008). The charcoal filter hastened rapid eye opening (11.1+/-3.8 vs. 14.8+/-3.0 min, p=0.007) and extubation (11.9+/-3.9 vs. 15.3+/-3.2 min, p=0.014), compared to the control group. CONCLUSION: A charcoal filter enhances the recovery from sevoflurane anesthesia with a semi-closed rebreathing circuit.
Adult
;
Anesthesia/methods
;
*Anesthesia Recovery Period
;
Anesthesiology/instrumentation
;
Anesthetics, Inhalation/chemistry/*pharmacology
;
Charcoal/*chemistry
;
Filtration/*methods
;
Humans
;
Methyl Ethers/chemistry/*pharmacology
;
Middle Aged
;
Time Factors
3.Study on concentration of nuorovirus genegroup II from environmental water.
Sha LIANG ; Guang-cheng XIE ; Zi-qian XU ; Jin-song LI ; Dan-tong LI ; Shao-long FENG ; Zhao-jun DUAN
Chinese Journal of Virology 2011;27(1):58-63
A new viral sampling concentration device was designed which was equipped with a new cationic filter membrane-Nanoceram suitable for field sampling. Norovirus Genegroup II was detected from environmental water with the aid of this device. The effects on virus recovery of prefiltration, various second-concentration methods, and different eluants were investigated through pre-experiment. The concentration optimized process, and the optimal concentration process were then determined. The results showed that the prefiltration had a profound effect on virus recovery, and two second-concentration method: PEG-NaC1 precipitation and celite adsorption, had almost the same concentration effects. The Na2 HPO4 solution of 0.15 mol/L was selected as the final eluant to elute the adsorbed Nuorovirus from the celite. The virus recovery of Nanoceram was determined to be 3.02%. Finally, successful detection of Norovirus GII in sewage from Yangqiao River, Fengtai District, Beijing was acheived. All these data had shown that the Naneceram filter concentration method could concentrate Norovirus from environmental water with a steady effects.
Filtration
;
instrumentation
;
methods
;
Fractional Precipitation
;
instrumentation
;
methods
;
Genotype
;
Norovirus
;
classification
;
genetics
;
isolation & purification
;
Rivers
;
virology
;
Water Microbiology
4.Study on separation of essential oil of Caryophylli flos from oil-in-water emulsion by microfiltration.
Zhifeng HAN ; Jie SHEN ; Liwei GUO ; Wenlin FAN
China Journal of Chinese Materia Medica 2011;36(1):41-44
OBJECTIVETo separate essential oil of Caryophyllix flos from oil-in-water emulsion, and to enrich the essential oil by microfiltration (MF).
METHODUsing membrane flux and removal rate of COD as the indicatrixes, the membrane material as well as the operating conditions containing pressure, surface speed, temperature were optimized.
RESULTThe results showed that QWLM membrane of hydrophilic is the proper membrane, and the best operating conditions was at 0.06 MPa, 60 degrees C, and 150 r min(-1) stir speed.
CONCLUSIONIt can be concluded that MF is a reasonable way to enrich essential oil of C. flox.
Emulsions ; chemistry ; Filtration ; instrumentation ; methods ; Membranes, Artificial ; Oils, Volatile ; chemistry ; isolation & purification ; Plant Oils ; chemistry ; isolation & purification ; Syzygium ; chemistry
5.Research for the test method of polypropylene fiber liquid filtration membrane particles shedding.
Jinzi SONG ; Yufei JIA ; Yulian CHAI ; Bingcheng SUN ; Haixin LI
Chinese Journal of Medical Instrumentation 2011;35(6):446-448
Through five experiments, such as "Circle", "square", "side that does not shake", "burning edge", "filter", this paper discussed the effect of different experimental methods of polypropylene fiber liquid filtration membrane particles shedding. The results show that: the particles falling off the edge of the polypropylene fiber Double-sided liquid filtration membrane are very important and must be considered off the evaluation of particle pollution.
Equipment Failure
;
Filtration
;
instrumentation
;
methods
;
Particle Size
;
Polypropylenes
6.Bacterial community and function of biological activated carbon filter in drinking water treatment.
DuoYing ZHANG ; WeiGuang LI ; ShuMei ZHANG ; Miao LIU ; XiaoYu ZHAO ; XianCheng ZHANG
Biomedical and Environmental Sciences 2011;24(2):122-131
OBJECTIVEIt aims to investigate the changes in composition and structure of bacterial communities developing on biological activated carbon (BAC) particles, and the bacterial functions.
METHODA pilot plant had been in service for 180 days, aiming to develop bacterial communities on activated carbon naturally. After 180 days of operation, the bacterial communities were determined by denaturing gradient gel electrophoresis (DGGE) analyses of PCR-amplified 16S rRNA genes. The study on community composition and the phylogenetic relationships of the organisms was complemented by a sequence analysis of cloned PCR products from 16S rRNA genes. Gas chromatography-mass (GC-MS) measurement was used to determine organic chemical composition of inflow and outflow water on the 300th day. TOC and NH(4)(+)-N were also tested in this experiment.
RESULTSIt showed that the stable bacterial structure did not develop on BAC particles until the 9th month during running time of the BAC filter. The communities were finally dominated by Pseudomonas sp., Ba-cillus sp., Nitrospira sp., and an uncultured bacterium. Stable bacterial communities played an important role in removal of NH(4)(+)-N and total organic carbon (TOC). Results from gas chromatography-mass (GC-MS) showed that 36 kinds of chemicals in feed water were eliminated, and concentrations of 5 kinds of chemicals decreased. These chemicals served as nutrients for the dominant bacteria.
CONCLUSIONThe findings from the study suggested that the stability of microbial structure was beneficial for improving NH(4)(+)-N and TOC removal efficiencies. The dominant bacteria had the advantage of biode-grading a wide range of organic chemicals and NH(4)(+)-N.
Ammonia ; chemistry ; Bacteria ; classification ; genetics ; Biofilms ; Carbon ; chemistry ; Filtration ; instrumentation ; methods ; Microscopy, Electron, Scanning ; Pilot Projects ; Waste Disposal, Fluid ; instrumentation ; methods ; Water Microbiology ; Water Purification ; instrumentation ; methods ; Water Supply ; standards
7.Study and compare of the bidirectional filtering technique for anti-baseline drift.
Lingfeng KONG ; Daxue WEI ; Yunpeng LIAO
Chinese Journal of Medical Instrumentation 2010;34(4):263-265
Several digital filtering techniques for correcting baseline drift from ECG signals are presented. A bidirectional filter is introduced, which can cantain baseline drift their filtering performance and realization methods are compared.
Electrocardiography
;
instrumentation
;
methods
;
Filtration
;
instrumentation
;
Signal Processing, Computer-Assisted
;
instrumentation
8.Effect of solution environments on ceramic membrane microfiltration of model system of Chinese medicines.
Lianjun ZHANG ; Jin LU ; Kang LE ; Tingming FU ; Liwei GUO
China Journal of Chinese Materia Medica 2010;35(13):1691-1695
OBJECTIVETo investigate the effect of differents solution environments on the ceramic membrane microfiltration of model system of Chinese medicines.
METHODTaking binary system of soybean protein-berberine as the research object, flux, transmittance of berberine and traping rate of protein as indexes, different solution environment on membrane process were investigated.
RESULTWhen the concentration of soybean protein was under 1 g x L(-1), the membrane flux was minimum with the traping of berberine decreased slightly as the concentration increased. When pH was 4, the flux was maximum with the traping rate of protein was 99%, and the transmittance of berberine reached above 60%.
CONCLUSIONThe efficiency of membrane separation can be improved by optimizing the solution environment of water-extraction of chinese medicines. The efficiency of membrane separation is the best when adjust the pH to the isoelectric point of proteins for the proteins as the main pollutant in aqueous solution.
Berberine ; chemistry ; Drugs, Chinese Herbal ; chemistry ; Filtration ; instrumentation ; methods ; Hydrogen-Ion Concentration ; Kinetics ; Models, Theoretical ; Solutions ; chemistry ; Soybean Proteins ; chemistry
9.The effect of leukocyte depletion by filtration on the quality of apheresis platelets.
Yang YU ; Qian FENG ; Ting ZHANG ; Chun-Ya MA ; Xiao-Juan ZHANG ; Guo-Feng GE ; Zi-Lin LIN ; Ji-Chun PAN ; De-Qing WANG ; Qun LUO ; Ya-Ping TIAN
Journal of Experimental Hematology 2009;17(4):1067-1070
This study was aimed to investigate the effect of leukocyte depletion by filtration on the quality of apheresis platelets. 20 units of donor apheresis platelets were randomly selected and were preserved with agitation at 20 - 24 degrees C for 24 - 96 hours, then were filtered on polyester flatbed filters. The platelet concentration, mean platelet volume (MPV), volume of apheresis platelets, leukocyte count, pH value, lactate dehydrogenase (LDH) concentration, K(+) concentration and CD62p expression level on surface of platelet membrane, were detected before and after filtration, as well as the rate of leukocyte depletion and platelet loss were calculated. The results showed that the leukocyte count after filtration was remarkably lower than that before filtration (p < 0.001), and the rate of leukocyte depletion was 99.97%. Platelet loss was approximately 8%, and obviously lower than that of the national standard (p < 0.001). MPV, pH value, K(+) and LDH concentration were not significantly different before and after filtration. Compared with platelets before filtration, CD62p expression level after filtration slightly decreased (p > 0.05). CD62p expression on surface of platelet membrane in perfusion fluid obtained from filter plate was obviously higher than that before filtration (p < 0.05). MA of platelet after filtration slightly decreased (p > 0.05). It is concluded that leukocyte and partial activated platelets can be removed efficiently by using polyester flatbed filters, and platelet loss is very low. Filtration does not adversely affect coagulation activity of the platelets in vitro. Apheresis platelets after filtration can fulfil quality requirements to prevent infection of cytomegalovirus and HLA alloimmunization.
Filtration
;
Humans
;
Leukapheresis
;
instrumentation
;
Platelet Count
;
Plateletpheresis
;
instrumentation
;
methods
10.Double filtration plasmapheresis in treatment of hyperlipidemic acute pancreatitis.
Ge ZHANG ; Jian FENG ; Qiu-ping XU ; Hai-ying HUANG
Journal of Zhejiang University. Medical sciences 2008;37(1):93-96
OBJECTIVETo investigate the therapeutic effects of double filtration plasmapheresis(DFPP) in treatment of hyperlipidemic acute pancreatitis.
METHODSNine patients with acute hyperlipidemic pancreatitis were treated with DFPP in addition to the conventional therapeutic measures. The clinical symptoms,serum levels of triglyceride (TG) and APACHE II scores were observed before and after DFPP.
RESULTAfter DFPP the clinical symptoms of patients were improved greatly; serum levels of TG decreased from (83.48 +/-2.54)mmol/L to (4.09 +/-0.65)mmol/L(P<0.01) and APACHE II scores decreased from 12.2 +/- 2.3 to 6.2 +/- 1.3(P <0.05). There were no significant side effects during and after DFPP.
CONCLUSIONDFPP can be effectively and safely applied in patients with acute hyperlipidemic pancreatitis.
Acute Disease ; Adult ; Female ; Filtration ; methods ; Hemofiltration ; methods ; Humans ; Hyperlipidemias ; etiology ; therapy ; Male ; Middle Aged ; Pancreatitis ; complications ; therapy ; Pancreatitis, Acute Necrotizing ; therapy ; Plasmapheresis ; instrumentation ; Young Adult