1.Minocycline Susceptibility of Carbapenem-Resistant Acinetobacter baumannii Blood Isolates from a Single Center in Korea: Role of tetB in Resistance
Taeeun KIM ; Eun Hee JEON ; Yoon-Kyoung HONG ; Jiwon JUNG ; Min Jae KIM ; Heungsup SUNG ; Mi-Na KIM ; Sung-Han KIM ; Sang-Ho CHOI ; Sang-Oh LEE ; Yang Soo KIM ; Yong Pil CHONG
Infection and Chemotherapy 2025;57(1):111-118
Background:
Carbapenem-resistant Acinetobacter baumannii (CRAB) represents a devastating and growing global threat, calling for new antibiotic treatments. In Korea, the challenge of treating CRAB is compounded by high nosocomial acquisition rates and limited availability of novel antibiotics. Minocycline, a semisynthetic tetracycline derivative, has been proposed as a therapeutic option for CRAB infections. Nonsusceptibility to minocycline may occur through the efflux pump, TetB. The prevalence of tetB in A. baumannii has increased, along with higher minocycline minimum inhibitory concentrations (MICs). We aimed to evaluate minocycline susceptibility rates in clinical strains of CRAB, and the association between tetB carriage and minocycline susceptibility across different genotypes.
Materials and Methods:
Representative CRAB blood isolates were collected from Asan Medical Center, Seoul.Minocycline susceptibility was assessed using the Clinical and Laboratory Standards Institute (CLSI) breakpoint (≤4 mg/L) and the proposed pharmacokinetics (PK)/pharmacodynamics (PD) breakpoint (≤1 mg/L). Tigecycline was used as a comparator, and its susceptibility breakpoint for Enterobacterales defined by EUCAST was applied (≤0.5 mg/L).The presence of tetB was detected by PCR, and multilocus sequence typing (MLST) was performed using seven housekeeping genes.
Results:
Of the 160 CRAB blood isolates, 83.8% were susceptible to minocycline by the CLSI criteria, and 50.6% were PK-PD susceptible by the PK-PD criteria. The minocycline minimum inhibitory concentration (MIC)50 /MIC90 was 1/8 mg/L. tetB was present in 49% of isolates and was associated with a higher minocycline MIC (MIC50/90 2/8 mg/L vs. 1/2 mg/L). No clear correlation was observed between tetB positivity and tigecycline MIC. Nine MLSTs were identified, with significant differences in tetB carriage rates between the major sequence types. Notably, ST191, associated with non-tetB carriage and greater susceptibility to minocycline, declined over the study period (P=0.004), while ST451, associated with tetB carriage, increased.
Conclusion
tetB was present in 49% of CRAB isolates and was associated with higher MICs and non-susceptibility by both CLSI and PK-PD criteria. However, absence of tetB was not a reliable predictor of minocycline PK-PD susceptibility. Additionally, shifts over time towards genotypes with reduced minocycline susceptibility were observed. Further research is needed to correlate these findings with clinical outcomes and identify additional resistance mechanisms.
2.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
3.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
4.Development of the Korean Version of the Meaning in Life Scale for Cancer Patients
Namgu KANG ; Hae-Yeon YUN ; Young Ae KIM ; Hye Yoon PARK ; Jong-Heun KIM ; Sun Mi KIM ; Eun-Seung YU
Psychiatry Investigation 2025;22(3):258-266
Objective:
This study aims to understand the structure of meaning in life among patients with cancer through the validation of the Meaning in Life Scale among Korean patients (K-MiLS) with cancer.
Methods:
From August 2021 to November 2022, participants were recruited from multiple sites in South Korea. Participants completed related questionnaires, including the MiLS, on the web or mobile. Test-retest reliability was assessed between 2 and 4 weeks after the initial assessment. Exploratory and confirmatory factor analyses and Pearson’s correlations were used to evaluate the reliability and validity of the MiLS. A multiple regression analysis was conducted to examine the sociodemographic and disease-related variables correlated with the MiLS. Regarding concurrent validity, a hierarchical regression analysis was performed.
Results:
The results (n=345) indicated that the K-MiLS has a four-factor structure: Harmony and Peace; Life Perspective, Purpose, and Goals; Confusion and Lessened Meaning; and Benefits of Spirituality. Regarding convergent and discriminant validity, K-MiLS was negatively correlated with Patient Health Questionnaire-9, Generalized Anxiety Disorder-7, and Fear of Cancer Recurrence Inventory while showing a significantly positive correlation with the Posttraumatic Growth Inventory, Self-Compassion Scale, Functional Assessment of Cancer Therapy-General, and Functional Social Support Questionnaire. Hierarchical regression analysis revealed that the demographic variable influencing MiLS was religious affiliation.
Conclusion
The K-MiLS had a multidimensional four-factor structure similar to that of the original version. It is also a reliable and valid measure for assessing cancer survivors’ meaning in life after a cancer diagnosis.
5.A practical guide for enteral nutrition from the Korean Society for Parenteral and Enteral Nutrition: Part I. prescribing enteral nutrition orders
Ye Rim CHANG ; Bo-Eun KIM ; In Seok LEE ; Youn Soo CHO ; Sung-Sik HAN ; Eunjung KIM ; Hyunjung KIM ; Jae Hak KIM ; Jeong Wook KIM ; Sung Shin KIM ; Eunhee KONG ; Ja Kyung MIN ; Chi-Min PARK ; Jeongyun PARK ; Seungwan RYU ; Kyung Won SEO ; Jung Mi SONG ; Minji SEOK ; Eun-Mi SEOL ; Jinhee YOON ; Jeong Meen SEO ;
Annals of Clinical Nutrition and Metabolism 2025;17(1):3-8
Purpose:
This study aimed to develop a comprehensive practical guide for enteral nutrition (EN) designed to enhance patient safety and reduce complications in Korea. Under the leadership of the Korean Society for Parenteral and Enteral Nutrition (KSPEN), the initiative sought to standardize EN procedures, improve decision-making, and promote effective multidisciplinary communication.
Methods:
The KSPEN EN committee identified key questions related to EN practices and organized them into seven sections such as prescribing, delivery route selection, formula preparation, administration, and quality management. Twenty-one experts, selected based on their expertise, conducted a thorough literature review to formulate evidence-based recommendations. Drafts underwent peer review both within and across disciplines, with final revisions completed by the KSPEN Guideline Committee. The guide, which will be published in three installments, addresses critical elements of EN therapy and safety protocols.
Results:
The practical guide recommends that EN orders include detailed elements and advocates the use of electronic medical records for communication. Standardized prescription forms and supplementary safety measures are outlined. Review frequency is adjusted according to patient condition—daily for critically ill or unstable patients and as dictated by institutional protocols for stable patients. Evidence indicates that adherence to these protocols reduces mortality, complications, and prescription errors.
Conclusion
The KSPEN practical guide offers a robust framework for the safe delivery of EN tailored to Korea’s healthcare context. It emphasizes standardized protocols and interdisciplinary collaboration to improve nutritional outcomes, patient safety, and operational efficiency. Rigorous implementation and monitoring of adherence are critical for its success.
6.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
7.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
8.Development of the Korean Version of the Meaning in Life Scale for Cancer Patients
Namgu KANG ; Hae-Yeon YUN ; Young Ae KIM ; Hye Yoon PARK ; Jong-Heun KIM ; Sun Mi KIM ; Eun-Seung YU
Psychiatry Investigation 2025;22(3):258-266
Objective:
This study aims to understand the structure of meaning in life among patients with cancer through the validation of the Meaning in Life Scale among Korean patients (K-MiLS) with cancer.
Methods:
From August 2021 to November 2022, participants were recruited from multiple sites in South Korea. Participants completed related questionnaires, including the MiLS, on the web or mobile. Test-retest reliability was assessed between 2 and 4 weeks after the initial assessment. Exploratory and confirmatory factor analyses and Pearson’s correlations were used to evaluate the reliability and validity of the MiLS. A multiple regression analysis was conducted to examine the sociodemographic and disease-related variables correlated with the MiLS. Regarding concurrent validity, a hierarchical regression analysis was performed.
Results:
The results (n=345) indicated that the K-MiLS has a four-factor structure: Harmony and Peace; Life Perspective, Purpose, and Goals; Confusion and Lessened Meaning; and Benefits of Spirituality. Regarding convergent and discriminant validity, K-MiLS was negatively correlated with Patient Health Questionnaire-9, Generalized Anxiety Disorder-7, and Fear of Cancer Recurrence Inventory while showing a significantly positive correlation with the Posttraumatic Growth Inventory, Self-Compassion Scale, Functional Assessment of Cancer Therapy-General, and Functional Social Support Questionnaire. Hierarchical regression analysis revealed that the demographic variable influencing MiLS was religious affiliation.
Conclusion
The K-MiLS had a multidimensional four-factor structure similar to that of the original version. It is also a reliable and valid measure for assessing cancer survivors’ meaning in life after a cancer diagnosis.
9.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
10.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.

Result Analysis
Print
Save
E-mail