1.Application of color doppler flow imaging in the diagnosis of ocular toxocariasis in children
Wei CHEN ; Wenli YANG ; Jinghua LIU ; Dongjun LI ; Ziyang WANG ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Lin SHEN ; Qian LIU
Chinese Journal of Ocular Fundus Diseases 2024;40(1):39-43
Objective:To summarize the characteristics of color doppler flow imaging (CDFI) of ocular toxocariasis (OT) in children.Methods:A retrospective clinical study. From July 2014 to June 2020, 61 OT patients with 61 eyes diagnosed through clinical and laboratory testing in the Department of Ophthalmology of Beijing Tongren Hospital of Capital Medical University were included in the study. There were 45 males with 45 eyes and 16 females with 16 eye (male: female=2.81:1). Age were (6.93±2.50) years. The right eye and left eye were 29 and 32 eyes, respectively. Both eyes of the patient underwent two-dimensional ultrasound and CDFI examination. Two dimensional ultrasound was used to estimate the axial length (AL) of the affected eyes and healthy eyes on the opposite side. Among them, 52 cases were measured for AL using optical biometry and/or A-mode ultrasound. Vitreoretinal surgery was performed within one week after ultrasound examination. Two-dimensional ultrasound was used to observe the morphology of vitreous opacity, its connection to the eyeball wall, and whether posterior vitreous detachment and retinal detachment have occurred. CDFI examination was used to observe the presence of blood flow signals on the pathological membrane. The detection rates of different forms of vitreous opacity and traction retinal detachment were calculated. The location of proliferative lesions in the eye was analyzed. Paired t-test was performed to compare the AL of the affected eye and the healthy eye on the opposite side. Perform Kappa consistency test on the location of proliferative lesions was used during CDFI examination and vitreoretinal surgery. Results:All affected eyes have varying degrees of vitreous opacity. Among them, 23 eyes (37.7%, 23/61) showed typical "Christmas tree" like turbidity; 27 eyes (44.3%, 27/61) had clustered and striped echoes; 9 eyes (14.8%, 9/61) had weak punctate and strip echoes. Two eyes (3.3%, 2/61) showed a large amount of dense punctate and strip-shaped echoes. There were 50 eyes (82.0%, 50/61) with traction retinal detachment, of which 46 eyes (92.0%, 46/50) had visible blood flow signals on the detached retina, and the remaining 4 eyes (8.0%, 4/50) had no blood flow signals. During CDFI and surgery, there were 5 (8.2%, 5/61) and 4 (6.6%, 4/61) eyes with visible proliferative lesions in the periphery, respectively; 18 (29.5%, 18/61) and 14 (23.0%, 14/61) eyes were distributed in the posterior pole, respectively; there were 38 (62.3%, 38/61) and 43 (70.5%, 43/61) eyes with both peripheral and posterior polar regions, respectively. The consistency between CDFI and surgery in detecting the location of proliferative lesions was good ( κ=0.832, 95% confidence interval 0.691-0.973, P<0.001). The two-dimensional ultrasound measurement results showed that the AL of the affected eye was shorter than that of the contralateral healthy eye in 46 cases (75.4%, 46/61). Among the 52 patients who underwent AL biometry, the AL of the affected eye was shorter than that of the contralateral healthy eye by (0.63±0.68) mm, and the difference was statistically significant ( t=-6.738, P<0.05). Conclusions:CDFI can clearly display various intraocular lesions (vitreous opacity and traction retinal detachment) and eyeball sizes in children with OT. Vitreous opacity is often manifested as "Christmas tree" like, clustered, strip-shaped.
2.Comparison of clinical efficacy between laparoscopic and open radical resection of hilar cholangiocarcinoma
Cheng ZHANG ; Dongjun AN ; Yang WANG ; Lin YANG ; Jintao WANG ; Li HAN ; Baoguo ZHAO ; Boqiang HAN ; Yao XU ; Jincheng HE
Chinese Journal of General Surgery 2023;38(1):17-22
Objective:To evaluate the efficacy of total laparoscopic surgery vs. open surgery for hilar cholangiocarcinoma. Methods:The clinical data of 45 patients undergoing laparoscopic radical resection of hilar cholangiocarcinoma and 42 patients by open surgery from Mar 2017 to Mar 2021 were retrospectively analyzed.Results:There was no significant difference in demographics, Bismuth classification and excision extension between the two groups (all P>0.05). The laparoscopic surgery used longer time ( t=-1.366, P<0.05). The intraoperative blood loss, number of lymph node dissection and postoperative hospital stay favored laparoscopic method( t=0.043, t=0.026, t=-1.852, P<0.05). R 0 radical resection rate,postoperative complications were also in favor of laparoscopic surgery ( χ2=3.216, χ2=2.566, all P<0.05). There was no significant difference in postoperative pathology and in hospital expenses (all P>0.05). The 1- and 3-year survival rate of the laparoscopic group was superior (all P<0.05). Conclusions:In spite of longer operational time,patients in laparoscopic hilar cholangiocarcinoma radical resection group have shorter postoperative in hospital stay and longer postoperative survival time.
3.Analysis of the feasibility of measurements and characteristics of intraocular lens tilt using swept-source optical coherence tomography biometer
Qi ZHAO ; Wenli YANG ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Yifeng LI ; Rui CUI ; Lin SHEN ; Lei LI ; Junfang XIAN
Chinese Journal of Experimental Ophthalmology 2023;41(6):554-560
Objective:To evaluate the feasibility of measurement and characteristics of intraocular lens (IOL) tilt using the swept-source optical coherence tomography (SS-OCT) biometer (IOLMaster 700) and to explore its potentially relevant parameters.Methods:A cross-sectional study was conducted.Two hundred and forty-two eyes (119 right eyes, 123 left eyes) of 185 patients after phacoemulsification and IOL implantation were included in Beijing Tongren Hospital from July to September 2018.The IOL position, angle κ, angle α, corneal curvature, anterior chamber depth (ACD), pupil diameter (PD), and axial length (AL) were obtained by IOLMaster 700, and the IOL tilt direction and magnitude were calculated.The within-subject standard deviation and intraclass correlation coefficient were used to evaluate the repeatability of three IOL tilt measurements.Binocular symmetry of IOL tilt and the correlation between IOL tilt and different influencing factors were evaluated by Pearson linear correlation analysis or Spearman rank correlation analysis.Influencing factors for IOL tilt were assessed by multiple linear regression analysis.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Beijing Tongren Hospital, Capital Medical University (No.TRECKY2018-049). Patients were informed of the purpose and methods of this study and signed the written informed consent.Results:The repeatability of IOL tilt measurements was excellent with a within-subject standard deviation of 5.16° for IOL tilt direction and 0.13° for IOL tilt magnitude.IOL tilt was mirror symmetric in both eyes.The IOL tilt direction in right eyes ranged from -89.60° to 87.53° with a mean of (18.85±29.65)°, and the tilt magnitude ranged from 1.32° to 7.05° with a mean of (4.16±1.26)°.The IOL tilt direction in left eyes ranged from -84.30° to 89.44° with a mean of (21.17±32.38)°, and the tilt magnitude ranged from 0.58° to 7.40° with a mean of (3.80±1.31)°.There were moderate and weak positive correlations of IOL tilt direction and tilt magnitude between both eyes ( r=0.473, P<0.001; r=0.335, P=0.011). IOL tilt magnitude was weakly positively correlated with angle α and IOL diopter ( rs=0.272, P=0.003; r=0.285, P=0.002), and was weakly negatively correlated with ACD, PD and AL ( r=-0.303, P=0.001; r=-0.233, P=0.011; rs=-0.331, P<0.001). In backward stepwise regression analysis, the regression equation of IOL tilt magnitude, angle α, ACD, PD, AL and IOL diopter in multiple linear regression analysis was as follows: IOL tilt magnitude=10.503+ 1.456×angle α-0.532×ACD-0.196×AL ( R2=0.400; F=8.588, P<0.001). Conclusions:The SS-OCT biometer can be an effective method to assess IOL tilt.IOL tilt is mirror symmetric between the right eyes and left eyes.
4.Ultrasonographic features of adenoma of the nonpigmented ciliary epithelium
Dongjun LI ; Wenli YANG ; Wenbin WEI ; Xiaolin XU ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Lin SHEN ; Qian LIU ; Chuanchuan WEI
Chinese Journal of Ocular Fundus Diseases 2022;38(3):191-196
Objective:To analyze the ultrasonographic features of adenoma of the nonpigmented ciliary epithelium (ANPCE).Methods:A retrospective series of case studies. From January 2014 to October 2021, 31 patients (31 eyes) with ANPCE (ANPCE group) were diagnosed in the eye center of Beijing Tongren Eye Center of Beijing Tongren Hospital, Capital Medical University, and 17 patients (17 eyes) with ciliary body melanoma (control group) diagnosed at the same time were selected as the control group. There was no significant difference in age ( t=-0.564) and sex composition ratio ( χ 2=0.182) between the two groups ( P=0.576, 0.670). All patients underwent ultrasound biomicroscopy to obtain the measurement parameters: tumor height, maximum basal diameter, maximum diameter, ratio of maximum diameter to basal diameter and ratio of maximum diameter to height; tumor location, shape, internal echogenicity intensity, echogenicity uniformity, degree of sound attenuation, invasion of iris, anterior displacement of the iris, lens subluxation were observed. The measurement parameters and observation indexes of the two groups were compared by independent sample t-test and χ 2 test. Receiver operating characteristic (ROC) curve was drawn, area under the ROC curve (AUC) was determined, and parameter indicators with differential diagnosis value were screened. Results:The maximum diameter, height, maximum basal diameter, ratio of the maximum diameter to the maximum basal diameter, and the ratio of the maximum diameter to the height of the tumors in the ANPCE group and the control group were 5.64±0.98 mm, 4.24±0.59 mm, 3.66±0.71 mm, 1.58±0.34, 1.34±0.19 and 7.82±2.03 mm, 4.47±2.44 mm, 7.02±1.96 mm, 1.13±0.16, 2.09±1.06. The maximum diameter, the maximum basal diameter, and the ratio of the maximum diameter to the height of the tumor in the ANPCE group were all smaller than those of the control group, and the ratio of the maximum diameter to the maximum basal diameter was greater than that of the control group, and the differences were statistically significant ( t=-4.159,-6.808, -2.924, 6.257; P<0.05). The tumors in the ANPCE group were mainly spherical (87.1%, 27/31), with no significant acoustic attenuation (77.4%, 24/31), less invading the root iris (77.4%, 24/31), and the tumors were mostly located in the ciliary body coronal (74.2%, 23/31); tumors in the control group were mainly hemispherical (47.1%, 8/17) or spherical (47.1%, 8/17), with significant sound attenuation (76.5%, 13/17), most of the tumors invaded the iris (70.6%, 12/17), and the tumors were mostly located from the pars plana to the coronal (76.5%, 13/17). There were statistically significant differences in the position, shape, sound attenuation degree, and whether it invaded the iris between the two groups of eyes ( χ 2=15.132, 19.767, 13.118, 10.581; P<0.05). The results of ROC curve analysis showed that the ratio of the largest diameter to the largest base diameter, the degree of sound attenuation and the AUC of whether the iris was violated were higher, which were 0.881, 0.769, and 0.740, respectively. Conclusions:Ultrasound biomicroscopy is helpful in the diagnosis and differential diagnosis of ANPCE and ciliary body melanoma. The ratio of maximum diameter to maximum basal diameter, the degree of sound attenuation and whether it invades the root iris are important parameters to distinguish the two tumors.
5.Haploidentical transplantation has a superior graft-versus-leukemia effect than HLA-matched sibling transplantation for Ph- high-risk B-cell acute lymphoblastic leukemia
Menglin FAN ; Yu WANG ; Ren LIN ; Tong LIN ; Fen HUANG ; Zhiping FAN ; Yajing XU ; Ting YANG ; Na XU ; Pengcheng SHI ; Danian NIE ; Dongjun LIN ; Zujun JIANG ; Shunqing WANG ; Jing SUN ; Xiaojun HUANG ; Qifa LIU ; Li XUAN
Chinese Medical Journal 2022;135(8):930-939
Background::Compared with human leukocyte antigen (HLA)-matched sibling donor (MSD) transplantation, it remains unclear whether haploidentical donor (HID) transplantation has a superior graft-versus-leukemia (GVL) effect for Philadelphia-negative (Ph-) high-risk B-cell acute lymphoblastic leukemia (B-ALL). This study aimed to compare the GVL effect between HID and MSD transplantation for Ph- high-risk B-ALL.Methods::This study population came from two prospective multicenter trials (NCT01883180, NCT02673008). Immunosuppressant withdrawal and prophylactic or pre-emptive donor lymphocyte infusion (DLI) were administered in patients without active graft-versus-host disease (GVHD) to prevent relapse. All patients with measurable residual disease (MRD) positivity posttransplantation (post-MRD+) or non-remission (NR) pre-transplantation received prophylactic/pre-emptive interventions. The primary endpoint was the incidence of post-MRD+.Results::A total of 335 patients with Ph- high-risk B-ALL were enrolled, including 145 and 190, respectively, in the HID and MSD groups. The 3-year cumulative incidence of post-MRD+ was 27.2% (95% confidence interval [CI]: 20.2%-34.7%) and 42.6% (35.5%-49.6%) in the HID and MSD groups (P = 0.003), respectively. A total of 156 patients received DLI, including 60 (41.4%) and 96 (50.5%), respectively, in the HID and MSD groups ( P= 0.096). The 3-year cumulative incidence of relapse was 18.6% (95% CI: 12.7%-25.4%) and 25.9% (19.9%-32.3%; P = 0.116) in the two groups, respectively. The 3-year overall survival (OS) was 67.4% (95% CI: 59.1%-74.4%) and 61.6% (54.2%-68.1%; P = 0.382), leukemia-free survival (LFS) was 63.4% (95% CI: 55.0%-70.7%) and 58.2% (50.8%-64.9%; P= 0.429), and GVHD-free/relapse-free survival (GRFS) was 51.7% (95% CI: 43.3%-59.5%) and 37.8% (30.9%-44.6%; P= 0.041), respectively, in the HID and MSD groups. Conclusion::HID transplantation has a lower incidence of post-MRD+ than MSD transplantation, suggesting that HID transplantation might have a superior GVL effect than MSD transplantation for Ph- high-risk B-ALL patients.Trial registration::ClinicalTrials.gov: NCT01883180, NCT02673008.
6.Analysis of ultrasonic diagnostic features of juxtapapillary capillary hemangioma
Yifeng LI ; Wenli YANG ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Rui CUI ; Lin SHEN ; Qian LIU ; Wenbin WEI ; Junfang XIAN
Chinese Journal of Ultrasonography 2021;30(2):161-166
Objective:To discuss the characteristics of ultrasound diagnosis of optic disc capillary hemangioma.Methods:The study analyzed retrospectively 7 cases of optic disc capillary hemangioma diagnosed in the Beijing Tongren Hospital from 2015 to 2018. The size, morphology, internal echo, and secondary changes of the lesion were analyzed during ultrasound examination.Color Doppler flow imaging was used to check the blood flow in the lesion.Results:Pre-optic disc occupying lesions could be detected in the ultrasound images of the 7 cases. Lesion size: average base diameters (5.39±1.90)mm×(4.79±1.28)mm, average height (3.61±1.37)mm. Lesion morphology: 5 cases were round, and 2 cases were irregular. Echo within the lesion: 3 cases had medium echo inside the lesion, and 4 cases had high echo inside the lesion. Internal echo characteristics: 5 cases had uniform echo, and 2 cases had uneven echo. Secondary changes: 6 cases had secondary retinal detachment and vitreous opacity, and 1 cases was accompanied by retinal hemangioma in other parts. In all cases, blood flow signals could be detected inside the space-occupying lesions, which were in the form of branches, stripes or spots, and the blood flow spectrum showed a parallel spectrum of arteries and veins.Conclusions:Ultrasound examination of optic disc capillary hemangioma has certain characteristics, which can provide a valuable follow-up basis for clinical diagnosis.
7.Perfusion characteristics analysis of contrast-enhanced ultrasound in choroidal metastasis and choroidal hemangioma
Dongjun LI ; Wenli YANG ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Lin SHEN ; Qian LIU ; Yueming LIU ; Wenbin WEI
Chinese Journal of Ultrasonography 2021;30(7):563-568
Objective:To analyze the perfusion characteristics of choroidal metastasis using contrast-enhanced ultrasound, and compare with choroidal hemangioma.Methods:This was a retrospective study.From January 2016 to February 2018 in Beijing Tongren Hospital, a total of 21 eyes from 21 patients who were clinically diagnosed as choroidal metastasis were included as the choroidal metastasis group and 46 eyes from 46 patients who were diagnosed as choroidal hemangioma during the same period were included as the choroidal hemangioma group. All patients underwent contrast-enhanced ultrasound examination, and Sonoliver was used to obtain the data on quantitative parameters of the tumor and the adjacent normal orbital tissues, including maximum of intensity (IMAX), rise time (RT), time to peak (TTP), and mean transit time (mTT). The quantitative parameters between choroidal metastasis and normal orbital tissues were compared. And the quantitative parameters between choroidal metastasis and choroidal hemangioma were compared. The receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance.Results:The IMAX of choroidal metastasis was significantly higher than that of normal orbital tissues, while RT, TTP and mTT were significantly shorter than these of normal orbital tissues (all P<0.01). The IMAX of choroidal metastasis was lower than that of choroidal hemangioma, and RT, TTP and mTT were shorter than choroidal hemangioma (all P<0.01). The ROC curve analysis showed that area under curves of the IMAX, RT, TTP and mTT were 0.775 (95% CI=0.666-0.884), 0.970 (95% CI=0.896-0.996), 0.729 (95% CI=0.607-0.831) and 0.992 (95% CI=0.931-1.000) respectively. The sensitivities were 71.7%, 95.7%, 76.1% and 95.7%, and the specificities were 85.7%, 90.5%, 66.7% and 95.2%, respectively. Conclusions:Contrast-enhanced ultrasound can reflect the differences in perfusion characteristics between choroidal metastasis and choroidal hemangioma. RT and mTT are useful parameters in differential diagnosis between the two types of tumors.
8.Analysis of ultrasonic features of melanocytoma of optic disc
Qian LIU ; Wenli YANG ; Dongjun LI ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Lin SHEN ; Wenbin WEI
Chinese Journal of Ultrasonography 2021;30(10):896-900
Objective:To investigate the ultrasonic features, contrast-enhanced ultrasound findings and long-term follow-up results of melanocytoma of the optic disc(MCOD).Methods:The data of 35 patients (35 eyes, 35 lesions) diagnosed with MCOD in Beijing Tongren Ophthalmic Center, Beijing Tongren Hospital from September 2012 to October 2020 were retrospectively analyzed. The B-mode ultrasonography and color Doppler flow imaging (CDFI) were performed on them. The size, morphology, internal echo and secondary changes of the lesions were analyzed. Contrast-enhanced ultrasound was performed on 13 patients. At the same time, 9 patients were followed up for long-term observation.Results:Six lesions (17.1%) showed hemispherical high echo, and 29 lesions (82.9%) showed limited uplift high echo. The largest base diameter of the lesions was (4.0±0.8)mm, average height was(1.9±0.4)mm. Internal echo characteristics: 8 lesions (22.9%) showed uniform echo and 27 lesions (77.1%) showed uneven echo.Lesion boundary: 35 lesions (100%) showed clear lesion boundary. Fifheen lesions (42.9%) showed secondary vitreous opacity. CDFI: blood flow signals could be detected inside the lesions in 19 lesions(54.3%), and not in 16 lesions(45.7%). Contrast-enhanced ultrasound showed 11 of the 13 lesions (84.6%) were completely filled with contrast agent.Conclusions:MCOD has certain ultrasonographic characteristics, which can provide a reliable basis for clinical diagnosis and differential diagnosis. There is no significant change in tumor size after long-term follow-up.
9.Comparing two pancreaticojejunostomy methods on the pancreatic fistula rates after laparoscopic pancreaticoduodenectomy
Cheng ZHANG ; Dongjun AN ; Yang WANG ; Lin YANG ; Jintao WANG ; Li HAN ; Baoguo ZHAO ; Yao XU ; Boqiang HAN
Chinese Journal of Hepatobiliary Surgery 2021;27(8):610-613
Objective:To compare the embedding anastomosis with the intermittent eversion anastomosis on the pancreatic fistula rates after laparoscopic pancreaticoduodenectomy (LPD).Methods:The clinical data of 116 patients who underwent LPD at the Center Hospital of Xianyang City affiliated to Xi' an Jiaotong University Health Science Center from March 2016 to March 2020 were retrospectively studied. According to the method of pancreaticojejunostomy used, these patients were divided into the following two groups: the embedding anastomosis group ( n=55) and the intermittent eversion anastomosis group ( n=61). The duration of pancreaticojejunostomy, bilioenterostomy and gastrointestinal anastomoses, and the amounts of intraoperative blood loss and postoperative complication rates were compared between the two groups. Results:Of 116 patients in this study, there were 67 males and 49 females, with a median age of 61.5 years. No perioperative death occurred in the 2 groups. The operation time, digestive tract reconstruction time and pancreaticojejunostomy time in the embedded anastomosis group were (260±20), (65±15) and (35±15) min, respectively, which were significantly lower than those in the intermittent eversion anastomosis group (305±25), (81±25) and (45±12) min, (all P<0.05). The grade A and B pancreatic fistula rates in the embedded anastomosis group were 27.3%(15/55) and 21.8%(12/55), respectively, which were significantly higher than those in the intermittent eversion anastomosis group [8.2%(5/61) and 6.6%(4/61)], (all P<0.05). The postoperative hospital stay in the intermittent eversion anastomosis group (10.3±1.1) d was significantly lower than that in the embedding anastomosis group [(15.2±3.2) d, P<0.05]. Conclusion:In LPD, when compared with embedded pancreaticojejunostomy, intermittent eversion pancreaticojejunostomy reduced the postoperative pancreatic fistula rate and shortened the postoperative hospital stay.
10.Agreement of biometry parameters measured by IOLMaster 700 and Pentacam AXL in cataract eyes
Dongjun LI ; Wenli YANG ; Ziyang WANG ; Wei CHEN ; Qi ZHAO ; Yifeng LI ; Rui CUI ; Lin SHEN ; Junfang XIAN
Chinese Journal of Experimental Ophthalmology 2020;38(11):962-966
Objective:To compare the agreement of biometric parameters measured by a new swept-source optical coherence tomography IOLMaster 700 and a new Scheimpflug imaging combined with partial coherence interferometry biometer Pentacam AXL in cataractous eyes.Methods:A cross-sectional study was performed.A total of 146 eyes from 76 cataract patients were enrolled in Beijing Tongren Eye Center from 2 to 11 in January 2018, including 69 eyes in 36 males and 77 eyes in 40 females, the age ranged from 35 to 88 years, the mean age was (64.52±11.36) years.Axial length (AL), mean keratometry (Km), anterior chamber depth (ACD), central corneal thickness (CCT) and white-to-white (WTW) were measured with IOLMaster 700 and Pentacam AXL, respectively.The differences and correlations of the biometry parameters between the two devices were assessed.Bland-Altman method was used to evaluate the agreement of these parameters between the two devices and the 95% limits of agreement was calculated.This study adhered to the tenets of the Declaration of Helsinki and was approved by an Ethics Committee of Beijing Tongren Hospital (TRECKY2018-049).Results:The mean values of the AL measured by IOLMaster 700 and Pentacam AXL were (24.03±1.72)mm and (23.98±1.73)mm, Km were (44.04±1.71)D and (43.88±1.72)D, ACD were (3.24±0.47)mm and (3.28±0.47)mm, WTW were (11.82±0.51)mm and (11.49±0.49)mm, respectively.Compared with the values in Pentacam AXL, the AL, Km and WTW were larger while ACD was smaller in IOLMaster 700 with significant differences ( t=18.06, 8.94, 23.83, -15.36, all at P<0.01). The mean CCT values from the IOLMaster 700 and Pentacam AXL were (534.18±30.12)μm and (533.42±28.71)μm, respectively, with no significant difference ( t=1.04, P=0.30). The AL, Km, ACD, CCT and WTW from IOLMaster 700 were highly correlated with those from Pentacam AXL ( r=0.999, 0.992, 0.998, 0.956, 0.942; all at P<0.01). The Bland Altman analysis showed that the 95% limits of agreement of AL, Km, ACD, CCT and WTW were-0.02-0.11 mm, -0.27-0.59 D, -0.10-0.02 mm, -16.5-18.1 μm and 0.00-0.67 mm. Conclusions:IOLMaster 700 and Pentacam AXL have good agreements and narrow 95% limits of agreement in the measurements of AL, ACD, CCT, which can be clinically interchangeable.The 95% limits of agreement of WTW and Km are out of the clinically acceptable range, so the WTW and Km measured by the two devices are not interchangeable.

Result Analysis
Print
Save
E-mail