1.Dietary Status of Preterm Infants and the Need for Community Care
Ji Su JEON ; Won Hee SEO ; Eun mi WHANG ; Bu Kyung KIM ; Eui Kyung CHOI ; Jang Hoon LEE ; Jeong Hee SHIN ; Young Shin HAN ; Sang-Jin CHUNG
Korean Journal of Community Nutrition 2022;27(4):273-285
Objectives:
This study compared the nutritional intakes of early and late preterm infants in a neonatal intensive care unit (NICU) and at home. The dietary problems and the need for community care services for premature infants were further investigated.
Methods:
This is a cross-sectional and descriptive study on 125 preterm infants and their parents (Early preterm n = 70, Late preterm n = 55). The data were collected by surveying the parents of preterm infants and from hospital medical records.
Results:
No significant differences were obtained between the early and late preterm infant groups when considering the proportion of feeding types in the NICU and at home. Early preterm infants were fed with a greater amount of additional calories at home and had more hours of tube feeding (P = 0.022). Most preterm infants had feeding problems. However, there was no significant difference between early and late preterm infants in the mental pain of parents, sleeping, feeding, and weaning problems at home. Many parents of preterm babies had no external support, and more than half the parents required community care to take care of their preterm babies.
Conclusions
Regardless of the gestational age, most preterm infants have several problems with dietary intake. Our study indicates the need to establish community care services for preterm infants.
2.Usefulness of Refractive Measurement by Wavefront Aberrometer in Children
Si Eun OH ; Woong Joo WHANG ; Mi Ra PARK
Journal of the Korean Ophthalmological Society 2021;62(5):680-687
Purpose:
To compare the refractive measurements from a wavefront aberrometer, autorefractor, and retinoscopy after cycloplegia in evaluating the usefulness and validity of refractive measurements by a wavefront aberrometer in children.
Methods:
A total of 130 eyes of 65 children, aged from 3 to 16 years, were examined using retinoscopy, a wavefront aberrometer (OPD-Scan III), and an autorefractor (KR-1) after cycloplegia. Refractive measurements were converted to power vectors (M, J0, and J45) and cylindrical absolute values for statistical analysis. The agreement between instruments was assessed and the correlations of measurements were evaluated. Subgroup analysis was performed on two subgroups: one representing less refractive error (|M| < 2 D on cycloplegic retinoscopy) and the other with larger refractive error (|M| ≥ 2 D on cycloplegic retinoscopy).
Results:
Compared with retinoscopy readings, the aberrometer and autorefractor yielded more myopic values (p = 0.007, p < 0.001). In the less refractive error group, the autorefractor results showed statistically significant differences from retinoscopy readings for M, J0, and J45 and the cylindrical absolute value (all p < 0.05); there were no statistically significant differences between M, J0, and J45 vectors of the aberrometer and those obtained using retinoscopy (p = 0.674, p = 0.699, p = 0.766). With the larger refractive error group, the M vectors of the aberrometer and autorefractor showed more myopic values than the M vector retinoscopy readings; the differences were statistically significant (all p < 0.001).
Conclusions
The wavefront aberrometer yielded refraction readings closer to those obtained with retinoscopy than the automated refraction in the less refractive error group. With a larger refractive error, statistically significant differences (all p < 0.001) were found among the aberrometer, autorefractor, and retinoscopy readings.
3.Usefulness of Refractive Measurement by Wavefront Aberrometer in Children
Si Eun OH ; Woong Joo WHANG ; Mi Ra PARK
Journal of the Korean Ophthalmological Society 2021;62(5):680-687
Purpose:
To compare the refractive measurements from a wavefront aberrometer, autorefractor, and retinoscopy after cycloplegia in evaluating the usefulness and validity of refractive measurements by a wavefront aberrometer in children.
Methods:
A total of 130 eyes of 65 children, aged from 3 to 16 years, were examined using retinoscopy, a wavefront aberrometer (OPD-Scan III), and an autorefractor (KR-1) after cycloplegia. Refractive measurements were converted to power vectors (M, J0, and J45) and cylindrical absolute values for statistical analysis. The agreement between instruments was assessed and the correlations of measurements were evaluated. Subgroup analysis was performed on two subgroups: one representing less refractive error (|M| < 2 D on cycloplegic retinoscopy) and the other with larger refractive error (|M| ≥ 2 D on cycloplegic retinoscopy).
Results:
Compared with retinoscopy readings, the aberrometer and autorefractor yielded more myopic values (p = 0.007, p < 0.001). In the less refractive error group, the autorefractor results showed statistically significant differences from retinoscopy readings for M, J0, and J45 and the cylindrical absolute value (all p < 0.05); there were no statistically significant differences between M, J0, and J45 vectors of the aberrometer and those obtained using retinoscopy (p = 0.674, p = 0.699, p = 0.766). With the larger refractive error group, the M vectors of the aberrometer and autorefractor showed more myopic values than the M vector retinoscopy readings; the differences were statistically significant (all p < 0.001).
Conclusions
The wavefront aberrometer yielded refraction readings closer to those obtained with retinoscopy than the automated refraction in the less refractive error group. With a larger refractive error, statistically significant differences (all p < 0.001) were found among the aberrometer, autorefractor, and retinoscopy readings.
4.Quantitative Analysis of the Effect of Iterative Reconstruction Using a Phantom: Determining the Appropriate Blending Percentage.
Hyun Gi KIM ; Yong Eun CHUNG ; Young Han LEE ; Jin Young CHOI ; Mi Suk PARK ; Myeong Jin KIM ; Ki Whang KIM
Yonsei Medical Journal 2015;56(1):253-261
PURPOSE: To investigate the optimal blending percentage of adaptive statistical iterative reconstruction (ASIR) in a reduced radiation dose while preserving a degree of image quality and texture that is similar to that of standard-dose computed tomography (CT). MATERIALS AND METHODS: The CT performance phantom was scanned with standard and dose reduction protocols including reduced mAs or kVp. Image quality parameters including noise, spatial, and low-contrast resolution, as well as image texture, were quantitatively evaluated after applying various blending percentages of ASIR. The optimal blending percentage of ASIR that preserved image quality and texture compared to standard dose CT was investigated in each radiation dose reduction protocol. RESULTS: As the percentage of ASIR increased, noise and spatial-resolution decreased, whereas low-contrast resolution increased. In the texture analysis, an increasing percentage of ASIR resulted in an increase of angular second moment, inverse difference moment, and correlation and in a decrease of contrast and entropy. The 20% and 40% dose reduction protocols with 20% and 40% ASIR blending, respectively, resulted in an optimal quality of images with preservation of the image texture. CONCLUSION: Blending the 40% ASIR to the 40% reduced tube-current product can maximize radiation dose reduction and preserve adequate image quality and texture.
*Algorithms
;
Artifacts
;
Contrast Media/diagnostic use
;
Humans
;
*Phantoms, Imaging
;
Radiation Dosage
;
Radiographic Image Interpretation, Computer-Assisted/*methods
;
Signal-To-Noise Ratio
;
Tomography, X-Ray Computed
5.Scopoletin from Cirsium setidens Increases Melanin Synthesis via CREB Phosphorylation in B16F10 Cells.
Mi Ja AHN ; Sun Jung HUR ; Eun Hyun KIM ; Seung Hoon LEE ; Jun Seob SHIN ; Myo Kyoung KIM ; James A UCHIZONO ; Wan Kyunn WHANG ; Dong Seok KIM
The Korean Journal of Physiology and Pharmacology 2014;18(4):307-311
In this study, we isolated scopoletin from Cirsium setidens Nakai (Compositae) and tested its effects on melanogenesis. Scopoletin was not toxic to cells at concentrations less than 50 microM and increased melanin synthesis in a dose-dependent manner. As melanin synthesis increased, scopoletin stimulated the total tyrosinase activity, the rate-limiting enzyme of melanogenesis. In a cell-free system, however, scopoletin did not increase tyrosinase activity, indicating that scopoletin is not a direct activator of tyrosinase. Furthermore, Western blot analysis showed that scopoletin stimulated the production of microphthalmia-associated transcription factor (MITF) and tyrosinase expression via cAMP response element-binding protein (CREB) phosphorylation in a dose-dependent manner. Based on these results, preclinical and clinical studies are needed to assess the use of scopoletin for the treatment of vitiligo.
Blotting, Western
;
Cell-Free System
;
Cirsium*
;
Cyclic AMP Response Element-Binding Protein
;
Melanins*
;
Microphthalmia-Associated Transcription Factor
;
Monophenol Monooxygenase
;
Phosphorylation*
;
Scopoletin*
;
Vitiligo
6.Radiation Dose Reduction via Sinogram Affirmed Iterative Reconstruction and Automatic Tube Voltage Modulation (CARE kV) in Abdominal CT.
Hyun Joo SHIN ; Yong Eun CHUNG ; Young Han LEE ; Jin Young CHOI ; Mi Suk PARK ; Myeong Jin KIM ; Ki Whang KIM
Korean Journal of Radiology 2013;14(6):886-893
OBJECTIVE: To evaluate the feasibility of sinogram-affirmed iterative reconstruction (SAFIRE) and automated kV modulation (CARE kV) in reducing radiation dose without increasing image noise for abdominal CT examination. MATERIALS AND METHODS: This retrospective study included 77 patients who received CT imaging with an application of CARE kV with or without SAFIRE and who had comparable previous CT images obtained without CARE kV or SAFIRE, using the standard dose (i.e., reference mAs of 240) on an identical CT scanner and reconstructed with filtered back projection (FBP) within 1 year. Patients were divided into two groups: group A (33 patients, CT scanned with CARE kV); and group B (44 patients, scanned after reducing the reference mAs from 240 to 170 and applying both CARE kV and SAFIRE). CT number, image noise for four organs and radiation dose were compared among the two groups. RESULTS: Image noise increased after CARE kV application (p < 0.001) and significantly decreased as SAFIRE strength increased (p < 0.001). Image noise with reduced-mAs scan (170 mAs) in group B became similar to that of standard-dose FBP images after applying CARE kV and SAFIRE strengths of 3 or 4 when measured in the aorta, liver or muscle (p > or = 0.108). Effective doses decreased by 19.4% and 41.3% for groups A and B, respectively (all, p < 0.001) after application of CARE kV with or without SAFIRE. CONCLUSION: Combining CARE kV, reduction of mAs from 240 to 170 mAs and noise reduction by applying SAFIRE strength 3 or 4 reduced the radiation dose by 41.3% without increasing image noise compared with the standard-dose FBP images.
Adult
;
Aged
;
Aged, 80 and over
;
*Algorithms
;
Equipment Design
;
Female
;
Humans
;
Male
;
Middle Aged
;
Multidetector Computed Tomography/adverse effects/*instrumentation
;
Radiation Dosage
;
Radiation Injuries/etiology/*prevention & control
;
Radiographic Image Interpretation, Computer-Assisted/*methods
;
Radiography, Abdominal/adverse effects/*methods
;
Retrospective Studies
7.Malignant Mixed Mullerian Tumor with Small Bowel Metastasis: A Case Report.
Yeo Jin LEE ; Yong Eun CHUNG ; Kwang Hun LEE ; Mi Suk PARK ; Joon Seok LIM ; Jin Young CHOI ; Kyung Ah KIM ; Myeong Jin KIM ; Ki Whang KIM
Journal of the Korean Society of Magnetic Resonance in Medicine 2012;16(3):257-261
Malignant mixed Mullerian tumors (MMMT) are rare aggressive tumors that typically arise fromthe female genital tract. This malignancy has an extremely poor prognosis due to its rapid growthand the high associated incidence of both local recurrence and distant metastases. Althoughintraperitoneal metastasis from MMMT is relatively common, no reports exist regarding theradiologic findings of intestinal metastasis from MMMT. Here, we report a case of MMMT withsecondary small bowel metastasis and the associated radiologic findings.
Female
;
Humans
;
Incidence
;
Neoplasm Metastasis
;
Prognosis
;
Recurrence
8.Focal Liver Lesion Detection in Gadoxetic Acid-enhanced Liver MRI: Effects of Scan Delay, Hepatic Function, and Magnetic Field Strength.
Hua Sun KIM ; Myeong Jin KIM ; Jae Joon CHUNG ; Joon Suk LIM ; Yong Eun CHUNG ; Mi Suk PARK ; Ki Whang KIM
Journal of the Korean Society of Magnetic Resonance in Medicine 2011;15(3):226-233
PURPOSE: To determine the effects of scan delay, hepatic function, and magnetic field strength on the performance of gadoxetic acid enhanced magnetic resonance imaging. MATERIALS AND METHODS: Gadoxetic acid enhanced MRI conducted in 72 patients with 10 minutes and 20 minutes delay were reviewed retrospectively. For quantitative analysis, liver-to-lesion signal difference ratio (SDR) was measured and compared according to scan delay time, hepatic function and magnetic field strength. For qualitative analysis, two board-certificated radiologists reviewed 10-minute delay and 20-minute delay images. The sensitivity and specificity of each reader was compared. RESULTS: The SDR of 20-minute images in non-cirrhotic patients was significantly higher (p < 0.01) than that of 10-minute delay images. However, in cirrhotic patients, it was comparable (p > 0.05) to 10-min delay images. In comparisons according to the magnetic strength, there was no significant difference between 1.5-T and 3.0-T systems. Comparisons of ROC curves showed no statistically significant differences in sensitivity and specificity between 10-minute and 20-minute delay images. CONCLUSION: An increase in the liver-to-lesion signal difference ratio was dependent on the patients' hepatic function but not dependent on the magnetic strength. There was no significant difference in sensitivity or specificity between the 10-minute and 20-minute delay images.
Gadolinium DTPA
;
Humans
;
Liver
;
Magnetic Fields
;
Magnetic Resonance Spectroscopy
;
Magnetics
;
Magnets
;
Retrospective Studies
;
ROC Curve
;
Sensitivity and Specificity
9.MRI Findings of Rectal Submucosal Tumors.
Honsoul KIM ; Joo Hee KIM ; Joon Seok LIM ; Jin Young CHOI ; Yong Eun CHUNG ; Mi Suk PARK ; Myeong Jin KIM ; Ki Whang KIM ; Sang Kyum KIM
Korean Journal of Radiology 2011;12(4):487-498
Rectal submucosal lesions encompass a wide variety of benign and malignant tumors involving the rectum. With optical colonoscopy, any mass-like protrusion covered by normal mucosa, whether the underlying process is intramural or extramural in origin, may be reported as a submucosal lesion. Whereas the assessment of submucosal lesions may be limited with performing optical colonoscopy, cross-sectional imaging such as CT, transrectal ultrasonography and MRI allows the evaluation of perirectal tissues and pelvic organs in addition to the entire thickness of the rectum, and so this is advantageous for the assessment of rectal submucosal tumors. Among these, MRI is the best investigative modality for soft tissue characterization. Therefore, knowledge of the MRI features of rectal submucosal tumors can help achieve accurate preoperative diagnoses and facilitate the appropriate management.
Colonoscopy
;
Diagnosis, Differential
;
Humans
;
Intestinal Mucosa/*pathology
;
Magnetic Resonance Imaging/*methods
;
Rectal Neoplasms/*diagnosis/pathology
10.Pancreatic Tumors: Emphasis on CT Findings and Pathologic Classification.
Hee Woo CHO ; Jin Young CHOI ; Myeong Jin KIM ; Mi Suk PARK ; Joon Seok LIM ; Yong Eun CHUNG ; Ki Whang KIM
Korean Journal of Radiology 2011;12(6):731-739
Pancreatic tumors can be classified by their morphologic features on CT. The subtypes include solid tumors, mixed cystic and solid lesions, unilocular cysts, multilocular cystic lesions, and microcystic lesions. Endoscopic US and MRI can provide detailed information for classifying pancreatic lesions. Each subtype has different kinds of tumors and malignant potential, thus the classification can be useful for a better differential diagnosis and treatment planning. For this purpose, we suggest an appropriate modified classification system by using the imaging features of pancreatic tumors with an emphasis on CT findings and illustrate various findings of typical and atypical manifestations.
Endosonography
;
Humans
;
Magnetic Resonance Imaging
;
Multidetector Computed Tomography
;
Pancreatic Neoplasms/classification/pathology/*radiography
;
*Tomography, X-Ray Computed

Result Analysis
Print
Save
E-mail