2.Application of 3D printing percutaneous guide plate in closed reduction and cannulated screw internal fixation of femoral neck fracture.
Qing-Ze WANG ; Ming-Xing LUO ; Shuai ZENG ; Jun-Guo BAO ; Wen-Li LUO ; Kai-Zong YUAN ; Li-Feng LAO
China Journal of Orthopaedics and Traumatology 2023;36(3):209-215
OBJECTIVE:
To investigate the application of 3D printing percutaneous surgical guide plate in closed reduction and cannulated screw internal fixation of femoral neck fracture.
METHODS:
The clinical data of 12 patients with femoral neck fracture from March 2019 to March 2022 were retrospectively analyzed. Patients were divided into observation group and control group according to different operation plans, with 6 cases in each group. The observation group received percutaneous operation guide plate assisted closed reduction and hollow screw internal fixation, while the control group received closed reduction and hollow compression screw internal fixation. The operation time, intraoperative blood loss, fluoroscopy times, and Kirschner needle puncture times were compared between two groups. The location of screws were recordedon postoperative X-ray films, follow-up time, time of complete fracture healing, Harris score of hip joint and the incidence of complications were recorded on postoperative X-ray films.
RESULTS:
The operation time of observation group (32.17±6.18) min was shorter than that of control group (53.83±7.31) min (P<0.05). The amount of intraoperative bleeding in the observation group (18.33±2.94) ml was less than that in the control group (38.17±5.56) ml(P<0.05). The times of fluoroscopy in the observation group (7.50±1.05) were less than those in the control group (21.00±4.82) (P<0.05). The number of Kirschner needle punctures (8.00±0.63) in observation group was less than that in control group (32.67±3.08) (P<0.05). The follow-up time was(12.88±0.74) months in observation group and (12.83±0.72) months in control group, there was no significant difference between two groups (P>0.05). One year after operation, Harris score of hip joint in the observation group was(82.00±4.52) points, while that in the control group was(81.00±3.41) points, there was no significant difference between two groups(P>0.05). The time of complete fracture healing in the observation group was (7.50±1.05) months, while that in the control group was (7.67±1.21) months, there was no significant difference between two groups(P>0.05). The parallelism of the screws in the observation group was (0.50±0.11) ° and (0.76±0.15) °, which were lower than that in the control group (1.57±0.31) ° and (1.87±0.21) ° (P<0.05). The screw distribution area ratio (0.13±0.02) cm2 in the observation group was higher than that in the control group (0.08±0.01) cm2 (P<0.05). No complications such as necrosis of femoral head, nonunion of fracture, shortening of femoral neck and withdrawal of internal fixation occurred in both groups.
CONCLUSION
The application of 3D printing percutaneous surgical guide plate improves the accuracy and safety of closed reduction and cannulated screw internal fixation for femoral neck fracture. It has the advantages of minimally invasive, reducing radiation exposure, fast and accurate, shortening the operation time and reducing intraoperative bleeding.
Humans
;
Retrospective Studies
;
Treatment Outcome
;
Femoral Neck Fractures/surgery*
;
Fracture Fixation, Internal
;
Bone Screws
;
Printing, Three-Dimensional
3.Disastrous triad of femoral head:femoral neck fracture meeting fracture-dislocation of femoral head.
China Journal of Orthopaedics and Traumatology 2023;36(3):216-221
Femoral head and ipsilateral femoral neck fractures are serious and complicated injuries, which usually yield unsatisfactory results using conventional hip-preserving surgery. The key point of the management and prognosis mainly lies in femoral neck fractures. An apparent and consecutive relationship exists between femoral neck fractures and femoral head fracture-hip dislocation in such injuries. It is believed that disastrous triad of femoral head (DTFH) could summarize these specific injuries, and reflect the injury mechanism and prognostic characteristics. Based on our clinical observation and literature review, DTFH could be divided into three subgroups:TypeⅠ, common DTFH, in which femoral neck fractures occur following femoral head fractures-hip dislocation due to the same trauma; TypeⅡ, iatrogenic DTFH, in which femoral neck fractures come out in the caring process of femoral head fractures-hip dislocation; Type Ⅲ, stressed DTFH, in which femoral neck fractures occur after the management of femoral head fractures-hip dislocation. In the scenario, the line of femoral neck fractures locates distally to the femoral head fractures. Herein, we will discuss clinical characteristics of these types of DTFH.
Humans
;
Femoral Fractures/complications*
;
Femoral Neck Fractures/complications*
;
Femur Head/injuries*
;
Fracture Dislocation
;
Fracture Fixation, Internal/methods*
;
Hip Dislocation/surgery*
;
Prognosis
4.Comparison of curative effect between Tianji robot assisted screw placement and traditional cannulated screw internal fixation for femoral neck fracture.
De-Xin NIE ; Wen-Gao SUN ; Xiao-Qiang WANG ; Ming-Jun WANG ; Jin-Bo SUN ; Chun CHEN
China Journal of Orthopaedics and Traumatology 2023;36(3):221-225
OBJECTIVE:
To investigate the clinical efficacy and advantages of Tianji orthopedic robot assisted cannulated screw internal fixation for femoral neck fracture.
METHODS:
The clinical data of 41 patients with femoral neck fracture who underwent internal fixation with cannulated screws from January 2019 to January 2022 were retrospectively analyzed. According to different surgical methods, they were divided into Tianji robot group and traditional cannulated screw fixation group (traditional operation group). Among them, there were 18 patients in Tianji robot group including 8 males and 10 females with age of (56.00±4.22) years old, Garden typeⅠ (4 cases), type Ⅱ (11 cases), type Ⅲ (2 cases), and type Ⅳ (1 case). There were 23 patients in the traditional operation group, including 10 males and 13 females, aged (54.87±4.81) years old;there were 5 cases of Garden typeⅠ, 14 cases of type Ⅱ, 3 cases of type Ⅲ and 1 case of type Ⅳ. The operation time, intraoperative blood loss, fluoroscopy times, guide needle placement times, operation costs and other indicators were observed and compared between two groups. Harris score was used to evaluate hip joint function 12 months after operation.
RESULTS:
The wounds of all patients healed in Grade A without complications. There were significant differences between two groups in terms of operation time, times of intraoperative fluoroscopy, times of guide needle placement, amount of intraoperative bleeding, and operation cost (P<0.05). All 41 patients were followed up for at least 12 months. The fractures of both groups were healed. There was no infection, screw loosening, fracture displacement and femoral head necrosis in Tianji robot group during follow-up;Screw loosening occurred in 2 patients in the traditional operation group during follow-up. At 12 months after operation, Harris hip joint function score of Tianji robot group was higher than that of traditional operation group in daily activity, lameness, joint activity score and total score (P<0.05).
CONCLUSION
Tianji robot assisted nail placement is a better method for the treatment of femoral neck fracture, which improves the surgical efficiency, is more accurate, has higher success rate of one-time nail placement, shorter operation time, less radiation, and has better hip joint function recovery after surgery.
Male
;
Female
;
Humans
;
Middle Aged
;
Robotics
;
Retrospective Studies
;
Femoral Neck Fractures/surgery*
;
Bone Screws
;
Fracture Fixation, Internal/methods*
;
Treatment Outcome
5.Comparison of curative effect between percutaneous compression plate and cannulated compression screw in the treatment of displaced femoral neck fractures in young and middle-aged patients.
Xue-Liang CUI ; He LI ; Liu SHI ; Wen-Jun XIE ; Hui CHEN
China Journal of Orthopaedics and Traumatology 2023;36(3):226-231
OBJECTIVE:
To compare the efficacy of percutaneous compression plate and cannulated compression screw in the treatment of displaced femoral neck fractures in young and middle-aged patients.
METHODS:
From January 2015 to July 2020, 68 young and middle-aged patients with displaced femoral neck fracture were retrospectively analyzed. Among them, 31 cases were fixed by percutaneous compression plate (PCCP), and 37 cases were fixed by cannulated compression screw (CCS). General data such as gender, age, cause of injury, comorbidities, fracture classification and cause of injury of two groups were collected. The operation time, intraoperative blood loss, hospital stay, full weight bearing time, fracture healing time, visual analogue scale(VAS), Harris hip score and complications were compared between two groups.
RESULTS:
Patients in both groups were followed up for more than 2 years. There were no significant differences in operation time, intraoperative blood loss, fracture reduction quality, hospital stay and VAS between two groups. The fracture healing time in PCCP group was significantly shorter than that in CCS group (t=-4.404, P=0.000). The complete weight bearing time of PCCP group was significantly shorter than that of CCS group (t=-9.011, P=0.000). Harris score of hip joint in PCCP group was better than that in CCS group 2 years after operation (P=0.002). Complications occurred in 3 cases (9.68%) in PCCP group, while 11 cases (29.72%) in CCS group, with a statistically significant difference (P=0.042).
CONCLUSION
Both PCCP and CCS can be used for the treatment of displaced femoral neck fractures in young and middle-aged people. Compared with CCS, PCCP fixation can achieve shorter fracture healing time and create conditions for early full weight bearing. PCCP results in higher hip score and lower complications.
Middle Aged
;
Humans
;
Treatment Outcome
;
Blood Loss, Surgical
;
Retrospective Studies
;
Fracture Fixation, Internal/methods*
;
Femoral Neck Fractures/surgery*
;
Bone Screws
6.Comparison of effect between internal fixation and total hip replacement in the treatment of displaced femoral neck fracture in middle age patients.
Zhi-Yuan WANG ; Fan LUO ; Ying-Qi ZHANG ; Jia LIU ; Xiao-Zhong ZHU ; Zhi-Tao RAO
China Journal of Orthopaedics and Traumatology 2023;36(3):232-235
OBJECTIVE:
To analyze and compare the clinical efficacy of internal fixation and total hip replacement in the treatment of displaced femoral neck fracture from 55 to 65 years.
METHODS:
From September 2016 to August 2020, 86 patients with Garden type Ⅲ or Ⅳ femoral neck fracture were divided into two groups according to different surgical methods. Among them, 38 patients were treated with lag screws for internal fixation, there were 26 males and 12 females, aged 55 to 64 years old with an average of(60.2±3.1) years;the other 48 patients were treated with total hip replacement, including 28 males and 20 females, aged from 57 to 65 years old with an average of(61.3±3.8) years. The time from injury to operation ranged from 1 to 3 days. The reoperation rate, incidence of deep infection, Harris score of hip joint function, visual analogue scale(VAS) of pain and patients reported outcome scores(European five-dimensional Health Questionnaire, EQ-5D) were compared between two groups.
RESULTS:
All patients were followed up for 24 to 54 months with an average of (35.8±10.3) months. There was significant difference in reoperation rate between two groups (P<0.05). There was no significant difference on the incidence of deep infection, hip Harris score and VAS between two groups(P>0.05) . The postoperative EQ-5D score of patients with internal fixation was lower than that of total hip replacement, and the difference was statistically significant(P<0.05).
CONCLUSION
Both the surgery of internal fixation and total hip replacement have similar effect in short-and medium term among the patients aged 55 to 65 years old. However, for the reoperation rate, the group of internal fixation was higher than that of total hip replacement. For the subjective functional score of patients, the group of internal fixation was lower than that of total hip replacement.
Male
;
Female
;
Humans
;
Middle Aged
;
Aged
;
Arthroplasty, Replacement, Hip/methods*
;
Treatment Outcome
;
Femoral Neck Fractures/surgery*
;
Fracture Fixation, Internal/methods*
;
Reoperation
7.Biomechanical characteristics of retinaculum in the treatment of femoral neck fractures.
China Journal of Orthopaedics and Traumatology 2023;36(3):251-255
OBJECTIVE:
To investigate the biomechanical characteristics of retinaculum in the treatment of femoral neck fractures.
METHODS:
The CT data of a 75-year-old female volunteer was processed by software to construct an intact femur model and femoral neck fracture model fixed with three cannulated screws, which were divided into models with retinaculum or not. The Von-Mises stress distribution and displacement were compared to analyze the stability differences between the different models to study the mechanical characteristics of the retinaculum in the treatment of femoral neck fractures.
RESULTS:
In the intact femur, the most obvious displacement appeared in the weight-bearing area of the femoral head, with retinaculum 0.381 37 mm, and without retinaculum 0.381 68 mm. The most concentrated part of the Von-Mises stress distribution was located in the medial and inferior part of the femoral neck, with retinaculum 11.80 MPa, without retinaculum 11.91 MPa. In the femoral neck fracture fixed with three cannulated screws model, the most obvious position of displacement also appeared in the weight-bearing area of the femoral head, with retinaculum 0.457 27 mm, without retinaculum 0.458 63 mm. The most concentrated part of the Von-Mises located at the medical and inferior part of the femoral neck, with retinaculum 59.22 MPa, without retinaculum 59.14 MPa. For the cannulated screws, the Von-Mises force peaks all appeared in the posterior and superior screw, with retinaculum 107.48 MPa, without retinaculum 110.84 MPa. Among the three screws, the Von-Mises stress of the anterior-superior screw was the smallest, which was 67.88 MPa vs 68.76 MPa in the retinaculum and non-retinaculum groups, respectively.
CONCLUSION
The complete retinaculum has little effect on the stability of intact femur and femoral neck fractures with anatomical reduction after internal fixation, and cannot effectively improve the stability of the fracture end after the fracture.
Female
;
Humans
;
Aged
;
Finite Element Analysis
;
Femoral Neck Fractures/surgery*
;
Fracture Fixation, Internal
;
Bone Screws
;
Femur Neck
;
Biomechanical Phenomena
8.Biomechanical analysis of four internal fixations for Pauwels Ⅲ femoral neck fractures with defects.
Zhi-Hao SU ; Hong-Li TAN ; Zi-Huan XU ; Peng-Fei LI ; Yong-Qin WANG ; Shuang LI ; Ming NI
China Journal of Orthopaedics and Traumatology 2023;36(3):255-261
OBJECTIVE:
To investigate the biomechanical characteristics of different internal fixations for Pauwels type Ⅲ femoral neck fracture with defect, and provide reference for the treatment of femoral neck fracture.
METHODS:
Three-dimensional (3D) finite element models of femoral neck fractures were established based on CT images, including fracture and fracture with defects. Four internal fixations were simulated, namely, inverted cannulated screw(ICS), ICS combined with medial buttress plate, the femoral neck system (FNS) and FNS combined with medial buttress plate. The von Mises stress, model stiffness and fracture displacements of fracture models under 2 100 N axial loads were measured and compared.
RESULTS:
When femoral neck fracture was fixed by ICS and FNS, the peak stress was mainly concentrated on the surface of the screw near the fracture line, and the peak stress of FNS is higher than that of ICS;When the medial buttress plate was combined, the peak stress was increased and transferred to medial buttress plate, with more obvious of ICS fixation. For the same fracture model, the stiffness of FNS was higher than that of ICS. Compared with femoral neck fracture with defects, fracture model showed higher stiffness in the same internal fixation. The use of medial buttress plate increased model stiffness, but ICS increased more than FNS. The fracture displacement of ICS model exceeded that of FNS.
CONCLUSION
For Pauwels type Ⅲ femoral neck fracture with defects, FNS had better biomechanical properties than ICS. ICS combined with medial buttress plate can better enhance fixation stability and non-locking plate is recommended. FNS had the capability of shear resistance and needn't combine with medial buttress plate.
Humans
;
Femoral Neck Fractures/surgery*
;
Fracture Fixation, Internal/methods*
;
Bone Screws
;
Bone Plates
;
Biomechanical Phenomena
;
Finite Element Analysis
9.Review of closed reduction techniques for femoral neck fracture.
Xiao-Zhong ZHU ; Yi ZHU ; Jiong MEI
China Journal of Orthopaedics and Traumatology 2023;36(3):273-278
For patients with femoral neck fractures who plan to undergo internal fixation, satisfied alignment of fracture ends is an important prerequisite for internal fixation stability and fracture healing. There are many reports on the reduction methods of displaced femoral neck fractures, which can be summarized into three categories:First, the solely longitudinal traction of lower limbs, supplemented by other manipulations such as rotation and compression; Second, the resultant force formed by the longitudinal traction of lower limbs and the lateral traction;the third is accomplished by vertical traction in the axis of femur with hip joint flexed. Each reduction method has its own advantages, but no single method can be applied to all fracture displacement. In this paper, some classical reduction techniques in the literatures are briefly reviewed. It is hoped that clinicians will not be limited to a certain reduction method, they should analyze the injury mechanism and fracture displacement process according to the morphology features and flexibly select targeted reduction methods to improve the success rate of closed reduction of femoral neck fracture.
Humans
;
Femoral Neck Fractures/surgery*
;
Femur
;
Fracture Fixation, Internal
;
Fracture Healing
;
Traction
;
Treatment Outcome
10.Interpretations of Management of Hip Fractures in Older Adults:Evidence-Based Clinical Practice Guideline dopted by AAOS 2021.
China Journal of Orthopaedics and Traumatology 2023;36(3):279-283
American Academy of Orthopaedic Surgeons (AAOS) just released the up-to-date
Aged
;
Humans
;
Arthroplasty, Replacement, Hip
;
Femoral Neck Fractures/surgery*
;
Fracture Fixation, Internal
;
Hip Fractures/surgery*
;
Orthopedic Surgeons
;
Treatment Outcome
;
United States
;
Practice Guidelines as Topic

Result Analysis
Print
Save
E-mail