1.Analysis on Quality Standard of Sennae Folium(Cassia angustifolia) Dispensing Granules Based on Standard Decoctions
Jinxin LI ; Xue DONG ; Shuai DUAN ; Guiyun CAO ; Jinghua ZHANG ; Yongfu LUAN ; Yongqiang LIN ; Xiaodi DONG ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(9):192-200
ObjectiveTo establish the quality standards for Sennae Folium(Cassia angustifolia) dispensing granules based on standard decoctions. MethodsHigh performance liquid chromatography(HPLC) specific chromatograms were established for 15 batches of Sennae Folium(C. angustifolia) standard decoctions and 10 of Sennae Folium(C. angustifolia) dispensing granules from different manufacturers, and the similarity evaluation, hierarchical cluster analysis(HCA) and principal component analysis(PCA) were performed. Linear calibration with two reference substances(LCTRS) and quantitative analysis of multi-components by single-marker(QAMS) were established for the common peaks in the specific chromatograms to determine the contents of main components in the decoction pieces, standard decoctions and dispensing granules, and to calculate their transfer rates from decoction pieces to standard decoctions and dispensing granules. ResultsThe similarities of specific chromatograms of 15 batches of Sennae Folium(C. angustifolia) standard decoctions and 10 batches of Sennae Folium(C. angustifolia) dispensing granules were all greater than 0.95, and a total of 8 characteristic peaks were calibrated, and five of them were identified, including kaempferol-3,7-O-diglucoside, apigenin-6,8-di-C-glucoside, quercetin-3-O-gentianoside, sennoside B and sennoside A. HCA and PCA results showed that there were certain differences in the composition of different batches of standard decoctions, but no clustering was observed in the production area. As the standard decoctions, the extract rate of 15 batches of samples was 26.54%-45.38%, the contents of kaempferol-3,7-O-diglucoside, apigenin-6,8-di-C-glucoside, quercetin-3-O-gentianoside, sennoside B and sennoside A were 12.16-19.26, 2.57-4.94, 3.27-5.11, 6.75-11.39, 4.69-7.79 mg·g-1, and their transfer rates from decoction pieces to standard decoctions were 45.41%-79.02%, 29.12%-55.07%, 40.52%-67.90%, 24.72%-49.12%, 27.54%-49.34%, respectively. The extract rates of Sennae Folium(C. angustifolia) dispensing granules(C8-C10) were 38.10%-39.50%, the transfer rates of the above five components from decoction pieces to dispensing granules were 72.85%-73.58%, 53.43%-53.94%, 40.19%-40.74%, 24.62%-25.00%, 28.65%-29.11%, respectively, which were generally consistent with the transfer rates from decoction pieces to standard decoctions. ConclusionCompared with the relative retention time method, LCTRS has higher prediction accuracy and is more suitable for chromatographic columns. The established quality control standard of Sennae Folium(C. angustifolia) dispensing granules based on standard decoction is reasonable and reliable, and all indicators of samples from different manufacturers are within the range specified based on the standard decoction, which can provide reference for the quality control and process research of this dispensing granules.
2.Analysis on Quality Standard of Hedyotis Herba Dispensing Granules Based on Standard Decoction
Jinghua ZHANG ; Nana WU ; Yanan LYU ; Guiyun CAO ; Jiacheng XU ; Yongqiang LIN ; Xiaodi DONG ; Jinxin LI ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(10):210-217
ObjectiveTo establish the specific chromatogram and quantitative analysis of multi-components by single-marker(QAMS) based on linear calibration using two reference substances(LCTRS), explore the consistency between Hedyotis Herba dispensing granules and standard decoction, and evaluate the quality of the dispensing granules. MethodsHigh performance liquid chromatography(HPLC) specific chromatogram was established based on 15 batches of Hedyotis Herba standard decoction and 10 batches of the dispensing granules, and LCTRS was used to locate chromatographic peaks. The actual retention times of 7 characteristic peaks in the specific chromatogram was measured on 24 different types of C18 columns, taking deacetyl asperulosidic acid and asperulosidic acid as the dual standard compounds, the retention times of the other 5 characteristic peaks were predicted and validated. Based on this, QAMS was developed to determine the contents of four components(deacetyl asperulosidic acid, deacetyl asperulosidic acid methyl ester, asperulosidic acid, and p-coumaric acid). Then, the relative correction factors of deacetyl asperulosidic acid, deacetyl asperulosidic acid methyl ester and p-coumaric acid were calculated using the reference peak of asperulosidic acid in the dual standard compounds, and each component was quantified accordingly. Finally, the consistency between the dispensing granules and standard decoction was assessed by taking extract rate of the standard decoction, consistency of the specific chromatograms, contents and transfer rates of the indicator components as indexes, and the quality of the dispensing granules was evaluated. ResultsThere were 7 common peaks in the characteristic chromatogram of samples of Hedyotis Herba standard decoction and the dispensing granules, and four of them were identified by reference standards, namely deacetyl asperulosidic acid(peak 1), deacetyl asperulosidic acid methyl ester(peak 3), asperulosidic acid(peak 6) and p-coumaric acid(peak 7). The similarity between the dispensing granules and the standard decoction was >0.9. The absolute deviation in the predicted retention time for each component by LCTRS was lower than that of the relative retention time method. The extract rate of the 15 batches of Hedyotis Herba standard decoction ranged from 7.89% to 14.60%, the contents of deacetyl asperulosidic acid, deacetyl asperulosidic acid methyl ester, asperulosidic acid and p-coumaric acid were 6.62-19.70, 3.83-17.99, 1.57-6.69, 1.62-4.52 mg·g-1, and the transfer rates of these components from decoction pieces to the standard decoction were 22.89%-39.60%, 34.03%-62.24%, 24.25%-43.70%, and 40.58%-73.71%, respectively. The extract rate, index component contents and transfer rates from decoction pieces to the three batches of Hedyotis Herba dispensing granules(P1-P3), produced by manufacturer A, were similar to those of the standard decoction prepared from the same batch of decoction pieces, and all fell within the specified range. The contents of the 4 indicator components in 7 batches of the dispensing granules(P4-P10) from manufacturers B-E were all within the range of the content converted from the standard decoction based on the quantity of the dispensing granules. ConclusionThe established specific chromatogram and QAMS based on LCTRS are reasonable and reliable. Based on the evaluation indicators of standard decoction yield, consistency of specific chromatograms, contents and transfer rates of the four index components, the 10 batches of Hedyotis Herba dispensing granules from various manufacturers have exhibited good consistency with the standard decoction, indicating that the current production process is relatively reasonable.
3.Quality Evaluation of Chuanxiong Rhizoma Dispensing Granules Based on HPLC Specific Chromatogram and Two Reference Substances for Determination of Multiple Components
Jinxin LI ; Xue DONG ; Shuai DUAN ; Guiyun CAO ; Jinghua ZHANG ; Yongfu LUAN ; Yongqiang LIN ; Xiaodi DONG ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(11):246-253
ObjectiveTo establish the specific chromatogram of Chuanxiong Rhizoma dispensing granules(CRdg), and to evaluate its quality by chemometrics and two reference substances for determination of multiple components(TRSDMC). MethodsHigh performance liquid chromatography(HPLC) specific chromatograms were established using 13 batches of CRdg from 7 manufacturers, and preliminary quality evaluation was performed by similarity evaluation and chemometrics analysis. Eight characteristic peaks in the specific chromatogram of CRdg were measured on 22 different types of C18 columns, and the actual retention times were recorded. Taking chlorogenic acid(peak 1) and senkyunolide A(peak 8) as double standard compounds, the retention times of the eight characteristic peaks were predicted by linear calibration using two reference substances(LCTRS), and the method was validated on three other columns of different brands. Taking chlorogenic acid as reference peak, the relative correction factor method(RCFM) was used to quantify cryptochlorogenic acid, caffeic acid, ferulic acid, senkyunolide I and senkyunolide A, and the results were compared with the external standard method(ESM). ResultsThe similarities of specific chromatograms of 13 batches of CRdg were all >0.90, and a total of 8 characteristic peaks were calibrated, and six of them were identified, including chlorogenic acid(peak 1), cryptochlorogenic acid(peak 2), caffeic acid(peak 3), ferulic acid(peak 5), senkyunolide I(peak 6) and senkyunolide A(peak 8). Through chemometric analysis, it was found that ferulic acid, chlorogenic acid, senkyunolide I and cryptochlorogenic acid were the main components causing quality difference in CRdg, and the accuracy of LCTRS in predicting the retention time of 8 characteristic peaks was superior to that of the relative retention time method(RRT). Further comparison of the results obtained from RCFM and ESM showed that there was no statistically significant difference between the two methods. ConclusionA quality evaluation method for CRdg based on HPLC specific chromatogram and TRSDMC is established, its qualitative accuracy is better than that of RRT, the quantitative accuracy is similar to that of ESM, and 4 quality-differentiated components among different manufacturers are found. This method is stable and reliable, and has reference value for the quality evaluation of other dispensing granules.
4.Quality Evaluation of Chuanxiong Rhizoma Dispensing Granules Based on HPLC Specific Chromatogram and Two Reference Substances for Determination of Multiple Components
Jinxin LI ; Xue DONG ; Shuai DUAN ; Guiyun CAO ; Jinghua ZHANG ; Yongfu LUAN ; Yongqiang LIN ; Xiaodi DONG ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(11):246-253
ObjectiveTo establish the specific chromatogram of Chuanxiong Rhizoma dispensing granules(CRdg), and to evaluate its quality by chemometrics and two reference substances for determination of multiple components(TRSDMC). MethodsHigh performance liquid chromatography(HPLC) specific chromatograms were established using 13 batches of CRdg from 7 manufacturers, and preliminary quality evaluation was performed by similarity evaluation and chemometrics analysis. Eight characteristic peaks in the specific chromatogram of CRdg were measured on 22 different types of C18 columns, and the actual retention times were recorded. Taking chlorogenic acid(peak 1) and senkyunolide A(peak 8) as double standard compounds, the retention times of the eight characteristic peaks were predicted by linear calibration using two reference substances(LCTRS), and the method was validated on three other columns of different brands. Taking chlorogenic acid as reference peak, the relative correction factor method(RCFM) was used to quantify cryptochlorogenic acid, caffeic acid, ferulic acid, senkyunolide I and senkyunolide A, and the results were compared with the external standard method(ESM). ResultsThe similarities of specific chromatograms of 13 batches of CRdg were all >0.90, and a total of 8 characteristic peaks were calibrated, and six of them were identified, including chlorogenic acid(peak 1), cryptochlorogenic acid(peak 2), caffeic acid(peak 3), ferulic acid(peak 5), senkyunolide I(peak 6) and senkyunolide A(peak 8). Through chemometric analysis, it was found that ferulic acid, chlorogenic acid, senkyunolide I and cryptochlorogenic acid were the main components causing quality difference in CRdg, and the accuracy of LCTRS in predicting the retention time of 8 characteristic peaks was superior to that of the relative retention time method(RRT). Further comparison of the results obtained from RCFM and ESM showed that there was no statistically significant difference between the two methods. ConclusionA quality evaluation method for CRdg based on HPLC specific chromatogram and TRSDMC is established, its qualitative accuracy is better than that of RRT, the quantitative accuracy is similar to that of ESM, and 4 quality-differentiated components among different manufacturers are found. This method is stable and reliable, and has reference value for the quality evaluation of other dispensing granules.
5.Characterization of non-alcoholic fatty liver disease–related hepatocellular carcinoma on contrast-enhanced ultrasound with Sonazoid
Yi DONG ; Juan CHENG ; Yun-Lin HUANG ; Yi-Jie QIU ; Jia-Ying CAO ; Xiu-Yun LU ; Wen-Ping WANG ; Kathleen MÖLLER ; Christoph F. DIETRICH
Ultrasonography 2025;44(3):232-242
Purpose:
This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).
Methods:
In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.
Results:
From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.
Conclusion
Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.
6.Characterization of non-alcoholic fatty liver disease–related hepatocellular carcinoma on contrast-enhanced ultrasound with Sonazoid
Yi DONG ; Juan CHENG ; Yun-Lin HUANG ; Yi-Jie QIU ; Jia-Ying CAO ; Xiu-Yun LU ; Wen-Ping WANG ; Kathleen MÖLLER ; Christoph F. DIETRICH
Ultrasonography 2025;44(3):232-242
Purpose:
This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).
Methods:
In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.
Results:
From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.
Conclusion
Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.
7.Characterization of non-alcoholic fatty liver disease–related hepatocellular carcinoma on contrast-enhanced ultrasound with Sonazoid
Yi DONG ; Juan CHENG ; Yun-Lin HUANG ; Yi-Jie QIU ; Jia-Ying CAO ; Xiu-Yun LU ; Wen-Ping WANG ; Kathleen MÖLLER ; Christoph F. DIETRICH
Ultrasonography 2025;44(3):232-242
Purpose:
This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).
Methods:
In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.
Results:
From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.
Conclusion
Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.
8.Characterization of non-alcoholic fatty liver disease–related hepatocellular carcinoma on contrast-enhanced ultrasound with Sonazoid
Yi DONG ; Juan CHENG ; Yun-Lin HUANG ; Yi-Jie QIU ; Jia-Ying CAO ; Xiu-Yun LU ; Wen-Ping WANG ; Kathleen MÖLLER ; Christoph F. DIETRICH
Ultrasonography 2025;44(3):232-242
Purpose:
This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).
Methods:
In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.
Results:
From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.
Conclusion
Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.
9.Characterization of non-alcoholic fatty liver disease–related hepatocellular carcinoma on contrast-enhanced ultrasound with Sonazoid
Yi DONG ; Juan CHENG ; Yun-Lin HUANG ; Yi-Jie QIU ; Jia-Ying CAO ; Xiu-Yun LU ; Wen-Ping WANG ; Kathleen MÖLLER ; Christoph F. DIETRICH
Ultrasonography 2025;44(3):232-242
Purpose:
This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).
Methods:
In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.
Results:
From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.
Conclusion
Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.
10.High-quality acceleration of the Chinese national schistosomiasis elimination programme to advance the building of Healthy China
Jing XU ; Qiang WANG ; Kun YANG ; Liyong WEN ; Tianping WANG ; Dandan LIN ; Jianbing LIU ; Jie ZHOU ; Yang LIU ; Yi DONG ; Chunli CAO ; Shizhu LI ; Xiaonong ZHOU
Chinese Journal of Schistosomiasis Control 2024;36(1):1-6
The goal of achieving elimination of schistosomiasis across all endemic counties in China by 2030 was proposed in the Outline of the Healthy China 2030 Plan. On June 16, 2023, the Action Plan to Accelerate the Elimination of Schistosomiasis in China (2023—2030) was jointly issued by National Disease Control and Prevention Administration and other 10 ministries, which deployed the targets and key tasks of the national schistosomiasis elimination programme in China. This article describes the progress of the national schistosomiasis control programme, analyzes the opportunities to eliminate schistosomiasis, and proposes targeted recommendations to tackle the challenges of schistosomiasis elimination, so as to accelerate the process towards schistosomiasis elimination and facilitate the building of a healthy China.

Result Analysis
Print
Save
E-mail