1.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
2.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
3.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
4.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
5.Research progress on the application of visual electrophysiological examination in early diagnosis of glaucoma
Chang SUN ; Rong ZHANG ; Xiaolin XIAO ; Minpeng XU ; Dong MING ; Xia HUA
International Eye Science 2025;25(7):1073-1078
Glaucoma is a group of optic nerve disorders characterized by progressive optic nerve atrophy and visual field defects, which can lead to irreversible blindness. Early diagnosis of glaucoma is essential for preventing visual loss. However, due to the absence of obvious early symptoms, the diagnosis of glaucoma remains challenging. Visual electrophysiological examinations, an objective approach for evaluating visual function, have the potential to be used in the early diagnosis of glaucoma. This review integrates the latest publications to introduce visual electrophysiological examination techniques, including electroretinography(ERG)and visual evoked potential(VEP). It also explores the mechanisms underlying these techniques and their application value in the early diagnosis of glaucoma. In addition, this review summarizes the advantages, limitations, and applicable scenarios of different visual electrophysiological techniques. Finally, the review provides an outlook on the development prospects of visual electrophysiological techniques in the early diagnosis of glaucoma. The findings of this review can assist clinicians in selecting appropriate diagnostic methods, promote the innovation and development of early visual electrophysiological diagnostic techniques for glaucoma, and contribute to reducing the risk of blindness caused by glaucoma.
6.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
7.Inhibitory effect of miR-133a on liver cancer through tar-geted regulation of G6PD expression
Ya-Dong WANG ; Xue-Jun SUN ; Chun-Yu YANG ; Gui-Ping WANG ; Ming JIN ; He LI ; Jia-Jun YIN
Chinese Journal of Current Advances in General Surgery 2024;27(1):25-29
Objective:To explore if miR-133a is involved in the occurrence and development of hepatocellular carcinoma(HCC)via regulating G6PD.Methods:Bioinformatics analysis predicted the binding sites of miR-133a and G6PD;RT-PCR or western blot was used to assess the expres-sion of miR-133a and G6PD in HCC tissues and the adjacent normal tissues;CCK-8 and flow cy-tometry assays were performed to evaluate the effects of miR-133a/G6PD on cell proliferation,apop-tosis;Fluorescent reporter gene and western blot assays were used to assess the effect of miR-133a on G6PD expression.Results:miR-133a expression was decreased in HCC tissues while G6PD was increased(P0.01);Up-regulation of miR-133a significantly reduced G6PD expression(P<0.01);up-reg-ulation of miR-133a inhibited cell growth and promoted cell apoptosis(P<0.05),whereas these effects induced by miR-133a over-expression were all abolished when G6PD was up-regulated(P<0.01).Conclusion:miR-133a represses the occurrence and development of HCC via targeting G6PD.
8.Constructing a predictive model for the death risk of patients with septic shock based on supervised machine learning algorithms
Zheng XIE ; Jing JIN ; Dongsong LIU ; Shengyi LU ; Hui YU ; Dong HAN ; Wei SUN ; Ming HUANG
Chinese Critical Care Medicine 2024;36(4):345-352
Objective:To construct and validate the best predictive model for 28-day death risk in patients with septic shock based on different supervised machine learning algorithms.Methods:The patients with septic shock meeting the Sepsis-3 criteria were selected from Medical Information Mart for Intensive Care-Ⅳ v2.0 (MIMIC-Ⅳ v2.0). According to the principle of random allocation, 70% of these patients were used as the training set, and 30% as the validation set. Relevant predictive variables were extracted from three aspects: demographic characteristics and basic vital signs, serum indicators within 24 hours of intensive care unit (ICU) admission and complications possibly affecting indicators, functional scoring and advanced life support. The predictive efficacy of models constructed using five mainstream machine learning algorithms including decision tree classification and regression tree (CART), random forest (RF), support vector machine (SVM), linear regression (LR), and super learner [SL; combined CART, RF and extreme gradient boosting (XGBoost)] for 28-day death in patients with septic shock was compared, and the best algorithm model was selected. The optimal predictive variables were determined by intersecting the results from LASSO regression, RF, and XGBoost algorithms, and a predictive model was constructed. The predictive efficacy of the model was validated by drawing receiver operator characteristic curve (ROC curve), the accuracy of the model was assessed using calibration curves, and the practicality of the model was verified through decision curve analysis (DCA).Results:A total of 3?295 patients with septic shock were included, with 2?164 surviving and 1?131 dying within 28 days, resulting in a mortality of 34.32%. Of these, 2?307 were in the training set (with 792 deaths within 28 days, a mortality of 34.33%), and 988 in the validation set (with 339 deaths within 28 days, a mortality of 34.31%). Five machine learning models were established based on the training set data. After including variables at three aspects, the area under the ROC curve (AUC) of RF, SVM, and LR machine learning algorithm models for predicting 28-day death in septic shock patients in the validation set was 0.823 [95% confidence interval (95% CI) was 0.795-0.849], 0.823 (95% CI was 0.796-0.849), and 0.810 (95% CI was 0.782-0.838), respectively, which were higher than that of the CART algorithm model (AUC = 0.750, 95% CI was 0.717-0.782) and SL algorithm model (AUC = 0.756, 95% CI was 0.724-0.789). Thus above three algorithm models were determined to be the best algorithm models. After integrating variables from three aspects, 16 optimal predictive variables were identified through intersection by LASSO regression, RF, and XGBoost algorithms, including the highest pH value, the highest albumin (Alb), the highest body temperature, the lowest lactic acid (Lac), the highest Lac, the highest serum creatinine (SCr), the highest Ca 2+, the lowest hemoglobin (Hb), the lowest white blood cell count (WBC), age, simplified acute physiology score Ⅲ (SAPSⅢ), the highest WBC, acute physiology score Ⅲ (APSⅢ), the lowest Na +, body mass index (BMI), and the shortest activated partial thromboplastin time (APTT) within 24 hours of ICU admission. ROC curve analysis showed that the Logistic regression model constructed with above 16 optimal predictive variables was the best predictive model, with an AUC of 0.806 (95% CI was 0.778-0.835) in the validation set. The calibration curve and DCA curve showed that this model had high accuracy and the highest net benefit could reach 0.3, which was significantly outperforming traditional models based on single functional score [APSⅢ score, SAPSⅢ score, and sequential organ failure assessment (SOFA) score] with AUC (95% CI) of 0.746 (0.715-0.778), 0.765 (0.734-0.796), and 0.625 (0.589-0.661), respectively. Conclusions:The Logistic regression model, constructed using 16 optimal predictive variables including pH value, Alb, body temperature, Lac, SCr, Ca 2+, Hb, WBC, SAPSⅢ score, APSⅢ score, Na +, BMI, and APTT, is identified as the best predictive model for the 28-day death risk in patients with septic shock. Its performance is stable, with high discriminative ability and accuracy.
9.Value of 18F-FDG PET/CT imaging in hemophagocytic lymphohistiocytosis
Na DANG ; Ying SUN ; Youwen DONG ; Guqing ZHANG ; Ming GAO
Chinese Journal of Nuclear Medicine and Molecular Imaging 2024;44(7):401-405
Objective:To explore the diagnostic value of 18F-FDG PET/CT imaging in etiology of patients with hemophagocytic lymphohistiocytosis (HLH). Methods:Retrospective analysis was performed on 49 patients newly diagnosed as HLH (32 males, 17 females; age 19-61 years) who received 18F-FDG PET/CT imaging in Affiliated Hospital of Jining Medical University from January 2017 to January 2023. PET/CT images and clinical parameters were observed and recorded. Based on the pathological examination and clinical follow-up results, diagnostic efficacies for HLH etiology of PET/CT, PET and CT imaging were calculated. χ2 test, independent-sample t test and Mann-Whitney U test were used to compare the differences between hematologic tumors associated HLH and non-hematologic tumor associated HLH. Multivariate logistic regression was used to analyze the predictors of secondary HLH in hematologic tumors. ROC curve analysis was used to calculate AUCs and optimal threshold of lymph node SUV max and soluble CD25 (sCD25) to predict secondary HLH in patients with hematologic tumors. Results:The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of PET/CT, PET and CT in the etiological diagnosis of HLH were 85.7%(30/35), 8/10, 84.4%(38/45), 93.8%(30/32), 8/13; 77.1%(27/35), 6/10, 73.3%(33/45), 87.1%(27/31), 6/14; 62.9%(22/35), 5/10, 60.0%(27/45), 81.5%(22/27), 5/18, respectively. There were differences in lymph node distribution and boundary, liver and spleen and bone lesions, SUV max of lymph node and liver and spleen and bone, gender, age, WBC, neutrophil (ANC), PLT, lactate dehydrogenase (LDH), total bilirubin (TBIL), C-reactive protein (CRP) and sCD25 between different etiology groups ( χ2 values: 3.91-9.66, t values: 3.75-7.90, z values: 3.82-4.01, all P<0.05). SUV max of lymph nodes and sCD25 were predictive factors for secondary HLH of hematological tumors (odds ratio ( OR): 1.28 (95% CI: 1.09-1.72), 1.56 (95% CI: 1.17-2.49), P values: 0.004, 0.013). The optimal thresholds were 12.6 and 40 028 ng/L, with the AUC of 0.87 and 0.76, with the sensitivity and specificity of 88.6%(31/35) and 8/10, 65.7%(23/35) and 7/10, respectively. The combined AUC was 0.83 and the sensitivity and specificity were 74.3% (26/35) and 9/10. Conclusions:18F-FDG PET/CT imaging is of high value for the diagnosis of the cause of HLH. SUV max of lymph node and sCD25 are predictive factors for secondary HLH of hematologic tumors.
10.Development and Application of Detection Methods for Capture and Transcription Elongation Rate of Bacterial Nascent RNA
Yuan-Yuan LI ; Yu-Ting WANG ; Zi-Chun WU ; Hao-Xuan LI ; Ming-Yue FEI ; Dong-Chang SUN ; O. Claudio GUALERZI ; Attilio FABBRETTI ; Anna Maria GIULIODORI ; Hong-Xia MA ; Cheng-Guang HE
Progress in Biochemistry and Biophysics 2024;51(9):2249-2260
ObjectiveDetection and quantification of RNA synthesis in cells is a widely used technique for monitoring cell viability, health, and metabolic rate.After exposure to environmental stimuli, both the internal reference gene and target gene would be degraded. As a result, it is imperative to consider the accurate capture of nascent RNA and the detection of transcriptional levels of RNA following environmental stimulation. This study aims to create a Click Chemistry method that utilizes its property to capture nascent RNA from total RNA that was stimulated by the environment. MethodsThe new RNA was labeled with 5-ethyluridine (5-EU) instead of uracil, and the azido-biotin medium ligand was connected to the magnetic sphere using a combination of “Click Chemistry” and magnetic bead screening. Then the new RNA was captured and the transcription rate of 16S rRNA was detected by fluorescence molecular beacon (M.B.) and quantitative reverse transcription PCR (qRT-PCR). ResultsThe bacterial nascent RNA captured by “Click Chemistry” screening can be used as a reverse transcription template to form cDNA. Combined with the fluorescent molecular beacon M.B.1, the synthesis rate of rRNA at 37℃ is 1.2 times higher than that at 15℃. The 16S rRNA gene and cspI gene can be detected by fluorescent quantitative PCR,it was found that the measured relative gene expression changes were significantly enhanced at 25℃ and 16℃ when analyzed with nascent RNA rather than total RNA, enabling accurate detection of RNA transcription rates. ConclusionCompared to other article reported experimental methods that utilize screening magnetic columns, the technical scheme employed in this study is more suitable for bacteria, and the operation steps are simple and easy to implement, making it an effective RNA capture method for researchers.

Result Analysis
Print
Save
E-mail