1.Single Kocher-Langenbeck approach combined with anterograde channel screw technique in treatment of acetabular transverse and posterior wall fractures.
Xuepeng XU ; Jinhui LIU ; Lincong FEI ; Junwu YE
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):35-39
OBJECTIVE:
To assess the effectiveness of the single Kocher-Langenbeck approach combined with anterograde channel screw technique for the treatment of acetabular transverse and posterior wall fractures.
METHODS:
Between March 2020 and October 2022, 17 cases of acetabular transverse and posterior wall fractures were treated with the single Kocher-Langenbeck approach combined with anterograde channel screw technique. There were 11 males and 6 females, with an average age of 53.6 years (range, 42-64 years). Causes of injury included traffic accident in 12 cases, and falling from height in 5 cases. The time from injury to operation ranged from 4 to 16 days with an average of 8.8 days. The operation time, intraoperative blood loss, and fluoroscopy frequency were recorded; X-ray films were reviewed regularly after operation to observe the fracture healing, and postoperative complications were recorded. At last follow-up, Matta score was used to evaluate the reduction of fracture, Harris score and modified Merle D'Aubigné-Postel scores system were used to evaluate the hip joint function.
RESULTS:
The operation time was 150-230 minutes (mean, 185.9 minutes), the intraoperative blood loss was 385-520 mL (mean, 446.2 mL), and the fluoroscopy frequency was 18-34 times (mean, 27.5 times). Postoperative fat liquefaction occurred in 1 case and the other incisions healed by first intention; 3 cases had limb numbness after operation, and the symptoms disappeared after active symptomatic treatment; no urogenital system and intestinal injury occurred. All patients were followed up 12-28 months (mean, 19.9 months). Bone union was achieved in all cases with an average healing time of 10.8 weeks (range, 8-14 weeks). There was no complication such as loosening and breakage of internal fixators. At last follow-up, according to Matta score, 12 cases achieved anatomic reduction, 3 satisfactory reduction, and 2 fair reduction, the satisfactory rate was 88.2%; according to Harris hip function score, 12 cases were excellent, 3 good, and 2 fair, the excellent and good rate was 88.2%; according to the modified Merle D'Aubign Aubigné-Postel scoring system, the results were excellent in 11 cases, good in 3 cases, and fair in 3 cases, with an excellent and good rate of 82.4%.
CONCLUSION
The single Kocher-Langenbeck approach combined with anterograde channel screw technique is a minimally invasive method for the treatment of acetabular transverse and posterior wall fractures with less complications, simple operation, and satisfactory effectiveness.
Male
;
Female
;
Humans
;
Middle Aged
;
Blood Loss, Surgical
;
Fracture Fixation, Internal/methods*
;
Treatment Outcome
;
Fractures, Bone/surgery*
;
Acetabulum/injuries*
;
Bone Screws
;
Hip Fractures/surgery*
;
Retrospective Studies
2.Early mobilisation following fragility hip fracture surgery: current trends and association with discharge outcomes in a local tertiary hospital.
Shumei TAN ; Aswinkumar VASIREDDY
Singapore medical journal 2023;64(12):721-727
INTRODUCTION:
Postoperative day 1 (POD 1) mobilisation is a key clinical indicator for the fragility hip fracture surgery population. This study aimed to evaluate the current trends of POD 1 mobilisation at our institution and to review the relationships between early mobilisation and outcomes of early functional recovery, length of stay (LOS) and discharge destination.
METHODS:
In this preliminary observational study, data pertaining to demographics, premorbid function, health status, injury and surgical factors, POD 1 mobilisation status and clinical outcomes of interest were retrieved from eligible patients. Patients who attained POD 1 ambulation formed the early ambulation (EA) group, while the remaining patients formed the delayed ambulation (DA) group. Data were analysed for any significant difference between the groups.
RESULTS:
One hundred and fifteen patients were included in the analysis. The rate of patients achieving at least sitting out of bed on POD 1 was 80.0% (n=92), which was comparable to the data available from international hip fracture audit databases. There were 55 (47.8%) patients in the EA group and 60 (52.5%) patients in the DA group. The EA group was approximately nine times more likely to achieve independence in ambulation at discharge compared to the DA group (adjusted odds ratio 9.20, 95% confidence interval 1.50-56.45; P = 0.016). There were observed trends of shorter LOS and more proportion of home discharge in the EA group compared to the DA group (P > 0.05).
CONCLUSION
This is the first local study to offer benchmark of the POD 1 mobilisation status for this population. Patients who attained POD 1 ambulation had better early functional recovery.
Humans
;
Early Ambulation
;
Patient Discharge
;
Tertiary Care Centers
;
Hip Fractures/surgery*
;
Physical Therapy Modalities
;
Length of Stay
5.Study on effectiveness of treating femoral neck fractures based on theory of "positive support".
Liu YANG ; Gang MO ; Lin XU ; Yang LI ; Shiqiang RUAN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(8):958-963
OBJECTIVE:
To explore effectiveness of positive support reduction and internal fixation in the treatment of femoral neck fractures.
METHODS:
A clinical data of 74 patients with femoral neck fractures treated with hollow screw internal fixation between September 2017 and September 2021 was retrospectively analyzed. Based on the quality of fracture reduction, they were divided into positive support reduction group (group A, n=25), negative support reduction group (group B, n=21), and anatomical reduction group (group C, n=28). There was no significant difference in baseline data such as gender, age, cause of injury, disease duration, fracture side, Garden classification, and fracture line position classification between groups (P>0.05). The occurrence of complications such as early fixation failure, femoral neck shortening, non-union of fractures, and femoral head necrosis in three groups, as well as the Harris score of the hip joint were recorded and compared.
RESULTS:
All patients had primary healing of incisions after operation and were followed up more than 12 months. The follow-up time for groups A, B, and C was (21.1±5.7), (22.6±4.3), and (21.9±4.1) months, respectively; there was no significant difference between groups (P>0.05). There was no significant difference in the incidences of non-union of fractures, early internal fixation failure, and the femoral head necrosis between groups (P>0.05). The incidence and length of femoral neck shortening, and the hip Harris score at last follow-up in groups A and C were all superior to those in the group B, with significant difference (P<0.05). There was no significant difference in the above indicators between groups A and C (P>0.05).
CONCLUSION
Positive support reduction can provide a good biomechanical environment for the healing of femoral neck fractures, thereby achieving a higher fracture healing rate, reducing the occurrence of femoral neck shortening, minimizing the function of hip joint, and achieving effectiveness similar to anatomical reduction.
Humans
;
Femur Head Necrosis
;
Retrospective Studies
;
Femoral Neck Fractures/surgery*
;
Femur Neck
;
Plastic Surgery Procedures
6.Research progress on evaluation methods for head-neck nail position in femoral intertrochanteric fractures.
Lincong FEI ; Xuzhou ZHENG ; Xuepeng XU ; Junwu YE
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(9):1149-1155
OBJECTIVE:
To summarize the research progress on the evaluation methods of head-neck nail positions in femoral intertrochanteric fractures.
METHODS:
The literature about the evaluation methods of head-neck nail positions for femoral intertrochanteric fractures in recent years was extensively reviewed, and research progress in the aspects of evaluation methods, clinical applications, and limitations were summarized.
RESULTS:
The position of head-neck nails in femoral intertrochanteric fractures is closely related to postoperative complications of head-neck nail cutting. Currently, the tip-apex distance (TAD) and femoral head zoning are widely used to evaluate the position of head-neck nails. The main opinion in the literature is that the use of TAD and femoral head zoning can effectively reduce the incidence of head-neck nails cutting. Parker's ratio, as one of the evaluation methods, has been controversial in subsequent studies and has not been widely used in clinical practice. The TAD as referenced to the calcar (CalTAD), which was modified based on TAD, has been gradually accepted by the clinic, but whether it is better than the TAD has not yet been conclusively determined. In recent years, new evaluation methods have been proposed to supplement the previous evaluation methods, such as the tip-neck distance ratio (TNDR) and the standardized TAD (STAD) to avoid the limitations of the TAD and the CalTAD by the volume of the femoral head, and the axis-blade angle (ABA) to supplement the direction of the head-neck nails channel, but at present the clinical application is relatively underutilized, and the validity of the method needs to be further verified.
CONCLUSION
Currently, there are many methods for evaluating the position of head-neck nails in femoral intertrochanteric fractures, TAD<25 mm combined with head-neck nails placed in the middle-middle quadrant or lower-middle quadrant of the femoral head division is currently a highly recognized assessment in the literature, but the optimal assessment is still controversial, and further research needs to be studied.
Humans
;
Nails
;
Head
;
Neck
;
Femoral Fractures
;
Hip Fractures/surgery*
7.Three-dimensional-printed hemi-pelvic prosthesis for revision of aseptic loosening or screw fracture of modular hemi-pelvic prosthesis.
Xin LIU ; Yi LUO ; Xuanhong HE ; Jie WANG ; Zhuangzhuang LI ; Yuqi ZHANG ; Xin HU ; Minxun LU ; Fan TANG ; Yong ZHOU ; Li MIN ; Chongqi TU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1183-1189
OBJECTIVE:
To investigate the effectiveness of three-dimensional (3D)-printed hemi-pelvic prosthesis for revision of aseptic loosening or screw fracture of modular hemi-pelvic prosthesis.
METHODS:
Between February 2017 and January 2020, 11 patients with aseptic loosening or screw fracture of modular hemi-pelvic prosthesis were revised using 3D-printed hemi-pelvic prostheses. There were 7 males and 4 females with an average age of 44 years (range, 25-60 years). In the first operation, all patients underwent total tumor resection, modular hemi-pelvic prosthesis reconstruction, and autologous femoral head transplantation. According to the Enneking pelvic partition system, 8 cases were resected in zones Ⅰ+Ⅱ and 3 cases in zones Ⅰ+Ⅱ+Ⅲ. The interval from the initial operation to this revision ranged from 14.3-66.2 months, with an average of 35.8 months. The operation time, the amount of intraoperative bleeding, and the occurrence of complications were recorded. At 6 months after the first operation, before revision, and at last follow-up, the American Musculoskeletal Tumor Society (MSTS) score and Harris score were used to evaluate the recovery of lower limb function. The pain-free walking distance of patients without brace assistance was recorded at last follow-up. X-ray films were taken at 1 month after the first operation, before revision, and at 1 month after revision, the acetabulum position was assessed by the differences in weight arm and cup height between bilateral hip joints. At last follow-up, the digital X-ray tomography was taken to evaluate the prosthesis-bone integration and the occurrence of aseptic loosening.
RESULTS:
The operation time was 182.6-238.0 minutes (mean, 197.4 minutes). The amount of intraoperative bleeding was 400-860 mL (mean, 550.0 mL). All incisions healed by first intention with no infection, hip dislocation, nerve damage, or vascular-related adverse events. The MSTS score and Harris score at last follow-up were significantly higher than those at 6 months after the first operation and before revision ( P<0.05), while the score before revision was significantly lower than that at 6 months after the first operation ( P<0.05). At last follow-up, the patients were able to walk more than 1 000 meters painlessly without brace assistance. Imaging review showed that the difference of cup height at 1 month after revision was significantly lower than that at 1 month after the first operation and before revision, and at 1 month after the first operation than before revision operation, and the differences were significant ( P<0.05). There was no significant difference in the difference of weight arm among three time points ( P>0.05). All prostheses were well integrated, and no aseptic loosening of the prosthesis or screw fracture occurred.
CONCLUSION
Revision with 3D-printed hemi-pelvic prostheses benefited in reconstructing stable pelvic ring and natural bodyweight transmission for patients encountering the aseptic loosening or screw fracture of modular hemi-pelvic prosthesis. Early postoperative rehabilitation training can maximize the recovery of patient limb function, reduce pain during walking, and reduce the incidence of complications.
Male
;
Female
;
Humans
;
Adult
;
Arthroplasty, Replacement, Hip/methods*
;
Hip Prosthesis
;
Treatment Outcome
;
Prosthesis Failure
;
Fractures, Bone/surgery*
;
Retrospective Studies
;
Neoplasms
8.Effectiveness of proximal femur bionic nail for intertrochanteric fracture in the elderly.
Dongsong YANG ; Qiong WANG ; Zhonghao LUAN ; Jiansheng LING ; Peng CHEN ; Xudong CHEN ; Dongtao YUAN ; Xiangzhou ZHEN ; Junqiang WANG
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1198-1204
OBJECTIVE:
To evaluate effectiveness of proximal femur bionic nail (PFBN) in treatment of intertrochanteric fractures in the elderly compared to the proximal femoral nail antirotation (PFNA).
METHODS:
A retrospective analysis was made on 48 geriatric patients with intertrochanteric fractures, who met the selection criteria and were admitted between January 2020 and December 2022. Among them, 24 cases were treated with PFBN fixation after fracture reduction (PFBN group), and 24 cases were treated with PFNA fixation (PFNA group). There was no significant difference in baseline data such as age, gender, cause of injury, side and type of fracture, time from injury to operation, and preoperative mobility score, American Society of Anesthesiologists (ASA) score, Alzheimer's disease degree scoring, self-care ability score, osteoporosis degree (T value), and combined medical diseases between the two groups ( P>0.05). The operation time, intraoperative blood loss, number of blood transfusions, transfusion volume, length of hospital stay, occurrence of complications, weight-bearing time after operation, and postoperative visual analogue scale (VAS) score, walking ability score, mobility score, self-care ability score were recorded and compared between the two groups. And the radiographic assessment of fracture reduction quality and postoperative stability, and fracture healing time were recorded.
RESULTS:
The operations in both groups were successfully completed. All patients were followed up 6-15 months with an average time of 9.8 months in PFBN group and 9.6 months in PFNA group. The operation time was significantly longer in PFBN group than in PFNA group ( P<0.05), but there was no significant difference in intraoperative blood loss, number of blood transfusions, transfusion volume, length of hospital stay, change in activity ability score, and change in self-care ability score between the two groups ( P>0.05). The weight-bearing time after operation was significantly shorter in PFBN group than in PFNA group ( P<0.05), and the postoperative VAS score and walking ability score were significantly better in PFBN group than in PFNA group ( P<0.05). Radiographic assessment showed no significant difference in fracture reduction scores and postoperative stability scores between the two groups ( P>0.05). All fractures healed and there was no significant difference in fracture healing time between the two groups ( P>0.05). The incidence of complications was significantly lower in PFBN group (16.7%, 4/24) than in PFNA group (45.8%, 11/24) ( P<0.05).
CONCLUSION
Compared with PFNA, PFBN in the treatment of elderly intertrochanteric fractures can effectively relieve postoperative pain, shorten bed time, reduce the risk of complications, and facilitate the recovery of patients' hip joint function and walking ability.
Humans
;
Aged
;
Retrospective Studies
;
Fracture Fixation, Intramedullary
;
Bionics
;
Blood Loss, Surgical
;
Treatment Outcome
;
Bone Nails
;
Hip Fractures/surgery*
;
Femur
9.Comparison of effectiveness of lower extremity axial distractor and traction table assisted closed reduction and intramedullary nail fixation in femoral subtrochanteric fracture.
Xingkai ZHANG ; Nan ZHOU ; Mingliang MA ; Gangqiang DU ; Zeyue GENG ; Ruifeng QI ; Zhigang WANG
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(12):1465-1470
OBJECTIVE:
To compare the effectiveness of lower extremity axial distractor (LEAD) and traction table assisted closed reduction and intramedullary nail fixation in treatment of femoral subtrochanteric fracture.
METHODS:
The clinical data of 117 patients with subtrochanteric fracture of femur treated by closed reduction and intramedullary nail fixation between May 2012 and May 2022 who met the selection criteria were retrospectively analyzed. According to the auxiliary reduction tools used during operation, the patients were divided into LEAD group (62 cases with LEAD reduction) and traction table group (55 cases with traction table reduction). There was no significant difference in baseline data, such as gender, age, injured side, cause of injury, fracture Seinsheimer classification, time from injury to operation, and preoperative visual analogue scale (VAS) score, between the two groups ( P>0.05). Total incision length, operation time, intraoperative blood loss, fluoroscopy frequency, closed reduction rate, fracture reduction quality, fracture healing time, weight-bearing activity time, and incidence of complications, as well as hip flexion and extension range of motion (ROM), Harris score, and VAS score at 1 month and 6 months after operation and last follow-up were recorded and compared between the two groups.
RESULTS:
There were 14 cases in the LEAD group from closed reduction to limited open reduction, and 43 cases in the traction table group. The incisions in the LEAD group healed by first intention, and no complication such as nerve and vascular injury occurred during operation. In the traction table group, 3 cases had perineal crush injury, which recovered spontaneously in 1 week. The total incision length, operation time, intraoperative blood loss, fluoroscopy frequency, and closed reduction rate in the LEAD group were significantly better than those in the traction table group ( P<0.05). There was no significant difference in the quality of fracture reduction between the two groups ( P>0.05). Patients in both groups were followed up 12-44 months, with an average of 15.8 months. In the LEAD group, 1 patient had delayed fracture union at 6 months after operation, 1 patient had nonunion at 3 years after operation, and 1 patient had incision sinus pus flow at 10 months after operation. In the traction table group, there was 1 patient with fracture nonunion at 15 months after operation. X-ray films of the other patients in the two groups showed that the internal fixator was fixed firmly without loosening and the fractures healed. There was no significant difference in fracture healing time, weight bearing activity time, incidence of complications, and postoperative hip flexion and extension ROM, Harris score, and VAS score at different time points between the two groups ( P>0.05).
CONCLUSION
For femoral subtrochanteric fracture treated by close reduction and intramedullary nail fixation, compared with traction table, LEAD assisted fracture reduction can significantly shorten the operation time, reduce intraoperative blood loss and fluoroscopy frequency, reduce incision length, effectively improve the success rate of closed reduction, and avoid complications related to traction table reduction. It provides a new method for good reduction of femoral subtrochanteric fracture.
Humans
;
Fracture Fixation, Intramedullary
;
Bone Nails
;
Traction
;
Blood Loss, Surgical/prevention & control*
;
Retrospective Studies
;
Treatment Outcome
;
Femoral Fractures
;
Hip Fractures/surgery*
;
Lower Extremity
;
Surgical Wound
;
Fracture Fixation, Internal
10.Early effectiveness of Ti-Robot assisted femoral neck system for minimally invasive treatment of elderly Garden type Ⅱ and Ⅲ femoral neck fractures.
Yajun LIU ; Zhaodong WANG ; Chen XU ; Zhonglian ZHU ; Keyou DUAN ; Jianzhong GUAN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(12):1471-1476
OBJECTIVE:
To investigate the early effectiveness of the Ti-Robot assisted femoral neck system (FNS) in the treatment of elderly Garden type Ⅱ and Ⅲ femoral neck fractures.
METHODS:
A retrospective analysis was conducted on the clinical data of 41 elderly patients with Garden type Ⅱ and Ⅲ femoral neck fractures who were admitted between December 2019 and August 2022 and met the selection criteria. Among them, 21 cases were treated with Ti-Robot assisted FNS internal fixation (study group), and 20 cases were treated solely with FNS internal fixation (control group). There was no significant difference in baseline data, including gender, age, side, cause of injury, time from injury to surgery, fracture Garden classification, and fracture line classification, between the two groups ( P>0.05). Surgical effectiveness was evaluated based on parameters such as operation time (including incision time and total operation time), reduction level, number of dominant pin insertions, intraoperative fluoroscopy frequency, incision length, whether to extend the incision, need for assisted reduction, postoperative hospital stay, fracture healing time, incidence of osteonecrosis of the femoral head, postoperative visual analogue scale (VAS) score at 1 day, and Harris hip score at last follow-up.
RESULTS:
The study group showed significantly shorter incision time, fewer dominant pin insertions, fewer instances of extended incisions, fewer intraoperative fluoroscopy frequency, and smaller incisions than the control group ( P<0.05). There was no significant difference in total operation time, reduction level, and assisted reduction frequency between the two groups ( P>0.05). Both groups achieved primary wound healing postoperatively, with no complications such as incision leakage or skin infection. All patients were followed up 12-24 months with an average of 14.6 months. Fractures healed in both groups, with no significant difference in healing time ( P>0.05). There was no significant difference in postoperative hospital stay between the two groups ( P>0.05). The study group showed significantly better VAS score at 1 day after operation and Harris hip score at last follow-up when compared to the control group ( P<0.05). No complication such as internal fixation failure, fracture displacement, or hip joint varus occurred in both groups during the follow-up. Osteonecrosis of the femoral head occurred in 1 patient of the control group, while no was observed in the study group, and the difference in the incidence of osteonecrosis of the femoral head between the two groups was not significant ( P=0.488).
CONCLUSION
Compared to sole FNS internal fixation treatment, Ti-Robot assisted FNS internal fixation for elderly Garden typeⅡ and Ⅲ femoral neck fractures can reduce incision time, achieve minimally invasive and accurate nail implantation, and decrease intraoperative fluoroscopy frequency, leading to improved postoperative hip joint function recovery.
Humans
;
Aged
;
Femur Neck
;
Robotics
;
Retrospective Studies
;
Treatment Outcome
;
Titanium
;
Femoral Neck Fractures/surgery*
;
Fracture Fixation, Internal
;
Osteonecrosis
;
Surgical Wound

Result Analysis
Print
Save
E-mail