2.Coexisting Macular Hole and Uveal Melanoma: A Case Series and Literature Review
Yeji KIM ; So Hyun YU ; Yong Joon KIM ; Eun Young CHOI ; Sung Chul LEE ; Christopher Seungkyu LEE
Korean Journal of Ophthalmology 2025;39(2):170-180
Purpose:
To report five cases of macular hole (MH) coexisting with uveal melanoma (UM) and review the literature.
Methods:
Seventeen patients (5 new and 12 from previous reports) with coexisting MH and UM were reviewed. The patients were divided into two groups based on whether the MH was diagnosed before or after tumor treatment. The clinical features, pathogenesis, management options, and clinical outcomes were reviewed.
Results:
Of 505 patients with UM in our institution, 5 (1.0%) had a concurrent MH in the ipsilateral eye. The 17 patients reviewed had a mean age of 63.9 years at the time of MH diagnosis. Of 16 patients with available data on sex, 11 (64.7%) were female. There were no major differences in the demographic or clinical data of the groups. Of the 15 known tumor locations, 6 (35.3%) were juxtapapillary or macular. In patients who developed MH after UM treatment, the durations from tumor treatment (radiotherapy or transpupillary thermotherapy) to MH diagnosis were 3 to 56 months (median, 8.5 months). MH surgery was performed in nine eyes, and hole closure was achieved in seven eyes with postoperative data. The mean visual acuity showed a tendency of improvement after surgery. No intraocular or extraocular tumor dissemination associated with surgery was observed.
Conclusions
MH is observed in approximately 1% of patients with UM, either before or after tumor treatment. Of patients with coexisting MH and UM, MH surgery appears to be safe and effective in those with stable tumors and visual potential.
3.Effect of Combined Treatment of Metoclopramide With Platinum-Based Drugs on Apoptosis in AMC-HN4 Cells
Jong Won PARK ; Seon Min WOO ; Jong In JEONG ; Jae Man LEE ; Ji Won LEE ; Dong Eun KIM ; Taeg Kyu KWON
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(3):113-120
Background and Objectives:
Metoclopramide is an antagonist of dopamine D2 receptor and is capable of alleviating chemotherapy-induced nausea and vomiting. However, its underlying mechanisms and function in improving the efficiency of chemotherapy are not fully understood. In this study, we investigated the sensitizing effect of metoclopramide on the platinum-based drugs-mediated apoptosis in human head and neck cancer cells.Subjects and Method Apoptosis was analyzed using a cell-based cytometer. The protein expression and messenger ribonucleic acid (mRNA) levels were assessed by Western blotting and real-time polymerase chain reaction, respectively.
Results:
Metoclopramide sensitized the platinum-based drug (cisplatin and oxaliplatin)-mediated apoptosis in AMC-HN4 cells, but not in normal cells. Mechanistically, we found that metoclopramide decreased Mcl-1 protein expression through post-translational regulation. Moreover, the overexpression of Mcl-1 prevented apoptosis by combined treatment of metoclopramide and platinum-based drugs.
Conclusion
Metoclopramide induced proteasome-mediated Mcl-1 downregulation, resulting in increased sensitivity to platinum-based drugs.
4.Asparaginase-Associated Pancreatitis and Pancreatic Pseudocyst Managed with Endoscopic Cystogastrostomy in Adult Acute Lymphoblastic Leukemia
Gyewon PARK ; Eun Sun KIM ; Hyuk Soon CHOI ; Bora KEUM ; Yoon Tae JEEN ; Hoon Jai CHUN ; Hong Sik LEE ; Jae Min LEE
Korean Journal of Pancreas and Biliary Tract 2025;30(1):31-35
Anticancer treatment for acute lymphocytic leukemia is based on drugs such as methotrexate, 6-mercaptopurine, vincristine, and asparaginase. Asparaginase-related pancreatitis is known to have an incidence of up to 18%, and is a major cause of discontinuation of anticancer treatment for leukemia due to acute onset and chronic complications. There were various cases of treatment of peripancreatic fluid retention caused by anticancer drugs in leukemia patients. Use of lumen-apposing metal stents (LAMS) for walled-off necrosis (WON) drainage has recently increased. The electrocautery-enhanced delivery system allowed simpler and faster stent placement, streamlining the overall procedure and potentially reducing procedure time. Therefore, favorable outcomes have been reported with the use of LAMS for endoscopic drainage of various conditions. In this paper, we discuss a case in which hot-system LAMS was performed to treat L-asparaginase-induced acute pancreatitis and pancreatic pseudocyst in an adult patient with acute lymphoblastic leukemia.
5.Biennial Mammography Performance in the Korean National Cancer Screening Program From 2009 to 2020
Dong Jun KIM ; Nan-He YOON ; Jae Kwan JUN ; Mina SUH ; Sunhwa LEE ; Seongju KIM ; Horim A. HWANG ; Seung Eun JUNG ; Hooyeon LEE
Korean Journal of Radiology 2025;26(4):313-323
Objective:
Mammography is essential for reducing breast cancer mortality; however, its performance varies globally. This study aimed to evaluate mammography screening outcomes in Korea over 12 years and investigate regional variations.
Materials and Methods:
We analyzed mammography data from 42 million Korean women, aged 40 years and older, who participated in the Korean National Cancer Screening Program (KNCSP) from 2009 to 2020. Performance metrics—including recall rate (RR), positive predictive value (PPV), sensitivity, specificity, false positive rate (FPR), cancer detection rate (CDR), interval cancer rate (ICR), and dense breast rate (DBR), were computed. Twelve-year trends in these metrics were analyzed using Joinpoint regression. Regional variations were also examined across Korea’s 237 districts, stratified by age groups.
Results:
From 2009 to 2020, 42165405 mammography screenings were conducted through the KNCSP, increasing from 2821132 screenings in 2009 to 3596204 in 2020. The RR decreased from 17.2% in 2009 to 11.2% in 2020 (average annual percent change [AAPC] = -3.7%), while the PPV increased from 0.8% to 2.8%; AAPC = 10.7%), the CDR increased from 1.5 to 3.1 per 1000; AAPC = 7.3%), and the ICR rose from 0.9 to 1.6 per 1000; (AAPC = 5.2%). Regional variations were noted; however, differences in the RR, sensitivity, specificity, and FPR decreased over time.
Conclusion
While mammography performance improved from 2009 to 2020, the PPV and sensitivity remain suboptimal, underscoring the need for continuous monitoring. Regional disparities in performance, although reduced, persist. These findings provide essential baseline data for improving mammography quality and addressing inequities in breast cancer screening.
6.Interpretation, Reporting, Imaging-Based Workups, and Surveillance of Incidentally Detected Gallbladder Polyps and Gallbladder Wall Thickening: 2025 Recommendations From the Korean Society of Abdominal Radiology
Won CHANG ; Sunyoung LEE ; Yeun-Yoon KIM ; Jin Young PARK ; Sun Kyung JEON ; Jeong Eun LEE ; Jeongin YOO ; Seungchul HAN ; So Hyun PARK ; Jae Hyun KIM ; Hyo Jung PARK ; Jeong Hee YOON
Korean Journal of Radiology 2025;26(2):102-134
Incidentally detected gallbladder polyps (GBPs) and gallbladder wall thickening (GBWT) are frequently encountered in clinical practice. However, characterizing GBPs and GBWT in asymptomatic patients can be challenging and may result in overtreatment, including unnecessary follow-ups or surgeries. The Korean Society of Abdominal Radiology (KSAR) Clinical Practice Guideline Committee has developed expert recommendations that focus on standardized imaging interpretation and follow-up strategies for both GBPs and GBWT, with support from the Korean Society of Radiology and KSAR. These guidelines, which address 24 key questions, aim to standardize the approach for the interpretation of imaging findings, reporting, imaging-based workups, and surveillance of incidentally detected GBPs and GBWT. This recommendation promotes evidence-based practice, facilitates communication between radiologists and referring physicians, and reduces unnecessary interventions.
7.Evaluation of Image Quality and Scan Time Efficiency in Accelerated 3D T1-Weighted Pediatric Brain MRI Using Deep Learning-Based Reconstruction
Hyunsuk YOO ; Hee Eun MOON ; Soojin KIM ; Da Hee KIM ; Young Hun CHOI ; Jeong-Eun CHEON ; Joon Sung LEE ; Seunghyun LEE
Korean Journal of Radiology 2025;26(2):180-192
Objective:
This study evaluated the effect of an accelerated three-dimensional (3D) T1-weighted pediatric brain MRI protocol using a deep learning (DL)-based reconstruction algorithm on scan time and image quality.
Materials and Methods:
This retrospective study included 46 pediatric patients who underwent conventional and accelerated, pre- and post-contrast, 3D T1-weighted brain MRI using a 3T scanner (SIGNA Premier; GE HealthCare) at a single tertiary referral center between March 1, 2023, and April 30, 2023. Conventional scans were reconstructed using intensity Filter A (Conv), whereas accelerated scans were reconstructed using intensity Filter A (Fast_A) and a DL-based algorithm (Fast_DL).Image quality was assessed quantitatively based on the coefficient of variation, relative contrast, apparent signal-to-noise ratio (aSNR), and apparent contrast-to-noise ratio (aCNR) and qualitatively according to radiologists’ ratings of overall image quality, artifacts, noisiness, gray-white matter differentiation, and lesion conspicuity.
Results:
The acquisition times for the pre- and post-contrast scans were 191 and 135 seconds, respectively, for the conventional scan. With the accelerated protocol, these were reduced to 135 and 80 seconds, achieving time reductions of 29.3% and 40.7%, respectively. DL-based reconstruction significantly reduced the coefficient of variation, improved the aSNR, aCNR, and overall image quality, and reduced the number of artifacts compared with the conventional acquisition method (all P < 0.05). However, the lesion conspicuity remained similar between the two protocols.
Conclusion
Utilizing a DL-based reconstruction algorithm in accelerated 3D T1-weighted pediatric brain MRI can significantly shorten the acquisition time, enhance image quality, and reduce artifacts, making it a viable option for pediatric imaging.
8.Imaging Findings of Complications of New Anticancer Drugs
Ji Sung JANG ; Hyo Jung PARK ; Chong Hyun SUH ; Sang Eun WON ; Eun Seong LEE ; Nari KIM ; Do-Wan LEE ; Kyung Won KIM
Korean Journal of Radiology 2025;26(2):156-168
The anticancer drugs have evolved significantly, spanning molecular targeted therapeutics (MTTs), immune checkpoint inhibitors (ICIs), chimeric antigen receptor T-cell (CAR-T) therapy, and antibody-drug conjugates (ADCs). Complications associated with these drugs vary widely based on their mechanisms of action. MTTs that target angiogenesis can often lead to complications related to ischemia or endothelial damage across various organs, whereas non-anti-angiogenic MTTs present unique complications derived from their specific pharmacological actions. ICIs are predominantly associated with immunerelated adverse events, such as pneumonitis, colitis, hepatitis, thyroid disorders, hypophysitis, and sarcoid-like reactions. CAR-T therapy causes unique and severe complications including cytokine release syndrome and immune effector cell-associated neurotoxicity syndrome. ADCs tend to cause complications associated with cytotoxic payloads. A comprehensive understanding of these drug-specific toxicities, particularly using medical imaging, is essential for providing optimal patient care. Based on this knowledge, radiologists can play a pivotal role in multidisciplinary teams. Therefore, radiologists must stay up-to-date on the imaging characteristics of these complications and the mechanisms underlying novel anticancer drugs.
9.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
10.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.

Result Analysis
Print
Save
E-mail