1.Application of a digital chylous plasma assessment device in the determination of chylous plasma
Lingyue GUO ; Caina LI ; Hongyan GAO ; Wei WEI ; Ping ZHANG ; Yan LIU ; Yajie WANG ; Weidong HE
Chinese Journal of Blood Transfusion 2025;38(9):1236-1241
Objective: To develop a simple digital chylous plasma device and validate its ability to accurately, standardly, and non-destructively determine chylous plasma in blood banks and clinical transfusions in hospitals. Methods: A digital chylous plasma assessment device was designed and manufactured. This device was used to measure the chylous degrees of chylous plasma samples before freezing, after freeze-thawing, before viral inactivation, and after viral inactivation. The measured chylosity index values were categorized according to the requirements specified in Appendix A of the Chinese national standard GB 18469-2001 "Quality Requirements for Whole Blood and Blood Components". This process established a digital standard for chylous plasma, enabling the identification of severe, moderate and mild chylous plasma, and non-chylous plasma. Results: The initial simple product of the digital chylous assessment device was successfully designed and manufactured. There was no significant difference in the degree of chylous plasma between pre-freezing 468.11±217.73 lux and post-thawing 538.91±273.39 lux of chylous plasma (P>0.05), or between pre-viral inactivation 858.33±387.79 lux and post-viral inactivation 928.33±166.51 lux of chylous plasma (P>0.05). The median of chylous degree values for plasma chylous index grades 0 to 6 were 45 lux, 250 lux, 620 lux, 835 lux, 1 130 lux, 1 390 lux, and 1 700 lux, respectively. The defined cutoff values/ranges for the chylous degree values corresponding to plasma chylous index grade 0 to 6 were ≤125 lux, 126-465 lux, 466-740 lux, 741-1 000 lux, 1 001-1 233 lux, 1 234-1 560 lux, and ≥1 561 lux. Conclusion: This study successfully developed the initial product of the digital chylous device and established digital standards for classifying chylous plasma. The device demonstrates the potential to meet the needs for assessment of chylous plasma in both blood banks and clinical transfusions in hospitals, thereby promoting the development and application of standardized, non-destructive chylous plasma assessment technology.
2.miR-185-5p alleviates the inflammatory response of acute gouty arthritis by inhibiting of IL-1β.
Nan HOU ; Xianghui MA ; Wei ZHOU ; Min YUAN ; Liming XU ; Huanxia SUN ; Yifan LIU ; Lining LIU ; Yanjun SHI ; Chunxian LI ; Yanfa FU
Chinese Journal of Cellular and Molecular Immunology 2024;40(1):51-57
Objective To investigate the relationship between interleukin-1β (IL-1β) and miR-185-5p in the process of joint injury in acute gouty arthritis (AGA). Methods The serum miR-185-5p levels of 89 AGA patients and 91 healthy volunteers were detected by real-time quantitative PCR. The correlation between miR-185-5p expression level and VAS score or IL-1β expression level was evaluated by Pearson correlation coefficient method. Receiver operating characteristic (ROC) curve was used to evaluate the diagnostic value of miR-185-5p in AGA. THP-1 cells were induced by sodium urate (MSU) to construct an in vitro acute gouty inflammatory cell model. After the expression level of miR-185-5p in THP-1 cells was upregulated or downregulated by transfection of miR-185-5p mimics or inhibitors in vitro, inflammatory cytokines of THP-1 cells, such as IL-1β, IL-8 and tumor necrosis factor α (TNF-α), were detected by ELISA. The luciferase reporter gene assay was used to determine the interaction between miR-185-5p and the 3'-UTR of IL-1β. Results Compared with the healthy control group, the expression level of serum miR-185-5p in AGA patients was significantly reduced. The level of serum miR-185-5p was negatively correlated with VAS score and IL-1β expression level. The area under the curve (AUC) was 0.905, the sensitivity was 80.17% and the specificity was 83.52%. Down-regulation of miR-185-5p significantly promoted the expression of IL-1β, IL-8 and tumor necrosis factor (TNF-α), while overexpression of miR-185-5p showed the opposite results. Luciferase reporter gene assay showed that IL-1β was the target gene of miR-185-5p, and miR-185-5p negatively regulated the expression of IL-1β. Conclusion miR-185-5p alleviates the inflammatory response in AGA by inhibiting IL-1β.
Humans
;
3' Untranslated Regions
;
Arthritis, Gouty/genetics*
;
Interleukin-1beta/genetics*
;
Interleukin-8
;
Luciferases
;
MicroRNAs/genetics*
;
Tumor Necrosis Factor-alpha
3.Historical Evolution and Key Information Research on Pediatric Famous Classical Formula Yigongsan
Jiangmin SU ; Jun ZHANG ; Cong GUO ; Anyi ZHAO ; Liang JIANG ; Heng ZHANG ; Jipeng DI ; Sha CHEN ; Li LIU ; Yan LIU ; An LIU
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(7):205-214
Yigongsan is derived from Xiaoer Yaozheng Zhijue written by QIAN Yi in the Northern Song dynasty, which is the No. 3 formula in the Catalogue of Ancient Famous Classical Formulas(The Second Batch of Pediatrics) released by the National Administration of Traditional Chinese Medicine(TCM) in September 2022, and it can be developed as a class 3.1 new TCM drug. By referring to ancient medical books and modern literature, this study conducted herbal textual research on Yigongsan from five aspects, including historical evolution, origin and processing, dosage conversion, usage and preparation methods, and functional application, then formed the key information table of this formula, in order to provide reference for the development of reference samples and preparations of Yigongsan. Based on the results of the study, it is recommended that Panax ginseng should be removed the basal part of stem(rhizoma), Poria cocos should be removed the peel, Citrus reticulata should be cut into shreds and Glycyrrhiza uralensis should be used. According to 4.13 g/Qian(钱), 1 g/slice for ginger, 3 g for each jujube and 300 mL/Zhan(盏), the doses of Ginseng Radix, Poria, Atractylodis Macrocephalae Rhizoma, Glycyrrhizae Radix et Rhizoma, Citri Reticulatae Pericarpium, Zingiberis Rhizoma Recens, Jujubae Fructus were 1.652, 1.652, 1.652, 1.652, 1.652, 5, 6 g, and the total amount was 19.26 g. The decocting method was to crush the medicinal materials into fine powder with 50-80 mesh, add 300 mL of water and decoct to 210 mL for each dose, then remove the dregs and take it warmly. This formula was recorded in ancient books as the main treatment for the cold-deficiency of spleen and stomach, and Qi stagnation in children with vomiting and diarrhea and lack of appetite. It has been flexibly applied by later generations of physicians, and is often used to treat anorexia, inflammation of the digestive tract, diarrhea and other diseases in children.
4.Analysis of Inhibitory Effect of Berberine Compounds on Acetylcholinesterase and Blood-brain Barrier Permeability
Fulu PAN ; Yang LIU ; Huining LIU ; Shuang YU ; Xueyan LI ; Xinyu WANG ; Dongying QI ; Xiaoyu CHAI ; Qianqian WANG ; Zirong YI ; Yanli PAN
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(9):116-124
ObjectiveTo examine the inhibitory effects of berberine compounds, including columbamine, on acetylcholinesterase from the perspectives of drug-target binding affinity and kinetics and explore the blood-brain barrier (BBB) permeability of these compounds in different multi-component backgrounds. MethodThe median inhibitory concentration (IC50) of acetylcholinesterase by berberine compounds including columbamine was measured using the Ellman-modified spectrophotometric method. The binding kinetic parameters (Koff) of these compounds with acetylcholinesterase were determined using the enzyme activity recovery method. A qualitative analysis of the ability of these components to penetrate the BBB and arrive at the brain tissue in diverse multi-component backgrounds (including medicinal herbs and compound formulas) was conducted using ultra performance liquid chromatography-high resolution mass spectrometry (UPLC-HRMS). ResultBerberine compounds, including columbamine, exhibited strong inhibition of acetylcholinesterase, with IC50 values in the nanomolar range. Moreover, they displayed better drug-target binding kinetics characteristics (with smaller Koff values) than the positive control of donepezil hydrochloride (P<0.01), indicating a longer inhibition duration of acetylcholinesterase. Berberine components such as columbamine could penetrate the BBB to arrive at brain tissue in the form of a monomer, as well as in the multi-component backgrounds of Coptis and Phellodendri Chinensis Cortex medicinal extracts and the compound formula Huanglian Jiedutang. ConclusionThese berberine compounds such as columbamine exhibit a strong inhibitory effect on acetylcholinesterase and can arrive at brain tissue in multi-component backgrounds. In the level of pharmacological substance, this supports the clinical efficacy of compound Huanglian Jiedutang in improving Alzheimer's disease, providing data support for elucidating the pharmacological basis of compound Huanglian Jiedutang.
5.Analysis on Components Absorbed into Blood and Cerebrospinal Fluid of Schisandrae Chinensis Fructus Based on Sequential Metabolism
Shuang YU ; Yanli PAN ; Huining LIU ; Xueyan LI ; Xinyu WANG ; Dongying QI ; Fulu PAN ; Qianqian WANG ; Xiaoyu CHAI ; Guopeng WANG ; Tao MA ; Yang LIU
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(3):114-123
ObjectiveTo identify the prototypical components and metabolites absorbed into blood and cerebrospinal fluid of Schisandrae Chinensis Fructus(SCF) based on sequential metabolism combined with liquid chromatography-mass spectrometry. MethodBlood and cerebrospinal fluid samples of integrated metabolism, intestinal metabolism and hepatic metabolism were collected from male SD rats after gavage and in situ intestinal perfusion administration, and ultra-performance liquid chromatography-quadrupole/electrostatic field orbitrap high-resolution mass spectrometry(UPLC Q-Exactive Orbitrap MS) was used to analyze and compare the differences in the spectra of SCF extract, blank plasma, administered plasma, blank cerebrospinal fluid and administered cerebrospinal fluid with ACQUITY UPLC BEH Shield RP18 column(2.1 mm×100 mm, 1.7 µm), the mobile phase was acetonitrile(A)-0.1% formic acid aqueous solution(B) for gradient elution(0-7 min, 95%B; 7-12 min, 95%-35%B; 12-17 min, 35%-15%B; 17-20 min, 15%-12%B; 20-22 min, 12%-5%B; 22-23 min, 5%B; 23-25 min, 5%-95%B; 25-28 min, 95%B). And heated electrospray ionization(HESI) was used with positive and negative ion modes, the scanning range was m/z 100-1 500. The prototypical constituents and their metabolites absorbed into blood and cerebrospinal fluid of SCF were identified according to the retention time, characteristic fragments, molecular formulae and the information of reference substances. ResultA total of 42 chemical components were identified in the extract of SCF, including lignans, flavonoids, amino acids, tannins, and others, of which lignans were the main ones. A total of 27 prototypical components and 14 metabolites were identified in plasma samples from different sites. A total of 15 prototypical components and 9 metabolites were identified in cerebrospinal fluid. The main metabolic reactions involved in the formation of metabolites were mainly demethylation, methylation, demethoxylation and hydroxylation. ConclusionThrough the systematic identification of the prototypical components and metabolites of SCF in rats, it provides data support for further better exploring the material basis of SCF in the treatment of central nervous system diseases.
6.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
7.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
8.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
9.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
10.JIA Yingjie's Experience in the Diagnosis and Treatment of Esophageal Cancer
Dongying LIAO ; Jiayu LIU ; Yue LI
Journal of Zhejiang Chinese Medical University 2024;48(2):170-173
[Objective]To summarize the clinical experience of Professor JIA Yingjie,a renowned traditional Chinese medicine practitioner in the treatment of esophageal cancer.[Methods]Through clinical following up,collect and analyze Professor JIA's understanding of the etiology and pathogenesis of esophageal cancer and related medication,and a case of was attached as evidence.[Results]Professor JIA believes that the pathogenesis of esophageal cancer can be summarized as"phlegm coagulation and Qi stagnation"in the early stage,"primitive deficiency"in the late stage as a whole,"phlegm and blood stasis intermingle,Qi and blood stasis obstruct the diaphragm"in local areas,phlegm,Qi,and blood stasis solidify and poison transform into cancer turbidity,and block and form tumors.Clinical differentiation and treatment should always focus on"Qi",with a particular emphasis on regulating the"Qi mechanism".The lungs,spleen and liver are in sync,and dynamic differentiation and treatment should be carried out based on the characteristics of the patient's tongue and pulse.Medication should emphasize the use of"strengthening the body resistance righting"and"dispelling pathogenic factors"to achieve the dissipation of blood stasis,the elimination of cancer toxins and the opening of the diaphragm.[Conclusion]Based on the characteristics of esophageal cancer and the patient's physical constitution,Professor JIA combines disease and syndrome differentiation in treating esophageal cancer,providing a certain reference value and new path for clinical medication.

Result Analysis
Print
Save
E-mail