2.Revision and prospect of "Standards for indoor air quality(GB/T 18883-2022)" in China.
Chinese Journal of Preventive Medicine 2023;57(11):1725-1728
The formulation and revision of the detection methods of indoor air quality standards is an important, rigorous and delicate endeavor. The standards for indoor air quality (GB/T 18883-2022) were issued by the State Administration of Market Regulation and the Standardization Administration on July 11, 2022, and implemented on February 1, 2023 by replacing indoor air quality standards (GB/T 18883-2002). The revised standard specifies hygienic requirements for physical, chemical, biological and radioactive indicators in indoor air and the corresponding test methods. This article interpreted the revision background, drafting principles, main indicators and methods, as well as the revision basis of the standards. Recommendations for the implementation of the standards are also proposed.
Humans
;
Air Pollution, Indoor/prevention & control*
;
Environmental Monitoring
;
Reference Standards
;
China
;
Air Pollutants/analysis*
3.Study on revision of standard limits for benzene in"Standards for indoor air quality(GB/T 18883-2022)"in China.
Guo Min CHEN ; Tian Tian LI ; Yan Jun DU ; Shuai JIANG ; Dao Kui FANG ; Xiao Heng LI ; Ning LIU ; Shu Yuan YU
Chinese Journal of Preventive Medicine 2023;57(11):1752-1755
Benzene, as a major indoor pollutant, has received widespread attention. In order to better control indoor benzene pollution and protect people's health, the limit value of benzene in the"Standards for indoor air quality (GB/T 18883-2022)'' was reduced from 0.11 mg/m3 to 0.03 mg/m3. This study reviewed and discussed the relevant technical contents of the determination of benzene limit value, including the exposure status of benzene, health effects, and derivation of the limit value. It also proposed prospects for the future direction of formulating indoor air benzene standards.
Humans
;
Air Pollution, Indoor/prevention & control*
;
Benzene/analysis*
;
Air Pollutants/analysis*
;
Environmental Pollutants
;
China
;
Environmental Monitoring
4.Study on formulation and revision of standard limits for inhalable particulate matter (PM10) and fine particulate matter (PM2.5) in "Standards for indoor air quality(GB/T 18883-2022)" in China.
Ya wei LI ; Cheng Cheng LI ; Chen CHEN ; Zheng LI ; Chen CHEN ; Jian Long FANG ; Tian Tian LI ; Feng ZHAO ; Xiao Ming SHI
Chinese Journal of Preventive Medicine 2023;57(11):1761-1765
The pollution and health effects of indoor inhalable particulate matter (PM10) and fine particulate matter (PM2.5) are increasingly receiving public attention. The"Standards for indoor air quality (GB/T 18883-2022)"has revised the standard limit for PM10 and added the standard limit for PM2.5. This study analyzed and interpreted the relevant technical contents of the revision of the standard limits for two indicators, including the exposure status, health effects, and the basis for the determination of the limit value. It also proposed prospects for the future development and revision of standard limits for indoor particulate matters.
Humans
;
Particulate Matter/analysis*
;
Air Pollution, Indoor
;
Air Pollutants/analysis*
;
Particle Size
;
Environmental Monitoring
;
China
;
Air Pollution
5.Study on formulation and revision of standard limits for total bacteria count in "Standards for indoor air quality(GB/T 18883-2022)" in China.
Cheng DING ; Xia LI ; Song TANG
Chinese Journal of Preventive Medicine 2023;57(11):1770-1772
The total bacteria count has been attracting attention as an important pollutant in indoor air, and its standard limit was tightened to 1500 CFU/m3 in "Standards for indoor air quality (GB/T 18883-2022)".The technical contents related to the determination of the indoor air standard limits for total bacteria count were analyzed and studied, including the environmental existence level, exposure status, the health effects and the derivation of the limit value. It also proposed prospects for the future development and revision of quality standards for total bacteria count in indoor air.
Humans
;
Air Pollution, Indoor
;
China
;
Environmental Pollutants
;
Bacteria
;
Environmental Monitoring
;
Air Pollutants
6.The Link between Exposure to Phthalates and Type 2 Diabetes Mellitus: A Study Based on NHANES Data and Bioinformatic Analysis.
Xue Kui LIU ; Shan Wen SI ; Yan YE ; Jia Yi LI ; He He LYU ; Ya Mei MA ; Cai Yan ZOU ; Hao Jie SUN ; Lei XUE ; Wei XU ; Hou Fa GENG ; Jun LIANG
Biomedical and Environmental Sciences 2023;36(9):892-896
7.Microplastics pollution in the Yellow River basin: current status and control strategy.
Zan LIU ; Zhongliang SUN ; Liang SHI ; Qiang WANG
Chinese Journal of Biotechnology 2023;39(2):488-499
Microplastics pollution has attracted worldwide attention. Compared with the status quo of microplastics pollution in marine environment and other major rivers and lakes, the relevant data of the Yellow River basin is relatively inadequate. The abundance, types, and spatial distribution characteristics of microplastic pollution in the sediments and surface water of the Yellow River basin were reviewed. Meanwhile, the status of microplastic pollution in the national central city and Yellow River Delta wetland was discussed, and the corresponding prevention and control measures were put forward. The results showed that the spatial distribution of microplastics pollution in sediments and surface water of the Yellow River basin increased from upstream to downstream, especially in the Yellow River Delta wetland. There are obvious differences between the types of microplastics in sediment and surface water in the Yellow River basin, which is mainly related to the materials of microplastics. Compared with similar regions in China, the microplastics pollution levels in national key cities and national wetland parks in the Yellow River basin are in the medium to high degree, which should be taken seriously. Plastics exposure through various ways will cause serious impact on aquaculture and human health in the Yellow River beach area. To control microplastic pollution in the Yellow River basin, it is necessary to improve the relevant production standards, laws and regulations, and improve the capacity of biodegradable microplastics and the degradation capacity of plastic wastes.
Humans
;
Microplastics
;
Plastics
;
Water Pollutants, Chemical/analysis*
;
Environmental Monitoring/methods*
;
Water
;
China
8.Quantitative risk assessment of occupational exposure to PCDD/Fs in the waste incineration industry.
Jin Tong HE ; Liang Jiao QU ; Shi Biao SU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(3):213-216
Objective: To analyze the level of PCDD/Fs exposure of occupational workers in the waste incineration industry and explore the risk of occupational exposure. Methods: In September 2021, literature on environmental PCDD/Fs exposure in waste incineration plants published from the establishment of the database to February 10, 2021 was retrieved from CNKI database. A total of 1365 literatures were retrieved, and 7 met the criteria for inclusion. The US Environmental Protection Agency (EPA) inhalation risk model was used to assess and analyze carcinogenic and non-carcinogenic risks of PCDD/Fs exposure among occupational workers in the waste incineration industry. Results: A total of 86 sampling sites were included in incineration plants in 7 regions. The study of Wuhan area showed that the concentration of working environment near the waste incinerator in the same factory was the highest, followed by the rest and office area in the factory. The concentration of PCDD/Fs in waste incinerators was the highest in Southwest China (4880.00-24880.00 pg TEQ/m(3)), and the lowest in Shenzhen (0.02-0.44 pg TEQ/m(3)). According to the cancer risk assessment, with the increase of exposure years, the risk of cancer increased. The highest risk of cancer was found in the waste incineration plants in Southwest China. When the exposure period was 1 year, the risk was moderate (22.40×10(-6)-114.20×10(-6)). When the exposure time was more than 5 years, the risk of cancer was high. In Jinan, workers working near the incinerator had a moderate risk of cancer after five years of exposure. In Zhejiang, workers were at medium risk of cancer after exposure for more than 20 years. Workers in Wuhan, Shanghai, Zhejiang Province, Shenzhen and the Pearl River Delta were still at low risk of cancer after 40 years of occupational exposure. HQ>1 of workers working near the waste incinerators in Jinan, Zhejiang Province and Southwest China, and the qualitative evaluation results showed that the non-carcinogenic risk was unacceptable. Conclusion: There are great differences in PCDD/Fs of occupational exposure in waste incineration industry, and the occupational exposure exceeding the occupational exposure limit has higher carcinogenic and non carcinogenic risks.
Humans
;
Dibenzofurans
;
Polychlorinated Dibenzodioxins/analysis*
;
Air Pollutants/analysis*
;
Incineration
;
Dibenzofurans, Polychlorinated/analysis*
;
China/epidemiology*
;
Benzofurans
;
Occupational Exposure/analysis*
;
Carcinogens
;
Risk Assessment
;
Neoplasms
;
Environmental Monitoring/methods*
9.Revision and prospect of "Standards for indoor air quality(GB/T 18883-2022)" in China.
Chinese Journal of Preventive Medicine 2023;57(11):1725-1728
The formulation and revision of the detection methods of indoor air quality standards is an important, rigorous and delicate endeavor. The standards for indoor air quality (GB/T 18883-2022) were issued by the State Administration of Market Regulation and the Standardization Administration on July 11, 2022, and implemented on February 1, 2023 by replacing indoor air quality standards (GB/T 18883-2002). The revised standard specifies hygienic requirements for physical, chemical, biological and radioactive indicators in indoor air and the corresponding test methods. This article interpreted the revision background, drafting principles, main indicators and methods, as well as the revision basis of the standards. Recommendations for the implementation of the standards are also proposed.
Humans
;
Air Pollution, Indoor/prevention & control*
;
Environmental Monitoring
;
Reference Standards
;
China
;
Air Pollutants/analysis*
10.Study on revision of standard limits for benzene in"Standards for indoor air quality(GB/T 18883-2022)"in China.
Guo Min CHEN ; Tian Tian LI ; Yan Jun DU ; Shuai JIANG ; Dao Kui FANG ; Xiao Heng LI ; Ning LIU ; Shu Yuan YU
Chinese Journal of Preventive Medicine 2023;57(11):1752-1755
Benzene, as a major indoor pollutant, has received widespread attention. In order to better control indoor benzene pollution and protect people's health, the limit value of benzene in the"Standards for indoor air quality (GB/T 18883-2022)'' was reduced from 0.11 mg/m3 to 0.03 mg/m3. This study reviewed and discussed the relevant technical contents of the determination of benzene limit value, including the exposure status of benzene, health effects, and derivation of the limit value. It also proposed prospects for the future direction of formulating indoor air benzene standards.
Humans
;
Air Pollution, Indoor/prevention & control*
;
Benzene/analysis*
;
Air Pollutants/analysis*
;
Environmental Pollutants
;
China
;
Environmental Monitoring

Result Analysis
Print
Save
E-mail