1.The Incidence of Occult Malignancy in Contralateral Risk Reducing Mastectomy Among Affected Breast Cancer Gene Mutation Carriers in South Korea
Cho Eun LEE ; Dong Seung SHIN ; Ki Jo KIM ; Seok Jin NAM ; Seok Won KIM ; Jonghan YU ; Byung Joo CHAE ; Se Kyung LEE ; Jai Min RYU ; Goo-Hyun MUN ; Jai-Kyong PYON ; Byung-Joon JEON ; Kyongje WOO ; Jeong Eon LEE
Journal of Breast Cancer 2025;28(1):1-10
		                        		
		                        			 Purpose:
		                        			Breast cancer gene (BRCA) mutation is a well-known risk factor for breast cancer, and clinical interest in prophylactic mastectomy has increased in recent years.We investigated patients who were BRCA mutation carriers and underwent contralateral risk-reducing mastectomy (RRM), focusing on the incidence of occult malignancy after contralateral RRM. 
		                        		
		                        			Methods:
		                        			Prospectively collected data of patients with breast cancer treated at a single institution were retrospectively reviewed. Patients who underwent RRM with BRCA mutation who underwent RRM between January 2010 and November 2023 were included in this study.Among patients who underwent contralateral RRM, those with a primary cancer diagnosis were included, and those with occult malignancy on the contralateral RRM side were reviewed additionally. The demographics and pathologies of both primary breast cancer and occult malignancies were evaluated. 
		                        		
		                        			Results:
		                        			In our institution, 925 patients were identified as BRCA mutation carriers, and 320 patients underwent contralateral RRM along with primary breast cancer surgery. BRCA2 mutation occurred more frequently (54.8%) in the overall BRCA mutation cohort. Furthermore, we reviewed 320 patients diagnosed with breast cancer and detected as BRCA mutation carriers who underwent contralateral RRM; high proportion of them were BRCA1 mutation carriers.Interestingly, we found a low incidence of only seven patients (2.2%) with occult malignancy on contralateral RRM side, which is different from that reported in other nations. 
		                        		
		                        			Conclusion
		                        			The incidence of occult malignancy in the contralateral breast of breast cancer patients with breast cancer with BRCA mutation is significantly low, and may be influenced by several factors. Increased utilization of screening and advancements in diagnostic technologies in South Korea have reduced the chance of occult malignancy in RRM, and a variety of pathologic examination methods may affect the rate of incidence. 
		                        		
		                        		
		                        		
		                        	
2.The Incidence of Occult Malignancy in Contralateral Risk Reducing Mastectomy Among Affected Breast Cancer Gene Mutation Carriers in South Korea
Cho Eun LEE ; Dong Seung SHIN ; Ki Jo KIM ; Seok Jin NAM ; Seok Won KIM ; Jonghan YU ; Byung Joo CHAE ; Se Kyung LEE ; Jai Min RYU ; Goo-Hyun MUN ; Jai-Kyong PYON ; Byung-Joon JEON ; Kyongje WOO ; Jeong Eon LEE
Journal of Breast Cancer 2025;28(1):1-10
		                        		
		                        			 Purpose:
		                        			Breast cancer gene (BRCA) mutation is a well-known risk factor for breast cancer, and clinical interest in prophylactic mastectomy has increased in recent years.We investigated patients who were BRCA mutation carriers and underwent contralateral risk-reducing mastectomy (RRM), focusing on the incidence of occult malignancy after contralateral RRM. 
		                        		
		                        			Methods:
		                        			Prospectively collected data of patients with breast cancer treated at a single institution were retrospectively reviewed. Patients who underwent RRM with BRCA mutation who underwent RRM between January 2010 and November 2023 were included in this study.Among patients who underwent contralateral RRM, those with a primary cancer diagnosis were included, and those with occult malignancy on the contralateral RRM side were reviewed additionally. The demographics and pathologies of both primary breast cancer and occult malignancies were evaluated. 
		                        		
		                        			Results:
		                        			In our institution, 925 patients were identified as BRCA mutation carriers, and 320 patients underwent contralateral RRM along with primary breast cancer surgery. BRCA2 mutation occurred more frequently (54.8%) in the overall BRCA mutation cohort. Furthermore, we reviewed 320 patients diagnosed with breast cancer and detected as BRCA mutation carriers who underwent contralateral RRM; high proportion of them were BRCA1 mutation carriers.Interestingly, we found a low incidence of only seven patients (2.2%) with occult malignancy on contralateral RRM side, which is different from that reported in other nations. 
		                        		
		                        			Conclusion
		                        			The incidence of occult malignancy in the contralateral breast of breast cancer patients with breast cancer with BRCA mutation is significantly low, and may be influenced by several factors. Increased utilization of screening and advancements in diagnostic technologies in South Korea have reduced the chance of occult malignancy in RRM, and a variety of pathologic examination methods may affect the rate of incidence. 
		                        		
		                        		
		                        		
		                        	
3.The Incidence of Occult Malignancy in Contralateral Risk Reducing Mastectomy Among Affected Breast Cancer Gene Mutation Carriers in South Korea
Cho Eun LEE ; Dong Seung SHIN ; Ki Jo KIM ; Seok Jin NAM ; Seok Won KIM ; Jonghan YU ; Byung Joo CHAE ; Se Kyung LEE ; Jai Min RYU ; Goo-Hyun MUN ; Jai-Kyong PYON ; Byung-Joon JEON ; Kyongje WOO ; Jeong Eon LEE
Journal of Breast Cancer 2025;28(1):1-10
		                        		
		                        			 Purpose:
		                        			Breast cancer gene (BRCA) mutation is a well-known risk factor for breast cancer, and clinical interest in prophylactic mastectomy has increased in recent years.We investigated patients who were BRCA mutation carriers and underwent contralateral risk-reducing mastectomy (RRM), focusing on the incidence of occult malignancy after contralateral RRM. 
		                        		
		                        			Methods:
		                        			Prospectively collected data of patients with breast cancer treated at a single institution were retrospectively reviewed. Patients who underwent RRM with BRCA mutation who underwent RRM between January 2010 and November 2023 were included in this study.Among patients who underwent contralateral RRM, those with a primary cancer diagnosis were included, and those with occult malignancy on the contralateral RRM side were reviewed additionally. The demographics and pathologies of both primary breast cancer and occult malignancies were evaluated. 
		                        		
		                        			Results:
		                        			In our institution, 925 patients were identified as BRCA mutation carriers, and 320 patients underwent contralateral RRM along with primary breast cancer surgery. BRCA2 mutation occurred more frequently (54.8%) in the overall BRCA mutation cohort. Furthermore, we reviewed 320 patients diagnosed with breast cancer and detected as BRCA mutation carriers who underwent contralateral RRM; high proportion of them were BRCA1 mutation carriers.Interestingly, we found a low incidence of only seven patients (2.2%) with occult malignancy on contralateral RRM side, which is different from that reported in other nations. 
		                        		
		                        			Conclusion
		                        			The incidence of occult malignancy in the contralateral breast of breast cancer patients with breast cancer with BRCA mutation is significantly low, and may be influenced by several factors. Increased utilization of screening and advancements in diagnostic technologies in South Korea have reduced the chance of occult malignancy in RRM, and a variety of pathologic examination methods may affect the rate of incidence. 
		                        		
		                        		
		                        		
		                        	
4.The cumulative survival rate of dental implants with micro-threads:a long-term retrospective study
Dong-Hui NAM ; Pil-Jong KIM ; Ki-Tae KOO ; Yang-Jo SEOL ; Yong-Moo LEE ; Young KU ; In-Chul RHYU ; Sungtae KIM ; Young-Dan CHO
Journal of Periodontal & Implant Science 2024;54(1):53-62
		                        		
		                        			 Purpose:
		                        			This study aimed to evaluate the long-term cumulative survival rate (CSR) of dental implants with micro-threads in the neck over a 10-year follow-up period and to examine the factors influencing the survival rate of dental implants. 
		                        		
		                        			Methods:
		                        			This retrospective study was based on radiographic and dental records. In total, 151 patients received 490 Oneplant ® dental implants with an implant neck micro-thread design during 2006–2010 in the Department of Periodontology of Seoul National University Dental Hospital. Implant survival was evaluated using Kaplan–Meier analysis. Cox proportional hazard regression analysis was used to identify the factors influencing implant failure. 
		                        		
		                        			Results:
		                        			Ten out of 490 implants (2.04%) failed due to fixture fracture. The CSR of the implants was 97.9%, and no significant difference was observed in the CSR between externaland internal-implant types (98.2% and 97.6%, respectively,P=0.670). In Cox regression analysis, 2-stage surgery significantly increased the risk of implant failure (hazard ratio: 4.769, P=0.039). There were no significant differences in influencing factors, including sex, age, implant diameter, length, fixture type, location, surgical procedure, bone grafting, and restoration type. 
		                        		
		                        			Conclusions
		                        			Within the limitations of this retrospective study, the micro-thread design of the implant neck was found to be favorable for implant survival, with stable clinical outcomes. 
		                        		
		                        		
		                        		
		                        	
5.Simulating the Effect of Junction Setup Error in Dual-Isocentric Volumetric Modulated Arc Therapy for Pelvic Radiotherapy with a Large Target
Hojeong LEE ; Dong Woon KIM ; Ji Hyeon JOO ; Yongkan KI ; Wontaek KIM ; Dahl PARK ; Jiho NAM ; Dong Hyeon KIM ; Hosang JEON
Progress in Medical Physics 2024;35(2):52-57
		                        		
		                        			 Purpose:
		                        			The use of two adjacent radiation beams to treat a lesion that is larger than the maximum field of a machine may lead to higher or lower dose distribution at the junction than expected. Therefore, evaluation of the junction dose is crucial for radiotherapy. Volumetric modulated arc therapy (VMAT) can effectively protect surrounding normal tissues by implementing a complex dose distribution; therefore, two adjacent VMAT fields can effectively treat large lesions. However, VMAT can lead to significant errors in the junction dose between fields if setup errors occur due to its highly complex dose distributions. 
		                        		
		                        			Methods:
		                        			In this study, setup errors of ±1, ±3, and ±5 mm were assumed during radiotherapy for treating large lesions in the lower abdomen, and their effects on the treatment dose distribution and target coverage were analyzed using gamma pass rate (GP) and homogeneity index (HI). All studies were performed using a computational simulation method based on our radiation treatment planning software. 
		                        		
		                        			Results:
		                        			Consequently, when the setup error was more than ±3 mm, most GP values using a 3%/3-mm criterion decreased by <90%. GP was independent of the direction of the field gap (FG), whereas HI values were relatively more affected by negative values for FG. 
		                        		
		                        			Conclusions
		                        			Therefore, the size and direction of setup errors should be carefully managed when performing dual-isocentric VMATs for large targets. 
		                        		
		                        		
		                        		
		                        	
6.Simulating the Effect of Junction Setup Error in Dual-Isocentric Volumetric Modulated Arc Therapy for Pelvic Radiotherapy with a Large Target
Hojeong LEE ; Dong Woon KIM ; Ji Hyeon JOO ; Yongkan KI ; Wontaek KIM ; Dahl PARK ; Jiho NAM ; Dong Hyeon KIM ; Hosang JEON
Progress in Medical Physics 2024;35(2):52-57
		                        		
		                        			 Purpose:
		                        			The use of two adjacent radiation beams to treat a lesion that is larger than the maximum field of a machine may lead to higher or lower dose distribution at the junction than expected. Therefore, evaluation of the junction dose is crucial for radiotherapy. Volumetric modulated arc therapy (VMAT) can effectively protect surrounding normal tissues by implementing a complex dose distribution; therefore, two adjacent VMAT fields can effectively treat large lesions. However, VMAT can lead to significant errors in the junction dose between fields if setup errors occur due to its highly complex dose distributions. 
		                        		
		                        			Methods:
		                        			In this study, setup errors of ±1, ±3, and ±5 mm were assumed during radiotherapy for treating large lesions in the lower abdomen, and their effects on the treatment dose distribution and target coverage were analyzed using gamma pass rate (GP) and homogeneity index (HI). All studies were performed using a computational simulation method based on our radiation treatment planning software. 
		                        		
		                        			Results:
		                        			Consequently, when the setup error was more than ±3 mm, most GP values using a 3%/3-mm criterion decreased by <90%. GP was independent of the direction of the field gap (FG), whereas HI values were relatively more affected by negative values for FG. 
		                        		
		                        			Conclusions
		                        			Therefore, the size and direction of setup errors should be carefully managed when performing dual-isocentric VMATs for large targets. 
		                        		
		                        		
		                        		
		                        	
7.2024 Korean Society of Myocardial Infarction/National Evidence-Based Healthcare Collaborating Agency Guideline for the Pharmacotherapy of Acute Coronary Syndromes
Hyun Kuk KIM ; Seungeun RYOO ; Seung Hun LEE ; Doyeon HWANG ; Ki Hong CHOI ; Jungeun PARK ; Hyeon-Jeong LEE ; Chang-Hwan YOON ; Jang Hoon LEE ; Joo-Yong HAHN ; Young Joon HONG ; Jin Yong HWANG ; Myung Ho JEONG ; Dong Ah PARK ; Chang-Wook NAM ; Weon KIM
Korean Circulation Journal 2024;54(12):767-793
		                        		
		                        			
		                        			 Many countries have published clinical practice guidelines for appropriate clinical decisions, optimal treatment, and improved clinical outcomes in patients with acute coronary syndrome. Developing guidelines that are specifically tailored to the Korean environment is crucial, considering the treatment system, available medications and medical devices, racial differences, and level of language communication. In 2017, the Korean Society of Myocardial Infarction established a guideline development committee. However, at that time, it was not feasible to develop guidelines, owing to the lack of knowledge and experience in guideline development and the absence of methodology experts. In 2022, the National EvidenceBased Healthcare Collaborating Agency collaborated with a relevant academic association to develop internationally reliable guidelines, with strict adherence to the methodology for evidence-based guideline development. The first Korean acute coronary syndrome guideline starts from the 9 key questions for pharmacotherapy. 
		                        		
		                        		
		                        		
		                        	
8.Simulating the Effect of Junction Setup Error in Dual-Isocentric Volumetric Modulated Arc Therapy for Pelvic Radiotherapy with a Large Target
Hojeong LEE ; Dong Woon KIM ; Ji Hyeon JOO ; Yongkan KI ; Wontaek KIM ; Dahl PARK ; Jiho NAM ; Dong Hyeon KIM ; Hosang JEON
Progress in Medical Physics 2024;35(2):52-57
		                        		
		                        			 Purpose:
		                        			The use of two adjacent radiation beams to treat a lesion that is larger than the maximum field of a machine may lead to higher or lower dose distribution at the junction than expected. Therefore, evaluation of the junction dose is crucial for radiotherapy. Volumetric modulated arc therapy (VMAT) can effectively protect surrounding normal tissues by implementing a complex dose distribution; therefore, two adjacent VMAT fields can effectively treat large lesions. However, VMAT can lead to significant errors in the junction dose between fields if setup errors occur due to its highly complex dose distributions. 
		                        		
		                        			Methods:
		                        			In this study, setup errors of ±1, ±3, and ±5 mm were assumed during radiotherapy for treating large lesions in the lower abdomen, and their effects on the treatment dose distribution and target coverage were analyzed using gamma pass rate (GP) and homogeneity index (HI). All studies were performed using a computational simulation method based on our radiation treatment planning software. 
		                        		
		                        			Results:
		                        			Consequently, when the setup error was more than ±3 mm, most GP values using a 3%/3-mm criterion decreased by <90%. GP was independent of the direction of the field gap (FG), whereas HI values were relatively more affected by negative values for FG. 
		                        		
		                        			Conclusions
		                        			Therefore, the size and direction of setup errors should be carefully managed when performing dual-isocentric VMATs for large targets. 
		                        		
		                        		
		                        		
		                        	
9.2024 Korean Society of Myocardial Infarction/National Evidence-Based Healthcare Collaborating Agency Guideline for the Pharmacotherapy of Acute Coronary Syndromes
Hyun Kuk KIM ; Seungeun RYOO ; Seung Hun LEE ; Doyeon HWANG ; Ki Hong CHOI ; Jungeun PARK ; Hyeon-Jeong LEE ; Chang-Hwan YOON ; Jang Hoon LEE ; Joo-Yong HAHN ; Young Joon HONG ; Jin Yong HWANG ; Myung Ho JEONG ; Dong Ah PARK ; Chang-Wook NAM ; Weon KIM
Korean Circulation Journal 2024;54(12):767-793
		                        		
		                        			
		                        			 Many countries have published clinical practice guidelines for appropriate clinical decisions, optimal treatment, and improved clinical outcomes in patients with acute coronary syndrome. Developing guidelines that are specifically tailored to the Korean environment is crucial, considering the treatment system, available medications and medical devices, racial differences, and level of language communication. In 2017, the Korean Society of Myocardial Infarction established a guideline development committee. However, at that time, it was not feasible to develop guidelines, owing to the lack of knowledge and experience in guideline development and the absence of methodology experts. In 2022, the National EvidenceBased Healthcare Collaborating Agency collaborated with a relevant academic association to develop internationally reliable guidelines, with strict adherence to the methodology for evidence-based guideline development. The first Korean acute coronary syndrome guideline starts from the 9 key questions for pharmacotherapy. 
		                        		
		                        		
		                        		
		                        	
10.2024 Korean Society of Myocardial Infarction/National Evidence-Based Healthcare Collaborating Agency Guideline for the Pharmacotherapy of Acute Coronary Syndromes
Hyun Kuk KIM ; Seungeun RYOO ; Seung Hun LEE ; Doyeon HWANG ; Ki Hong CHOI ; Jungeun PARK ; Hyeon-Jeong LEE ; Chang-Hwan YOON ; Jang Hoon LEE ; Joo-Yong HAHN ; Young Joon HONG ; Jin Yong HWANG ; Myung Ho JEONG ; Dong Ah PARK ; Chang-Wook NAM ; Weon KIM
Korean Circulation Journal 2024;54(12):767-793
		                        		
		                        			
		                        			 Many countries have published clinical practice guidelines for appropriate clinical decisions, optimal treatment, and improved clinical outcomes in patients with acute coronary syndrome. Developing guidelines that are specifically tailored to the Korean environment is crucial, considering the treatment system, available medications and medical devices, racial differences, and level of language communication. In 2017, the Korean Society of Myocardial Infarction established a guideline development committee. However, at that time, it was not feasible to develop guidelines, owing to the lack of knowledge and experience in guideline development and the absence of methodology experts. In 2022, the National EvidenceBased Healthcare Collaborating Agency collaborated with a relevant academic association to develop internationally reliable guidelines, with strict adherence to the methodology for evidence-based guideline development. The first Korean acute coronary syndrome guideline starts from the 9 key questions for pharmacotherapy. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail