1.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
2.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
3.Comparison between Suture-Button Technique with Syndesmotic Repair and Screw Fixation Technique for Complete Ankle Syndesmotic Injury: Biomechanical Cadaveric Study
Hong Seop LEE ; Sung Hwan KIM ; Ki Won YOUNG ; Woo Jong KIM ; Dong-Il CHEON ; Sung Hun WON ; Sang Heon LEE ; Seung Jin CHOI ; Young Koo LEE
Clinics in Orthopedic Surgery 2025;17(2):324-330
Background:
The tibiofibular syndesmosis is essential for preserving the stability of the ankle. Acute syndesmotic injuries with evident or latent instability usually warrant surgical interventions. This cadaveric study examines and compares biomechanical characteristics between the following treatments for syndesmosis injuries: suture-button fixation plus syndesmotic repair and screw fixation.
Methods:
The lower extremities of 10 cadavers disarticulated at the knee joints were used, yielding 20 feet. Ten feet underwent surgery using the suture-button fixation with syndesmotic repair, while the remaining 10 feet underwent surgery using screw fixation. Before surgical treatment of syndesmosis injuries, each cadaveric lower limb underwent preliminary physiological cyclic loading, which was followed by a series of postfixation cyclic loading tests after the surgical procedure.
Results:
Our principal finding is that suture-button fixation with syndesmotic repair provided torsional strength comparable to that of screw fixation. The mean failure torque did not differ between the 2 groups, but the rotational stiffness was significantly lower in the suture-button fixation/augmentation group.
Conclusions
Suture-button fixation/augmentation facilitates flexible (physiological) syndesmosis movement and may be a useful alternative treatment for ankle syndesmosis injury.
4.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
5.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
6.A Study on the Healthcare Workforce and Care for Acute Stroke: Results From the Survey of Hospitals Included in the National Acute Stroke Quality Assessment Program
Jong Young LEE ; Jun Kyeong KO ; Hak Cheol KO ; Hae-Won KOO ; Hyon-Jo KWON ; Dae-Won KIM ; Kangmin KIM ; Myeong Jin KIM ; Hoon KIM ; Keun Young PARK ; Kuhyun YANG ; Jae Sang OH ; Won Ki YOON ; Dong Hoon LEE ; Ho Jun YI ; Heui Seung LEE ; Jong-Kook RHIM ; Dong-Kyu JANG ; Youngjin JUNG ; Sang Woo HA ; Seung Hun SHEEN
Journal of Korean Medical Science 2025;40(16):e44-
Background:
With growing elderly populations, management of patients with acute stroke is increasingly important. In South Korea, the Acute Stroke Quality Assessment Program (ASQAP) has contributed to improving the quality of stroke care and practice behavior in healthcare institutions. While the mortality of hemorrhagic stroke remains high, there are only a few assessment indices associated with hemorrhagic stroke. Considering the need to develop assessment indices to improve the actual quality of care in the field of acute stroke treatment, this study aims to investigate the current status of human resources and practices related to the treatment of patients with acute stroke through a nationwide survey.
Methods:
For the healthcare institutions included in the Ninth ASQAP of the Health Insurance Review and Assessment Service (HIRA), data from January 2022 to December 2022 were collected through a survey on the current status and practice of healthcare providers related to the treatment of patients with acute stroke. The questionnaire consisted of 19 items, including six items on healthcare providers involved in stroke care and 10 items on the care of patients with acute stroke.
Results:
In the treatment of patients with hemorrhagic stroke among patients with acute stroke, neurosurgeons were the most common providers. The contribution of neurosurgeons in the treatment of ischemic stroke has also been found to be equivalent to that of neurologists. However, a number of institutions were found to be devoid of healthcare providers who perform definitive treatments, such as intra-arterial thrombectomy for patients with ischemic stroke or cerebral aneurysm clipping for subarachnoid hemorrhage. The intensity of the workload of healthcare providers involved in the care of patients with acute stroke, especially those involved in definitive treatment, was also found to be quite high.
Conclusion
Currently, there are almost no assessment indices specific to hemorrhagic stroke in the ASQAP for acute stroke. Furthermore, it does not reflect the reality of the healthcare providers and practices that provide definitive treatment for acute stroke. The findings of this study suggest the need for the development of appropriate assessment indices that reflect the realities of acute stroke care.
7.A Study on the Healthcare Workforce and Care for Acute Stroke: Results From the Survey of Hospitals Included in the National Acute Stroke Quality Assessment Program
Jong Young LEE ; Jun Kyeong KO ; Hak Cheol KO ; Hae-Won KOO ; Hyon-Jo KWON ; Dae-Won KIM ; Kangmin KIM ; Myeong Jin KIM ; Hoon KIM ; Keun Young PARK ; Kuhyun YANG ; Jae Sang OH ; Won Ki YOON ; Dong Hoon LEE ; Ho Jun YI ; Heui Seung LEE ; Jong-Kook RHIM ; Dong-Kyu JANG ; Youngjin JUNG ; Sang Woo HA ; Seung Hun SHEEN
Journal of Korean Medical Science 2025;40(16):e44-
Background:
With growing elderly populations, management of patients with acute stroke is increasingly important. In South Korea, the Acute Stroke Quality Assessment Program (ASQAP) has contributed to improving the quality of stroke care and practice behavior in healthcare institutions. While the mortality of hemorrhagic stroke remains high, there are only a few assessment indices associated with hemorrhagic stroke. Considering the need to develop assessment indices to improve the actual quality of care in the field of acute stroke treatment, this study aims to investigate the current status of human resources and practices related to the treatment of patients with acute stroke through a nationwide survey.
Methods:
For the healthcare institutions included in the Ninth ASQAP of the Health Insurance Review and Assessment Service (HIRA), data from January 2022 to December 2022 were collected through a survey on the current status and practice of healthcare providers related to the treatment of patients with acute stroke. The questionnaire consisted of 19 items, including six items on healthcare providers involved in stroke care and 10 items on the care of patients with acute stroke.
Results:
In the treatment of patients with hemorrhagic stroke among patients with acute stroke, neurosurgeons were the most common providers. The contribution of neurosurgeons in the treatment of ischemic stroke has also been found to be equivalent to that of neurologists. However, a number of institutions were found to be devoid of healthcare providers who perform definitive treatments, such as intra-arterial thrombectomy for patients with ischemic stroke or cerebral aneurysm clipping for subarachnoid hemorrhage. The intensity of the workload of healthcare providers involved in the care of patients with acute stroke, especially those involved in definitive treatment, was also found to be quite high.
Conclusion
Currently, there are almost no assessment indices specific to hemorrhagic stroke in the ASQAP for acute stroke. Furthermore, it does not reflect the reality of the healthcare providers and practices that provide definitive treatment for acute stroke. The findings of this study suggest the need for the development of appropriate assessment indices that reflect the realities of acute stroke care.
8.ERRATUM: Imaging follow-up strategy after endovascular treatment of intracranial aneurysms: A literature review and guideline recommendations
Yong-Hwan CHO ; Jaehyung CHOI ; Chae-Wook HUH ; Chang Hyeun KIM ; Chul Hoon CHANG ; Soon Chan KWON ; Young Woo KIM ; Seung Hun SHEEN ; Sukh Que PARK ; Jun Kyeung KO ; Sung-kon HA ; Hae Woong JEONG ; Hyen Seung KANG ;
Journal of Cerebrovascular and Endovascular Neurosurgery 2025;27(1):80-80
9.Comparison between Suture-Button Technique with Syndesmotic Repair and Screw Fixation Technique for Complete Ankle Syndesmotic Injury: Biomechanical Cadaveric Study
Hong Seop LEE ; Sung Hwan KIM ; Ki Won YOUNG ; Woo Jong KIM ; Dong-Il CHEON ; Sung Hun WON ; Sang Heon LEE ; Seung Jin CHOI ; Young Koo LEE
Clinics in Orthopedic Surgery 2025;17(2):324-330
Background:
The tibiofibular syndesmosis is essential for preserving the stability of the ankle. Acute syndesmotic injuries with evident or latent instability usually warrant surgical interventions. This cadaveric study examines and compares biomechanical characteristics between the following treatments for syndesmosis injuries: suture-button fixation plus syndesmotic repair and screw fixation.
Methods:
The lower extremities of 10 cadavers disarticulated at the knee joints were used, yielding 20 feet. Ten feet underwent surgery using the suture-button fixation with syndesmotic repair, while the remaining 10 feet underwent surgery using screw fixation. Before surgical treatment of syndesmosis injuries, each cadaveric lower limb underwent preliminary physiological cyclic loading, which was followed by a series of postfixation cyclic loading tests after the surgical procedure.
Results:
Our principal finding is that suture-button fixation with syndesmotic repair provided torsional strength comparable to that of screw fixation. The mean failure torque did not differ between the 2 groups, but the rotational stiffness was significantly lower in the suture-button fixation/augmentation group.
Conclusions
Suture-button fixation/augmentation facilitates flexible (physiological) syndesmosis movement and may be a useful alternative treatment for ankle syndesmosis injury.
10.Comparison between Suture-Button Technique with Syndesmotic Repair and Screw Fixation Technique for Complete Ankle Syndesmotic Injury: Biomechanical Cadaveric Study
Hong Seop LEE ; Sung Hwan KIM ; Ki Won YOUNG ; Woo Jong KIM ; Dong-Il CHEON ; Sung Hun WON ; Sang Heon LEE ; Seung Jin CHOI ; Young Koo LEE
Clinics in Orthopedic Surgery 2025;17(2):324-330
Background:
The tibiofibular syndesmosis is essential for preserving the stability of the ankle. Acute syndesmotic injuries with evident or latent instability usually warrant surgical interventions. This cadaveric study examines and compares biomechanical characteristics between the following treatments for syndesmosis injuries: suture-button fixation plus syndesmotic repair and screw fixation.
Methods:
The lower extremities of 10 cadavers disarticulated at the knee joints were used, yielding 20 feet. Ten feet underwent surgery using the suture-button fixation with syndesmotic repair, while the remaining 10 feet underwent surgery using screw fixation. Before surgical treatment of syndesmosis injuries, each cadaveric lower limb underwent preliminary physiological cyclic loading, which was followed by a series of postfixation cyclic loading tests after the surgical procedure.
Results:
Our principal finding is that suture-button fixation with syndesmotic repair provided torsional strength comparable to that of screw fixation. The mean failure torque did not differ between the 2 groups, but the rotational stiffness was significantly lower in the suture-button fixation/augmentation group.
Conclusions
Suture-button fixation/augmentation facilitates flexible (physiological) syndesmosis movement and may be a useful alternative treatment for ankle syndesmosis injury.

Result Analysis
Print
Save
E-mail