1.Application of soft tissue loosening and acetabular reconstruction in hip replacement for patients with severe femoral head necrosis.
Shuai LI ; Wei ZHU ; Zhengxiao OUYANG ; Dan PENG
Journal of Central South University(Medical Sciences) 2019;44(7):790-794
To explore the effect of application of soft tissue loosening and acetabular reconstruction in hip replacement for patients with severe femoral head necrosis on joint function.
Methods: From June 2012 to August 2016, 68 patients with severe femoral head necrosis (Ficat III, IV) underwent total hip replacement with soft tissue release and acetabular reconstruction at the Second Xiangya Hospital of Central South University. Total hip replacement is performed by the posterolateral approach. The acetabulum was rebuilt and the length of the affected limb was prolonged after clearing the scar tissue, proliferating the epiphysis, releasing the abductor muscle group and the adductor muscle group, dissecting the soft tissue around the acetabulum. One year after surgery, Harris score, X-ray positive lateral radiograph for the affected side and full-length X-ray examination for both lower extremities were performed to evaluate the curative effect.
Results: The postoperative follow-up time ranged from 1.0 to 5.5 years. All patients' femoral heads returned to normal anatomical position and the affected limb length was restored to 1.5-3.5 cm; all patients did not damage the sciatic nerve. The Harris scores for 68 patients increased from 38.6±7.5 to 78.2±5.7 (P=0.029) in the first year after surgery.
Conclusion: During hip replacement surgery for severe femoral head necrosis, soft tissue dissection and acetabular reconstruction can be used to ensure anatomical reconstruction for the acetabular fossa and to improve abductor function.
Acetabulum
;
Arthroplasty, Replacement, Hip
;
Femur Head
;
Femur Head Necrosis
;
surgery
;
Follow-Up Studies
;
Humans
;
Radiography
;
Treatment Outcome
2.Long-term results of the Scorpio posterior-stabilized total knee arthroplasty.
Qunjie ZHONG ; Xin ZHI ; Jianhao LIN ; Houshan LYU
Chinese Journal of Surgery 2016;54(4):247-250
OBJECTIVETo evaluate long-term result of Scorpio posterior-stabilized total knee arthroplasty.
METHODSThere were 160 patients (240 knees) underwent Scorpio posterior-stabilized total knee arthroplasty between December 1998 and December 2000, which were performed by the same surgeon. Patients were followed up from June 2013 to December 2013. Knee Society Scoring (KSS), Hospital for Special Surgery (HSS) patellofemoral scoring, standard weight-bearing anteroposterior and patellar tangential radiographs were assessed. Satisfaction of outcome was requested. Alignment of components and presence of radiolucent lines were assessed by the radiographic scoring system of knee society. Paired t-test was used compared to the data between preoperation and the time of last follow-up.
RESULTSNinety-five patients (141 knees) (59.4%) were followed up. Average follow-up duration was 13.3 years (range 12 to 15 years). Eight knees were revised due to periprosthetic infection (4 knees), aseptic loosening of tibial tray (3 knees) and wear-out of polyethylene insert (1 knee). Compared with preoperative ones, KSS knee score, KSS functional score and range of motion improved significantly (pre-operation: 26±16, 34±18, 87°±25°; follow-up time: 93±8, 78±27, 114°±22°) (t=45.55, 15.60, 13.03, all P<0.01). In terms of KSS knee score and HSS patellofemoral score, 106 knees were rated as excellence respectively. Ninety-five knees had satisfaction with outcome for maximum. The presences of radiolucent lines occurred around 5 femoral and 11 tibial components with range less than 2 mm. The survival rate at 10 years was 94.5% with revision for any reason as the end point.
CONCLUSIONThe long-term study indicates that Scorpio posterior-stabilized knee system shows favorable clinical and radiological results.
Arthroplasty, Replacement, Knee ; methods ; Femur ; diagnostic imaging ; Follow-Up Studies ; Humans ; Knee Joint ; surgery ; Knee Prosthesis ; Patella ; diagnostic imaging ; Polyethylene ; Radiography ; Range of Motion, Articular ; Reoperation ; Tibia ; diagnostic imaging ; Treatment Outcome
3.Is There a Reliable Method to Predict the Limb Length Discrepancy after Chemotherapy and Limb Salvage Surgery in Children with Osteosarcoma?
Yuan LI ; Feng LIAO ; Hai-Rong XU ; Xiao-Hui NIU
Chinese Medical Journal 2016;129(16):1912-1916
BACKGROUNDFor a child with osteosarcoma, prediction of the limb length discrepancy at maturity is important when planning for limb salvage surgery. The purpose of this study was to provide a reliable prediction method.
METHODSA retrospective review of Chinese children receiving chemotherapy for osteosarcoma before skeletal maturity was conducted. Standing full-length radiographs of the lower extremity were used for length measurements. Length-for-age curves were constructed using the LMS method. The lower limb multiplier for a specific age and gender was calculated using the formula M = Lm/L, where M was the gender- and age-specific multiplier, Lmwas the bone length at maturity, and L was the age-specific bone length. Prematurity and postmaturity radiographs were used to assess the accuracy of the prediction methods.
RESULTSA total of 513 radiographs of 131 boys and 314 radiographs of 86 girls were used to calculate the coefficients of the multiplier. The multipliers of 8-, 9-, 10-, 11-, 12-, 13-, 14-, 15-, 16-, 17-, and 18-year-old boys after chemotherapy for osteosarcoma were 1.394, 1.306, 1.231, 1.170, 1.119, 1.071, 1.032, 1.010, 1.004, 1.001, and 1.000, respectively; while for girls at the same ages, the multipliers were 1.311, 1.221, 1.146, 1.092, 1.049, 1.021, 1.006, 1.001, 1.000, 1.000, and 1.000, respectively. Prematurity and postmaturity femoral and tibial lengths of 21 patients were used to assess the prediction accuracy. The mean prediction error was 0 cm, 0.8 cm, and 1.6 cm for the multiplier method using our coefficients, Paley's coefficients, and Anderson's method, respectively.
CONCLUSIONSOur coefficients for the multiplier method are reliable in predicting lower limb length growth of Chinese children with osteosarcoma.
Adolescent ; Body Height ; physiology ; Bone Neoplasms ; surgery ; Child ; Female ; Femur ; anatomy & histology ; Humans ; Limb Salvage ; Lower Extremity ; anatomy & histology ; Male ; Models, Theoretical ; Osteosarcoma ; surgery ; Radiography ; Retrospective Studies ; Tibia ; anatomy & histology
4.Calcar Preservation Arthroplasty for Unstable Intertrochanteric Femoral Fractures in Elderly.
Mustafa CELIKTAS ; Emre TOGRUL ; Ozkan KOSE
Clinics in Orthopedic Surgery 2015;7(4):436-442
BACKGROUND: The treatment of unstable intertrochanteric fractures in elderly is still controversial. The purpose of this study is to present treatment strategies for unstable intertrochanteric fractures with hemiarthroplasty using standard uncemented collared femoral stems and at the same time preserving the fractured calcar fragment. METHODS: Fifty-four patients aged 75 years or older with unstable intertrochanteric fractures were included in this prospective cohort study. All patients were treated with calcar preserving hemiarthroplasty using cementless collored femoral stems. Fractured calcar fragment was stabilized either by compaction between the implant and femur or fixed with cable grip system. Follow-up evaluations were performed at least 24 months and later. Palmer and Parker mobility score and visual analogue scale (VAS) pain score were assessed. We also analyzed radiographs of the operated hip at each follow-up visit. RESULTS: The patients were 15 males and 39 females with a mean age of 81.3 years (range, 75 to 93 years). The average operative time was 86.6 minutes. The mean transfused blood units were 1.2 units. The average duration of hospital stay was 5.3 days. The preoperative mean mobility score was 6.20. This score was found to be 4.96 on postoperative third day and 5.90 at 24 months postoperatively. The results of the statistical analysis revealed significant increase in the mobility scores at each follow-up after three days. Radiological interpretation revealed no loosening in the cable-grip systems, and no significant subsidence (> 5 mm) of prosthesis was observed. CONCLUSIONS: Calcar preservation arthroplasty is a good option for elderly patients with severe osteoporosis, frail constitution and the patients who are at higher risk for second operation due to unstable intertrochanteric fractures.
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Hip/adverse effects/*methods
;
Female
;
Femur/pathology/radiography/surgery
;
Hemiarthroplasty/adverse effects/*methods
;
Hip/pathology/radiography/surgery
;
Hip Fractures/physiopathology/radiography/*surgery
;
Humans
;
Male
;
Pain Measurement
;
Postoperative Complications
;
Prospective Studies
5.Limb Lengthening in Patients with Achondroplasia.
Kwang Won PARK ; Rey An Nino GARCIA ; Chastity Amor REJUSO ; Jung Woo CHOI ; Hae Ryong SONG
Yonsei Medical Journal 2015;56(6):1656-1662
PURPOSE: Although bilateral lower-limb lengthening has been performed on patients with achondroplasia, the outcomes for the tibia and femur in terms of radiographic parameters, clinical results, and complications have not been compared with each other. We proposed 1) to compare the radiological outcomes of femoral and tibial lengthening and 2) to investigate the differences of complications related to lengthening. MATERIALS AND METHODS: We retrospectively reviewed 28 patients (average age, 14 years 4 months) with achondroplasia who underwent bilateral limb lengthening between 2004 and 2012. All patients first underwent bilateral tibial lengthening, and at 9-48 months (average, 17.8 months) after this procedure, bilateral femoral lengthening was performed. We analyzed the pixel value ratio (PVR) and characteristics of the callus of the lengthened area on serial radiographs. The external fixation index (EFI) and healing index (HI) were computed to compare tibial and femoral lengthening. The complications related to lengthening were assessed. RESULTS: The average gain in length was 8.4 cm for the femur and 9.8 cm for the tibia. The PVR, EFI, and HI of the tibia were significantly better than those of the femur. Fewer complications were found during the lengthening of the tibia than during the lengthening of the femur. CONCLUSION: Tibial lengthening had a significantly lower complication rate and a higher callus formation rate than femoral lengthening. Our findings suggest that bilateral limb lengthening (tibia, followed by femur) remains a reasonable option; however, we should be more cautious when performing femoral lengthening in selected patients.
Achondroplasia/*surgery
;
Adolescent
;
Bone Lengthening/*methods
;
Child
;
Child, Preschool
;
Female
;
Femur/radiography/*surgery
;
Humans
;
Male
;
Retrospective Studies
;
Tibia/radiography/*surgery
;
Treatment Outcome
;
Young Adult
6.How to Minimize Rotational Conflict between Femoral & Tibial Component in Total Knee Arthroplasty: The Use of Femoro-Tibial Axial Synchronizer (Linker).
Jai Gon SEO ; Young Wan MOON ; Sang Min KIM ; Sang Hoon PARK
Yonsei Medical Journal 2015;56(2):454-459
PURPOSE: The purpose of this study was to investigate the correlation between rotational axes of femur and tibia with the use of Linker. MATERIALS AND METHODS: This study was carried out from August 2009 to February 2010 on 54 patients (106 knees), who were diagnosed with simultaneous bilateral total knee arthroplasty. With the use of postoperative computed tomography scans, it was investigated how much the rotational angle of femoral and tibial components matched. RESULTS: The tibial component was internally rotated for the femoral component at an angle of 0.8degrees. The femoral component was externally rotated for the surgical transepicondylar axis (TEA) at an angle of 1.6 (range: from 4.8degrees of internal rotation to 7.9degrees of external rotation, SD=2.2degrees), and the tibial component was externally rotated for the surgical TEA at an average angle of 0.9 (range: from 5.1degrees of internal rotation to 8.3degrees of external rotation, SD=3.1degrees). CONCLUSION: The femoro-tibial synchronizer helped to improve the orientation and positioning of both femoral component and tibial component, and also increase the correlation of the rotational axes of the two components.
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/*methods
;
Female
;
Femur/*radiography/surgery
;
Humans
;
Knee
;
Knee Joint/*radiography/surgery
;
Knee Prosthesis
;
Male
;
Middle Aged
;
Reference Values
;
Rotation
;
Tibia/*radiography/surgery
;
Tomography, X-Ray Computed/*methods
7.How to Minimize Rotational Conflict between Femoral & Tibial Component in Total Knee Arthroplasty: The Use of Femoro-Tibial Axial Synchronizer (Linker).
Jai Gon SEO ; Young Wan MOON ; Sang Min KIM ; Sang Hoon PARK
Yonsei Medical Journal 2015;56(2):454-459
PURPOSE: The purpose of this study was to investigate the correlation between rotational axes of femur and tibia with the use of Linker. MATERIALS AND METHODS: This study was carried out from August 2009 to February 2010 on 54 patients (106 knees), who were diagnosed with simultaneous bilateral total knee arthroplasty. With the use of postoperative computed tomography scans, it was investigated how much the rotational angle of femoral and tibial components matched. RESULTS: The tibial component was internally rotated for the femoral component at an angle of 0.8degrees. The femoral component was externally rotated for the surgical transepicondylar axis (TEA) at an angle of 1.6 (range: from 4.8degrees of internal rotation to 7.9degrees of external rotation, SD=2.2degrees), and the tibial component was externally rotated for the surgical TEA at an average angle of 0.9 (range: from 5.1degrees of internal rotation to 8.3degrees of external rotation, SD=3.1degrees). CONCLUSION: The femoro-tibial synchronizer helped to improve the orientation and positioning of both femoral component and tibial component, and also increase the correlation of the rotational axes of the two components.
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/*methods
;
Female
;
Femur/*radiography/surgery
;
Humans
;
Knee
;
Knee Joint/*radiography/surgery
;
Knee Prosthesis
;
Male
;
Middle Aged
;
Reference Values
;
Rotation
;
Tibia/*radiography/surgery
;
Tomography, X-Ray Computed/*methods
8.Volume and Contact Surface Area Analysis of Bony Tunnels in Single and Double Bundle Anterior Cruciate Ligament Reconstruction Using Autograft Tendons: In Vivo Three-Dimensional Imaging Analysis.
Jae Hyuk YANG ; Minho CHANG ; Dai Soon KWAK ; Joon Ho WANG
Clinics in Orthopedic Surgery 2014;6(3):290-297
BACKGROUND: Regarding reconstruction surgery of the anterior cruciate ligament (ACL), there is still a debate whether to perform a single bundle (SB) or double bundle (DB) reconstruction. The purpose of this study was to analyze and compare the volume and surface area of femoral and tibial tunnels during transtibial SB versus transportal DB ACL reconstruction. METHODS: A consecutive series of 26 patients who underwent trantibial SB ACL reconstruction and 27 patients with transportal DB ACL reconstruction using hamstring autograft from January 2010 to October 2010 were included in this study. Three-dimensional computed tomography (3D-CT) was taken within one week after operation. The CT bone images were segmented with use of Mimics software v14.0. The obtained digital images were then imported in the commercial package Geomagic Studio v10.0 and SketchUp Pro v8.0 for processing. The femoral and tibial tunnel lengths, diameters, volumes and surface areas were evaluated. A comparison between the two groups was performed using the independent-samples t-test. A p-value less than the significance value of 5% (p < 0.05) was considered statistically significant. RESULTS: Regarding femur tunnels, a significant difference was not found between the tunnel volume for SB technique (1,496.51 +/- 396.72 mm3) and the total tunnel volume for DB technique (1,593.81 +/- 469.42 mm3; p = 0.366). However, the total surface area for femoral tunnels was larger in DB technique (919.65 +/- 201.79 mm2) compared to SB technique (810.02 +/- 117.98 mm2; p = 0.004). For tibia tunnels, there was a significant difference between tunnel volume for the SB technique (2,070.43 +/- 565.07 mm3) and the total tunnel volume for the DB technique (2,681.93 +/- 668.09 mm3; p < or = 0.001). The tibial tunnel surface area for the SB technique (958.84 +/- 147.50 mm2) was smaller than the total tunnel surface area for the DB technique (1,493.31 +/- 220.79 mm2; p < or = 0.001). CONCLUSIONS: Although the total femoral tunnel volume was similar between two techniques, the total surface area was larger in the DB technique. For the tibia, both total tunnel volume and the surface area were larger in DB technique.
Adult
;
Anterior Cruciate Ligament/injuries/surgery
;
Anterior Cruciate Ligament Reconstruction/*methods
;
Autografts
;
Femur/*radiography/surgery
;
Humans
;
Imaging, Three-Dimensional
;
Male
;
Tendon Injuries/*radiography/rehabilitation/surgery
;
Tendons/transplantation
;
Tibia/*radiography/surgery
9.Effect of Anteromedial Portal Entrance Drilling Angle during Anterior Cruciate Ligament Reconstruction: A Three-Dimensional Computer Simulation.
Dong Kyu MOON ; Chul Ho YOON ; Jin Seung PARK ; Bun Jung KANG ; Seong Hee CHO ; Ho Seung JO ; Sun Chul HWANG
Yonsei Medical Journal 2014;55(6):1584-1591
PURPOSE: The object of this study was to evaluate entrance angle effects on femoral tunnel length and cartilage damage during anteromedial portal drilling using three-dimensional computer simulation. MATERIALS AND METHODS: Data was obtained from an anatomic study performed using 16 cadaveric knees. The anterior cruciate ligament femoral insertion was dissected and the knees were scanned by computer tomography. Tunnels with different of three-dimensional entrance angles were identified using a computer simulation. The effects of different entrance angles on the femoral tunnel length and medial femoral cartilage damage were evaluated. Specifically, tunnel length and distance from the medial femoral condyle to a virtual cylinder of the femoral tunnel were measured. RESULTS: In tunnels drilled at a coronal angle of 45degrees, an axial angle of 45degrees, and a sagittal angle of 45degrees, the mean femoral tunnel length was 39.5+/-3.7 mm and the distance between the virtual cylinder of the femoral tunnel and the medial femoral condyle was 9.4+/-2.6 mm. The tunnel length at a coronal angle of 30degrees, an axial angle of 60degrees, and a sagittal angle of 45degrees, was 34.0+/-2.9 mm and the distance between the virtual cylinder of the tunnel and the medial femoral condyle was 0.7+/-1.3 mm, which was significantly shorter than the standard angle (p<0.001). CONCLUSION: Extremely low and high entrance angles in both of axial plane and coronal plane produced inappropriate tunnel angles, lengths and higher incidence of cartilage damage. We recommend that angles in proximity to standard angles be chosen during femoral tunnel drilling through the anteromedial portal.
Aged
;
Anterior Cruciate Ligament/*surgery
;
Anterior Cruciate Ligament Reconstruction/instrumentation/*methods
;
Cadaver
;
Computer Simulation
;
Female
;
Femur/anatomy & histology/*surgery
;
Humans
;
Imaging, Three-Dimensional
;
Knee Joint/radiography/*surgery
;
Male
;
Middle Aged
;
Osteotomy/*methods
;
Outcome and Process Assessment (Health Care)
;
Patient Positioning
;
Surgical Instruments
;
Tomography, X-Ray Computed
10.In Vivo Three-Dimensional Imaging Analysis of Femoral and Tibial Tunnel Locations in Single and Double Bundle Anterior Cruciate Ligament Reconstructions.
Jae Hyuk YANG ; Minho CHANG ; Dai Soon KWAK ; Ki Mo JANG ; Joon Ho WANG
Clinics in Orthopedic Surgery 2014;6(1):32-42
BACKGROUND: Anatomic footprint restoration of anterior cruciate ligament (ACL) is recommended during reconstruction surgery. The purpose of this study was to compare and analyze the femoral and tibial tunnel positions of transtibial single bundle (SB) and transportal double bundle (DB) ACL reconstruction using three-dimensional computed tomography (3D-CT). METHODS: In this study, 26 patients who underwent transtibial SB ACL reconstruction and 27 patients with transportal DB ACL reconstruction using hamstring autograft. 3D-CTs were taken within 1 week after the operation. The obtained digital images were then imported into the commercial package Geomagic Studio v10.0. The femoral tunnel positions were evaluated using the quadrant method. The mean, standard deviation, standard error, minimum, maximum, and 95% confidence interval values were determined for each measurement. RESULTS: The femoral tunnel for the SB technique was located 35.07% +/- 5.33% in depth and 16.62% +/- 4.99% in height. The anteromedial (AM) and posterolateral (PL) tunnel of DB technique was located 30.48% +/- 5.02% in depth, 17.12% +/- 5.84% in height and 34.76% +/- 5.87% in depth, 45.55% +/- 6.88% in height, respectively. The tibial tunnel with the SB technique was located 45.43% +/- 4.81% from the anterior margin and 47.62% +/- 2.51% from the medial tibial articular margin. The AM and PL tunnel of the DB technique was located 33.76% +/- 7.83% from the anterior margin, 45.56% +/- 2.71% from the medial tibial articular margin and 53.19% +/- 3.74% from the anterior margin, 46.00% +/- 2.48% from the medial tibial articular margin, respectively. The tibial tunnel position with the transtibial SB technique was located between the AM and PL tunnel positions formed with the transportal DB technique. CONCLUSIONS: Using the 3D-CT measuring method, the location of the tibia tunnel was between the AM and PL footprints, but the center of the femoral tunnel was at more shallow position from the AM bundle footprint when ACL reconstruction was performed by the transtibial SB technique.
Adult
;
Anterior Cruciate Ligament Reconstruction/*methods
;
*Femur/radiography/surgery
;
Humans
;
Imaging, Three-Dimensional/*methods
;
Knee Joint/physiology
;
Male
;
Prospective Studies
;
Surgery, Computer-Assisted/*methods
;
*Tibia/radiography/surgery
;
Tomography, X-Ray Computed

Result Analysis
Print
Save
E-mail