1.Long-Term Incidence of Gastrointestinal Bleeding Following Ischemic Stroke
Jun Yup KIM ; Beom Joon KIM ; Jihoon KANG ; Do Yeon KIM ; Moon-Ku HAN ; Seong-Eun KIM ; Heeyoung LEE ; Jong-Moo PARK ; Kyusik KANG ; Soo Joo LEE ; Jae Guk KIM ; Jae-Kwan CHA ; Dae-Hyun KIM ; Tai Hwan PARK ; Kyungbok LEE ; Hong-Kyun PARK ; Yong-Jin CHO ; Keun-Sik HONG ; Kang-Ho CHOI ; Joon-Tae KIM ; Dong-Eog KIM ; Jay Chol CHOI ; Mi-Sun OH ; Kyung-Ho YU ; Byung-Chul LEE ; Kwang-Yeol PARK ; Ji Sung LEE ; Sujung JANG ; Jae Eun CHAE ; Juneyoung LEE ; Min-Surk KYE ; Philip B. GORELICK ; Hee-Joon BAE ;
Journal of Stroke 2025;27(1):102-112
Background:
and Purpose Previous research on patients with acute ischemic stroke (AIS) has shown a 0.5% incidence of major gastrointestinal bleeding (GIB) requiring blood transfusion during hospitalization. The existing literature has insufficiently explored the long-term incidence in this population despite the decremental impact of GIB on stroke outcomes.
Methods:
We analyzed the data from a cohort of patients with AIS admitted to 14 hospitals as part of a nationwide multicenter prospective stroke registry between 2011 and 2013. These patients were followed up for up to 6 years. The occurrence of major GIB events, defined as GIB necessitating at least two units of blood transfusion, was tracked using the National Health Insurance Service claims data.
Results:
Among 10,818 patients with AIS (male, 59%; mean age, 68±13 years), 947 (8.8%) experienced 1,224 episodes of major GIB over a median follow-up duration of 3.1 years. Remarkably, 20% of 947 patients experienced multiple episodes of major GIB. The incidence peaked in the first month after AIS, reaching 19.2 per 100 person-years, and gradually decreased to approximately one-sixth of this rate by the 2nd year with subsequent stabilization. Multivariable analysis identified the following predictors of major GIB: anemia, estimated glomerular filtration rate <60 mL/min/1.73 m2 , and a 3-month modified Rankin Scale score of ≥4.
Conclusion
Patients with AIS are susceptible to major GIB, particularly in the first month after the onset of AIS, with the risk decreasing thereafter. Implementing preventive strategies may be important, especially for patients with anemia and impaired renal function at stroke onset and those with a disabling stroke.
2.Erratum: Correction of Text in the Article “The Long-term Outcomes and Risk Factors of Complications After Fontan Surgery: From the Korean Fontan Registry (KFR)”
Sang-Yun LEE ; Soo-Jin KIM ; Chang-Ha LEE ; Chun Soo PARK ; Eun Seok CHOI ; Hoon KO ; Hyo Soon AN ; I Seok KANG ; Ja Kyoung YOON ; Jae Suk BAEK ; Jae Young LEE ; Jinyoung SONG ; Joowon LEE ; June HUH ; Kyung-Jin AHN ; Se Yong JUNG ; Seul Gi CHA ; Yeo Hyang KIM ; Youngseok LEE ; Sanghoon CHO
Korean Circulation Journal 2025;55(3):256-257
3.Testing the reliability and validity of the Korean version of the Pittsburgh Sleep Quality Index using Fitbit devices: a cross-sectional analysis
Si-Yeon LEE ; Ja-Eun CHOI ; Ji-Won LEE ; Yaeji LEE ; Jae-Min PARK ; Kyung-Won HONG
Korean Journal of Family Medicine 2025;46(1):42-47
Background:
Sleep disorders and insomnia are prevalent worldwide, with negative health outcomes. The Pittsburgh Sleep Quality Index (PSQI) is a widely used self-report assessment tool for evaluating sleep quality, comprising seven subdomains. The Korean version of the PSQI (PSQI-K) has been tested for reliability and validity in small sample sizes but lacks large-scale validation using objective measures.
Methods:
This study was conducted with 268 Korean adults attending health check programs. Participants completed the PSQI-K questionnaire and wore Fitbit devices (Fitbit Inc., USA) to ascertain sleep parameters. Reliability was analyzed using the Cronbach’s α coefficient, and construct validity was determined through factor analysis. Criteria validity was assessed by correlating their index scores with Fitbit sleep parameters. We identified the optimal cutoff for detecting sleep disorders.
Results:
The Cronbach’s α coefficient was 0.61, indicating adequate internal consistency. Factor analysis revealed three factors, explaining 48.2% of sleep quality variance. The index scores were negatively correlated with Fitbit sleep efficiency, total sleep time, and number of awakenings (P<0.05). The optimal cutoff point for identifying sleep disorder groups was ≥6.
Conclusion
The PSQI-K demonstrated good reliability and validity when correlated with Fitbit sleep parameters, offering a practical screening tool for identifying sleep disorders among Korean adults. Cutoff scores can help identify patients for sleep interventions. However, further large-scale studies are required to validate these findings.
4.Erratum: Correction of Text in the Article “The Long-term Outcomes and Risk Factors of Complications After Fontan Surgery: From the Korean Fontan Registry (KFR)”
Sang-Yun LEE ; Soo-Jin KIM ; Chang-Ha LEE ; Chun Soo PARK ; Eun Seok CHOI ; Hoon KO ; Hyo Soon AN ; I Seok KANG ; Ja Kyoung YOON ; Jae Suk BAEK ; Jae Young LEE ; Jinyoung SONG ; Joowon LEE ; June HUH ; Kyung-Jin AHN ; Se Yong JUNG ; Seul Gi CHA ; Yeo Hyang KIM ; Youngseok LEE ; Sanghoon CHO
Korean Circulation Journal 2025;55(3):256-257
5.Testing the reliability and validity of the Korean version of the Pittsburgh Sleep Quality Index using Fitbit devices: a cross-sectional analysis
Si-Yeon LEE ; Ja-Eun CHOI ; Ji-Won LEE ; Yaeji LEE ; Jae-Min PARK ; Kyung-Won HONG
Korean Journal of Family Medicine 2025;46(1):42-47
Background:
Sleep disorders and insomnia are prevalent worldwide, with negative health outcomes. The Pittsburgh Sleep Quality Index (PSQI) is a widely used self-report assessment tool for evaluating sleep quality, comprising seven subdomains. The Korean version of the PSQI (PSQI-K) has been tested for reliability and validity in small sample sizes but lacks large-scale validation using objective measures.
Methods:
This study was conducted with 268 Korean adults attending health check programs. Participants completed the PSQI-K questionnaire and wore Fitbit devices (Fitbit Inc., USA) to ascertain sleep parameters. Reliability was analyzed using the Cronbach’s α coefficient, and construct validity was determined through factor analysis. Criteria validity was assessed by correlating their index scores with Fitbit sleep parameters. We identified the optimal cutoff for detecting sleep disorders.
Results:
The Cronbach’s α coefficient was 0.61, indicating adequate internal consistency. Factor analysis revealed three factors, explaining 48.2% of sleep quality variance. The index scores were negatively correlated with Fitbit sleep efficiency, total sleep time, and number of awakenings (P<0.05). The optimal cutoff point for identifying sleep disorder groups was ≥6.
Conclusion
The PSQI-K demonstrated good reliability and validity when correlated with Fitbit sleep parameters, offering a practical screening tool for identifying sleep disorders among Korean adults. Cutoff scores can help identify patients for sleep interventions. However, further large-scale studies are required to validate these findings.
6.Efficacy of Automatic Suction-Type Sonic Toothbrush and Manual Toothbrush in Preschool Children: A Randomized, Controlled Crossover Pilot Study
Su Bin LEE ; Yong Kwon CHAE ; Mi Sun KIM ; Ok Hyung NAM ; Hyo-Seol LEE ; Sung Chul CHOI ; Ko Eun LEE
Journal of Korean Academy of Pediatric Dentistry 2025;52(2):181-192
This study investigated the plaque removal efficacy of a suction-type sonic toothbrush compared to a conventional manual toothbrush in preschool children aged 30 to 59 months. Using a randomized, double-blind, crossover design with a 2-week washout period, 20 pediatric participants were allocated to two study phases, each using either the suction-type sonic toothbrush or the manual toothbrush with caregiver assistance. The plaque removal effectiveness was assessed through the Silness and Löe plaque index and quantitative light-induced fluorescence values, including ΔR30 and ΔR120 indicators of plaque index. The result showed no statistically significant differences in plaque removal efficacy between the two toothbrushes, although both showed similar improvements. Caregiver feedback revealed high acceptability of the suction-type sonic toothbrush due to its convenience and engaging features, such as a light and suction function, which enhanced the tooth brushing experience. Although limited by the short follow-up period and small sample size, the findings suggest that suction-type sonic toothbrushes may offer practical benefits for young children requiring caregiver assistance.
7.Interpretation, Reporting, Imaging-Based Workups, and Surveillance of Incidentally Detected Gallbladder Polyps and Gallbladder Wall Thickening: 2025 Recommendations From the Korean Society of Abdominal Radiology
Won CHANG ; Sunyoung LEE ; Yeun-Yoon KIM ; Jin Young PARK ; Sun Kyung JEON ; Jeong Eun LEE ; Jeongin YOO ; Seungchul HAN ; So Hyun PARK ; Jae Hyun KIM ; Hyo Jung PARK ; Jeong Hee YOON
Korean Journal of Radiology 2025;26(2):102-134
Incidentally detected gallbladder polyps (GBPs) and gallbladder wall thickening (GBWT) are frequently encountered in clinical practice. However, characterizing GBPs and GBWT in asymptomatic patients can be challenging and may result in overtreatment, including unnecessary follow-ups or surgeries. The Korean Society of Abdominal Radiology (KSAR) Clinical Practice Guideline Committee has developed expert recommendations that focus on standardized imaging interpretation and follow-up strategies for both GBPs and GBWT, with support from the Korean Society of Radiology and KSAR. These guidelines, which address 24 key questions, aim to standardize the approach for the interpretation of imaging findings, reporting, imaging-based workups, and surveillance of incidentally detected GBPs and GBWT. This recommendation promotes evidence-based practice, facilitates communication between radiologists and referring physicians, and reduces unnecessary interventions.
8.Imaging Findings of Complications of New Anticancer Drugs
Ji Sung JANG ; Hyo Jung PARK ; Chong Hyun SUH ; Sang Eun WON ; Eun Seong LEE ; Nari KIM ; Do-Wan LEE ; Kyung Won KIM
Korean Journal of Radiology 2025;26(2):156-168
The anticancer drugs have evolved significantly, spanning molecular targeted therapeutics (MTTs), immune checkpoint inhibitors (ICIs), chimeric antigen receptor T-cell (CAR-T) therapy, and antibody-drug conjugates (ADCs). Complications associated with these drugs vary widely based on their mechanisms of action. MTTs that target angiogenesis can often lead to complications related to ischemia or endothelial damage across various organs, whereas non-anti-angiogenic MTTs present unique complications derived from their specific pharmacological actions. ICIs are predominantly associated with immunerelated adverse events, such as pneumonitis, colitis, hepatitis, thyroid disorders, hypophysitis, and sarcoid-like reactions. CAR-T therapy causes unique and severe complications including cytokine release syndrome and immune effector cell-associated neurotoxicity syndrome. ADCs tend to cause complications associated with cytotoxic payloads. A comprehensive understanding of these drug-specific toxicities, particularly using medical imaging, is essential for providing optimal patient care. Based on this knowledge, radiologists can play a pivotal role in multidisciplinary teams. Therefore, radiologists must stay up-to-date on the imaging characteristics of these complications and the mechanisms underlying novel anticancer drugs.
9.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
10.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.

Result Analysis
Print