1.Application of color doppler flow imaging in the diagnosis of ocular toxocariasis in children
Wei CHEN ; Wenli YANG ; Jinghua LIU ; Dongjun LI ; Ziyang WANG ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Lin SHEN ; Qian LIU
Chinese Journal of Ocular Fundus Diseases 2024;40(1):39-43
Objective:To summarize the characteristics of color doppler flow imaging (CDFI) of ocular toxocariasis (OT) in children.Methods:A retrospective clinical study. From July 2014 to June 2020, 61 OT patients with 61 eyes diagnosed through clinical and laboratory testing in the Department of Ophthalmology of Beijing Tongren Hospital of Capital Medical University were included in the study. There were 45 males with 45 eyes and 16 females with 16 eye (male: female=2.81:1). Age were (6.93±2.50) years. The right eye and left eye were 29 and 32 eyes, respectively. Both eyes of the patient underwent two-dimensional ultrasound and CDFI examination. Two dimensional ultrasound was used to estimate the axial length (AL) of the affected eyes and healthy eyes on the opposite side. Among them, 52 cases were measured for AL using optical biometry and/or A-mode ultrasound. Vitreoretinal surgery was performed within one week after ultrasound examination. Two-dimensional ultrasound was used to observe the morphology of vitreous opacity, its connection to the eyeball wall, and whether posterior vitreous detachment and retinal detachment have occurred. CDFI examination was used to observe the presence of blood flow signals on the pathological membrane. The detection rates of different forms of vitreous opacity and traction retinal detachment were calculated. The location of proliferative lesions in the eye was analyzed. Paired t-test was performed to compare the AL of the affected eye and the healthy eye on the opposite side. Perform Kappa consistency test on the location of proliferative lesions was used during CDFI examination and vitreoretinal surgery. Results:All affected eyes have varying degrees of vitreous opacity. Among them, 23 eyes (37.7%, 23/61) showed typical "Christmas tree" like turbidity; 27 eyes (44.3%, 27/61) had clustered and striped echoes; 9 eyes (14.8%, 9/61) had weak punctate and strip echoes. Two eyes (3.3%, 2/61) showed a large amount of dense punctate and strip-shaped echoes. There were 50 eyes (82.0%, 50/61) with traction retinal detachment, of which 46 eyes (92.0%, 46/50) had visible blood flow signals on the detached retina, and the remaining 4 eyes (8.0%, 4/50) had no blood flow signals. During CDFI and surgery, there were 5 (8.2%, 5/61) and 4 (6.6%, 4/61) eyes with visible proliferative lesions in the periphery, respectively; 18 (29.5%, 18/61) and 14 (23.0%, 14/61) eyes were distributed in the posterior pole, respectively; there were 38 (62.3%, 38/61) and 43 (70.5%, 43/61) eyes with both peripheral and posterior polar regions, respectively. The consistency between CDFI and surgery in detecting the location of proliferative lesions was good ( κ=0.832, 95% confidence interval 0.691-0.973, P<0.001). The two-dimensional ultrasound measurement results showed that the AL of the affected eye was shorter than that of the contralateral healthy eye in 46 cases (75.4%, 46/61). Among the 52 patients who underwent AL biometry, the AL of the affected eye was shorter than that of the contralateral healthy eye by (0.63±0.68) mm, and the difference was statistically significant ( t=-6.738, P<0.05). Conclusions:CDFI can clearly display various intraocular lesions (vitreous opacity and traction retinal detachment) and eyeball sizes in children with OT. Vitreous opacity is often manifested as "Christmas tree" like, clustered, strip-shaped.
2.Analysis of the feasibility of measurements and characteristics of intraocular lens tilt using swept-source optical coherence tomography biometer
Qi ZHAO ; Wenli YANG ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Yifeng LI ; Rui CUI ; Lin SHEN ; Lei LI ; Junfang XIAN
Chinese Journal of Experimental Ophthalmology 2023;41(6):554-560
Objective:To evaluate the feasibility of measurement and characteristics of intraocular lens (IOL) tilt using the swept-source optical coherence tomography (SS-OCT) biometer (IOLMaster 700) and to explore its potentially relevant parameters.Methods:A cross-sectional study was conducted.Two hundred and forty-two eyes (119 right eyes, 123 left eyes) of 185 patients after phacoemulsification and IOL implantation were included in Beijing Tongren Hospital from July to September 2018.The IOL position, angle κ, angle α, corneal curvature, anterior chamber depth (ACD), pupil diameter (PD), and axial length (AL) were obtained by IOLMaster 700, and the IOL tilt direction and magnitude were calculated.The within-subject standard deviation and intraclass correlation coefficient were used to evaluate the repeatability of three IOL tilt measurements.Binocular symmetry of IOL tilt and the correlation between IOL tilt and different influencing factors were evaluated by Pearson linear correlation analysis or Spearman rank correlation analysis.Influencing factors for IOL tilt were assessed by multiple linear regression analysis.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Beijing Tongren Hospital, Capital Medical University (No.TRECKY2018-049). Patients were informed of the purpose and methods of this study and signed the written informed consent.Results:The repeatability of IOL tilt measurements was excellent with a within-subject standard deviation of 5.16° for IOL tilt direction and 0.13° for IOL tilt magnitude.IOL tilt was mirror symmetric in both eyes.The IOL tilt direction in right eyes ranged from -89.60° to 87.53° with a mean of (18.85±29.65)°, and the tilt magnitude ranged from 1.32° to 7.05° with a mean of (4.16±1.26)°.The IOL tilt direction in left eyes ranged from -84.30° to 89.44° with a mean of (21.17±32.38)°, and the tilt magnitude ranged from 0.58° to 7.40° with a mean of (3.80±1.31)°.There were moderate and weak positive correlations of IOL tilt direction and tilt magnitude between both eyes ( r=0.473, P<0.001; r=0.335, P=0.011). IOL tilt magnitude was weakly positively correlated with angle α and IOL diopter ( rs=0.272, P=0.003; r=0.285, P=0.002), and was weakly negatively correlated with ACD, PD and AL ( r=-0.303, P=0.001; r=-0.233, P=0.011; rs=-0.331, P<0.001). In backward stepwise regression analysis, the regression equation of IOL tilt magnitude, angle α, ACD, PD, AL and IOL diopter in multiple linear regression analysis was as follows: IOL tilt magnitude=10.503+ 1.456×angle α-0.532×ACD-0.196×AL ( R2=0.400; F=8.588, P<0.001). Conclusions:The SS-OCT biometer can be an effective method to assess IOL tilt.IOL tilt is mirror symmetric between the right eyes and left eyes.
3.Effectiveness and security of anisodine hydrobromide tablets in treating nonarteritic anterior ischemic optic neuropathy: a Chinese multicenter nonrandomized controlled study
Mo YANG ; Honglu SONG ; Huanfen ZHOU ; Mengying LAI ; Quangang XU ; Mingming SUN ; Ke FAN ; Hongpei CUI ; Haiyan WANG ; Xin JIN ; Chuanbin SUN ; Qing XIAO ; Ying WANG ; Zide ZHAO ; Minglian ZHANG ; Yongye CHANG ; Mengping CHEN ; Zhanxing SHEN ; Hui YANG ; Xiaoyu XU ; Zhiqing LI ; Dongjun XING ; Yu DONG ; Jinrun YANG ; Qian REN ; Li LI ; Wenfang ZHANG ; Li SUN ; Zhengpei ZHANG ; Suyan LI ; Danyan LIU ; Nalei ZHOU ; Nali LUO ; Yadong LIU ; Shihui WEI
Chinese Journal of Experimental Ophthalmology 2023;41(7):646-653
Objective:To evaluate the efficacy and safety of oral anisodine hydrobromide tablets in the treatment of nonarteritic anterior ischemic optic neuropathy (NAION).Methods:A multicenter nonrandomized controlled trial was conducted.A total of 282 acute NAION patients (282 eyes) were recruited from 16 hospitals in China from July 2020 to May 2021.Patients were divided into two groups according to treatment methods, which were control group (124 cases, 124 eyes) receiving regular treatment including citicoline sodium plus Ginkgo biloba leaf liquid extract or Ginkgo biloba leaf extract tablets plus mecobalamin, and experimental group (158 cases, 158 eyes) receiving treatment in control group plus oral anisodine hydrobromide tablets 1 mg, twice daily for 2 to 3 months.Best corrected visual acuity (BCVA), visual field index (VFI), peripapillary retinal nerve fiber layer (pRNFL) and radial peripapillary capillary vessel density (RPC) were assessed at 1, 2, 3, and 6 months after enrollment using the standard decimal visual acuity chart, 750i Humphery visual field analyzer, Cirrus HD-OCT 4000/Cirrus HD-OCT 5000, RTVue-XR optical coherence tomography respectively.The primary outcomes were BCVA and VFI, and the secondary outcomes were pRNFL, RPC, and the side effects during the follow-up.The study adhered to the Declaration of Helsinki.All patients were fully informed about the treatment and purpose of this study and voluntarily signed the informed consent form.The study protocol was approved by Chinese PLA General Hospital (No.S2020-021-01). Results:In all, 242 patients (242 eyes) completed the follow-up of BCVA, and 98 patients (98 eyes) completed the VFI follow-up.In terms of visual function, BCVA and VFI improved significantly over time in the two groups, and BCVA and VFI were better in experimental group than in control group at various follow-up time points (all at P<0.05). In terms of structure, pRNFL gradually decreased in both groups with the extension of treatment, and pRNFL was significanthy thinner in experimental group than in control group at various follow-up time points (all at P<0.05). There was no significant difference in RPC between the two groups at the last follow-up ( P>0.05). There were two cases with side effects and one case was discontinued due to side effects 25 days after enrollment. Conclusions:Oral anisodine hydrobromide can improve visual acuity and visual field in NAION and accelerate the regression of optic disc edema, with good safety.
4.Ultrasonographic features of adenoma of the nonpigmented ciliary epithelium
Dongjun LI ; Wenli YANG ; Wenbin WEI ; Xiaolin XU ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Lin SHEN ; Qian LIU ; Chuanchuan WEI
Chinese Journal of Ocular Fundus Diseases 2022;38(3):191-196
Objective:To analyze the ultrasonographic features of adenoma of the nonpigmented ciliary epithelium (ANPCE).Methods:A retrospective series of case studies. From January 2014 to October 2021, 31 patients (31 eyes) with ANPCE (ANPCE group) were diagnosed in the eye center of Beijing Tongren Eye Center of Beijing Tongren Hospital, Capital Medical University, and 17 patients (17 eyes) with ciliary body melanoma (control group) diagnosed at the same time were selected as the control group. There was no significant difference in age ( t=-0.564) and sex composition ratio ( χ 2=0.182) between the two groups ( P=0.576, 0.670). All patients underwent ultrasound biomicroscopy to obtain the measurement parameters: tumor height, maximum basal diameter, maximum diameter, ratio of maximum diameter to basal diameter and ratio of maximum diameter to height; tumor location, shape, internal echogenicity intensity, echogenicity uniformity, degree of sound attenuation, invasion of iris, anterior displacement of the iris, lens subluxation were observed. The measurement parameters and observation indexes of the two groups were compared by independent sample t-test and χ 2 test. Receiver operating characteristic (ROC) curve was drawn, area under the ROC curve (AUC) was determined, and parameter indicators with differential diagnosis value were screened. Results:The maximum diameter, height, maximum basal diameter, ratio of the maximum diameter to the maximum basal diameter, and the ratio of the maximum diameter to the height of the tumors in the ANPCE group and the control group were 5.64±0.98 mm, 4.24±0.59 mm, 3.66±0.71 mm, 1.58±0.34, 1.34±0.19 and 7.82±2.03 mm, 4.47±2.44 mm, 7.02±1.96 mm, 1.13±0.16, 2.09±1.06. The maximum diameter, the maximum basal diameter, and the ratio of the maximum diameter to the height of the tumor in the ANPCE group were all smaller than those of the control group, and the ratio of the maximum diameter to the maximum basal diameter was greater than that of the control group, and the differences were statistically significant ( t=-4.159,-6.808, -2.924, 6.257; P<0.05). The tumors in the ANPCE group were mainly spherical (87.1%, 27/31), with no significant acoustic attenuation (77.4%, 24/31), less invading the root iris (77.4%, 24/31), and the tumors were mostly located in the ciliary body coronal (74.2%, 23/31); tumors in the control group were mainly hemispherical (47.1%, 8/17) or spherical (47.1%, 8/17), with significant sound attenuation (76.5%, 13/17), most of the tumors invaded the iris (70.6%, 12/17), and the tumors were mostly located from the pars plana to the coronal (76.5%, 13/17). There were statistically significant differences in the position, shape, sound attenuation degree, and whether it invaded the iris between the two groups of eyes ( χ 2=15.132, 19.767, 13.118, 10.581; P<0.05). The results of ROC curve analysis showed that the ratio of the largest diameter to the largest base diameter, the degree of sound attenuation and the AUC of whether the iris was violated were higher, which were 0.881, 0.769, and 0.740, respectively. Conclusions:Ultrasound biomicroscopy is helpful in the diagnosis and differential diagnosis of ANPCE and ciliary body melanoma. The ratio of maximum diameter to maximum basal diameter, the degree of sound attenuation and whether it invades the root iris are important parameters to distinguish the two tumors.
5.Analysis of ultrasonic diagnostic features of juxtapapillary capillary hemangioma
Yifeng LI ; Wenli YANG ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Rui CUI ; Lin SHEN ; Qian LIU ; Wenbin WEI ; Junfang XIAN
Chinese Journal of Ultrasonography 2021;30(2):161-166
Objective:To discuss the characteristics of ultrasound diagnosis of optic disc capillary hemangioma.Methods:The study analyzed retrospectively 7 cases of optic disc capillary hemangioma diagnosed in the Beijing Tongren Hospital from 2015 to 2018. The size, morphology, internal echo, and secondary changes of the lesion were analyzed during ultrasound examination.Color Doppler flow imaging was used to check the blood flow in the lesion.Results:Pre-optic disc occupying lesions could be detected in the ultrasound images of the 7 cases. Lesion size: average base diameters (5.39±1.90)mm×(4.79±1.28)mm, average height (3.61±1.37)mm. Lesion morphology: 5 cases were round, and 2 cases were irregular. Echo within the lesion: 3 cases had medium echo inside the lesion, and 4 cases had high echo inside the lesion. Internal echo characteristics: 5 cases had uniform echo, and 2 cases had uneven echo. Secondary changes: 6 cases had secondary retinal detachment and vitreous opacity, and 1 cases was accompanied by retinal hemangioma in other parts. In all cases, blood flow signals could be detected inside the space-occupying lesions, which were in the form of branches, stripes or spots, and the blood flow spectrum showed a parallel spectrum of arteries and veins.Conclusions:Ultrasound examination of optic disc capillary hemangioma has certain characteristics, which can provide a valuable follow-up basis for clinical diagnosis.
6.Perfusion characteristics analysis of contrast-enhanced ultrasound in choroidal metastasis and choroidal hemangioma
Dongjun LI ; Wenli YANG ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Lin SHEN ; Qian LIU ; Yueming LIU ; Wenbin WEI
Chinese Journal of Ultrasonography 2021;30(7):563-568
Objective:To analyze the perfusion characteristics of choroidal metastasis using contrast-enhanced ultrasound, and compare with choroidal hemangioma.Methods:This was a retrospective study.From January 2016 to February 2018 in Beijing Tongren Hospital, a total of 21 eyes from 21 patients who were clinically diagnosed as choroidal metastasis were included as the choroidal metastasis group and 46 eyes from 46 patients who were diagnosed as choroidal hemangioma during the same period were included as the choroidal hemangioma group. All patients underwent contrast-enhanced ultrasound examination, and Sonoliver was used to obtain the data on quantitative parameters of the tumor and the adjacent normal orbital tissues, including maximum of intensity (IMAX), rise time (RT), time to peak (TTP), and mean transit time (mTT). The quantitative parameters between choroidal metastasis and normal orbital tissues were compared. And the quantitative parameters between choroidal metastasis and choroidal hemangioma were compared. The receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance.Results:The IMAX of choroidal metastasis was significantly higher than that of normal orbital tissues, while RT, TTP and mTT were significantly shorter than these of normal orbital tissues (all P<0.01). The IMAX of choroidal metastasis was lower than that of choroidal hemangioma, and RT, TTP and mTT were shorter than choroidal hemangioma (all P<0.01). The ROC curve analysis showed that area under curves of the IMAX, RT, TTP and mTT were 0.775 (95% CI=0.666-0.884), 0.970 (95% CI=0.896-0.996), 0.729 (95% CI=0.607-0.831) and 0.992 (95% CI=0.931-1.000) respectively. The sensitivities were 71.7%, 95.7%, 76.1% and 95.7%, and the specificities were 85.7%, 90.5%, 66.7% and 95.2%, respectively. Conclusions:Contrast-enhanced ultrasound can reflect the differences in perfusion characteristics between choroidal metastasis and choroidal hemangioma. RT and mTT are useful parameters in differential diagnosis between the two types of tumors.
7.Analysis of ultrasonic features of melanocytoma of optic disc
Qian LIU ; Wenli YANG ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Lin SHEN ; Wenbin WEI
Chinese Journal of Ultrasonography 2021;30(10):896-900
Objective:To investigate the ultrasonic features, contrast-enhanced ultrasound findings and long-term follow-up results of melanocytoma of the optic disc(MCOD).Methods:The data of 35 patients (35 eyes, 35 lesions) diagnosed with MCOD in Beijing Tongren Ophthalmic Center, Beijing Tongren Hospital from September 2012 to October 2020 were retrospectively analyzed. The B-mode ultrasonography and color Doppler flow imaging (CDFI) were performed on them. The size, morphology, internal echo and secondary changes of the lesions were analyzed. Contrast-enhanced ultrasound was performed on 13 patients. At the same time, 9 patients were followed up for long-term observation.Results:Six lesions (17.1%) showed hemispherical high echo, and 29 lesions (82.9%) showed limited uplift high echo. The largest base diameter of the lesions was (4.0±0.8)mm, average height was(1.9±0.4)mm. Internal echo characteristics: 8 lesions (22.9%) showed uniform echo and 27 lesions (77.1%) showed uneven echo.Lesion boundary: 35 lesions (100%) showed clear lesion boundary. Fifheen lesions (42.9%) showed secondary vitreous opacity. CDFI: blood flow signals could be detected inside the lesions in 19 lesions(54.3%), and not in 16 lesions(45.7%). Contrast-enhanced ultrasound showed 11 of the 13 lesions (84.6%) were completely filled with contrast agent.Conclusions:MCOD has certain ultrasonographic characteristics, which can provide a reliable basis for clinical diagnosis and differential diagnosis. There is no significant change in tumor size after long-term follow-up.
8.The value of color Doppler ultrasound in the detection of macular diseases in age-related cataract patients
Lin SHEN ; Wenli YANG ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Junfang XIAN
Chinese Journal of Ocular Fundus Diseases 2020;36(1):33-37
Objective To observe the application value with color Doppler flow imaging (CDFI) in the detection ofmacular diseases in senile cataract.Methods A cross-sectional descriptive study.From December 1 to December 30,2017,720 senile cataract patients (1380 eyes) diagnosed in Beijing Tongren Eye Center were included in this study.There were 330 males (629 eyes) and 390 females (751 eyes),with the mean age of 70.35 ± 19.05 years.There were 716 right eyes and 664 left eyes,with the visual acuity 0.05-0.8.The fundus of all the patients can be observed.All patients were examined by OCT using Cirrus HD-Model 5000 produced by German Carl Zeiss company and CDFI using MyLab90 color Doppler ultrasound system produced by ESAOTE S.P.A.Comparing the detection rate of macular lesions between the two methods by using X2 test.Using statistical methods to evaluate diagnostic tests,a crosstabulation was made to compare the consistency of frequency-domain OCT and CDFI in the diagnosis of macular lesions.Logistic regression analysis of correlation between detection of CDFI macular lesions and central foveal thickness (CFT),average thickness (AT),with or without macular anterior membrane,retinal folds,retinal cystoid edema,hard exudation,macular hole or lamellar macular hole,superficial detachment of neuroepithelium,detachment of pigment epithelium,vitreous macular traction.Results Two hundreds and thirty-nine eyes (17.3%) showed macular disease by OCT,and 161 eyes (11.7%) showed the abnormal echo in the macular region by CDFI.The detection rate of the macular disease between two methods were statistically significant (χ2=851.661,P< 0.001),however,the consistency was well (r=0.766,P=0.000).Logistic analysis showed that the detection rate of macular lesions was related to retinal folds,cysts in retina and CFT (r=1.396,1.041,0.12;P<0.01).Conclusion CDFI can effectively detect macular lesions that affect the visual prognosis of senile cataract patients.
9.Agreement of biometry parameters measured by IOLMaster 700 and Pentacam AXL in cataract eyes
Dongjun LI ; Wenli YANG ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Lin SHEN ; Junfang XIAN
Chinese Journal of Experimental Ophthalmology 2020;38(11):962-966
Objective:To compare the agreement of biometric parameters measured by a new swept-source optical coherence tomography IOLMaster 700 and a new Scheimpflug imaging combined with partial coherence interferometry biometer Pentacam AXL in cataractous eyes.Methods:A cross-sectional study was performed.A total of 146 eyes from 76 cataract patients were enrolled in Beijing Tongren Eye Center from 2 to 11 in January 2018, including 69 eyes in 36 males and 77 eyes in 40 females, the age ranged from 35 to 88 years, the mean age was (64.52±11.36) years.Axial length (AL), mean keratometry (Km), anterior chamber depth (ACD), central corneal thickness (CCT) and white-to-white (WTW) were measured with IOLMaster 700 and Pentacam AXL, respectively.The differences and correlations of the biometry parameters between the two devices were assessed.Bland-Altman method was used to evaluate the agreement of these parameters between the two devices and the 95% limits of agreement was calculated.This study adhered to the tenets of the Declaration of Helsinki and was approved by an Ethics Committee of Beijing Tongren Hospital (TRECKY2018-049).Results:The mean values of the AL measured by IOLMaster 700 and Pentacam AXL were (24.03±1.72)mm and (23.98±1.73)mm, Km were (44.04±1.71)D and (43.88±1.72)D, ACD were (3.24±0.47)mm and (3.28±0.47)mm, WTW were (11.82±0.51)mm and (11.49±0.49)mm, respectively.Compared with the values in Pentacam AXL, the AL, Km and WTW were larger while ACD was smaller in IOLMaster 700 with significant differences ( t=18.06, 8.94, 23.83, -15.36, all at P<0.01). The mean CCT values from the IOLMaster 700 and Pentacam AXL were (534.18±30.12)μm and (533.42±28.71)μm, respectively, with no significant difference ( t=1.04, P=0.30). The AL, Km, ACD, CCT and WTW from IOLMaster 700 were highly correlated with those from Pentacam AXL ( r=0.999, 0.992, 0.998, 0.956, 0.942; all at P<0.01). The Bland Altman analysis showed that the 95% limits of agreement of AL, Km, ACD, CCT and WTW were-0.02-0.11 mm, -0.27-0.59 D, -0.10-0.02 mm, -16.5-18.1 μm and 0.00-0.67 mm. Conclusions:IOLMaster 700 and Pentacam AXL have good agreements and narrow 95% limits of agreement in the measurements of AL, ACD, CCT, which can be clinically interchangeable.The 95% limits of agreement of WTW and Km are out of the clinically acceptable range, so the WTW and Km measured by the two devices are not interchangeable.
10.Agreement of biometry parameters measured by IOLMaster 700 with IOLMaster 500 in cataract eyes with high myopia
Lin SHEN ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Wenli YANG
Chinese Journal of Experimental Ophthalmology 2019;37(4):292-296
Objective To compare the agreement of axial length (AL),anterior chamber depth (ACD) and keratometry measured by IOLMaster 500 with IOLMaster 700 in cataract eyes with high myopia.Methods A cross-sectional study was performed.One hundred and fifty-two eyes of 87 cataract patients with high myopia were included from September to October 2017 in Beijing Tongren Hospital.The best corrected visual acuity (BCVA) was 0.05-1.0,and the refraction power was-6.25--21.00 D,with an average power of (-13.625 ± 7.375) D.A L,ACD and keratometry (Kf,Ks) were measured by IOLMaster 700 and IOLMaster 500 respectively for all the eyes.The eyes were assigned to AL>26-≤28 mm group,AL>28-<30 mm group and AL≥30 mm according to the results of IOLMaster 500.The measured differences between two devices were assessed using paired samples t-test,and the measured consistency of the two devices was evaluated using Bland-Altman agreement analysis.This study protocol was approved by Ethics Committee of Beijing Tongren Hospital and complied with Declaration of Helsinki.Results There were no significant differences in the AL and Kf measured by the two devices in all the three groups (all at P>0.05).Both ACD and Ks values measured by IOLMaster 700 were lower than those by IOLMaster 500 (both at P<0.05),which were clinically acceptable.The percentage beyond 95% agreement limit between IOLMaster 700 and IOLMaster 500 were 4.10%,2.17% and 3.03% for AL differences and 4.10%,4.34% 和 3.03% for Kf difference in the three groups.Significant differences were found in ACD and Ks between IOLMaster 700 and IOLMaster 500 at a clinically acceptable level (both at P<0.05),and Bland-Altamn agreement analysis showed that the percentage beyond 95% agreement limit between IOLMaster 700 and IOLMaster 500 were 4.10%,4.34% and 3.03% for both ACD and Ks differences in the three groups.Conclusions There is a good agreement in AL,ACD,Kf and Ks measured by IOLMaster 700 with IOLMaster 500 and is clinically interchangeable in cataract eyes with high myopia.However,IOLMaster 700 is better because it can provide the OCT image of macula.