1.Safety and Efficacy of Venous Coil-Embolization of Type IIa Pelvic Arteriovenous Malformations
Lyo Min KWON ; Sang Yub LEE ; Young Soo DO ; Kwang Bo PARK ; Jun Gon KIM ; Shin-Seok YANG ; Dong-Ik KIM
Korean Journal of Radiology 2025;26(3):239-245
Objective:
To evaluate the safety and efficacy of coil embolization of venous segments in patients with Type IIa pelvic arteriovenous malformations (AVMs).
Materials and Methods:
A retrospective study was performed on 13 patients (median age, 43 years, range 20–62 years, 7 males) who underwent transvenous coil embolization for Type IIa pelvic AVM (characterized by multiple arterioles shunting to focal venous segments of a single draining vein) without the use of additional liquid embolic agents from March 2017 to February 2023. Treatment outcomes were analyzed based on clinical evaluations, post angiography findings, and follow-up CT.
Results:
Fourteen procedures were performed on 13 patients. Except in one patient, all treatments were completed in a single session. Transvenous access was employed in 10 procedures, whereas direct puncture was used in four sessions. The embolization procedures used an average of 55.7 ± 58.5 coils (range, 7–238) and lasted an average of 127.3 ± 39.5 minutes.The technical success rate was 92.9% (of 13/14). All patients reported symptom improvement. Follow-up CT scans showed complete occlusion of the AVM without recurrence in ten of the 13 patients. There was one minor adverse event: a small retroperitoneal hemorrhage, likely related to direct puncture, which resolved spontaneously. No other adverse events were observed.
Conclusion
Coil embolization of the draining vein segment, without the use of additional liquid embolic agents is a safe and effective method for managing Type IIa pelvic AVM.
2.Safety and Efficacy of Venous Coil-Embolization of Type IIa Pelvic Arteriovenous Malformations
Lyo Min KWON ; Sang Yub LEE ; Young Soo DO ; Kwang Bo PARK ; Jun Gon KIM ; Shin-Seok YANG ; Dong-Ik KIM
Korean Journal of Radiology 2025;26(3):239-245
Objective:
To evaluate the safety and efficacy of coil embolization of venous segments in patients with Type IIa pelvic arteriovenous malformations (AVMs).
Materials and Methods:
A retrospective study was performed on 13 patients (median age, 43 years, range 20–62 years, 7 males) who underwent transvenous coil embolization for Type IIa pelvic AVM (characterized by multiple arterioles shunting to focal venous segments of a single draining vein) without the use of additional liquid embolic agents from March 2017 to February 2023. Treatment outcomes were analyzed based on clinical evaluations, post angiography findings, and follow-up CT.
Results:
Fourteen procedures were performed on 13 patients. Except in one patient, all treatments were completed in a single session. Transvenous access was employed in 10 procedures, whereas direct puncture was used in four sessions. The embolization procedures used an average of 55.7 ± 58.5 coils (range, 7–238) and lasted an average of 127.3 ± 39.5 minutes.The technical success rate was 92.9% (of 13/14). All patients reported symptom improvement. Follow-up CT scans showed complete occlusion of the AVM without recurrence in ten of the 13 patients. There was one minor adverse event: a small retroperitoneal hemorrhage, likely related to direct puncture, which resolved spontaneously. No other adverse events were observed.
Conclusion
Coil embolization of the draining vein segment, without the use of additional liquid embolic agents is a safe and effective method for managing Type IIa pelvic AVM.
3.Safety and Efficacy of Venous Coil-Embolization of Type IIa Pelvic Arteriovenous Malformations
Lyo Min KWON ; Sang Yub LEE ; Young Soo DO ; Kwang Bo PARK ; Jun Gon KIM ; Shin-Seok YANG ; Dong-Ik KIM
Korean Journal of Radiology 2025;26(3):239-245
Objective:
To evaluate the safety and efficacy of coil embolization of venous segments in patients with Type IIa pelvic arteriovenous malformations (AVMs).
Materials and Methods:
A retrospective study was performed on 13 patients (median age, 43 years, range 20–62 years, 7 males) who underwent transvenous coil embolization for Type IIa pelvic AVM (characterized by multiple arterioles shunting to focal venous segments of a single draining vein) without the use of additional liquid embolic agents from March 2017 to February 2023. Treatment outcomes were analyzed based on clinical evaluations, post angiography findings, and follow-up CT.
Results:
Fourteen procedures were performed on 13 patients. Except in one patient, all treatments were completed in a single session. Transvenous access was employed in 10 procedures, whereas direct puncture was used in four sessions. The embolization procedures used an average of 55.7 ± 58.5 coils (range, 7–238) and lasted an average of 127.3 ± 39.5 minutes.The technical success rate was 92.9% (of 13/14). All patients reported symptom improvement. Follow-up CT scans showed complete occlusion of the AVM without recurrence in ten of the 13 patients. There was one minor adverse event: a small retroperitoneal hemorrhage, likely related to direct puncture, which resolved spontaneously. No other adverse events were observed.
Conclusion
Coil embolization of the draining vein segment, without the use of additional liquid embolic agents is a safe and effective method for managing Type IIa pelvic AVM.
4.Safety and Efficacy of Venous Coil-Embolization of Type IIa Pelvic Arteriovenous Malformations
Lyo Min KWON ; Sang Yub LEE ; Young Soo DO ; Kwang Bo PARK ; Jun Gon KIM ; Shin-Seok YANG ; Dong-Ik KIM
Korean Journal of Radiology 2025;26(3):239-245
Objective:
To evaluate the safety and efficacy of coil embolization of venous segments in patients with Type IIa pelvic arteriovenous malformations (AVMs).
Materials and Methods:
A retrospective study was performed on 13 patients (median age, 43 years, range 20–62 years, 7 males) who underwent transvenous coil embolization for Type IIa pelvic AVM (characterized by multiple arterioles shunting to focal venous segments of a single draining vein) without the use of additional liquid embolic agents from March 2017 to February 2023. Treatment outcomes were analyzed based on clinical evaluations, post angiography findings, and follow-up CT.
Results:
Fourteen procedures were performed on 13 patients. Except in one patient, all treatments were completed in a single session. Transvenous access was employed in 10 procedures, whereas direct puncture was used in four sessions. The embolization procedures used an average of 55.7 ± 58.5 coils (range, 7–238) and lasted an average of 127.3 ± 39.5 minutes.The technical success rate was 92.9% (of 13/14). All patients reported symptom improvement. Follow-up CT scans showed complete occlusion of the AVM without recurrence in ten of the 13 patients. There was one minor adverse event: a small retroperitoneal hemorrhage, likely related to direct puncture, which resolved spontaneously. No other adverse events were observed.
Conclusion
Coil embolization of the draining vein segment, without the use of additional liquid embolic agents is a safe and effective method for managing Type IIa pelvic AVM.
5.Safety and Efficacy of Venous Coil-Embolization of Type IIa Pelvic Arteriovenous Malformations
Lyo Min KWON ; Sang Yub LEE ; Young Soo DO ; Kwang Bo PARK ; Jun Gon KIM ; Shin-Seok YANG ; Dong-Ik KIM
Korean Journal of Radiology 2025;26(3):239-245
Objective:
To evaluate the safety and efficacy of coil embolization of venous segments in patients with Type IIa pelvic arteriovenous malformations (AVMs).
Materials and Methods:
A retrospective study was performed on 13 patients (median age, 43 years, range 20–62 years, 7 males) who underwent transvenous coil embolization for Type IIa pelvic AVM (characterized by multiple arterioles shunting to focal venous segments of a single draining vein) without the use of additional liquid embolic agents from March 2017 to February 2023. Treatment outcomes were analyzed based on clinical evaluations, post angiography findings, and follow-up CT.
Results:
Fourteen procedures were performed on 13 patients. Except in one patient, all treatments were completed in a single session. Transvenous access was employed in 10 procedures, whereas direct puncture was used in four sessions. The embolization procedures used an average of 55.7 ± 58.5 coils (range, 7–238) and lasted an average of 127.3 ± 39.5 minutes.The technical success rate was 92.9% (of 13/14). All patients reported symptom improvement. Follow-up CT scans showed complete occlusion of the AVM without recurrence in ten of the 13 patients. There was one minor adverse event: a small retroperitoneal hemorrhage, likely related to direct puncture, which resolved spontaneously. No other adverse events were observed.
Conclusion
Coil embolization of the draining vein segment, without the use of additional liquid embolic agents is a safe and effective method for managing Type IIa pelvic AVM.
6.Comparison of micro-flow imaging and contrast-enhanced ultrasonography in assessing segmental congestion after right living donor liver transplantation
Taewon HAN ; Woo Kyoung JEONG ; Jaeseung SHIN ; Dong Ik CHA ; Kyowon GU ; Jinsoo RHU ; Jong Man KIM ; Gyu-Seong CHOI
Ultrasonography 2024;43(6):469-477
Purpose:
This study aimed to determine whether micro-flow imaging (MFI) offers diagnostic performance comparable to that of contrast-enhanced ultrasonography (CEUS) in detecting segmental congestion among patients undergoing living donor liver transplantation (LDLT).
Methods:
Data from 63 patients who underwent LDLT between May and December 2022 were retrospectively analyzed. MFI and CEUS data collected on the first postoperative day were quantified. Segmental congestion was assessed based on imaging findings and laboratory data, including liver enzymes and total bilirubin levels. The reference standard was a postoperative contrast-enhanced computed tomography scan performed within 2 weeks of surgery. Additionally, a subgroup analysis examined patients who underwent reconstruction of the middle hepatic vein territory.
Results:
The sensitivity and specificity of MFI were 73.9% and 67.5%, respectively. In comparison, CEUS demonstrated a sensitivity of 78.3% and a specificity of 75.0%. These findings suggest comparable diagnostic performance, with no significant differences in sensitivity (P=0.655) or specificity (P=0.257) between the two modalities. Additionally, early postoperative laboratory values did not show significant differences between patients with and without congestion. The subgroup analysis also indicated similar diagnostic performance between MFI and CEUS.
Conclusion
MFI without contrast enhancement yielded results comparable to those of CEUS in detecting segmental congestion after LDLT. Therefore, MFI may be considered a viable alternative to CEUS.
7.Validation of the Vascular Study Group of New England (VSGNE) risk prediction model for abdominal aortic aneurysm repair in Korea: a single-center retrospective study
Hyo-Shin KIM ; Da-Hyun KIM ; Dong-Ik KIM ; Joon-Kee PARK ; Shin-Seok YANG ; Yang-Jin PARK
Annals of Surgical Treatment and Research 2024;107(6):315-326
Purpose:
The Vascular Study Group of New England (VSGNE) risk prediction model is a simple method for estimating risk for elective abdominal aortic aneurysm (AAA) repair. The model considers both treatment methods and the physical characteristics of the aneurysm type as well as comorbidities. This research aimed to validate its effectiveness by analyzing retrospective data on Korean patients.
Methods:
Our single-center retrospective analysis included 1,227 patients who underwent elective open repair surgery (ORS) or endovascular aortic repair (EVAR) from 2005 to 2021. We assessed the discrimination of the risk score and the effects of several risk factors.
Results:
Most patients (66.7%) were classified as low risk in the model, with only 5.6% considered high risk. The mean risk score was 2.81, significantly lower than reported in previous studies. The actual 30-day mortality was only 0.7%, less than the predicted 1.1%. The accuracy of the model in predicting 30-day mortality was statistically significant (area under the curve, 0.822). Patients with high scores were associated with significantly increased mortality (odds ratio, 3.9; P < 0.001). Factors such as advanced age, cerebrovascular disease, and elevated creatinine levels were influential in mortality outcomes. However, a significant difference was not found in short-term mortality between ORS and EVAR.
Conclusion
Although the VSGNE model is an objective tool for assessing death risk in elective AAA repair, the actual risk scores in our patient population were lower than predicted. To create a more representative tool for the Korean population, we suggest developing a novel model based on multicenter data collection.
8.Comparison of micro-flow imaging and contrast-enhanced ultrasonography in assessing segmental congestion after right living donor liver transplantation
Taewon HAN ; Woo Kyoung JEONG ; Jaeseung SHIN ; Dong Ik CHA ; Kyowon GU ; Jinsoo RHU ; Jong Man KIM ; Gyu-Seong CHOI
Ultrasonography 2024;43(6):469-477
Purpose:
This study aimed to determine whether micro-flow imaging (MFI) offers diagnostic performance comparable to that of contrast-enhanced ultrasonography (CEUS) in detecting segmental congestion among patients undergoing living donor liver transplantation (LDLT).
Methods:
Data from 63 patients who underwent LDLT between May and December 2022 were retrospectively analyzed. MFI and CEUS data collected on the first postoperative day were quantified. Segmental congestion was assessed based on imaging findings and laboratory data, including liver enzymes and total bilirubin levels. The reference standard was a postoperative contrast-enhanced computed tomography scan performed within 2 weeks of surgery. Additionally, a subgroup analysis examined patients who underwent reconstruction of the middle hepatic vein territory.
Results:
The sensitivity and specificity of MFI were 73.9% and 67.5%, respectively. In comparison, CEUS demonstrated a sensitivity of 78.3% and a specificity of 75.0%. These findings suggest comparable diagnostic performance, with no significant differences in sensitivity (P=0.655) or specificity (P=0.257) between the two modalities. Additionally, early postoperative laboratory values did not show significant differences between patients with and without congestion. The subgroup analysis also indicated similar diagnostic performance between MFI and CEUS.
Conclusion
MFI without contrast enhancement yielded results comparable to those of CEUS in detecting segmental congestion after LDLT. Therefore, MFI may be considered a viable alternative to CEUS.
9.Comparison of micro-flow imaging and contrast-enhanced ultrasonography in assessing segmental congestion after right living donor liver transplantation
Taewon HAN ; Woo Kyoung JEONG ; Jaeseung SHIN ; Dong Ik CHA ; Kyowon GU ; Jinsoo RHU ; Jong Man KIM ; Gyu-Seong CHOI
Ultrasonography 2024;43(6):469-477
Purpose:
This study aimed to determine whether micro-flow imaging (MFI) offers diagnostic performance comparable to that of contrast-enhanced ultrasonography (CEUS) in detecting segmental congestion among patients undergoing living donor liver transplantation (LDLT).
Methods:
Data from 63 patients who underwent LDLT between May and December 2022 were retrospectively analyzed. MFI and CEUS data collected on the first postoperative day were quantified. Segmental congestion was assessed based on imaging findings and laboratory data, including liver enzymes and total bilirubin levels. The reference standard was a postoperative contrast-enhanced computed tomography scan performed within 2 weeks of surgery. Additionally, a subgroup analysis examined patients who underwent reconstruction of the middle hepatic vein territory.
Results:
The sensitivity and specificity of MFI were 73.9% and 67.5%, respectively. In comparison, CEUS demonstrated a sensitivity of 78.3% and a specificity of 75.0%. These findings suggest comparable diagnostic performance, with no significant differences in sensitivity (P=0.655) or specificity (P=0.257) between the two modalities. Additionally, early postoperative laboratory values did not show significant differences between patients with and without congestion. The subgroup analysis also indicated similar diagnostic performance between MFI and CEUS.
Conclusion
MFI without contrast enhancement yielded results comparable to those of CEUS in detecting segmental congestion after LDLT. Therefore, MFI may be considered a viable alternative to CEUS.
10.Left-Sided Inferior Vena Cava Associated with Abdominal Aortic Aneurysm
Seung-Kee MIN ; Hyoshin KIM ; Joonkee PARK ; Shin-Seok YANG ; Dong-Ik KIM
Annals of phlebology 2024;22(1):32-35
Left-sided inferior vena cava (IVC) is a congenital venous anomaly variant with an incidence of 0.2%–0.5%. Furthermore case of abdominal aortic aneurysm with left-sided IVC is very rare. We reported our experience with two cases of left-sided IVC during open repair of the abdominal aortic aneurysm.

Result Analysis
Print
Save
E-mail