1.Practice guidelines for managing extrahepatic biliary tract cancers
Hyung Sun KIM ; Mee Joo KANG ; Jingu KANG ; Kyubo KIM ; Bohyun KIM ; Seong-Hun KIM ; Soo Jin KIM ; Yong-Il KIM ; Joo Young KIM ; Jin Sil KIM ; Haeryoung KIM ; Hyo Jung KIM ; Ji Hae NAHM ; Won Suk PARK ; Eunkyu PARK ; Joo Kyung PARK ; Jin Myung PARK ; Byeong Jun SONG ; Yong Chan SHIN ; Keun Soo AHN ; Sang Myung WOO ; Jeong Il YU ; Changhoon YOO ; Kyoungbun LEE ; Dong Ho LEE ; Myung Ah LEE ; Seung Eun LEE ; Ik Jae LEE ; Huisong LEE ; Jung Ho IM ; Kee-Taek JANG ; Hye Young JANG ; Sun-Young JUN ; Hong Jae CHON ; Min Kyu JUNG ; Yong Eun CHUNG ; Jae Uk CHONG ; Eunae CHO ; Eui Kyu CHIE ; Sae Byeol CHOI ; Seo-Yeon CHOI ; Seong Ji CHOI ; Joon Young CHOI ; Hye-Jeong CHOI ; Seung-Mo HONG ; Ji Hyung HONG ; Tae Ho HONG ; Shin Hye HWANG ; In Gyu HWANG ; Joon Seong PARK
Annals of Hepato-Biliary-Pancreatic Surgery 2024;28(2):161-202
Background:
s/Aims: Reported incidence of extrahepatic bile duct cancer is higher in Asians than in Western populations. Korea, in particular, is one of the countries with the highest incidence rates of extrahepatic bile duct cancer in the world. Although research and innovative therapeutic modalities for extrahepatic bile duct cancer are emerging, clinical guidelines are currently unavailable in Korea. The Korean Society of Hepato-Biliary-Pancreatic Surgery in collaboration with related societies (Korean Pancreatic and Biliary Surgery Society, Korean Society of Abdominal Radiology, Korean Society of Medical Oncology, Korean Society of Radiation Oncology, Korean Society of Pathologists, and Korean Society of Nuclear Medicine) decided to establish clinical guideline for extrahepatic bile duct cancer in June 2021.
Methods:
Contents of the guidelines were developed through subgroup meetings for each key question and a preliminary draft was finalized through a Clinical Guidelines Committee workshop.
Results:
In November 2021, the finalized draft was presented for public scrutiny during a formal hearing.
Conclusions
The extrahepatic guideline committee believed that this guideline could be helpful in the treatment of patients.
2.Root proximity of the anchoring miniscrews of orthodontic miniplates in the mandibular incisal area: Cone-beam computed tomographic analysis
Do-Min JEONG ; Song Hee OH ; HyeRan CHOO ; Yong-Suk CHOI ; Seong-Hun KIM ; Jin-Suk LEE ; Eui-Hwan HWANG
The Korean Journal of Orthodontics 2021;51(4):231-240
Objective:
This outcome analysis study evaluated the actual positions of the orthodontic miniplate and miniplate anchoring screws (MPASs) and the risk factors affecting adjacent anatomic structures after miniplate placement in the mandibular incisal area.
Methods:
Cone-beam computed tomographic images of 97 orthodontic miniplates and their 194 MPASs (diameter, 1.5 mm; length, 4 mm) in patients whose miniplates provided sufficient clinical stability for orthodontic treatment were retrospectively reviewed. For evaluating the actual positions of the miniplates and analyzing the risk factors, including the effects on adjacent roots, MPAS placement height (PH), placement depth (PD), plate angle (PA), mental fossa angle (MA), and root proximity were assessed using the paired t-test, analysis of variance, and generalized linear model and regression analyses.
Results:
The mean PDs of MPASs at positions 1 (P1) and 2 (P2) were 2.01 mm and 2.23 mm, respectively. PA was significantly higher in the Class III malocclusion group than in the other groups. PH was positively correlated with MA and PD at P1. Of the 97 MPASs at P1, 49 were in the no-root area and 48 in the dentulous area; moreover, 19 showed a degree of root contact (19.6%) without root perforation. All MPASs at P2 were in the no-root area.
Conclusions
Positioning the miniplate head approximately 1 mm lower than the mucogingival junction is highly likely to provide sufficient PH for the P1-MPASs to be placed in the no-root area.
3.Root proximity of the anchoring miniscrews of orthodontic miniplates in the mandibular incisal area: Cone-beam computed tomographic analysis
Do-Min JEONG ; Song Hee OH ; HyeRan CHOO ; Yong-Suk CHOI ; Seong-Hun KIM ; Jin-Suk LEE ; Eui-Hwan HWANG
The Korean Journal of Orthodontics 2021;51(4):231-240
Objective:
This outcome analysis study evaluated the actual positions of the orthodontic miniplate and miniplate anchoring screws (MPASs) and the risk factors affecting adjacent anatomic structures after miniplate placement in the mandibular incisal area.
Methods:
Cone-beam computed tomographic images of 97 orthodontic miniplates and their 194 MPASs (diameter, 1.5 mm; length, 4 mm) in patients whose miniplates provided sufficient clinical stability for orthodontic treatment were retrospectively reviewed. For evaluating the actual positions of the miniplates and analyzing the risk factors, including the effects on adjacent roots, MPAS placement height (PH), placement depth (PD), plate angle (PA), mental fossa angle (MA), and root proximity were assessed using the paired t-test, analysis of variance, and generalized linear model and regression analyses.
Results:
The mean PDs of MPASs at positions 1 (P1) and 2 (P2) were 2.01 mm and 2.23 mm, respectively. PA was significantly higher in the Class III malocclusion group than in the other groups. PH was positively correlated with MA and PD at P1. Of the 97 MPASs at P1, 49 were in the no-root area and 48 in the dentulous area; moreover, 19 showed a degree of root contact (19.6%) without root perforation. All MPASs at P2 were in the no-root area.
Conclusions
Positioning the miniplate head approximately 1 mm lower than the mucogingival junction is highly likely to provide sufficient PH for the P1-MPASs to be placed in the no-root area.
4.Cone-beam computed tomography of mandibular foramen and lingula for mandibular anesthesia
Byeong-Seob AHN ; Song Hee OH ; Chong-Kwan HEO ; Gyu-Tae KIM ; Yong-Suk CHOI ; Eui-Hwan HWANG
Imaging Science in Dentistry 2020;50(2):125-132
Purpose:
The positions of the mandibular foramen (MnF) and the lingula affect the success rate of inferior alveolar nerve block. The objective of this study was to investigate aspects of the MnF and the lingula relevant for mandibular block anesthesia using cone-beam computed tomography (CBCT).
Materials and Methods:
Fifty CBCT scans were collected from a picture archiving and communications system. All scans were taken using an Alphard Vega 3030 (Asahi Roentgen Co. Ltd., Kyoto, Japan). Fifty-eight MnFs of 30 subjects were included in the study. The position of the MnF, the size of the MnF, the position of the lingula, the size of the lingula, and the shape of the lingula were measured and recorded. All data were statistically analyzed at a significance level of p<0.05.
Results:
The position of MnF was 0.1 mm and 0.8 mm below the occlusal plane in males and females, respectively. The horizontal position of the MnF was slightly anterior to the center of the ramus in males and in the center in females (p<0.05). The vertical position of the MnF was lower in females than in males (p<0.05). The MnF was an oval shape with a longer anteroposterior dimension. The height of the lingula was 9.3 mm in males and 8.2 mm in females. The nodular type was the most common shape of the lingula, followed by the triangular, truncated, and assimilated types.
Conclusion
CBCT provided useful information about the MnF and lingula. This information could improve the success rate of mandibular blocks.
5.Diagnostic considerations in central odontogenic fibroma of the maxilla: 2 case reports
Yu Kyeong SEO ; Ju Hee KANG ; Sae Rom LEE ; Yong Suk CHOI ; Eui Hwan HWANG ; Song Hee OH
Imaging Science in Dentistry 2019;49(3):229-234
Central odontogenic fibroma (COF) is defined as a fibroblastic odontogenic tumor characterized by varying density of the tooth epithelium. It is an extremely rare benign neoplasm that occurs in the maxilla and the mandible; only a few reports of COF are available in the literature. Diagnosis of the lesion based only on the radiological features of COF is difficult due to variation in the findings regarding this condition. This report describes 2 clinical cases of middle-aged women with COF. Clinical examination revealed palatal mucosal depression; additionally, oral examination, as well as panoramic radiographs, intraoral radiographs, and computed tomography scans, revealed severe root resorption. This report highlights the clinical and radiological imaging features of COF, with the goal of enabling straightforward differential diagnosis of the lesion by the clinician and thereby appropriate treatment of the patient.
Depression
;
Diagnosis
;
Diagnosis, Differential
;
Diagnosis, Oral
;
Epithelium
;
Female
;
Fibroblasts
;
Fibroma
;
Humans
;
Mandible
;
Maxilla
;
Odontogenic Tumors
;
Root Resorption
;
Tooth
6.Power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow: A technical report
Song Hee OH ; Yu Kyeong SEO ; Gyu Tae KIM ; Yong Suk CHOI ; Eui Hwan HWANG
Imaging Science in Dentistry 2019;49(4):301-306
PURPOSE: This report presents a procedure for performing power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow and illustrates its application to practical patient cases.MATERIALS AND METHODS: The salivary gland was scanned using ultrasound equipment (GE LOGIQ5 Expert® device; GE Medical Systems, Milwaukee, WI, USA) to identify pathological findings related to the patient's chief complaint. To identify the orifice of the main duct, it should be cannulated using a lacrimal dilator. After inserting the catheter into the cannulated main duct, the position of the catheter within the duct was confirmed by ultrasound. A contrast agent was injected until the patient felt fullness, and ultrasound (B-mode) was used to confirm whether the contrast agent filled the main canal and secondary and tertiary ducts. Then, power Doppler ultrasound was performed to determine whether the salivary gland had increased blood flow.RESULTS: In 2 cases in this report, a power Doppler ultrasound scan showed a significant increase in blood flow after contrast medium injection, which was not observed on a preoperative scan.CONCLUSION: Power Doppler ultrasound was found to be a simple, safe, and effective tool for real-time sialography monitoring.
Catheters
;
Humans
;
Salivary Glands
;
Sialography
;
Ultrasonography
;
Vasodilation
7.Analysis of Herbal Medicine Prescriptions for Patients in An Academic Korean Medical Hospital: A Cross Sectional Study of Electronic Medical Records (2010-2013).
Byung-Wook LEE ; Hyeon-Yeop LEE ; Kwang-Ho HEO ; Hyun-Woo CHO ; Man-Suk HWANG ; In HEO ; Byung-Cheul SHIN ; Eui-Hyoung HWANG
Chinese journal of integrative medicine 2018;24(6):467-473
OBJECTIVETo obtain fundamental information for the standardization of herbal medicine in Korea.
METHODSWe analyzed the herbal medicine prescription data of patients at the Pusan National University Korean Medicine Hospital from March 2010 to February 2013. We used the Dongui-Bogam (Dong Yi Bao Jian) to classify prescribed herbal medicines.
RESULTSThe study revealed that the most frequently prescribed herbal medicine was 'Liuwei Dihuang Pill (LWDHP, )' which was used for invigorating 'Shen (Kidndy)-yin'. 'LWDHP' was most frequently prescribed to male patients aged 50-59, 60-69, 70-79 and 80-89 years, and 'Xionggui Tiaoxue Decoction (XGTXD, )' was most frequently prescribed to female patients aged 30-39 and 40-49 years. According to the International Classification of Diseases (ICD) codes, 'Diseases of the musculoskeletal system and connective tissue' showed the highest prevalence. 'LWDHP' and 'XGTXD' was the most frequently prescribed in categories 5 and 3, respectively. Based on the percentage of prescriptions for each sex, 'Ziyin Jianghuo Decoction ()' was prescribed to mainly male patients, and 'XGTXD' with 'Guima Geban Decoction ()' were prescribed to mainly female patients.
CONCLUSIONThis study analysis successfully determined the frequency of a variety of herbal medicines, and many restorative herbal medicines were identified and frequently administered.
Adult ; Aged ; Cross-Sectional Studies ; Drug Prescriptions ; Electronic Health Records ; Female ; Herbal Medicine ; Hospitals ; Humans ; Male ; Medicine, Korean Traditional ; Middle Aged ; Phytotherapy ; Republic of Korea
8.Unusual malignant neoplasms occurring around dental implants: A report of 2 cases
Song Hee OH ; Ju Hee KANG ; Yu Kyeong SEO ; Sae Rom LEE ; Yong Suk CHOI ; Eui Hwan HWANG
Imaging Science in Dentistry 2018;48(1):59-65
Osseointegrated implants are now commonplace in contemporary dentistry. However, a number of complications can occur around dental implants, including peri-implantitis, maxillary sinusitis, osteomyelitis, and neoplasms. There have been several reports of a malignant neoplasm occurring adjacent to a dental implant. In this report, we describe 2 such cases. One case was that of a 75-year-old man with no previous history of malignant disease who developed a solitary plasmacytoma around a dental implant in the left posterior mandible, and the other was that of a 43-year-old man who was diagnosed with squamous cell carcinoma adjacent to a dental implant in the right posterior mandible. Our experiences with these 2 cases suggest the possibility of a relationship between implant treatment and an inflammatory cofactor that might increase the risk of development of a malignant neoplasm.
Adult
;
Aged
;
Carcinoma, Squamous Cell
;
Dental Implants
;
Dentistry
;
Humans
;
Mandible
;
Maxillary Sinus
;
Maxillary Sinusitis
;
Mouth Neoplasms
;
Osteomyelitis
;
Peri-Implantitis
;
Plasmacytoma
9.Linear accuracy of cone-beam computed tomography and a 3-dimensional facial scanning system: An anthropomorphic phantom study
Song Hee OH ; Ju Hee KANG ; Yu Kyeong SEO ; Sae Rom LEE ; Hwa Young CHOI ; Yong Suk CHOI ; Eui Hwan HWANG
Imaging Science in Dentistry 2018;48(2):111-119
PURPOSE: This study was conducted to evaluate the accuracy of linear measurements of 3-dimensional (3D) images generated by cone-beam computed tomography (CBCT) and facial scanning systems, and to assess the effect of scanning parameters, such as CBCT exposure settings, on image quality. MATERIALS AND METHODS: CBCT and facial scanning images of an anthropomorphic phantom showing 13 soft-tissue anatomical landmarks were used in the study. The distances between the anatomical landmarks on the phantom were measured to obtain a reference for evaluating the accuracy of the 3D facial soft-tissue images. The distances between the 3D image landmarks were measured using a 3D distance measurement tool. The effect of scanning parameters on CBCT image quality was evaluated by visually comparing images acquired under different exposure conditions, but at a constant threshold. RESULTS: Comparison of the repeated direct phantom and image-based measurements revealed good reproducibility. There were no significant differences between the direct phantom and image-based measurements of the CBCT surface volume-rendered images. Five of the 15 measurements of the 3D facial scans were found to be significantly different from their corresponding direct phantom measurements (P < .05). The quality of the CBCT surface volume-rendered images acquired at a constant threshold varied across different exposure conditions. CONCLUSION: These results proved that existing 3D imaging techniques were satisfactorily accurate for clinical applications, and that optimizing the variables that affected image quality, such as the exposure parameters, was critical for image acquisition.
Anthropometry
;
Cone-Beam Computed Tomography
;
Dimensional Measurement Accuracy
;
Imaging, Three-Dimensional
10.Volumetric accuracy of cone-beam computed tomography.
Cheol Woo PARK ; Jin ho KIM ; Yu Kyeong SEO ; Sae Rom LEE ; Ju Hee KANG ; Song Hee OH ; Gyu Tae KIM ; Yong Suk CHOI ; Eui Hwan HWANG
Imaging Science in Dentistry 2017;47(3):165-174
PURPOSE: This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. MATERIALS AND METHODS: Four geometric objects (cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The objects consisted of Teflon-perfluoroalkoxy embedded in a hydrocolloid matrix (Dupli-Coe-Loid TM; GC America Inc., Alsip, IL, USA), encased in an acrylic resin cylinder assembly. An Alphard Vega Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) was used to acquire CBCT images. OnDemand 3D (CyberMed Inc., Seoul, Korea) software was used for object segmentation and image analysis. The accuracy was expressed by the volume error (VE). The VE was calculated under 3 different exposure settings. The measured volumes of the objects were compared to the true volumes for statistical analysis. RESULTS: The mean VE ranged from −4.47% to 2.35%. There was no significant relationship between an object's shape and the VE. A significant correlation was found between the distance of the object to the center of the image and the VE. Tube voltage affected the volume measurements and the VE, but tube current did not. CONCLUSION: The evaluated CBCT device provided satisfactory volume measurements. To assess volume measurements, it might be sufficient to use serial scans with a high resolution, but a low dose. This information may provide useful guidance for assessing volume measurements.
Americas
;
Colloids
;
Cone-Beam Computed Tomography*
;
Imaging, Three-Dimensional
;
Seoul

Result Analysis
Print
Save
E-mail